Building Code Clarifications - 7. Fire Resistance



Similar documents
Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

The replacement or modification of existing windows shall comply with the following requirements:

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

BUILDING PERMIT SPECIFICATIONS

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Number of Sides Required to Have a Handrail

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Certification: Building Plans Examiner. Exam ID: B3

Building Control Guidance Note

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

General Fire Code Requirements Within Commercial Tenant Spaces

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

FIRE-RESISTANCE-RATED CONSTRUCTION

FIRE-RESISTANCE-RATED CONSTRUCTION

Excerpts from the Canadian National Building Code (NBC)

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Residential Decks. Planning and Development Services Department

- 5 - Table1. Maximum Compartment Volumes

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

St. John s University

Development Services City of Lawrence, KS

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Residential Deck Safety, Construction, and Repair

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

FIRE AND SMOKE PROTECTION FEATURES

Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Indiana Building Rehabilitation Standard

2010 FLORIDA BUILDNG CODE, FIRE AND LIFE SAFETY i

FARMERS MUTUAL INSURANCE COMPANY UNDERWRITING GUIDELINES HOMEOWNER PROGRAM

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

Single Family Residential Basement Finish

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Barriers & Fire Stopping

Current as of 11/10/08 1 of 1

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

CHAPTER 6 CONSTRUCTION TYPES

FIRE AND SMOKE PROTECTION FEATURES

New York City Department of Buildings

SUBCHAPTER 5 FIRE PROTECTION CONSTRUCTION REQUIREMENTS

How To Build A Basement House

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Building Condition Assessment Report

Solar Panel Installations

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

Sample Drawing Package for One and Two Family Dwelling Applications

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Arapahoe County Residential Water Heater Installation and Inspection Guide

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

WINDOW AND DOOR REPLACEMENT REQUIREMENTS


NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

Name Of Occupancy Date. Yes No Describe

17,280 square feet Overview:

The 60 minute Fire Rated Application Explained

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

Decree of the Ministry of the Environment on fire safety of ventilation systems

Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)

Spray Booth Guideline

Property Maintenance Check List

4 Installation Requirements

Facility Assessment for East Main Street, Huntley, IL

Pollution CO CO 2. Carbonaceo us soot H 2 S, NOX, SO2

Walking and Working Surface Checklist:

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

6. GIVE FULL DETAILS OF TYPE OF WORK, OPERATIONS AND ATTACH BROCHURES IF APPLICABLE:

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

Applications for building permits will not be reviewed until all of the required information has been submitted.

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

Fire-Rated Glass and Glazing START

FARMERS MUTUAL INSURANCE COMPANY UNDERWRITING GUIDELINES CITY FIRE PROGRAM UNDERWRITING ITEMS OF IMPORTANCE

CITY OF TORONTO. BY-LAW No

How To Make A House Safe

City of Bettendorf Fire Alarm System Requirements

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

Wood use in Type I and II (noncombustible) construction

SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST

Residential Plan Routing Information

Arizona Health Care Association DISASTER PLANNING AND EMERGENCY MANAGEMENT GUIDE POST INCIDENT DAMAGE ASSESSMENT CHECKLIST

ATI Evaluation Service A Division of Architectural Testing Certification Services

G SPECIFICATION: GAS METER AND REGULATOR INSTALLATION REQUIREMENTS. 3 and Gas Yellow Book. REVISIONS: (See ) 1/15/14 5 Years

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

BUILDING SAFETY UNIT

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

Schedule B to By-law Part A Fees Payable for Permits

Transcription:

Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000, in conjunction with other code sections to allow the use of Exterior Insulation finishing Systems (EIFS) on buildings. The intention of this revision was to allow this combustible insulation on the exterior walls of buildings of construction Types I, II & III. Previously, per Chapter 13-60, exterior walls of those construction types were required to be constructed entirely of noncombustible materials with the applicable fire ratings. The revision of Code Section (15-12-030) was intended to require only the structural components to be noncombustible and fire rated. EIFS is not a structural component so it was not required to be noncombustible. It was not intended to change the requirements of Chapter 13-60 to now require a noncombustible roof assembly in Type III construction. Type III construction has always been allowed to have a combustible roof assembly with an applicable fire rating when required. Therefore, buildings of Type III construction are NOT required to have noncombustible roof assemblies. 7.2 (15-8-322) Wood frame balconies An unprotected wood frame balcony shall be permitted on buildings of construction Types III and IV. They must conform to the requirements of the Section (15-8-322). The Code Section (15-8-310) shall not be applicable to building construction Types III and IV. 7.3 (15-8-210) Combustible material used to enclose heating equipment & (15-8-220) rooms in Types III & IV construction In buildings of types III and IV construction, the use of wood is permitted for the interior framing of the walls, floors and ceilings in accordance with the Sections (13-60-060), (13-60-070) and (15-8-260)(c). Therefore, wood framing or wood studs shall be permitted for the enclosure of space heating equipment rooms located in the buildings of types III and IV construction. The hourly fire rating shall be in accordance with the Sections (15-8-210) and (15-8-220). 7.4 (15-8-520) Skylights and sloped glazing The use of laminated glass roof panel in atria and skylights has been approved in many installations. Tempered glass has not been approved since it fragments and falls when a concentrated (impact) load is applied.

