Residential Decks. Planning and Development Services Department



Similar documents
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Residential Deck Safety, Construction, and Repair

Uncovered Decks & Porches

COMMONLY USED RESIDENTIAL BUILDING CODES

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS


I N T E R N A T I O N A L R E S I D E N T I A L CO D E

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

RESIDENTIAL WOOD DECKS

Typical Deck Details

Number of Sides Required to Have a Handrail

BUILDING PERMIT SPECIFICATIONS

POST AND FRAME STRUCTURES (Pole Barns)

STANDARD OPEN PATIO COVER

Chapter 3 Pre-Installation, Foundations and Piers

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

COMMONLY USED RESIDENTIAL BUILDING CODES

Patio Covers / Carports

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

Mobile Home Pre-Inspection Checklist

TOWNSHIP OF TOMS RIVER ZONING OFFICE DECK CONSTRUCTION

The replacement or modification of existing windows shall comply with the following requirements:

RESIDENTIAL BUILDING PERMITS

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

TYPICAL PATIO COVERS 111

How to secure your property after a disaster

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

The Homeowner s Building Application Checklist for Constructing a Residential Sundeck

Building Department John Fiedler Construction Official Ext SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev

Building Code Clarifications - 7. Fire Resistance

AMERICAN GOTHIC PLAYHOUSE

Estimated Cost of Repair

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Basic Requirements for Residential Plan Review _

Timber Decks. Technical Note. March 2007

Single Family Residential Building Permit Questions & Answers

MANUFACTURED HOME INSTALLATION FOR PERMANENT FOUNDATIONS (TRANSVERSE FLOORS) (SUPPLEMENT TO MANUFACTURED HOME INSTALLATION MANUAL)

Simplified Steel Stair Design for Commercial and Institutional Buildings

March 14, Installation of Bay, Bow and Garden Windows

PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE. decking guard. rim joist joists

Wood Projects Outdoors. Post Hole Specifications. Deck Span Tables. Eakes.com

Superform Products Ltd.

Sample Drawing Package for One and Two Family Dwelling Applications

Attached/Detached Patio Cover/Carport

Building Information Packet

A Guide to Detached Residential Garages and Residential Workshops (based on 2006 BCBC)

Residential Foundations and Basements

DECKING INSTALLATION, CARE & MAINTENANCE INSTRUCTIONS MOISTURESHIELD.COM limited lifetime warranty

Certification: Building Plans Examiner. Exam ID: B3

ATI Evaluation Service A Division of Architectural Testing Certification Services

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

Residential Plan Routing Information

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

SUPER SHED. Indoor shelter for your outdoor tools.

Section A Roof Truss

CITY OF TORONTO. BY-LAW No

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Typical Finished Basement Details

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

A HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS

Walking and Working Surface Checklist:

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Page & Turnbull imagining change in historic environments through design, research, and technology

INFORMATION BULLETIN NO.

Uniform Construction Code (UCC) Manufactured Homes. Modular Homes. Building Permit Application Package

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

INFORMATION BULLETIN NO.

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

Residential Building Permit Process

Common Problems with Walls

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

Featuring TJ Rim Board and TimberStrand LSL

2014 FLORIDA BUILDING CODE

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

Typical Finished Basement Details

Duchesne County Department of Building Safety

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

OPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

PDmB, Inc. Definitions

CLACKAMAS COUNTY DEPARTMENT OF TRANSPORTATION AND DEVELOPMENT BUILDING CODES DIVISION R E S I D E N T I A L C O D E S U M M A R Y

Residential Building Permits

Charter Township of Shelby Harry Reese Building Director

MUNICODE SERVICES LTD.

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Gas Meter Clearances and Service Installation Requirements

WALKING-WORKING SURFACES (SLIPS, TRIPS, AND FALLS)

Mason County Building Department

Stair Parts Installation. Tricks

Exterior Elevated Elements Inspection Guidelines

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.

