Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System



Similar documents
Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Thermo Scientific ExactFinder Software

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Targeted and Nontargeted MS Analysis of Contaminants in Storm Water Retention Ponds

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Thermo Scientific SIEVE Software for Differential Expression Analysis

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

WATERS QUANTITATIVE ANALYSIS solutions

A Determination of Veterinary Drug Residues in Milk Using Polymeric SPE and UHPLC-MS/MS Analysis

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Mass and Resolution Calibration for New Triple-Stage Quadrupole Mass Spectrometers. Rob Grothe Thermo Fisher Scientific, San Jose, CA

LC-MS/MS for Chromatographers

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Pesticide Analysis by Mass Spectrometry

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

How To Control A Record System

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Higher Resolution LC-MS and MS-MS Analysis of Lipid Extracts Using Benchtop Orbitrap-based Mass Spectrometers and LipidSearch Software

Thermo Scientific ConFlo IV Universal Interface

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

AMD Analysis & Technology AG

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

[ Care and Use Manual ]

FT-NIR for Online Analysis in Polyol Production

A Complete Solution for Method Linearity in HPLC and UHPLC

Analysis of Veterinary Drug Residues in China

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

HR/AM Targeted Peptide Quantitation on a Q Exactive MS: A Unique Combination of High Selectivity, Sensitivity and Throughput

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Thermo Scientific Mass Spectrometric Immunoassay (MSIA)

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis

Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare

Supplementary Materials and Methods (Metabolomics analysis)

What is Eluent Generation?

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

How To Test For Contamination In Large Volume Water

Salman Azimi, 1 Nayan S. Mistry, 2 and Michelle Wood 2. Drug Quality Control Laboratory, Supreme Council of Health, Doha, Qatar 2

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Agilent LCMS products and the application strategies in veterinary drug analysis

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

AutoSpec Premier. Are you? Analyzing dioxins and related compounds? Required to satisfy regulatory requirements?

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Transcription:

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System Olaf Scheibner, Maciej Bromirski, Thermo Fisher Scientific, Bremen, Germany Application Note 614 Key Words Q Exactive Focus, Orbitrap, veterinary drugs, HRAM quantitation, HRAM screening, vdia, unknown screening, retrospective data analysis Goal To describe a new method for veterinary drug analysis, showing how the variable data-independent acquisition (vdia) workflow achieves high sensitivity and selectivity, providing a complete high-quality data record of the measured sample. Quantitative analysis of the acquired data in combination with non-targeted and unknown screening is shown. Introduction The analysis of veterinary drugs in animal products is usually a time-consuming process with respect to both sample preparation and mass spectrometric analysis. The quantitative analysis of multiclass veterinary drug residues from animal products including meat, milk, and plasma often requires multiple sample injections in order to achieve optimal conditions for individual classes of compounds. This includes multiple chromatographic methods for different compound classes, as well as separate mass spectrometric methods, each specifically directed to small groups of compounds. The data obtained only contains information on the targeted compounds and is not suitable for any retrospective analysis on additional analytes of interest. Here, a new method utilizing ultrafast chromatography with the Thermo Scientific Q Exactive Focus benchtop Orbitrap mass spectrometer is described. It consists of a short generic chromatographic method and a new mass spectrometric method called variable data-independent acquisition (vdia). The advantages of this approach are short overall analysis time, superior selectivity, and high sensitivity. This robust method provides data with suitable options for additional targeted and non-targeted screening. The vdia approach has been developed and is utilized here for generation of calibration curves and analyses of samples for known and unknown targets. vdia can use multiple MS/MS isolation windows with widths from 50 Da up to 800 Da. Typically, smaller windows are used for lower mass regions to increase dynamic range and therefore sensitivity, while larger windows cover higher mass regions to improve the duty cycle. In a typical Figure 1. Q Exactive Focus benchtop Orbitrap mass spectrometer. acquisition setup, shown here, five MS/MS isolation windows were set to cover the entire mass range of the preceding full scan while maintaining speed of MS/MS analysis for the fast chromatography. Forty-four multi-class veterinary drug residues listed in Table 1, were analyzed in extracts of muscle, kidney, milk, and plasma using a single standardized chromatographic and mass spectrometric method. For absolute quantification, standard samples with known concentrations of all 44 drug residues covering eight calibration points (from 100 pg/ml (ppt) to 500 ng/ml (ppb)) were prepared. For evaluation of the method, spiked matrix samples (muscle and kidney for antibiotics, milk for avermectins and plasma for nitroimidazoles) were analyzed by high-resolution, accurate-mass (HRAM) LC-MS/MS.