Therefore, only wire glass or laminated safety glass shall be specified for all skylights and sloped glazing applications. Tempered glass may be used in double glazed installations only with wire glass or laminated safety glass as the lower layer. 7.5 (15-8-110) Protection of openings Building inspections have recently shown that many existing buildings do not comply with Section (15-8-110). Any building plan which is reviewed must show compliance with the Section (15-8-110). Section (15-8-110) requires fire rated windows for buildings on interior lot lines, near fire escapes and other locations. All design professionals must be aware of situations when fire rated windows are required per Section (15-8-110). 7.6 (15-12-160) Size of fire rated windows Sections (15-12-160) through (15-12-250) address all of the requirements needed for fire rated windows. Depending on the type of window being used, Sections (15-12-210) and (15-12-220) give the maximum size restrictions for that specific type of window. However, Section (15-12-240)(b) also allows windows of other sizes to be used, provided that these windows meet all of the required test standards that the code requires. Therefore, fire rated windows of any size can be used provided that the actual window being used meets all of the required test standards. These test standards are stated in Sections (15-12-170) through (15-12-200). Without special testing, the use of fixed wire glass vision panels is permitted in one hour fire rated interior walls, provided each pane does not exceed 1,296 square inches in area having a maximum dimension of four feet, six inches and is installed in a 16 gauge steel frame. Wire glass when used for the exterior wall opening protection shall not exceed 720 square inches per piece and shall be in a 16 gauge steel frame. 7.7 (15-8-110) Fire rated windows and the Energy Code Fire rated windows are required by code to protect openings in buildings per code section (15-8-110). These windows provide a 45 minute fire rating which includes a hose stream test. These windows can be required along interior lot lines or near fire escapes, exterior stairs and other locations. Fire rated windows protect the building s exposure from fire, and also protect the building s occupants and firefighters when using a fire escape during a fire incident. It is agreed that, whenever the Municipal Code requires fire rated windows to be installed, this life safety requirement must be met. The new Energy Code will not supersede this requirement. The requirements of the energy code will need to be met in other ways.

7.8 (15-8-160) Enclosure of pipe shafts and ducts Per Section (15-8-160), when pipes and ducts pass through floor openings less than nine square feet in area, no fire rated enclosure is required regardless of the construction type of the building. All that is required is that the openings between the floor and the pipes or ducts be filled with noncombustible materials. On building plan reviews, only a general note stating compliance with this code section will be required. A detailed drawing is not needed, nor is it required by code. This shall be for any pipe, flue or duct passing through a floor opening which is less than nine square feet in area. 7.9 (15-8-200) Enclosure of heating plants & boilers Section (15-8-200) clarifies when a fire rated enclosure is not required for heating plants and boilers. Steam boilers have a pressure rating exceeding 15 psi. They are not included in this section, but instead are covered under section (13-8-210). Heating plants with pressure rating less than 15 psi can be viewed as forced air furnaces. The enclosure of furnaces or boilers shall not be required for one story business, mercantile, industrial or storage units having a floor area not exceeding 3000 sq. ft. This section refers to the size of the unit or tenant space and not to the building size. Therefore, a storage occupancy that only occupies any one story of a building (this could be a multi-story building) and with a tenant area not exceeding a 3000 sq. ft. is not required to have a fire rated enclosure around its furnace. This shall be the same for a business, mercantile, or industrial occupancy that meets this unit size requirement. 7.10 (15-8-180) Stairwell enclosure - Nonessential openings Code Section (15-8-180) does not prohibit the penetration of electrical conduit into the stair enclosure. These conduits can be used to power the lighting within the stairwell or the building fire alarm system. The conduits that penetrate the stair enclosure shall be fire stopped properly with a non-combustible material. However, the HVAC air ducts are not permitted to cut through a stairwell enclosure, with or without duct openings within the stairwell. 7.11 (15-8-140) Convenient stairway enclosures The following stairway enclosure requirements apply to the convenient stairways that serve the floor levels that are occupied by one tenant or the floor levels served are under control of one management or ownership:

