Biomedical applications of polypyrrole microactuators: from single-cell clinic to microrobots



Similar documents
Fabrication Challenges for Point-ofcare Diagnostics and Organ-on-chip

Sandia Agile MEMS Prototyping, Layout Tools, Education and Services Program

Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator

Silicon-On-Glass MEMS. Design. Handbook

Why silicon MEMS? Silicon is a strong material... Photolithography. Micromachining. Dicing and packaging

Micro-Power Generation

Etching Etch Definitions Isotropic Etching: same in all direction Anisotropic Etching: direction sensitive Selectivity: etch rate difference between

Solar Photovoltaic (PV) Cells

Fabrication of Complex Circuit Using Electrochemical Micromachining on Printed Circuit Board (PCB)

Rapid Prototyping and Development of Microfluidic and BioMEMS Devices

MEMS Processes from CMP

Miniaturizing Flexible Circuits for use in Medical Electronics. Nate Kreutter 3M

Chalmers Publication Library

Photolithography. Class: Figure Various ways in which dust particles can interfere with photomask patterns.

Supporting Online Material for

Microstockage d énergie Les dernières avancées. S. Martin (CEA-LITEN / LCMS Grenoble)

Good Boards = Results

Graduate Student Presentations

Case Study 2: Digital Micromirror Devices (DMD) Optical MEMS

Chem 1721 Brief Notes: Chapter 19

Contamination. Cleanroom. Cleanroom for micro and nano fabrication. Particle Contamination and Yield in Semiconductors.

Le nanotecnologie: dal Laboratorio al Mercato. Fabrizio Pirri Politecnico di Torino Istituto Italiano di Tecnologia

Fig. 1. Background. Name: Class: Date:

Leghe a memoria di forma come tecnologia di attuazione per la biorobotica

The Electrical Control of Chemical Reactions E3-1

Conductivity of silicon can be changed several orders of magnitude by introducing impurity atoms in silicon crystal lattice.

IBS - Ion Beam Services

Printed Circuits. Danilo Manstretta. microlab.unipv.it/ AA 2012/2013 Lezioni di Tecnologie e Materiali per l Elettronica

Introduction to VLSI Fabrication Technologies. Emanuele Baravelli

Introduction to Microfluidics. Date: 2013/04/26. Dr. Yi-Chung Tung. Outline

Electromouillage réversible sur nanofils de silicium superhydrophobes

Lecture 030 DSM CMOS Technology (3/24/10) Page 030-1

Supporting information

OPTIMIZING OF THERMAL EVAPORATION PROCESS COMPARED TO MAGNETRON SPUTTERING FOR FABRICATION OF TITANIA QUANTUM DOTS

CIRCUITS AND SYSTEMS- Assembly and Printed Circuit Board (PCB) Package Mohammad S. Sharawi ASSEMBLY AND PRINTED CIRCUIT BOARD (PCB) PACKAGE

Fabrication and Manufacturing (Basics) Batch processes

Nanotechnologies for the Integrated Circuits

Biaxial tripod MEMS mirror and omnidirectional lens for a low cost wide angle laser range sensor

III. Wet and Dry Etching

Damage-free, All-dry Via Etch Resist and Residue Removal Processes

Dry Film Photoresist & Material Solutions for 3D/TSV

Chemical Reactions During Wet-Etching Process of LSMO/PZT/LSMO-Structured Device Fabrication

Light management for photovoltaics. Ando Kuypers, TNO Program manager Solar

Coating Thickness and Composition Analysis by Micro-EDXRF

Galvanic cell and Nernst equation

Flex Circuit Design and Manufacture.

ENS 07 Paris, France, 3-4 December 2007

Amorphous Silicon Backplane with Polymer MEMS Structures for Electrophoretic Displays

PIEZOELECTRIC FILMS TECHNICAL INFORMATION

T.M.M. TEKNIKER MICROMACHINING

Sensors for plastic manufacturing Solutions in partnership from a single source

ELECTROCHEMICAL CELLS

OLED display. Ying Cao

Microlenses immersed in nematic liquid crystal with electrically. controllable focal length