2 Table 1. List of components used for analysis with limits of Mass Spectrometry Method quantitation (LOQ). Compound LOQ (ppb) Compound LOQ (ppb) Abamectin* 5.0 Marbofloxacine 5.0 Amoxicillin 1.0 Metronidazole 0.5 Ampicillin 0.5 Metronidazole-OH 0.5 Cefalexin 0.5 Moxidectin 0.5 Cefalonium 0.5 Nafcillin 0.5 Cefaperazone 1.0 Oxacillin 0.1 Cefapirim 0.1 Penicillin G 0.5 Cefquinome 5.0 Penicillin V 0.5 Chlorotetracycline 1.0 Ronidazol 0.5 Ciprofloxacin 0.5 Sarafloxacine 0.5 Cloxacillin 0.1 Sulfadiazine 0.1 Danofloxacin 5.0 Sulfadimethoxin 0.5 Dapsone 0.5 Sulfadimidin/Sulfamethazine 0.1 Difloxacin 0.5 Sulfadoxin 0.5 Dimetridazol 5.0 Sulfamerazin 0.1 Doramectin* 10.0 Sulfamethoxazole 0.5 Doxycyclin 0.5 Sulfamethoxypyridazine 0.1 Enrofloxacin 1.0 Sulfathiazole 0.5 Eprinomectin 5.0 Tetracycline 0.5 Erythromycine 1.0 Thiamphenicol 0.5 Flumequine 1.0 Trimethoprim 0.1 Ipronidazol-OH 0.5 Tylosine 1.0 Experimental Liquid Chromatography Method A generic LC method was used for all samples: A generic full-scan method with wide-isolation variable data-independent acquisition (FS-vDIA) was used for all samples: Instrumentation Q Exactive Focus MS system Full Scan Resolution setting 70,000 (FWHM) at m/z 200 Mass range (m/z) 100 1000 vdia Resolution setting 17,500 (FWHM) at m/z 200 Isolation windows (m/z) 100 205, 195 305, 295 405, 395 505, 495 1000 Spray voltage Sheath gas Aux gas 4.4 kv 30.0 arb. 5.0 arb. Capillary temp. 250 C Heater temp. 300 C RF-lens level 50 HCD collision energy 35 ev Data Processing Data processing was performed using Thermo Scientific TraceFinder software version 3.2. For generation of extracted ion chromatograms, an extraction window of 5 ppm was used. For non-targeted screening, a built-in component and fragment m/z values database was used, consisting of 450 components. Analytes were quantified based on full scan information (quasi molecular ions). Additionally, one to five fragment ions were used for identity confirmation, according to EU regulatory requirements (EC/657/2002), achieving linear calibration curves over the ranges described above. Instrumentation Column Mobile phase A Mobile phase B Gradient Flow rate Total chromatographic cycle Thermo Scientific Dionex UltiMate 3000 Rapid Separation LC (RSLC) Thermo Scientific Accucore C18 aq 100 x 2.1 mm, 2.6 µm particle size (p/n 17326-102130) Fisher Chemical water + 0.1% formic acid Fisher Chemical acetonitrile + 0.1% formic acid 6 min gradient from 5% B to 95% B 300 µl/min 15 min Results and Discussion The vdia approach described bridges the gap between full-scan data-dependent MS 2 (FS-ddMS 2 ) experiments and full range fragmentation scan modes such as all-ion fragmentation (AIF). As Figure 2 shows, this is a combination of a full scan with several wide range isolation MS 2 scans. In this setup, the isolation widths of the MS 2 windows vary between 100 Da and 500 Da and together cover the entire mass range of the preceding full scan. Figure 2. Setup of a typical FS-vDIA experiment. full scan m/z 100 1000 vdia m/z 100 200 vdia m/z 200 300 vdia m/z 300 400 vdia m/z 400 500 vdia m/z 500 1000 FS-ddMS 2 experiments, where MS 2 scans are performed on targets of interest (present on an inclusion list) upon their detection in the full scan, are known to be very selective and sensitive with respect to the fragment ion information obtained. Retrospective FS-ddMS 2 data analysis for additional compounds of interest, however, is limited to full-scan quantitation by accurate mass without confirmation of identity by MS/MS.

Full-range fragmentation experiments like AIF, where fragments from all species present in the full scan are detected in a single MS 2 scan, have the advantage of collecting all possible full scan and MS 2 information for the sample. Thus, they are fully suitable for retrospective data analysis. Dynamic range, selectivity, and achieved detection limits, however, are limited as the number of ions fragmented per species is lower due to the combined nature of the analyses. The vdia approach, where fragments from wide isolation windows covering the entire mass range are detected in multiple MS 2 scans, maintains very high levels of sensitivity and selectivity while keeping a full digital record of the sample. Therefore, it is fully suitable for retrospective data analysis. Table 1 shows the observed limits of detection (LOQs) in a dilution series for full scan quantitation with fragment ion confirmation. LOQ is defined here as the lowest concentration level on which a component could be confirmed with at least one fragment ion. For accurate quantification and confirmation of identity, it is crucial that the fragment ions used for confirmation are clearly resolved in time and mass, so that the confirmation is not affected by elevated background or interfering peaks. Figure 3 shows examples of how the overlay of the extracted ion chromatograms of the confirming fragment ions (right panel) match with the quantifier precursor ion (left panel), acquired in vdia scan mode and automatically processed in TraceFinder software. All confirming ions were free of any interference and co-eluted with the quantifier, providing unambiguous confirmation that is essential, particularly for complex matrices. Since the vdia mode generates full elution profiles for all fragment ions, the chromatographic peaks of the fragments can be integrated and this way the fragment ion ratio can be calculated with high confidence and used for confirmation as well. 3 Figure 3. Selectivity of selected components in matrix; A: ampicillin in pig muscle at 5 ppb; B: sulfadiazin in pig kidney at 5 ppb; C: ronidazol in pig plasma at 1 ppb; D: moxidectin in cow milk at 1 ppb.

