IntesisBox Modbus Server Fidelio IP



Similar documents
IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus RTU master

IntesisBox Modbus Server SAMSUNG Air Conditioners

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox KNX - LON

Modbus Server SAMSUNG Air Conditioners

KNX Panasonic Air Conditioners

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox KNX LG Air Conditioning

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox ASCII Server - LON

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

TX2123 RS485 TO ETHERNET ADAPTOR

TX OPEN RS232/485 module

User manual Compact Web PLC WP240 series IEC-line

PCS0100en Persy Control Services B.V. Netherlands

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

connecdim Gateway G1 Ethernet TCP/IP to DALI

Z-TWS4. Multifunction Straton / LINUX Controller.

One Port Serial Server Users Manual Model ESP901, ESP901E

Telephone- and leased line modem for industrial applications TD-36

IntesisBox. Making Building Automation go further. OPC Servers

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Application/Connection Examples

QSE-CI-NWK-E Control Interface

Rack mounted telephone- and leased line modem for industrial applications

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

MODBUS TCP to RTU/ASCII Gateway. User s Manual

Communication standards and Carel solutions

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

OZS Web server. For LPB/BSB plants

EDI Distributor Control Interface Wiring and Setup Instructions

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Waveguide Access Point WGA631. Product Guide

Loop-IP6702 TDMoEthernet

Electronic Control Devices The European Product Catalogue 2007

Modbus RTU (RS-485) TCP/IP (Ethernet)

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Industrial Bar Code Scanners

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

NetBiter webscada Modbus User Manual

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Job Aid Pre-Installation Information S8500 Media Server

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

TK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Established Leaders in Actuation Technology. Pakscan IIS sequencer master station. Publication S112E issue 09/04

User Manual Revision English

HARTING mcon 1000 Introduction and features

TK800-Series Industrial GPRS / UMTS / LTE Router

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Unidirectional Transmitter/ Receiver Units Introduction

Alcalde # 1822 Col. Miraflores C.P Guadalajara, Jal. Mexico MX 01 (33) y USA 001 (619) (San Diego, CA.

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual


R-Win. Smart Wireless Communication Management System

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

1 Serial RS232 to Ethernet Adapter Installation Guide

ELCOMPONENT LTD. User Manual

RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

How To Run An Nport I5000A Device Server

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

SCADAPack 530E 535E. remote Programmable Automation Controller

s!nus-elektrotechnikai bt. Industrial IT & Automation

Bluetooth HC-06 with serial port module Easy guide

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Modular I/O system Rugged Modular I/O System Solutions EN certified for railway applications

Electronic Control Devices The European Product Catalogue 2007

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

HARTING econ 3000 Introduction and features

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

ATC-2000WF User s Manual

R60 USB to CAN interface Manual (1.5 EN)

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

NEW. EVEN MORE data acquisition and test stand automation

HWg-STE HWg-STE PoE MANUAL

HMI display Installation Guide

EA7-T8C EA7-T10C EA7-T12C EA7-T15C

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

BACnet Automation Interface Module (Network Version)

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

ewon COSY 141 Installation Guide

Transcription:

IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master device or system (SCADA, BMS, PLC, HMI, TouchPanels ). Master TCP TCP Master RTU RTU RS232/RS485 IntesisBox Cylon UnitronUC32 Intesis Box FIAS Interface Fidelio Ho Management system Server LinkBoxMB Configuration Software Only needed for configuration Monitor & Control your Micros Fidelio Ho management system from your Control Center using any commercial SCADA or monitoring software with driver. IntesisBox allows TCP () or RTU (RS232 or RS485) communication, configurable by software. IntesisBox is a server device in case of TCP communication, or a slave device in case of RTU communication. IntesisBox connects to the FIAS interface of the Ho Management system using a TCP/IP connection. Monitoring of the room state (checked in/out) through independent registers. The value in the register indicates the state of the room the state. Fixed address map. The register number identifies the room. Simple configuration, no point's configuration needs to be entered, just the communication parameters (IP address, baud rate ). Up to 1500 rooms are supported IntesisBox Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the registers without the need to be connected to the Ho Management system, very useful while in commissioning phase. 1 / 8

1. Description IntesisBox Server for integration of Micros Fidelio Ho management system Order Code Description IBOX-MBS-FIDELIO_IP This gateway allows integration of Micros Fidelio Ho management system into a master device or system. The gateway acts as a slave device. Main features Software for configuration and test is supplied with the gateway. Through the user interface, it is allowed to simulate the status of the registers without the need to be connected to the Fidelio system Allows to be mounted on DIN rail, wall or desktop. Power from 9 to 30Vdc or 24Vac (Power supply supplied) features TCP or RTU over RS232 or RS485 selectable. Parameters configurable: IP address, slave number, baud rate, etc. functions supported: 03 & 04 for read, 06 for write. The registers are all Unsigned Int, read only registers from 1 to 1500 can be used. Each register is the status of a single room Fidelio features Connected over TCP/IP Needs the FIAS interface Up to 1500 rooms can be supervised 2 / 8