Focused Ion beam nanopatterning: potential application in photovoltaics

Coating Technology: Evaporation Vs Sputtering

Redox and Electrochemistry

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

A novel MEMS platform for a cell adhesion tester

Femtosecond laser-induced silicon surface morphology in water confinement

Modification of Pd-H 2 and Pd-D 2 thin films processed by He-Ne laser

MEMS devices application based testing

CS257 Introduction to Nanocomputing

Development of High-Speed High-Precision Cooling Plate

Design and Simulation of MEMS Vibration Sensor for Launch Vehicles

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

Name Electrochemical Cells Practice Exam Date:

Through-mask Electro-etching for Fabrication of Metal Bipolar Plate Gas Flow Field Channels

A Practical Guide to Free Energy Devices

FLEXIBLE CIRCUITS MANUFACTURING

Laboratorio Regionale LiCryL CNR-INFM

Adsorption at Surfaces

Balancing the Electrical and Mechanical Requirements of Flexible Circuits. Mark Finstad, Applications Engineering Manager, Minco

Flexible Mehrlagen-Schaltungen in Dünnschichttechnik:

COMP175: Computer Graphics. Lecture 1 Introduction and Display Technologies

Winbond W2E512/W27E257 EEPROM

QUASAR ELECTRONICS KIT No ELECTRONIC MOSQUITO REPELLER

Operator Quick Guide EC SENSOR

How compact discs are made

Improved Contact Formation for Large Area Solar Cells Using the Alternative Seed Layer (ASL) Process

Grad Student Presentation Topics PHGN/CHEN/MLGN 435/535: Interdisciplinary Silicon Processing Laboratory

Demonstration of sub-4 nm nanoimprint lithography using a template fabricated by helium ion beam lithography

Chapter 6 Metal Films and Filters

Sputtered AlN Thin Films on Si and Electrodes for MEMS Resonators: Relationship Between Surface Quality Microstructure and Film Properties

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Formation of Oriented Fibers Using Injection of PEO Solutions inside Electric Fields Defined by Two Parallel Suspended Electrodes

Dry Etching and Reactive Ion Etching (RIE)

Abrasive-Flow Machining

Rigid-Flex Technology: Mainstream Use but More Complex Designs by John Isaac October 1, 2007

Microvitae présente 4 communications à l'e-mrs, mai 2012, Strasbourg

Reaction Engineering of Polymer Electrolyte Membrane Fuel Cells

Electroplating with Photoresist Masks

Chapter 21a Electrochemistry: The Electrolytic Cell

Implementation Of High-k/Metal Gates In High-Volume Manufacturing

This paper describes Digital Equipment Corporation Semiconductor Division s

Extending Rigid-Flex Printed Circuits to RF Frequencies

Deposition Overview for Microsytems

Emerging new non conventional tools

ac Impedance Characteristics and Modeling of Polymer Solution Light-Emitting Devices

Transcription:

Biomedical applications of polypyrrole microactuators: from single-cell clinic to microrobots Edwin Jager, Charlotte Immerstrand, Karl-Eric Magnusson, Olle Inganäs and Ingemar Lundström Linköping University Post Print N.B.: When citing this work, cite the original article. Original Publication: Edwin Jager, Charlotte Immerstrand, Karl-Eric Magnusson, Olle Inganäs and Ingemar Lundström, Biomedical applications of polypyrrole microactuators: from single-cell clinic to microrobots, 2000, 1st Annual International, Conference On Microtechnologies in Medicine and Biology. 2000, 58-61. http://dx.doi.org/10.1109/mmb.2000.893741 From the 1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine & Biology, Lyon, France, October 12-14, 2000 Copyright: IEEE http://www.ieee.com/ Postprint available at: Linköping University Electronic Press http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-75794

