Introduction of China Telecom Data Center
Largest IDC Service Provider in China More than 300 DCs around the world 10 Tier-4; 198 Tier-3 Total IDC area is over 20 Million square meters One-stop service for IDC & Network Management Toronto Santa Clara Los Angeles Brazil London x 2 Paris Stockholm Frankfurt Dubai 300+ DCs in China Singapore Hong Kong x2 Professional IDC Service Team Sydney with International Certifications Existing Planned BS7799 International Security Certification ISO27001:2 005 ISMS certification National Diamond 5-Star Data Center 2
Agenda China Telecom IDC Overview Introduction of China Mainland Tier-4 IDCs Introduction of the Tier-3 overseas IDCs Why China Telecom 3
Agenda China Telecom IDC Overview Introduction of China Mainland Tier-4 IDCs Introduction of the Tier-3 overseas IDCs Why China Telecom 4
Beijing, China Beijing-Yong Feng Data Center Located in YongFeng High Technology and New Technology Industrial Base Standalone land, Beijing Telecom ownership building; Total area of land: 17,463 Sq.m; Greening rate : 35%; ISO 27001, TL9000 Certification 5
Beijing, China Largest separate DC building in Asia 4 floors over ground, 3 floors under ground Total building space: 44817 Sq.m. Beijing Telecom ownership building Earthquake proof: 8 level; First class fire-retardant ability; First class water-retardant ability; Withstanding the strong storm Honored with the Great-wall Cup Tier IV design standard Separate office building Total area:8571 Sq.m. 2 floors over ground, 2 floors under ground As office loaned to Customers 6
Shanghai, China Shanghai- B1, B2, B7 DC Located in the China Telecom information park (No. 5788, YangGao South Road, Shanghai, China) 3 major international Certification: ISO27001, ISO9001, TL9000 The Center uses top-grade data center standard, stable power facility, advanced chilled cooling system, reliable security measures, complete disaster prevention system, and provides customers with hosting service of quality, stability and reliability. 7
Shanghai, China Hot-aisle/cold-aisle layout to increase the efficiency of the air conditioner chilled cooling system, energy-saving air conditioners 2N redundancy refrigeration equipment N+1 redundancy CRAC 8
Guangzhou, China Total data centre area exceeds 15,000 Square meters; ISO 27001, TL9000 Certification Guangzhou Telecom s real estates with sole property right Supported by excellent municipal planning and facilities Zone with most stable geologic structure Grade one anti-fire structure Clean and tidy surrounding environment without any source of hazards Guangzhou- APIE DC Reference distances 40 kms from the airport, Near the Guangzhou-Shenzhen Expressway 10 kms from GuangzhouDong Railway Station Near subway Line 4 9
ShenZhen, China FuYong DC Shahe DC Shenzhen Telecom the largest IDC service provider in South China; Five major IDCs, Total area 25,000 Sq.m; Customers covering governments, finance, IT, logistics manufacture, etc; LongGan DC 10
ShenZhen, China Nov 22, 2004, obtained TL9000 RAB certification Feb 2, 2005, passed TL9000 Quality Management System authentication Nov. 2006, passed ISO27001 Information Security Management Certification More than 500 employees obtained ITIL Foundation / ITIL Service Manager Certification More than 30 employees passed BCI (Business Continuity Institute) certification test 11
Chengdu, China Chengdu- West Information Center Western information center which is located in Tianfu new city, high tech district of Chengdu, and it covers almost 60,000 square meters area. This program invested 1.8 billion RMB, and the total construction area is about 220,000 square meters. 12
Jiangsu province, China Wuxi- Tech Park DC Nanjing- Hexi DC Suzhou- Jinji Lake DC 13
Agenda China Telecom IDC Overview Introduction of China Mainland Tier-4 IDCs Introduction of the overseas IDCs Why China Telecom 14
HONG KONG IDC-Tier 3 Dual Telecom and Electrical Risers All Fixed Network Operators already accessed to Mega Dedicated mechanical and electrical plant floors Street Power delivered to Mega via three separate Power Company Substation Multiple Diesel Generators with 18,000 KVA capacity Multiple UPS Systems with 6,400 KVA capacity Name of Data Center Mega-iAdvantage 15 Location 399 Chai Wan Road, Hong Kong
SINGAPORE- Tier 3 Only true carrier-neutral facility in Singapore Name of Data Center CTSG IDC Location No 2, Tai Seng Avenue, Singapore 534408 24 resident carriers access to all sub sea cable systems landing in Singapore Blue-chip customer base 16
Santa Clara Data Center Address: 2807 Mission College Blvd, Santa Clara, CA 95054 TIER 3 with N + 1 infrastructure Dual Telecom and Electrical Risers Located in the heart of Silicon Valley, offers customers a premier managed services offering founded on state-ofthe-art infrastructure; The facility infrastructure is also being enhanced by the adjacent construction of a Silicon Valley Power substation; 17
Los Angeles Data Center Address: 600 W 7th Street, Suite 570, LA, CA 90017 Located in downtown Los Angeles, this site benefits from a robust electrical and HVAC infrastructure. It ranks as one of the most prominent technology facilities in the Western U.S. Dual Telecom and Electrical Risers TIER 3 with N + 1 infrastructure Clean and tidy surrounding environment without any source of hazards ; 18
Power and Cooling Santa Clara Data Center Power Density is 5KVA / Rack Two diverse power feeds N+1 Redundant UPS Six 2.5MVA N+1 diesel generators; Diesel fuel: 48 hours at full load Air cooled chiller system Generator Los Angeles Data Center Power Density is 4.8 KVA / Rack Two diverse power feeds N+1 Redundant UPS Two 2.4 MVA N+1 diesel generators; Utility power Diesel fuel: 24 hours at full load Air cooled chiller system 19
Connectivity Carriers/ISPs on-site: International telecom carrier on site China-US direct multi-cable system Low monthly cross connect fees Entrances with Dual Risers CHINA-US DIRECT MULTI-CABLE SYSTEM Dual Diverse Building Fiber MEET ME ROOM 20
Agenda China Telecom IDC Overview Introduction of China-Mainland IDC Introduction of the U.S. IDC Why China Telecom 21
Why China Telecom Abundant Network Capacities - Point of Access: All over the World -ChinaNet, CN2, two IP backbone from US to China can provide best routes connecting with Customers presence in China; Financial Security -Business continuity guaranteed Reliable & Secured Facilities Management -Solid facilities management experience -7x24 in-house technicians to give timely response and problem resolution - True One-Stop-Shop with Colo, Network, and ICT Support 22
Green and Energy-saving Reasonable calculation of the height of raised floors; Cancelled cabinet blind plates; reasonable arrangement of equipment spacing. Aircon Dropped ceiling is arranged to form return-air static pressure box; Adjustment and optimization of aircon positions. Design of doubleglazing wall barrier; combined protection and save energy by light barriers and the air between the two layers of glass. Premise Green Energy- Saving UPS Modularized framework accurately configures operational energy consumption and enhances efficiency of usage. 23
Network Advantages 1 Real-time surveillance of the whole network traffic 2 3 4 Traffic analysis and accurate statistics Route update and optimization throughout the network Interconnection of domestic telecom networks NOC Surveillance Center 24
Information Operation and Management Customer traffic composition analysis Real-time personalized traffic warning Traffic flows, composition analysis Customized traffic analysis report 25
We Look Forward To Working With You! 26