Lipid analysis by multiple "omic" mass spectrometry platforms Where we ve been, where we are, and where we re going

Similar documents
Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

NUVISAN Pharma Services

Introduction to Proteomics 1.0

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Higher Resolution LC-MS and MS-MS Analysis of Lipid Extracts Using Benchtop Orbitrap-based Mass Spectrometers and LipidSearch Software

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

Mass Spectrometry Based Proteomics

MS/MS analysis of Polyphenols

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Overview. Purpose. Methods. Results

Authenticity Assessment of Fruit Juices using LC-MS/MS and Metabolomic Data Processing

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

RapidFire High-throughput MS technology. Enhancing Drug Discovery Turning Mass Specs into Plate Readers

How To Test For Contamination In Large Volume Water

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation. Bringing our targeted metabolomics expertise to your lab.

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

A Streamlined Workflow for Untargeted Metabolomics

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Separation of lipid classes by solid phase extraction

Investigating Biological Variation of Liver Enzymes in Human Hepatocytes

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

LC-MS/MS for Chromatographers

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis

High Resolution LC-MS Data Output and Analysis

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Pesticide Analysis by Mass Spectrometry

La Protéomique : Etat de l art et perspectives

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Aiping Lu. Key Laboratory of System Biology Chinese Academic Society

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

Micromass LCT User s Guide

Supplementary Materials and Methods (Metabolomics analysis)

SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

CHEM 121. Chapter 19, Name: Date:

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Analysis of Phthalate Esters in Children's Toys Using GC-MS

Analyzing Small Molecules by EI and GC-MS. July 2014

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

ProteinPilot Report for ProteinPilot Software

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Guide to achieving reliable quantitative LC-MS measurements

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Instrumentation. Sample pretreatment

AMD Analysis & Technology AG

Factors Influencing LC/MS/MS Moving into Clinical and Research Laboratories

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

LC-MS/MS, the new reference method for mycotoxin analysis

MarkerView Software for Metabolomic and Biomarker Profiling Analysis

Waters Core Chromatography Training (2 Days)

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

Christer Stenby Ejsing

Appendix 5 Overview of requirements in English

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

Introduction to mass spectrometry (MS) based proteomics and metabolomics

aurora M90 Innovation with Integrity A new era in ICP-MS ICP-MS

Transcription:

Lipid analysis by multiple "omic" mass spectrometry platforms Where we ve been, where we are, and where we re going Jeff McDonald Department of Molecular Genetics UT Southwestern Medical Center Dallas, TX LIPID MAPS Glue Grant NIH U54 GM 69338

Lipidome of Human Plasma 588

Lipids in Human Serum pg/ml Wikipedia : Reference ranges for blood tests - by mass.svg mg/ml Total cholesterol ~ 2 mg/ml > 6 orders of magnitude Trace oxysterols < 2 ng/ml Triglycerides ~ 1 mg/ml Phospholipids ~ 2 mg/ml Sphingolipids ~ 0.5 mg/ml mg/ml Cholesterol Cholesteryl ester

General Steps of Lipid Extraction and Purification 1) Solvent extraction (DCM/MeOH) 2) Base hydrolysis 200μL serum + standards KOH, 60 C Organic-soluble (lipids) Insoluble material/ proteins 4) Solid phase extraction Condition With Load sample hexane in hexane Hexane rinse 23:1 CHCl 3 :MeOH 3) Liquid-Liquid Extraction 5) LC-MS Aqueous (MeOH/H 2 O) Organic (lipids) (DCM/MeOH) Non polar lipids Sterols + oxysterols

Analytical Separation and Detection of Lipids HPLC Normal Phase Reverse Phase HELIC Mass Spectrometry Triple Quadrupole (MRM) Neutral Loss Scan Precursor Ion Scan GC DB5-MS 40m 0.18mm i.d. o H 2 carrier gas DB5-MS 30m 0.25 o He Carrier gas Mass Spectrometry Electron Ionization Electron-Capture Negative Ionization o Methane

Measurement of the Plasma Lipidome Neutral Lipids 3 Samples 2 Extractions 1 LC, 3 MS Analysis Sterols/Oxysterol 4 Samples 4 Extractions 2 LC-MS Analysis 2 GC-MS Analysis Prenols/Cardiolipins 3 Samples 1 Extraction 3 LC-MS Analysis Phospholipids 2 Samples 2 Extractions 2 LC-MS Analysis Human Plasma Lipidome Fatty Acids/ Eicosanoids 2 Samples 2 Extractions 1 LC-MS Analysis 1 GC-MS Analysis Sphingolipids 1 Sample 3 Extractions 5 LC-MS Analysis Summary 15 Samples 14 Extractions 14 LC-MS methods 3 GC-MS methods 100 s standards 7 Expert Centers $ Millions/many hours

