Agilent 35670A - Dynamic Signal Analyzer



Similar documents
Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Power meter. Caratterizzazione di amplificatori a RF. Amplificatori a RF. Incertezza Corso di Laboratorio di misure ad alta frequenza

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers

MATRIX TECHNICAL NOTES

Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Keysight Technologies N9320B RF Spectrum Analyzer

Keysight N9320B RF Spectrum Analyzer

Keysight N9000A CXA Signal Analyzer

F = S i /N i S o /N o

A Guide to Calibrating Your Spectrum Analyzer

Propagation Channel Emulator ECP_V3

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

khz to 2.7 GHz Spectrum Analyzer

HP 70950B OPTICAL SPECTRUM ANALYZER

Impedance 50 (75 connectors via adapters)

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Phase Noise Measurement Methods and Techniques

Technology Trend in Spectrum Analyzer

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Measurement of Adjacent Channel Leakage Power on 3GPP W-CDMA Signals with the FSP

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

GOOD WILL Instrument Co., Ltd. All rights reserved.

Conquering Noise for Accurate RF and Microwave Signal Measurements. Presented by: Ernie Jackson

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

HF Receiver Testing. Issues & Advances. (also presented at APDXC 2014, Osaka, Japan, November 2014)

Spectrum Analyzer Basics www. agilent.com/find/backtobasics

Keysight Technologies ESA-E Series Spectrum Analyzer

Spectrum Analyzers. R9211Series. R9211A/9211B/9211C/9211E FFT Analyzer Series. Choice of 4 Types To Fit the Application

Optimizing IP3 and ACPR Measurements

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Agilent E5100A Network Analyzer

Fast and Accurate Test of Mobile Phone Boards

GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy

R&S FSW signal and spectrum analyzer: best in class now up to 50 GHz

RF Network Analyzer Basics

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

Handheld Spectrum Analyzer

Agilent Spectrum Analysis Basics Application Note 150

Multi-Carrier GSM with State of the Art ADC technology

Network analyzer and spectrum analyzer two in one

Making OSNR Measurements In a Modulated DWDM Signal Environment

HD Radio FM Transmission System Specifications Rev. F August 24, 2011

Spectrum Analysis Basics. Application Note 150

AIM & THURLBY THANDAR INSTRUMENTS

Agilent Spectrum Analysis Basics. Application Note 150

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems

FUNDAMENTALS OF MODERN SPECTRAL ANALYSIS. Matthew T. Hunter, Ph.D.

AM/FM/ϕM Measurement Demodulator FS-K7

Understand the effects of clock jitter and phase noise on sampled systems A s higher resolution data converters that can

Measurement Guide and Programming Examples

Reading: HH Sections , (pgs , )

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

HANDBOOK. Measuring System DESIGN EDITORS PETER H. SYDENHAM RICHARD THORN ARTICLE OFFPRINT

Spectrum Analyzers And Network Analyzers. The Whats, Whys and Hows...

How To Use A High Definition Oscilloscope

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

Handheld Spectrum Analyzers, 3.3 GHz & 8.5 GHz Models 2650A, 2652A, 2658A

Spectrum Analyzer for Anritsu RF and Microwave Handheld Instruments

EMI Debug using a Rohde&Schwarz Oscilloscope

Oscilloscope Bandwidth Requirements for Emerging Serial Data Interfaces

Welcome. Rulon VanDyke RF System Architect, Agilent Technologies. David Leiss Senior RF Simulation Consultant, Agilent Technologies

Using Spectrum Analyzers For Signal Monitoring

Making Spectrum Measurements with Rohde & Schwarz Network Analyzers

Agilent Spectrum and Signal Analyzer Measurements and Noise

Keysight Technologies M9393A PXIe Performance Vector Signal Analyzer. Data Sheet

PCM Encoding and Decoding:


Measurement, analysis, and monitoring of RF signals

Agilent Vector Signal Analysis Basics. Application Note

Antenna Measurements with the Network Analyzer. Presented by Ernie Jackson RF/uW Applications Engineer Agilent Technologies

One Port Network Analyzer

1 khz offset 107 dbc/hz (Opt. 062) 10 khz offset 113 dbc/hz (Opt. 062) 115 dbc/hz (Standard) 133 dbc/hz (Opt. 062) 1 MHz offset

