Flue Gas Analysis as a Diagnostic Tool for Fired Process Heater Furnaces

Similar documents
Energy Efficient Operations and Maintenance Strategies for Boilers

OXYGEN AND OPACITY STACK EMISSION MONITORING SYSTEMS TO OPTIMIZE COMBUSTION EFFICIENCY AND MEET EPA REQUIREMENTS

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Improving Steam Methane Reformer Performance with the ZoloSCAN-SMR

Continuous flow direct water heating for potable hot water

Balancing chemical reaction equations (stoichiometry)

Advanced Solutions for Gas Monitoring

COMBUSTION. By: Michael Biarnes. In collaboration with: Bill Freed and Jason Esteves. E Instruments International LLC -

FIRED HEATER OPTIMIZATION

SULFUR RECOVERY UNIT. Thermal Oxidizer

INDEX GENERAL

Diagnostics for Mobile Homes: HVAC

Natural Gas Conversions of Existing Coal-Fired Boilers

Boiler Tune-up Guide

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Fossil fuel heating equipment

Description of Thermal Oxidizers

Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance

Certificate: _01 / 29 April 2014

Combustion Analysis Basics

Analytical Service Certification Program

Certificate: / 20 August 2013

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

PART 11: START-UP PROCEDURES FOR THE INSTALLER

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

Texas Commission on Environmental Quality Page 1 Chapter Control of Air Pollution from Nitrogen Compounds

Beware of Exaggerated Claims and Uncertified Manufacturers Ratings Regarding Commercial Boiler Efficiency

Hybrid Power Generations Systems, LLC

State of the Art (SOTA) Manual for Boilers and Process Heaters

Condensing Boiler Efficiency

Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN.

DIRECT-FIRED HEATERS: OPERATOR TRAINING. Intensive 2-Day Training Course for Facility Operators

HC900 for Boiler Control Applications

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

ATMOSPHERIC EMISSIONS FROM GAS FIRED HOME HEATING APPLIANCES

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology

Limitations of the Combustion Efficiency Test. What Efficiency Testing Means in Boilers. RATINGS New Facilities Retrofit O&M

Copyright is owned by the Author of the thesis. Permission is given for a copy to be downloaded by an individual for the purpose of research and

PMI-IF-H High Efficiency Gas Heat Units

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

Thermal Mass Flow Meters

Boiler NOx Emissions and Energy Efficiency

1.0 What Are the Purpose and Applicability of Performance Specification 11?

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

Low Emission - Low Maintenance Burner Design

Keywords: PEMS, CEMS, turbine

Fundamentals of Mass Flow Control

Assignment 8: Comparison of gasification, pyrolysis and combustion

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Gas and flame detection Stack gas and dust analysis

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

STANDARD CLEANING AND CALIBRATION PROCEDURE FOR TGA-50(H) AND TGA-51(H)

Technical Solutions for Emissions Reduction

Building Energy Systems. - HVAC: Heating, Distribution -

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

THE DETECTION OF GREENHOUSE GASES

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

BOILER TUNE-UP GUIDE FOR NATURAL GAS AND LIGHT FUEL OIL OPERATION GREG HARRELL, PH.D., P.E.

Thermo Scientific Arke SO 3 System. increased sensitivity. greater value

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Application Note 12: TrendView Recorders Continuous Emissions Monitoring

The soot and scale problems

ALUMINUM. BestPractices Assessment Case Study. Alcoa North American Extrusions Implements Energy Use Assessments at Multiple Facilities.

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Optimizing DRI production using natural gas

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs

HC900 Boiler Control. Background. Solution. Application Brief Industry: Manufacturing

Combustion Pulsation and Noise by Dan Banks, P.E., Banks Engineering Inc.