2. Sample applications Integration of Fidelio s Ho management system in any control systems. Master TCP Master RTU RTU RS232/RS485 TCP IntesisBox Server Cylon UnitronUC32 Intesis Box FIAS Interface Fidelio Ho Management system control system: Building Automation. SCADA. HMI TouchPanels Programmable Logic Controllers (PLC)... Fidelio Ho Management system... MODBUS System monitoring / controlling Full monitoring and control Fidelio System under supervision / control 3 / 8

3. Typical application Monitor & Control of Fidelio s Ho management system from a Control Center using any commercial SCADA or monitoring software with TCP driver. SCADA with TCP master driver LAN WAN INTERNET TCP RS232 Fidelio Ho management system 4 / 8

4. interface of IntesisBox Description IntesisBox acts as a slave device in its interface, this interface can be the port (if using TCP), or the RS232 port or the RS485 port (if using RTU). To access the points of the IntesisBox from system, you must specify as the register addresses those configured in the LinkboxMB. Register s addresses and values The registers to be used with the IntesisBox Server FIDELIO IP gateway are all Unsigned Int, read only and the values from 1 to 1500 can be used. The allowed values of the registers are: 0: room in check-out status 1: room in check-in status There is a communication error register showing the communication status of the IntesisBox with the Fidelio system with the values: 0: Communication OK 1: Error in the communication Functions supported functions 03 and 04 (read holding registers and read input registers) can be used to read registers. If poll records are used to read more than one register, it is necessary that the range of addresses requested contains valid addresses; if not the corresponding error code will be returned. error codes are fully supported, they will be sent whenever a non valid action or address is required. 5. Fidelio interface of IntesisBox The IntesisBox connects to the Fidelio system, using TCP/IP. More concrey, to the FIAS interface to get the updates of the room status. Also it can re-synchronize with the current status of all the rooms. It allows to supervise the status (checked in / checked out) of up to 1500 rooms. 5 / 8

6. Configuration tool LinkBoxMB Visual engineering tool, easy of use, for gateway s configuration and supervision compatible with Microsoft Windows operating systems, supplied with the gateway free of charge. Multi-window tool allowing to supervise simultaneously the communication activity with both protocols (systems), real time values for all the signals allowing to modify any value (very useful for test purposes), console window showing debug and working status messages, and configuration windows to configure all the gateway s parameters and signals. Signals configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the gateway s parameters and signals while in off-line (not connected to the gateway). Connection to the gateway for download the configuration and supervision by using serial COM port of the PC (serial cable supplied with the gateway). Allows configuring all the external protocols available for IntesisBox Server series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox Server series. Multi-project tool allowing having in the engineer s PC the configuration for all the sites with different IntesisBox Server series gateways. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the gateway for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ). 6 / 8

7. Mechanical & Electrical characteristics Plastic, type PC (UL 94 V-0). Enclosure Dimensions: 107mm x 105mm x 58mm. Colour Light Grey. RAL 7035. 9 to 30Vdc +/-10%, Max.: 125mA. 24Vac +/-10% 50-60Hz, Max.: 127mA Power Must use a NEC Class 2 or Limited Power Source (LPS) and SELV rated power supply. Plug-in terminal block for power connection (2 poles). Terminal wiring (for power supply and low-voltage signals) Mounting RTU ports Per terminal: solid wires or stranded wires (twisted or with ferrule) 1 core: 0.5mm 2 2.5mm 2 2 cores: 0.5mm 2 1.5mm 2 3 cores: not permitted Wall. DIN rail EN60715 TH35. 1 x Serial EIA232 (DB9 male DTE). SELV 1 x Serial EIA485 (Plug-in screw terminal block 2 poles). SELV TCP and FIDELIO (TCP/IP) 1 x 10Base-T RJ45. 1 x Power. LED indicators 2 x RTU serial port activity (Tx, Rx). 2 x port link and activity (LNK, ACT). Console port EIA232. (DB9 female connector, DCE). SELV Configuration Via console port. 1 Firmware Allows upgrades via console port. Operational temperature 0 C to +70 C Operational humidity 5 to 95%, non condensing Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). Norms and standards CE conformity to EMC directive (2004/108/EC) and Low-voltage directive (2006/95/EC) EN 61000-6-2, EN 61000-6-3, EN 60950-1, EN 50491-3 1 Standard cable DB9male-DB9female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device. The configuration software, compatible with Windows operating systems, is also supplied. 7 / 8

8. Dimensions Power + port Fidelio port RTU RS232/485 58 mm Console port 107 mm 105 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections 100 mm 130 mm 115 mm 8 / 8