FFT Spectrum Analyzers

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

RF Level Measurement Uncertainties with the Measuring Receiver R&S FSMR

R&S ZVA Vector Network Analyzer Specifications

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

ETSI EN V1.2.2 ( )

Agilent Spectrum Analyzer Measurements and Noise

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

Agilent E6832A W-CDMA Calibration Application

Field Calibration Software

Spectrum Analyzer. H500 / SA2500 Datasheet. Features & Benefits. Applications. Classify. Locate. Scan

TCB Workshop. Unlicensed National Information Infrastructure Devices (U-NII)/Dynamic Frequency Selection (DFS)

SR2000 FREQUENCY MONITOR

Network Analyzer Operation

Power Amplifier Gain Compression Measurements

HP 8590 E-Series Portable Spectrum Analyzers Technical Specifications

Application Note Noise Frequently Asked Questions

Dithering in Analog-to-digital Conversion

Transcription:

Agilent 35670A - Dynamic Signal Analyzer Two- or Four-channel high-performance FFTbased spectrum /network analyzer 122 µhz to 102.4 khz 16-bit ADC United States: Price for 35670A from USD 18,300.00 35670A - Standard Features Instrument Modes FFT Analysis Histogram/Time Correlation Analysis Time Capture Measurement Frequency Domain? Frequency Response? Power Spectrum? Linear Spectrum? Coherence? Cross Spectrum? Power Spectral Density Time Domain (oscilloscope mode)? Time Waveform? Autocorrelation? Cross-Correlation? Orbit Diagram Amplitude Domain? Histogram, PDF, CDF Trace Coordinates Linear Magnitude Unwrapped Phase Log Magnitude Real Part db Magnitude Imaginary Part Group Delay Nyquist Diagram Phase, Polar 1

35670A - Frequency specifications (I) f c = 262144 Hz f h = 102400 Hz f h = 0.39 f c N = 4096 = 2 12 for 1600 lines display multiplexed channels f hmax /f hmin = 2 19 20 frequency spans f = 122 µhz for f hmin = 195.3 mhz 35670A - Frequency specifications (II) T FFT < N/RTB = 160 ms Accuracy (quartz clock) << f/fc = 1/N = 0.024% 2

35670A - Amplitude Specifications 35670A - Dynamic Range 3

35670A - Input noise 0.125% = 1/800; N = 2048 35670A - Time Domain 3.815 µs = 1/262 KHz 4

35670A - Digital Interfaces 35670A - Digital Interfaces 5

Segnale sinusoidale periodico nel tempo di acquisizione Segnale sinusoidale non periodico nel tempo di acquisizione la potenza della fondamentale viene sparpagliata in tutto lo spettro: Leakage le righe vicine alla fondamentale non si vedono 6

Windowing No window With Hanning window, reduced leakage Finestra di Hanning Si utilizza per i segnali periodici e il rumore Non per i transitori Nessuna finestra con finestra di Hanning 7

Finestra Uniforme (o Rettangolare) Si usa per tutti i segnali di durata finita selfwindowed? Transitori? Impulsi? Treni di impulsi? etc. Finestra Flat-Top Si usa quando si vuol misurare in modo accurato l ampiezza dello spettro. Vediamo la finestra nel dominio delle frequenze come una serie di filtri passanda.? Finestra di Hanning: attenuazione di 1.5 db (16%) per frequenze a metà tra due righe.? Finestra Flat-Top: attenuazione di 0.1 db (1%) per frequenze a metà tra due righe La finestra flat-top consente una minore accuratezza in frequenza Finestra di Hanning Finestra Flat-Top f f 8

Altre Finestre Response window? transitori più lunghi del tempo di acquisizione Force window Agilent PSA series - E4440A E4440A PSA Series High- Performance Spectrum Analyzer, 3 Hz - 26 GHz Key Features and Specifications SPEED: The Industry's fastest lowlevel spur search ACCURACY: The Industry's most accurate spectrum analyzer DYNAMIC RANGE: The Industry's most useable dynamic range FLEXIBILITY: The Industry's finest resolution bandwidth settings The Industry's first phase noise optimization The Industry's most complete detector selection Product Price United States: Price for E4440A from USD 48,000.00 9

Agilent PSA series block diagram 30 MSPS - 14 bit DAC 160 steps of RBW 2dB step attenuator 0-70 db 30 db gain preamplifier E444xA - Frequency specifications (I) 10