Mass Flow Meter Product Guide

OROT RABIN POWER STATION UNITS x 350 MW

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

Latest Low-NOx Combustion Technology for Pulverized-coal-fired Boilers

ANSI/BPI-1200-S-2015:

Continuous Emissions Monitoring - Program 77

Online Infrared Flue Gas Analyzer Gasboard 3000

World s Best Oil in Water Analyzers

BEST PRACTICE GUIDE. Energy Efficiency: Steam, Hot Water and Process Heating Systems

The Ambient Air Monitoring System

Application Requirement

HVAC Processes. Lecture 7

Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

An Experimental Study on Industrial Boiler Burners Applied Low NOx Combustion Technologies

Laser Diode Gas Sensors

2nd IEA Oxyfuel Combustion Conference

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

This article provides a basic primer on an

Assessing the Changes Required by the Industrial Boiler MACT Regulations

Energy Saving Solutions. Bob Montgomery Technical Solutions Specialist Waterloo Manufacturing

Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control

Estimated emissions and CO2 savings deriving from adoption of in-place recycling techniques for road pavements

Transcription:

Application Data Sheet Refining Flue Gas Analysis as a Diagnostic Tool for Fired Process Heater Furnaces Overview, and Traditional Application Combustion flue gas analysis has been used by process heater operators for decades as a method of optimizing fuel/air ratio. By measuring the amount of excess oxygen and/or CO in the flue gases resulting from combustion, furnace operators can operate at optimum efficiency and lowest NO x, and also generate the least amount of greenhouse gas.the theoretical ideal, or the stoichiometric point is where all fuel is reacted with available oxygen in the combustion air and no fuel or is left over. Figure 2 - CFD Depiction of the Turbulent Mixing of Fuel and Air Through a Burner Figure 1 - Key Flue Gas Measurements Relating to Ideal Combustion Stoichiometry CO C Air-to-Fuel Mixture Rich (Deficient Air) % of Stack Gases 12 11 10 9 8 7 6 5 4 3 2 1 Stoichiometric Point Figure 3 - DCS Trend Depicting the Relationship of and CO Indications at CO Breakthrough Point 4 2 The "combustion process" is the burner. CO Operating furnaces never attain this ideal, however, and the best operating point usually will result in 1 3 % excess air and 0 200 PPM of CO. This optimum operating point is different for every furnace and also varies for differing loads, or firing rates. A higher firing rate induces greater turbulence through the burner(s), providing better mixing of fuel and air, and enabling operation with a lower excess before unburned fuel (represented by CO) appears, or breaks through. For most furnaces, this point of CO breakthrough is fairly repeatable, and reduces the need for a separate CO or combustibles sensor. 0 10 min

This ideal operating point will vary with firing rate, so a function generator is usually developed from test data using a portable analyzer to assign the ideal control point based upon an index of firing rate, such as fuel flow or charge flow. Figure 4 - A Typical Functio Generator Depicting the Optimum Flue Gas Level at Different Steam Flows (Firing Rates) New EPA Regulations The traditional goal of achieving best combustion efficiency is often being modified to accommodate two other goals: 1. Minimizing the thermal NO x produced through the burner. levels and flame temperatures are key indicators to the production of NO x. % Excess 16 14 12 10 8 6 4 2 0 0 10 20 30 40 50 60 70 80 90 100 % Steam Flow Original Setpoint New Setpoint Actual Data Figure 5 - NO x as a function of flue gas excess Relationship of NO x production NO X (mg / m 3 ) 1800 1600 1400 1200 1000 800 600 400 NO X as a Function of Air / Fuel Ratio This curve should be reestablished from time to time as burners wear, and other furnace conditions change over time. If the furnace utilizes forced draft fans, operators may dynamically control oxygen to the optimal level via the distributed control system, or they may make manual adjustments to establish the optimum and/or CO levels. Natural draft furnaces may not offer control of the inlet air to the burners, so the the outlet stack damper can be adjusted to change the draft, and the air flow coming through the burners. The stack outlet damper also controls furnace pressure, which becomes a constraint. Manual adjustments to the inlet vanes at natural draft burners are sometimes made by operators. Direct control of CO is sometimes done, typically with a line-ofsight infra-red analyzer, or more recently the tunable diode laser analyzers. Since target CO levels are usually in the low PPM range, making fan or damper adjustments small enough to control at these low levels can be challenging. 200 0 0.50 0.70 0.90 1.10 1.30 1.50 1.70 Low NO x burners use internal flue gas recirculation, which results in less heat intensity in the burner, producing less thermal NO x Lower greenhouse gas production - carbon dioxide (C ) is a natural byproduct of combustion. but the US EPA has been given authority to regulate its production as with more toxic flue gas emissions like S and NO x. Indeed, the refining industry has been singled out for enforcement under the EPA s National Petroleum Refinery Initiative. The Greenhouse Gas Mandatory Reporting Rule (GHG MRR) requires most refinery sources to measure either the carbon content of the fuel under Tier III rules, or to measure the actual C exiting the stack as part of a CEMS system. Operating a furnace or boiler at its optimum efficiency minimizes the production of C. This is counter-intuitive, since, as Figure 1 indicates, C production actually peaks out around the stoichiometric fuel-air ratio. While one might be tempted to operate a bit lean of stoichiometry (with extra air), this extra air would have a quenching effect on the flame, and less energy would be produced. The furnace would have to run longer to make up for the losses, and more C would be produced in the end. Page 2