4 Figure 4 shows an example of linear dynamic range for selected compounds using the vdia approach. The calibration range spanned from 0.5 ppb to 500 ppb and linearity in all cases was better than R 2 = 0.99. In the cases of abamectin and doramectin, limited stability of the quasi-molecular ions was observed and the sensitivity in the full scan detection was therefore limited. This instability may be due to the use of average parameters for this generic method, suitable for a wide panel of drugs. In these few cases, the vdia approach allows quantitation using several fragment ions of abamectin and doramectin, permitting quantitation and identity confirmation down to much lower levels than the quasi-molecular ions in the full scan. After quantitation curves were established, all components were quantified in the spiked matrices at low levels. Antibiotics were spiked into muscle and kidney matrix at levels of 5 ppb, while abamectins were spiked into milk at a level of 1.0 ppb and nitroimidazoles were spiked into plasma at a level of 1.0 ppb. The TraceFinder processing software provides component detection with high selectivity (by means of the narrow extraction window of 5 ppm) in the full scan with identification according to retention time. In addition to this, TraceFinder software offers three automated options for confirmation of identity. The first uses isotopic information of the precursor detected in the full scan. Figure 5 shows an overlay of the detected spectrum (in red) of ciprofloxacin and the theoretical isotopic distribution (in blue). With a resolution setting of 70,000, even in the complex matrix of muscle extract at a concentration of 5 ppb, the isotopic distribution match is free from interference and gives an unambiguous confirmation. Figure 4. Linearity of selected compounds.

5 Figure 5. Isotope pattern match for the example of ciprofloxacin. The detected spectrum is shown in red, and the theoretical isotopic distribution is shown in blue. Confirmation of identity can be performed using the MS/MS data by detecting known fragment ions. The following results were achieved for a muscle tissue sample at a spike level of 0.5 ppb. Figure 6 shows the result of the fragment ion confirmation in vdia mode. As the vdia spectra are generated using a wide isolation window, fragment ions from multiple precursors can be detected. The highresolution, accurate-mass nature of Orbitrap MS/MS detection allows selective identification of the fragment ions combined with RT profile matching giving confident identification. Figure 6. Fragment match for the example of ciprofloxacin. The experimental spectrum is shown in red, the confirmation masses are shown in blue.

Most routine targeted methods only cover a limited number of analytes. The ability to reanalyze the sample for a suspected drug post-ms analysis becomes very beneficial for saving instrument/lab time and sample. To demonstrate retrospective analysis of the data files, a wide-range screening approach was performed on vdia data files of analytes spiked in muscle tissue samples. A non-targeted screen with a 1500 component built-in database was conducted, providing several strong matches to additional components present in the sample. Figure 7 shows the example of cortisol (hydrocortisone), confirmed by isotopic pattern match, fragment search, and library match. Conclusion The Q Exactive Focus MS in combination with an UltiMate 3000 HPLC was used to create a variable data-independent acquisition method for the detection and quantification of 44 multiclass veterinary drug residues. This novel method proved to have the required LOD sensitivity, and ability to confirm identity using retention time, accurate m/z, isotopic ratio, and fragment ions to exceed the EU regulatory requirements (EC/657/2002). The vdia approach extends confirmation options for non-targeted and unknown screening approaches, while maintaining a high level of sensitivity and selectivity. All data processing was accomplished with the easy-to-use TraceFinder software both for identification and all stages of identity confirmation. vdia accomplishes the goal of being an accurate and sensitive analysis for the detection of non-targeted compounds (i.e. those from the 44 compound panel) and also for the screening of unknown compounds post-analysis. Application Note 614 Figure 7. Non-targeted screening result in TraceFinder software. www.thermoscientific.com 2014 Thermo Fisher Scientific Inc. All rights reserved. ISO is a registered trademark of the International Organization for Standardization (Organisation Internationale De Normalization). All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, (Bremen) GmbH Management System Registered is ISO 9001:2008 Certified. Africa +43 1 333 50 34 0 Australia +61 3 9757 4300 Austria +43 810 282 206 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China 800 810 5118 (free call domestic) 400 650 5118 AN64249-EN 1014S Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland +358 9 3291 0200 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9494 Italy +39 02 950 591 Japan +81 45 453 9100 Korea +82 2 3420 8600 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Norway +46 8 556 468 00 Russia/CIS +43 1 333 50 34 0 Singapore +65 6289 1190 Spain +34 914 845 965 Sweden +46 8 556 468 00 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752