Biomedical Applications of Polypyrrole Microactuators: From Single-Cell Clinic to Microrobots Edwin W.H. Jager (1,*), Charlotte Immerstrand (2), Karl-Erik Magnusson (2), Olle Inganäs (1), Ingemar Lundström (1) (1) Div. of Applied Physics, Dept. of Physics and Measurement Technology, Linköpings universitet, S-581 83 Linköping, Sweden, fax: +46-13-288969 (2) Div. of Medical Microbiology, Dept. of Health and Environment, Linköpings universitet, S-581 85 Linköping, Sweden, fax +46-13-224789 * Corresponding author, e-mail: edjag@ifm.liu.se Abstract - Microtools that will be useful for the positioning and investigation of biological microstructures must operate under biologically relevant environments, such as cell culture media or blood plasma. They must also be comparatively strong, and preferably allow a muscle like mode of movement. This is given by a novel family of actuators based on conjugated polymers (like polypyrrole, PPy). By miniaturising these structures using standard photolithographic techniques, we can reduce the size down to 10-micrometer dimensions and build mechanically active microdevices. These can be moved and positioned by applying a potential to dope or undope the PPy. These novel structures are now being developed as a unique microactuator technology, suitable for operation in applications coupled to cell biology and biomedicine. I. INTRODUCTION The miniaturization of electronics has paved the way for miniaturization in other areas of technology, and has now reached the area of cell biology. Tools for investigations of single cells offer potential for new discoveries; tools for moving, positioning and mechanically manipulating cells and organelles and larger biological structures are necessary in the coming generations of microtechnology for medicine and biology. Microactuators of this kind must be able to operate in biological fluids, and must therefore be compatible with aqueous environments. Among the candidates for these functions we find laser tweezers, shape memory alloy structures and also polymeric electrochemical devices. Most of these are still operated with the help of the human eye, through some imaging method, but there is also a need for massive parallelism in the investigation of many individual elements, such as cell sorting. Here microtechnology may lend a hand, or rather a microrobot arm. II. PPY-MICROACTUATORS Conducting polymers like polypyrrole (PPy) are suitable materials for artificial muscles. PPy undergoes a volume change, driven by redox processes accompanied by ion movement. This volume change is reversible. Combining the PPy with a support and/or electrode layer into a bilayer we can make actuators [1-3]. These actuators are operated in a liquid electrolyte (salt solution). Our microactuators are based on an Au/PPy bilayer in which the Au acts both as a structural layer and electrode. When we apply a positive potential to the Au electrode, we remove electrons from the PPy and oxidise it from its neutral state (PPy 0 ) to its oxidised state (PPy + ). This is a reversible process: we can reduce PPy from its oxidised state back to its neutral state by adding electrons. In analogy to the doping of silicon, the oxidised state is often called doped and the neutral state undoped. We use PPy doped with DBS - (dodecylbenzenesulfonate) anions (PPy(DBS)) and operate the microactuators in an aqueous salt solution, usually NaDBS. However, the microactuators function also in other biological more relevant media, like blood plasma, urine, and cell culture media. During reduction of the PPy layer, small cations, in our case Na + (surrounded by a layer of water molecules, the hydration shell), are inserted into the PPy to achieve charge neutrality in the PPy film. The film swells and thus the bilayer straightens. On oxidation, the Na + ions are expelled from the film, which shrinks and results in a bending motion [4]. We can summarise this redox reaction as follows: PPy + (DBS - ) + e - + Na + (aq) PPy 0 (DBS - Na + ) (1) For PPy(DBS) we achieve the neutral state at an applied voltage of V = -1 V vs. Ag/AgCl and the oxidised state at V = 0 V. By choosing a potential between the two limits (completely oxidised or completely reduced), we can position the microactuators at any intermediate position. It is also possible to move the actuators between intermediate positions, for instance from -0.4V to -0.6V and back to - 0.4V. III. FABRICATION For the fabrication of the microactuators we used standard surface micromaching technology. As a substrate we used a Si wafer, and if we needed an insulating surface we used glass or a wafer with a 1 µm thick thermal oxide layer. We could use two different fabrication methods to release the microstructures: differential adhesion [5] or a sacrificial layer. The differential adhesion method is based on the poor adhesion of Au to Si or SiO 2. On the substrate we thermally