Technologies for Measuring Combustion Flue Gases Oxygen The most ubiquitous technology for measuring combustion flue gases has been the zirconium oxide fuel cell oxygen analyzer. This analyzer technology was first used in the power generation industry in the early 1970s, but the technology has transferred to use for any combustion process. Much has been written about the details of how the Nernstian sensor operates, and this paper will not review this information. The in situ Z r probe results in a point measurement within the flue gas duct, however, and several probes of different lengths may be required in order to get a representative average across large flue gas ducts. Carbon Monoxide CO is usually the first combustible gas component to appear when combustion fuel/air ratios start becoming too rich. Desired CO levels in combustion flue gases are typically less than 200 PPM, and several technologies are used to measure carbon monoxide. - Extractive systems where the flue gases are removed from the duct and cleaned, and moisture removed before being placed into a rack-mounted analyzer. Infra-red spectroscopy is usually used in these systems, and is well suited to measuring at these low levels. Repeatability of better than +/- 5 PPM are possible, with low interference from H 2 O and C. - Close-coupled extractive systems which filter out particulate, but do not remove moisture from the flue gases. A Z r sensor is typically used, along with a calorimetric combustibles sensor (sometimes termed CO equivalent or COe). Figure 6 - Z r sensing cell mounted to the end of a probe (.5 6 M long) The Z r sensing technology is ideally suited for measuring combustion flue gases for the following reasons: - The sensing cell generates its own millivoit signal, similar to the a thermocouple works. - This raw millivoit signal is inverse and logarithmic, i.e. increasing greatly with the low percent readings typically found in combustion processes. Accuracy actually improves as levels decrease. - The sensor is typically heated to 700 C 750 C, making it suitable for operation in hot cumbustion flue gases. - The sensor is robust, and can withstand the sulfur components found in many waste fuel gases. - No sampling system is required. The sensor can be placed directly into the flue gas stream on the end of the probe that can be form 18 inches to 12 feet long. Since the flue gases enter the sensor via passive diffusion, even applications with heavy particulate content are possible with a low rate of filter pluggage. - Sensors can be calibrated on-line and in-place. Automated calibration is also available. - Hazardous area approvals are available to Class I Zone 1 Gr. B, C, D, and also the European ATEX equivalent. Figure 7 - Close-coupled Analyzer for Measuring Oxygen and or Combustibles. Sample Intake Tube Sample Exhaust Tube Removable Tube Filter Blowback Air Connection Red arrows indicate flue gas flow Blue arrows indicate blowbackn air flow Flue gas flows by cell and into tubing to be taken to the Comb cell Page 3