The Workhorses of Lipid Analysis AB Sciex Triple Quadrupole Mass Spectrometers Agilent GC-MS

Analytical Standards Generated by Avanti Polar Lipids >650 analytical lipid standards 300 new lipid standards Primary, deuterated, odd-chain Purity and stability Packaging, storage, shelf-life In-house analytical expertise

Eicosanoids and Fatty Acids from Cayman Chemical 100+ eicosanoid

MS-Based Methods Developed by LM Cores lipidmaps.org

A Ten-Year Timeline of Lipidomics 2003 2013 LIPID MAPS pioneers and advances speciated, quantitative LC/GC-MS methods for lipids Shotgun Lipidomics introduced and implemented by Hann and Gross Broad-scale, targeted and untargeted LC-MS Omics approaches flourish Suizdak, Fiehn, Sumner, Newgard, Roddy, etc Advanced, infusion-based lipidomic methods introduced

One Sample, Many Choices Sterols Sphingolipids Phospholipids Neutral Lipids Prenols Eicosanoids/Fatty Acids

One Sample, Many Choices Ursus Analyticus Thanks Avanti!

Infusion-Based MS Platform for Lipidomic Analysis 1) Sample Extraction (CH 2 Cl 2 /MeOH) 20uL human plasma Small molecule metabolome Insoluble material/ proteins LEAP Robotic Infusion System AB SCIEX TripleTOF 5600+ MS with SelexION

Workflow for Infusion-Based Global Lipidomics 1 2 3 4 5 B/D Extraction of plasma Infuse into MS Acquire TOF Acquire MS/MS ALL Data Analysis

Workflow for Infusion-Based Global Lipidomics 1 2 3 4 5 B/D Extraction of plasma Infuse into MS Acquire TOF Acquire MS/MS ALL Data Analysis Plasma+Stds Aqueous Organic (lipids)

Workflow for Infusion-Based Global Lipidomics 1 2 3 4 5 B/D Extraction of plasma Infuse into MS Acquire TOF Acquire MS/MS ALL Data Analysis

Workflow for Infusion-Based Global Lipidomics 1 2 3 4 5 B/D Extraction of plasma Infuse into MS Acquire TOF Acquire MS/MS ALL Data Analysis CE TOF Scan 200-1200 Da 30-40K resolution < 2ppm mass accuracy PC Cholesterol PE SM TG DG

Workflow for Infusion-Based Global Lipidomics 1 2 3 4 5 B/D Extraction of plasma Infuse into MS Acquire TOF Acquire MS/MS ALL Data Analysis m/z 666 CE 18:2

Workflow for Infusion-Based Global Lipidomics 1 2 3 4 5 B/D Extraction of plasma Infuse into MS Acquire TOF Acquire MS/MS ALL Data Analysis m/z 369 Product-ion m/z 666 m/z 666 CE 18:2 Neutral Loss 379 = FA 18:2 m/z 666

Workflow for Infusion-Based Global Lipidomics 1 2 3 4 5 B/D Extraction of plasma Infuse into MS Acquire TOF Acquire MS/MS ALL Data Analysis 30 minutes 5 minutes Hour Time Scale

Mining the Dataset Post-Acquisition MS/MS ALL identifies 800+ MS features Lipids that contain a 18:1 fatty acid (NL 281Da) Cholesteryl ester C18:1 Triacylglycerol with FA 18:1 Lipids that contain a PC head group (Prec 184 Da) Lyso Phosphatidylcholines Phosphatidylcholine Lipids that contain a PE head group (NL 141 Da) Lyso Phosphatidylethanolamine Phosphatidylethanolamine

PCA Analysis MS/MS ALL Data Liver Plasma Blank MarkerView (AB Sciex)

Can Infusion-Based Metabolomics be Quantitative? TAG 54:3 LPC 18:0 C 36:2 DAG

The Future of Lipidomics Chromatograhic-based quantitative analysis HPLC resolving power and efficiency MS sensitivity MS acquisition speed Flexible, parallel acquisition Infusion-based analysis Resolution, mass accuracy, linearity Data analysis software Off-line HPLC followed by infusion-based MS Ion-mobility Accessibility to standards Class-specific mixtures (primary and internal)

Acknolwedgements LIPID MAPS community Phil Sanders Eli Lilly Brigitte Simons AB Sciex Jennifer Krone Mark Cafazzo Lyle Burton AB-Sciex Academic Partnership Program