E444xA - Frequency specifications (II) Frequency span (FFT and swept mode) 0 Hz (zero span), 0 Hz to 26.5 GHz Resolution 2 Hz Accuracy ± 0.2% of span + span/600 Frequency sweep time Range 1ms to 2000 Zero span range 1µs to 6000s Resolution bandwidth 1 Hz to 3 MHz (10% steps), 4, 5, 6, 8 MHz Accuracy 1 Hz to 1.5 MHz (± 2.0%) typical 1.6 MHz to 3 MHz (± 7.0%) typical 4 MHz to 8 MHz (± 15%) typical Selectivity (60dB/3dB) 4.1:1 (nominal) Frequency sweep time >> Frequency span / (resolution bandwidth) 2 E444xA - Amplitude specifications Amplitude range [Measurement range: displayed average noise level (DANL) to maximum safe input level] Preamp (Option D5) DANL to +25 dbm Input attenuator range: 0 to 70 db n 2 db steps (to 26.5 GHz) Displayed average noise level (DANL) (input-terminated, 0 db attenuation, sample detector, normalized to 1 Hz RBW, 20 to 30 C) Pream off Pream on (500 khz to 3 GHz) 10 khz to 100 khz 130 dbm 100 khz to 1 MHz 135 dbm 1 MHz to 10 MHz 145 dbm 163 dbm 10 MHz to 1.2 GHz 155 dbm 169 dbm 1.2 GHz to 2.5 GHz 154 dbm 168 dbm 2.5 GHz to 3 GHz 153 dbm 168 dbm 3 GHz to 6.6 GHz 152 dbm 6.6 GHz to 3.2 GHz 150 dbm 3.2 GHz to 20 GHz 147 dbm 20 GHz to 26.5 GHz 143 dbm 11

Specifications (continued) ESA- L Series E4408B E4408B ESA-L Series Spectrum Analyzers, 9 khz to 26.5 GHz The Agilent ESA-L series of general-purpose, portable spectrum analyzer provides basic spectrum analysis, with the speed and accuracy you need. These affordable, fully synthesized analyzers are available in three frequency ranges: 1.5 GHz, 3.0 GHz and 26.5 GHz. Key Features and Specifications Four-millisecond sweep time ±1.1 db overall amplitude accuracy Large, high-resolution VGA display Rugged, portable, weather-resistant package Five-minute warm up Built-in help button Product Price United States: Price for E4408B from USD 23,850.00 12

EE44xxB - Frequency specifications Frequency range E4411B 1 MHz to 1.5 GHz E4403B 9 khz to 3.0 GHz E4408B 9 khz to 26.5 GHz Frequency reference? Aging rate ± 2x10-6 /year, ±1.0x10-7 /day, characteristic? Settability ±5x10-7? Temperature stability ±5x10-6 Frequency span? E4411B 100 Hz to 1.5 GHz? E4403B 100 Hz to 3.0 GHz? E4408B 100 Hz to 26.5 GHz Resolution 2 Hz x N 2 Accuracy ±1% of span Frequency Specifications Sweep time? Range 4 ms to 4000 sec.? Accuracy ±1% Sweep (trace) points 401 Resolution bandwidth? Range ( 3 db bandwidth) 1 khz to 3 MHz in 1-3-10 sequence and 5 MHz ( 6dB bandwidth) 9 khz and 120 khz Accuracy? 1 khz to 3 MHz RBW ±15%? 5 MHz RBW ±30% Selectivity 0 db/3 db bandwidth ratio <15:1, characteristic sweep time >> frequency range /(resolution bandwidth) 2 13

Amplitude specifications Absolute amplitude accuracy Overall amplitude accuracy ±(0.6 db +absolute frequency response(0.5 db)) Input attenuator range 0 to 65 db, in 5 db steps 1-dB gain compression (total power at input mixer) 50 MHz to 6.7 GHz 0 dbm 6.7 GHz to 13.2 GHz 3 dbm 13.2 GHz to 26.5 GHz 5 dbm Displayed average noise level? 10 MHz to 1.0 GHz 116 dbm? 1.0 GHz to 2.0 GHz 115 dbm? 2.0 GHz to 6.0 GHz -112 dbm? 6.0 GHz to 12.0 GHz 110 dbm? 12.0 GHz to 22.0 GHz 107 dbm? 22.0 GHz to 26.5 GHz 101 dbm 14