The combustibles sensor burns any combustible gases, which results in a temperature increase in a sensing RTD or other element. Sensitivity and repeatability are not as good as with an infra-r ed analyzer, but is suitable as a safety indication. - Across duct line-of-sight configurations whereby an infra-red source is mounted on one side of the duct, and a receiver or detector is mounted to the opposite side. Figure 8 - Typical Across-Duct Infra-Red Measuring Arrangement Transmitter Receiver Tunable diode lasers (TDL) have recently come onto the scene, again using IR spectroscopy, and again usually using an averaging line-ofsight arrangement. This technology is also capable of measuring in the overtone range, and NO x. Again, much has been written about the underlying technology, so we will not cover this in this paper. As with the traditional IR systems, a TDL in an across stack line-ofsight arrangement will inherently average across the entire furnace volume, requiring fewer instruments to cover a large duct, but also providing less granularity of the flue gases within the duct. Lineof-sight analyzers cannot be challenged with known calibration gases, and, according to the US EPA, are not acceptable for use as continuous emissions monitors (CEMS). New Applications in Large Furnaces Historically, combustion analyzers have been placed above the convective zone, or into the smokestack. Large furnaces may have several combustion zones, however, and there has been a trend to place the analyzers into the top of each radiant zone. Power Supply Signal Processor - This line-of-sight method results in an inherent average across the entire duct, so multiple instruments are less likely required to cover a large duct. Conversely, one does not get the granularity of information that an array of point measurement probes provides. - Dual-pass probe - A modification to the across stack line-of sight method, this arrangement is a dual pass probe where the infra red energy is sent out to a mirror at the end of a hollow pipe, and then reflected back to the source end for analysis. The flue gases are permitted to fill the probe tube through holes or filters. Any optical technology presents application challenges that need to be considered: - An extractive system involves transporting and filtering the sample flue gases removing the moisture, and returning the sample to the process or to a safe vent. This adds considerable cost to the system and will require significant maintenance attention if there is a particulate in the flue gases. - An across duct line-of-sight system cannot be placed where temperatures are much above 600 C, nor endure high levels of particulate. Thermal growth of the ductwork abd vibration can negatively impact the alignment of the source and receiver sides. Also, this type of arrangement cannot undergo a true calibration, since this would involve filling the entire duct with calibration gases. - A dual-pass probe system has to be contend with soiling of the reflecting mirror at the end of the probe. Figure 9 - Four analyzers placed zone by zone, at the top of the radiant sections. Flue Gas Stratification Tells A Story Forward-thinking operators will use these varying indications as a diagnostic tool to look for problems in the furnace, such as: - Fuel Gas BTU variation - will be indicated by both and CO variation. - Fouled burners - depending on the consistency and quality of waste fuel gas burned in a furnace, a burner will change over time. Low NO x burners can be particularly sensitive. - Flame carryover - combustion sometimes progresses well into and beyond the convective zone, and is indicated by lower readings, higher CO readings, or both, along with rising outlet temperatures. - Tube leaks - an unbalanced furnace can cause flame impingement and associated tube wastage. A tube leak will typically show up as a lower reading, and spiking CO readings. Page 4