evaporated a thin layer (typically 200 Å) of Cr and Au: the adhesion layer. In this layer we patterned squares from which we etched the Cr/Au until we had a bare Si surface again, see Fig. 1a. These squares would be the areas where the microactuators would be free. Next, we evaporated a second, thick (usually 1000 Å) Au layer: the structural layer (Fig. 1b.). Then we electropolymerised the PPy on the Au surface from a 0.1 M NaDBS and 0.1 M pyrrole solution at a constant potential (between 0.5 V and 0.6 V vs. Ag/AgCl), as is shown in Fig. 1c. If the Au layer was 1000 Å thick, we grew a 1µm thick PPy layer. There were two ways to pattern the PPy. Either we grew the PPy on the whole Au covered wafer and then etched the PPy using reactive ion etching (RIE), or we covered the wafer with photoresist in which we had opened holes in which the PPy could grow. Next, we patterned photoresist and etched the structural Au to form the microactuators. As can be seen in Fig. 1c-d, a short piece of the microactuators laid on top of the Cr/Au adhesion layer. This was the anchor that kept the actuator on the surface. Most of the actuator laid on the bare Si. After we stripped the photoresist used for the final Au etch, the actuators were finished, but still attached to the surface (Fig. 1d). They would release themselves during the first activation cycles. For more details on the fabrication of the PPy microactuators we refer to [6]. Fig. 2 Process steps for microactuator fabrication with the sacrificial layer method. a. Depositing and patterning the sacrificial layer, in this case CVD-SiO 2 b. Thermal evaporation of the Cr and Au. c. Electropolymerisation and patterning of PPy. d. Etching the Au and Cr, and underetching the sacrificial layer to release the actuators. We only described the fabrication of simple bilayer actuators (fingers), but it is more interesting to give the actuators some functionality and make devices. One can add rigid elements to make moving plates [7] and selfassembling boxes [8]. With other micromachined structures the possibilities increase. One could create valves [9], switches, grippers, robots, etc. IV MICROROBOT For the handling of small samples, like single cells, or microbeads coated with chemicals, proteins, etc., we have developed a microrobot arm [10]. The arm was built from PPy/Au microactuator joints together with rigid elements (Fig. 3). Each joint could be separately addressed. By applying a voltage we controlled the bending angle of each joint and in this way we could control the movement of the microrobot. Fig. 1 The process steps to fabricate microactuators using the differential adhesion method. a. Depositing and patterning Cr/Au. b. Evaporating Au c. Electropolymerisation and patterning of PPy. d. Final result after etching the structural Au. In some applications, like the microrobot, also other materials than Au were in contact with the Si substrate. As these materials adhered well to the Si, we could not use the differential adhesion method. Therefore we also developed a sacrificial layer method. First, the sacrificial layer (for instance SiO 2 on a Si substrate) was deposited and patterned, see Fig. 2a. Then we thermally evaporated the Cr adhesion layer and the Au structural layer (Fig.2b.). Next, PPy was deposited in the same manner as above (Fig. 2c.). Then we patterned the microactuators by etching the Au and Cr. To release the structures, the sacrificial layer was removed. Fig. 2d shows the final result. The actuators were now free and could be activated. Fig 3. A top view picture of the microrobot. The robot has elbow joints, wrist, and 3 fingers. We used the robot to grab, lift, and move 100µm glass beads. We have also made a track system of polyurethane at the base of the robot using microinjection moulding in capillaries (MIMIC). Using the robot arm, we then moved the bead sequentially all over the tracks, from track 4, to 2, to 1, to 3, and from the tracks to the base of the robot. Fig. 4 shows the robot with the bead on track 3 and 1. The maximum displacement of the glass bead was 270µm.

Fig.4 A microrobot arm (670 µm long and 240 µm wide) moves a 100 µm glass bead over a polyurethane track system made by MIMIC. Rather than glass beads single cells could be easily manipulated. We believe that these microrobots are most interesting for operation in biological fluids. An application of the robot could be for multi station single cell diagnostics. The robot arm could arrest biological entities (single cells, bacteria, multi-cellular organisms, etc) from a sample and then transfer them sequentially to different measurement stations of a multisensor area as we demonstrated by transferring of the glass bead over the tracks. As an example an array of standing microrobots, where the fingers are treated with adhesion molecules, could be used to fish out given cells or bacteria in a sample, and then transfer them to the multisensor area. The testing could also be done by small additional structures on the microrobot itself, such as an extra electrode for electrical measurements or the electrodes could be located on the chip itself, e.g. in microvials (see section V), which could also enable single cell chemical modifications. In medicine, the robot could be used as a tool for minimal invasive surgery. A small robot put on a catheter would increase the range of the surgeon. V. SINGLE-CELL CLINIC Not only do we want to manipulate single cells, we would also like to characterise them. For this purpose we are developing a (single-) cell clinic. This is a micrometersized cavity, or microvial, with a lid. The lid is activated by hinges made of PPy-microactuators, so that the cavity can be opened and closed on demand. Inside the cavity, sensors and actuators can be placed to stimulate the cells and record their responses (Fig. 5). In the cell clinics presented here we have put a pair of Au electrodes on the bottom of the microvial in order to do impedance measurements. In this way we can test cells in a confined volume. Fig. 5 A sketch of the sealable microvial including sensors and actuators on the bottom of the microvial. In the left corner a cell is introduced into the "cell clinic" in order to be studied On a glass substrate we first patterned the Au electrode structure. Next, we made the microvials in a 20 µm thick layer of SU-8. Then, we electropolymerised the PPy layers and finally we etched the complete layout, including the lids, wires and contact pads. Fig 6 (top) shows a photograph of four microvials of which one is closed by a lid. Fig 6 (bottom) shows microvials (without lids) loaded with fibroblasts. Fig.6 (top) A photograph of 4 microvials made of SU-8 (and therefore transparent) with 2 Au electrodes inside on a glass substrate. One microvial is closed with a lid. (bottom) Microvials loaded with fibroblasts (white dots). The second vial contains 3 cells. The microvials are 100 x 100 x 20µm 3 (w x w x h), the lid is 150 x 150 µm 2, and the electrodes are 20 x 80 µm 2.