Transcription:

Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks www.opkansas.org Note: The information provided includes general requirements that should be considered as part of a project to construct, repair or replace a deck. This should not be considered as a complete list of code requirements. Complete information is available in the codes and ordinances adopted by the City. Code books can be obtained at City Hall or are available for review at the local public library. Some materials and construction methods may require the use of an architect, engineer or other design professional. PLANS AND PERMITS A building permit is required to construct or replace a deck. A site plan drawn to scale showing the location of the deck and setbacks from property lines and a construction plan showing the footings, columns, beams and joists sizes, spacing and connections is required to be submitted for review and approval with the permit application. EXCEPTIONS TO PERMIT REQUIREMENT Detached decks not exceeding 200 square feet in area, that are not more than 30 inches above grade measured 36 inches out from the perimeter of the deck at any point. The deck can not serve the required exit (front door). The deck can not be physically attached to the dwelling. Repair of the deck walking surface; guards; or hand rails. INSPECTIONS Footings or pier holes are not required to be inspected for open decks. Footing inspections are required for covered decks. A separate framing (rough-in) inspection is required if the under-floor framing and connections cannot be easily inspected during the final inspection. A final inspection is required after all work is complete. Scheduling an inspection - Inspections can be requested by contacting the Building Safety Division at (913) 895-6220, option #2. Inspections are scheduled for the next day unless a later date is requested. SETBACKS The following setbacks only apply to R-1, RP-1, R-2 and RP-2 Zoning Districts: Front Yard: The setback for a front yard is 30 feet or plated building line from the deck to the front property line. Open decks and porches may project 6 feet into the front or rear yard setback, provided the area of the encroachment does not exceed 60 square feet. Rear Yard: The setback for a rear yard is 25 feet from the deck to the rear property line. Open decks and porches may project 6 feet into the front or rear yard setback, provided the area of the encroachment does not exceed 60 square feet. Side Yard: The setback for a side yard is a minimum of 7 feet, and the total of both side yards must not be less than 20 percent of the of the lot; 20 feet must be provided on the street side of a corner lot. Generally, decks shall not extend beyond platted building setback lines or into a platted landscape easement. Revised May 2014 Page 1 of 9

SETBACK EXCEPTIONS: Decks with a maximum height of less than 30 inches may be as close as 3 feet to the rear property line, provided a platted building setback line, landscape or tree preservation easement is not encroached upon. Open decks and porches may project 6 feet into the front or rear yard setback, provided the area of the encroachment does not exceed 60 square feet. Detached decks are permitted to be 3 feet from the rear property line, provided they are at least 20 feet from any street right-of-way and located less than 25 feet from the rear property line. A deck that is a distance of 5 feet or more is considered to be detached. Patios or similar structures that are at or below grade may be located in any side or rear yard area provided they are at least 3 feet from any property line. Note: Some homes associations may have requirements other than those established by the City. Please contact your homes association if you have questions regarding its requirements. BUILDING CODES Materials - The deck must be constructed of either a naturally decay-resistant lumber or a pressure-treated lumber (ACQ) and be designed to support a live load of 40 psf (see Span Table). All composite materials (not 100% wood) shall be labeled and listed to comply with ASTM D 7032. Electrical - All overhead power lines must be located at least 10 feet above the deck floor or be at least 3 feet horizontally away from the floor s surface. An exterior light for illumination of any steps is required. Where a deck is accessible from the inside of the dwelling an exterior GFCI electrical out let is required. The outlet shall be with in the perimeter of the deck and no more than 6 feet 6 inches above the deck walking surface. Where the deck is open a bubble type cover which will allow an electrical cord to be in use when the cover is closed is required. Where the deck is covered and creates only a damp condition an outlet cover that can be closed with out an electrical cord to be in use is permitted. Footings/Soil bearing - All decks must sit on footing or piers that are adequately designed to support the imposed loads (maximum assumed bearing capacity is 1500 pounds per square foot). Footings or piers shall extend 36 inches below the finished ground level. Guardrails - Porches, balconies or raised floor surfaces located more than 30 inches above the floor or grade with in 36 inches from the edge or perimeter of the deck below shall have guardrails not less than 36 inches in height. Open sides of stairs with a total rise of more than 30 inches above the floor or grade below shall have guardrails not less than 34 inches in height measured vertically from the nosing of the treads. Required guardrails on open sides of stairways, raised floor areas, balconies and porches shall have intermediate rails or ornamental closures that do not allow passage of an sphere 4 inches or more in diameter. The triangular openings formed by the riser, tread and bottom rail of a guard at the open side of a stairway shall not allow passage of an sphere 6 inches or more in diameter. Handrails A graspable hand rail is required on at least one side for stairs with 4 or more risers regardless of the height of the stairs. Handrails shall be mounted a minimum 34 inches and a maximum 38 inches above the nosing of the treads and be continuous for the run of the stair and has no less than 1 ½ clearance from the wall or any obstruction. The handrail ends shall be returned or terminate in the newel post or safety terminal. Handrails with a circular cross-section shall have a minimum 1 ¼ inch and maximum 2 inch diameter. If the handrail is not circular, it shall have a perimeter dimension of at least 4 inches and not greater than 6 ¼ inches with a maximum cross section dimension of 2 ¼ inches. Revised May 2014 Page 2 of 9