- Furnace casing leaks - will result in elevated readings, since 21 % of the air leaking in is oxygen. - Sticking dampers- stack outlet dampers are sometimes poorly maintained, and sluggish control of, COe, and furnace draft are indicative of problems. New Sensor Developments Continued research into the Z r fuel cell technology is yielding new capabilities. It was previously mentioned that the millivolt output of these sensing cells is inverse and logarithmic, so lower levels of oxygen results in higher levels of signal. A sensing cell has been developed that will continue outputting increasing voltage as flue gas levels pass through zero and into reducing conditions. This has become a tool for processes that periodically pass into reducing conditions, providing an indication of the level of oxygen deficiency during these events, and informing the operator if recovery measures being taken are being effective. Figure 12 - Oxygen Analyzer Ranged to Indicate Oxygen Deficiency During Reducing Conditions in an FCCU Regenerator. Courtesy of Chevron. Low excursions are often followed 1 year of readings inside FCCU Regenerator Figure 10 - Tube leak from flame impingement, and resulting heat damage. Ideal Probe Placement Oxygen probes are provided in a wide range of lengths, from 18'' to 12' 0, but plant engineers often wonder if a given placement is the optimum. A variable insertion capability has been developed that permits the instrument engineer to find the best possible mounting location for a given probe. Low Summary Combustion flue gas analysis has long been a key tool for optimizing the combustion of refinery boilers and process heater furnaces. Automatic control of and/or CO is common in the power industry, but much less so in fired process heaters. Natural draft furnaces with poor automation of air control is a key reason for this lack of automation. Figure 11 - Variable insertion probes in horizontal and vertical orientations. Innovative customers have exploited reliable analyzers to achieve new goals, such as NO x reduction, and minimizing the production of greenhouse gases. The measurement of Oxygen has been dominated by the in situ Z r probe, which provides a point measurement, but requiring an array of probes across a flue gas duct in order to arrive at a good average reading. Good granularity is afforded by this array, opening a furnace diagnostic capability to balance the combustion in large furnaces, detect burner problems, identify furnace casing leaks, charge tube leaks, and combustion carry over into the convective zone. Page 5

New installation locations are being attempted, with hotter radiant zones gaining favor. Variable insertion probe mounts afford the ability to find the ideal location within a flue gas duct. Continued research into fuel cell sensing technology has yielded a new sensor that measures oxygen deficiency during upset reducing conditions. The addition of a combustibles sensor is becoming more common in close-coupled extractive systems, yielding a CO equivalent measurement that is not as sensitive as an infra-red measurement, but is suitable for use as a safety indication of fuel/air ratio. The measurement of CO is most commonly made with infra red technology in either an extractive configuration, across duct line-ofsight configuration, or dual pass probe configuration. CO is typically found in low PPM levels, so automatic control on CO is more difficult. New tunable diode laser technology has the capability of measuring, CO and NO x. As with the traditional Infra-red technology, across-duct line-of-sight configurations inherently average across a flue gas duct, minimizing the need for multiple instruments, but affording poor granularity within a given optical path. It is not possible to calibrate a line-of-sight instrument inside the process with calibration gas. References: 1) US EPA draft presentation Dec. 2009 - National Petroleum Refining Initiative. 2) Z r measuring technology: P. Shuk: Process Zirconia Oxygen Analyzer: State of Art, Technisches Messen, N 1, 19-23 (2010). 3) Infra-red spectroscopy: Michael B. Esler, David W. T. Griffith, Stephen R. Wilson, and L. Paul Steele: Precision Trace Gas Analysis by FT-IR Spectroscopy. Simultaneous Analysis of C, CH 4, N 2 O, and CO in Air, Anal. Chem., 72 (1), pp 206 215 (2000). 4) Tunable diode laser: Maximilian Lackner, (Ed): Gas sensing in industry by tunable diode laser spectroscopy (TDLS). Review on state-ofthe-art metrology for demanding species concentration, temperature and pressure measurement tasks, Verlag ProcessEng Engineering, 115 pp (2009). Maximum benefit from the use of flue gas analyzers results from close collaboration between instrument suppliers, plant instrument engineers who implement them, and operations personnel that use them on a daily basis. Page 6

Notes Page 7

www.rosemountanalytical.com www.analyticexpert.com www.youtube.com/user/rosemountanalytical www.twitter.com/raihome www.facebook.com/emersonrosemountanalytical 2013 Emerson Process Management. All rights reserved. Emerson Process Management Rosemount Analytical Inc. Gas Analyzer Service Center 6565P Davis Industrial Parkway Solon, OH 44139 USA T +1 440 914 1261 Toll Free in US and Canada 800 433 6076 F +1 440 914 1262 US Response Center 800 654 7768 gas.csc@emerson.com The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount Analytical is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. CMB_ADS_O2Analyzer_Refining_Flue_Gas_Analysis