One-hour enclosure is required for the stairways that serve any two or three floors of a building and two hour enclosure is required when four or more levels are served. The one hour stairway enclosure walls can have fixed wired glass vision panels, provided each light does not exceed 1,296 square inches in area having a maximum dimension of four feet, six inches and is installed in a 16 gauge steel frame. One and two hours fixed ceramic glass is also permitted in one and two hours stairway enclosures. The dimensions allowed are strictly by manufactures specifications. When serving only two floors, a complete stairway enclosure is required only on one level, upper or lower, with one-hour walls and 1½ hour self-closing B label door. A note is required on the plans that the stair door is not permitted to be held open. Enclosure on both levels is required when stair doors are held open by magnetic door hold open devices and smoke detectors are installed in accordance with the Section (15-8-180)(c). Except in Residential and Institutional occupancies, the enclosure of a stairway serving only the second floor from the ground floor is not required in buildings of Fire Resistive Construction (Type 1 construction). Compliance with the High Rise Chapter 13-76 and installation of atrium smoke control system is required if stairway enclosure is not provided for non-required stairways. 7.12 (15-8-140)(b) Convenient stairways - No enclosure required Stairway enclosure shall not be required for the stairway serving any two floors in buildings of Type I-A, I-B, and I-C construction with the following conditions: 1. The entire building is protected by an automatic sprinkler system. 2. The open stairway is not used as a required exit, except where permitted by the Section (15-8-140)(b)&(c). 3. The occupancy of the floors served by the open stairway is not Hazardous Use, Multiple Dwellings, or Institutional Use. 4. All shafts within 100 feet horizontal distance from the unenclosed stairway opening, on both levels, have minimum one (1) hour enclosure, except the shafts for pipes and ducts passing from one floor to the other as per section (15-8-160). This ruling is based on the fact that Section (15-8-140)(b) allows stairway between two floors, between the ground floor and the second floor, without any enclosure, and with the life safety features and restrictions in place, it can be any two floors of the building. 7.13 (15-8-323) Weather protected entries As of this date, small entry porches (weather protected entries) on single family homes are not required to comply with the porch standards and/or are not required to apply for a building permit for repair or replacement. The entry porches governed by this memorandum must be less than 50 square feet in area, excluding the steps, and a

maximum of six feet above ground level for the floor of the porch. The entry porch may be covered (weather protected entry - code section (15-8-323)) or uncovered (stoop). 7.14 (15-8-320) Clarifications concerning combustible porch materials Code section 15-8-320 requires that new construction porches of combustible construction be located six feet (6-0 ) from an interior lot line. In addition, exception 2 of this section allows combustible residential front porches not exceeding 200 square feet in area and one story in height to be located within three feet of the interior lot line. The department has received many inquiries asking if the use of new synthetic wood products, fire-retardant treated wood or the use of a hybrid porch construction using noncombustible metal columns and beams with an infill of wood joists and / or wood decking qualify the porch as non-combustible construction. Section 15-12-040(a) defines a combustible material as a material which will ignite when heated to a temperature of 1200 degrees Fahrenheit or less. At this time, The Department is not aware of a synthetic or recycled wood or plastic material used as decking or structure which meets this temperature criterion for non-combustible construction. Therefore porches with synthetic plastic or wood decking or other members would be classified as combustible construction. Based on the same criterion, the Department of Buildings and the Chicago Fire Department do not recognize fire-retardant treated wood as non-combustible. While fireretardant treating may temporarily delay the onset of combustion, it does not render a wood product as permanently non-combustible. Furthermore, both departments note that fire-retardant treated wood used in exterior applications will more quickly lose its chemical properties of fire-retardant treatment owing to exposure to weather and U.V. degradation. Therefore, porches using exterior fire-retarded treated wood are classified as combustible porches. Finally, porches using a combination of non-combustible and combustible elements such as steel perimeter beams and columns with an infill of wood joists and / or wood decking do not meet the requirements of code section 13-60-030 (Type II Non- Combustible Construction) which states that Non-combustible construction shall be that construction in which all structural elements are of non-combustible materials. Therefore, only if a porch is constructed with all non-combustible structural elements (foundations, columns, beams, joists, decking, stringers, treads, risers, guardrails, handrails, rafters and roof decking) is it considered to be non-combustible.. 7.15 (15-8-322) Clarification of the definition of balcony A balcony is defined as an open unheated floor cantilevered from or supported by a building, and open to the atmosphere on at least one side. To clarify when the requirements for a balcony are applicable versus the requirements for a deck or a porch, a balcony is further defined as being attached directly to the side of a building

and supported either by the building or by the ground. A balcony located above the roof of a building can not be supported by the roof of a building. Such an open unheated floor shall be defined as a deck. Additionally, a balcony can not contain a means of exiting from the balcony other than through the building to which it is attached. If one is able to exit directly to the outside and away from the building, then this space is no longer a balcony and must meet the requirements of either a deck or a porch as applicable. 7.16 (15-8-150) Clarification of elevator enclosures This code section requires two-hour fire rated enclosures for elevator shafts and dumbwaiters. Within a single family residence no fire separations are required within the residence. Therefore, any elevator or dumbwaiter serving a single family residence or a single dwelling unit and contained exclusively within that unit is not required to have a fire rated enclosure. An elevator or dumbwaiter serving more than one dwelling unit or serving one dwelling unit and any other occupancy is required to meet the requirements of section 15-8-150.