Handrails (not circular) with a perimeter greater than 6 ¼ inches and a minimum 1 ¾ inches in height shall have a graspable finger groove on both sides of the profile starting within ¾ of the top of the handrail reaching a minimum depth of 5/16 inch with in a height of 7/8 for a minimum of 3/8 height for the full 5/16 inch groove depth. Handrails of composite material (not 100% wood) shall be labeled and listed to comply with ASTM D 7032. Handrails shall have a minimum radius on any edge of ¼ on the graspable portions of its surface. Stairways - If steps are provided the maximum rise of each step is 7 ¾ inches and the minimum depth of each tread is 10 inches. The of the stairs must be at least 36 inches. A maximum 3/8-inch variation is permitted between the greatest and smallest rise and the greatest and smallest run of each flight of stairs. If four or more risers are provided on the stairs, a handrail/guardrail must be provided on both sides with a height of 34 to 38 inches above the nosing of the treads. Framing - Maximum span for decking shall comply with the decking span chart. Ledger - Where the ledger is attached directly to the house, care is required to provide an attachment method that will not cause deterioration of the house siding. Over standard panel siding we recommend adding the ledger directly over the batten board or for walls without batten boards; 1x furring strips be added at each lag screws or bolts location. This will minimize the potential for water accumulation. Where 1x-furring strips are added, they should be full depth of the ledger and beveled directing water away from the house (edges should be caulked prior to attachment). Where the house has stucco or lap siding the siding should be removed and the ledger attached directly to the rim joist. Flashing should be added to extend a minimum 1-1/2 inches under the siding and over the ledger. To eliminate the ledger, a beam line can be added 3 feet from the house and the deck cantilevered back towards the house. See detail A. The bottom of piers cannot bear in the foundation back fill. Note: See following diagrams. Revised May 2014 Page 3 of 9

SPAN TABLES Tables are based on the 2012 International Residential Code (IRC) for the species and grade of lumber shown. For other situations consult the tables in the code. Table 1 Floor Joists - 40# LL & 10 #DL Decks Member Species/grade Spacing Max. span 2x6 SP#2 acq 12" o.c. 10 9 2x6 SP#2 acq 16" o.c. 9'9" 2x6 SP#2 acq 24" o.c. 8'6" 2x8 SP#2 acq 12" o.c. 14'2" 2x8 SP#2 acq 16" o.c. 12'10" 2x8 SP#2 acq 24" o.c. 11' 2x10 SP#2 acq 12" o.c. 18' 2x10 SP#2 acq 16" o.c. 16'1" 2x10 SP#2 acq 24" o.c. 13'1" 2x12 SP#2 acq 12" o.c. 21'9" 2x12 SP#2 acq 16" o.c. 18'10" 2x12 SP#2 acq 24" o.c. 15'5" 2x6 Cedar#2 12" o.c. 9'2" 2x6 Cedar#2 16" o.c. 8'4" 2x6 Cedar#2 24" o.c. 7'3" 2x8 Cedar#2 12" o.c. 12'1" 2x8 Cedar#2 16" o.c. 11' 2x8 Cedar#2 24" o.c. 9'2" 2x10 Cedar#2 12 o.c. 15 5 2x10 Cedar#2 16 o.c. 13 9 2x10 Cedar#2 24 o.c. 11 3 2x12 Cedar#2 12 o.c. 18 5 2x12 Cedar#2 16 o.c. 15 11 2x12 Cedar#2 24" o.c. 13' 2x12 Cedar#2 24" o.c. 13' Use the proper fasteners for joist hangers or other metal clips (no screws, roofing nails, non-galvanized fasteners). ACQ lumber requires the use of galvanized, stainless steel, or special-coated fasteners. Table 2 0BDecking - 300# Concentrated Load Member Species/grade Max. span 2x6 SP #2 ACQ 3'-0" 2x6 Cedar #2 2'-6" 5/4x6 SP #2 ACQ 2'-3" 5/4x6 trex 1'-4" Revised May 2014 Page 4 of 9