As mentioned before, in our first generation of cell clinics we are using impedance measurements to characterise the cells. As a first characterisation of the devices we measured on NaCl solutions with physiologically relevant molarity. Fig. 7 shows the impedance measurements for 0.1-0.3 M NaCl solution. Re(Z) (Ohm) 5 10 4 4 10 4 3 10 4 2 10 4 1 10 4 f-re(z) NaCl concentration 0 1000 10 4 f (Hz) 0.1 M 0.2 M 0.3 M Fig 7 The real part of the impedance measured in a NaCl solution using the electrodes inside a (opened) microvial. Next we loaded the microvials with fibroblasts and measured the impedance. First we measured the impedance on the sucrose medium to get a base line, then added the fibroblasts, and finally lysed the cells by adding triton X100. After cleaning the device, we repeated the measurement series with the same solutions, however instead of adding cells, we added a dummy solution, which was similar to the cell solution except that it did not contain any cells. As can be seen in fig. 8 there is a difference between the impedance of the dummy and cell suspension. This difference we attribute to the presence of the fibroblasts. Impedance measurements on fibroblasts 10 7 Sucrose Sucrose+cells Sucrose+cells+triton X100 Sucrose (dummy) Sucrose+dummy Sucrose+dummy+triton X100 REFERENCES 1 R. H. Baughman, Conducting polymer artificial muscles, Synth. Met., 78 (1996) 339-353 2 T. F. Otero and J. M. Sansinena, Artificial muscles based on conducting polymers, Bioelectrochemistry and Bioenergetics, 38 (1995) 411-414 3 A. Della Santa, D. De Rossi, and A. Mazzoldi, Characterization and modelling of a conducting polymer muscle-like linear actuator, Smart Mater. Struct., 6 (1997) 23-24 4 Q. Pei and O. Inganäs, Electrochemical applications of the bending beam method. 2. Electroshrinking and slow relaxation in polypyrrole, J. Phys. Chem., 97 (1993) 6034-6041 5 E. Smela, O. Inganäs, and I. Lundström, Differential adhesion method for microstructure release: an alternative to the sacrificial layer, Transducers '95, Stockholm, Sweden, 1995, pp. 218-219 6 E. Smela, Microfabrication of PPy microactuators and other conjugated polymer devices, J. Micromech. Microeng., 9 (1999) 1-18 7 E. Smela, M. Kallenbach, and J. Holdenried, Electrochemically driven polypyrrole bilayers for moving and positioning bulk micromachined silicon plates, J. Microelectromech. Syst., 8 (1999) 373-383 8 E. Smela, O. Inganäs, and I. Lundström, Self-opening and closing boxes and other micromachined folding structures, Transducers '95, Stockholm, Sweden, 1995, pp. 350-351 9 F. Pettersson, E. W. H. Jager, and O. Inganäs, Surface Micromachined Polymer Actuators as Valves in PDMS Microfluidic System, IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine & Biology, Lyon, France, October 12-14, 2000, 2000, 10 E. W. H. Jager, O. Inganäs, and I. Lundström, Microrobots for Micrometer-Size Objects in Aqueous Media: Potential Tools for Single Cell Manipulation, Science, 288 (2000) 2335-2338 Re (Z) (Ohm) 10 6 10 5 10 4 100 1000 10 4 f (Hz) Fig 8.The real part of the impedance measured on fibroblasts using the electrodes in (opened) microvials ACKOWLEDGEMENT E.W.H.J. and C.I. are PhD-students enrolled in the graduate school Forum Scientum and wish to thank the Swedish Foundation for Strategic Research (SSF) for its financial support.