Table 3 Deck Beam - Span Chart 2BMaximum Beam Span Residential Decks (40 psf live load - /10 psf dead load) Southern Pine ACQ #2 Load Width ( is the portion of the joist span supported by the beam) 1 Beam size 4 5 6 7 8 9 10 11 2x8 6 5 5 2 4 3 3 8 3 2 2 10 2 7 2 4 2-2x8 10 1 9 1 8 3 7 4 6 5 5 8 5 2 4 8 3-2x8 12 10 11 10 10 10 10 9 5 8 6 7 8 7 2x10 8 2 6 6 5 5 4 8 4 1 3 8 3 3 3 2-2x10 12 0 10 9 9 10 9 2 8 2 7 3 6 6 5 11 3-2x10 15 8 14 1 12 10 11 11 11 2 10 7 9 9 8 11 2x12 9 11 7 11 6 7 5 8 5 4 5 4 3 7 2-2x12 14 0 12 7 11 6 10 8 9 11 8 10 7 11 7 3 1. For simple spans the tributary is ½ the joist length for a center beam the tributary is the sum of ½ the span from each side of the beam. Table 4 Maximum Beam Spans - Residential Decks (40 psf live load - 10 psf dead load) Load Width Western Cedar is the portion of the joist span supported by the beam (for simple spans the tributary is 1/2 the joist length - for a center beam the tributary is the sum of 1/2 the span from each side) Beam size 4' 5' 6' 7' 8' 9' 10' 11' 4x10 11'7" 10'5" 9'6" 8'10" 7 11 7' 6'4" 5'9" 6x10 12'8" 11'5" 10'6" 9'9" 9'1" 8'7" 8'2" 7'10" 6x12 15'3" 13'9" 12'7" 11'9" 11'0" 10'5" 9 10 9'5" Table 5 On-center spacing of lag screws (inches) Lag size Joist span (feet) ½ Dia. Lag 0-5 ft 6-7 ft 7-10 ft 11-14 ft 15-18 ft 32 o.c. 24 o.c. 16 o.c. 12 o.c. 8 o.c. Equivalent spacing joists @ 16 o.c. Every other joist Two every third joist s Each joist Each joist with two every other Two in each joist 3/8 Dia. Lag 0-4 ft 5-6 ft 7-8 ft 9-12 ft 13-18 ft Equivalent spacing joists 24 o.c. 16 o.c. 12 o.c. 8 o.c. 6 o.c. @ 16 o.c. Every other joist Each joist Each joist with two every other Two in each joist Two each joist with three every other Table 6 1BPier sizes required for supporting decks Pier diameter Maximum load (pounds) Square footage of deck that can be supported (tributary area) 8 525 11 10 825 17 12 1200 24 14 1600 32 16 2100 42 18 2650 53 20 3300 66 22 4000 80 24 4700 94 Revised May 2014 Page 5 of 9

Pier / Support Pier Location Diagram Column Prefabricated Column Anchor Basement Piers located close to foundation may need to be deeper than 36 X 12 Grade Min. 36-inches to frost line Concrete Pier Elevate minimum 2-inches above grade X Height of grade 45 o 36 Point at which piers need to be deeper than 36 Bottom of deck pier can not bear in foundation back fill Column diameter per Table 6 Minimum 10-inches Handrail Req d on one side with 4 or more risers 34-38 above stair nosing Guardrails Min. 36 height where deck floor exceeds 30 above grade. Max. 4 between each guardrail. Stair Treads 10 min. run 7-3/4 max. rise Concrete landing Handrail Geometry Handrails shall have circular cross-section with diameter between 1-1/4 and 2-5/8 inches. Minimum 1 1/2 clearance between handrail and adjacent framing. Revised May 2014 Page 6 of 9

Revised May 2014 Page 7 of 9

Revised May 2014 Page 8 of 9

B = Beam span C = Joist span load area for posts 20 0 House Wall Joists (typ.) load area on perimeter post C Beams (typ.) Post row 1 16 0 load area on interior post C load area on perimeter post load area on corner post D B Post row 2 load (t) for deck beams A. t = a/2 + b/2 a/2 t b/2 Joist (typ.) Beam (typ.) a b B. t = a/2 + d a/2 t d Overhang, d shall not exceed 3 feet a d Overhang C. t = a/2 + b/2 D. t = a/2 + d t a/2 b/2 a/2 t d a b a d Overhang House Revised May 2014 Page 9 of 9