ACS-30-EU-EMDR-10-MOD



Similar documents
Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

DALI RC BASIC SO. Control unit Operating instructions

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

CO2 Alarm. Operation. Application

Speed Control Relays SX2

Product overview mm. 100 mm

HERZ-Thermal Actuators

Fire Alarm Control Panel. Family. Operating Manual

Color Mark Sensor with Red or Green LED E3S-VS

Electronic Pressure Switch EDS 300

Operating Instructions. Room temperature controller

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Product and functional description

WD-AMX Water Detection Controllers

Water Leak Detection System

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Heating, air-conditioning, cooling

FIRERAY 2000 Installation Guide

Three-phase monitoring relay CM-PFE

HM-W536 Install Guide

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

NGC-30-CR -CRM -CRMS -CTM -CVM

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Shunt lock function 3066

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Safety technique. Emergency stop module BO 5988 safemaster

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Digital input modules

Drayton Digistat +2RF/+3RF

How To Use A Power Supply Unit (Upu)

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

W150: Miniature photoelectric switch series with completely integrated electronics

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Floodlight Range Installation Guide

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

AUTODIALLER / QUICKDIALLER - SA132

Problem / Solution. The problem:

Current Monitoring Kit QUICK START GUIDE

Infrarot-Bewegungsmelder IP44

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Current Monitoring Kit

Operating instructions IV / 2007

How To Read A Pipe From A Sensor

COLOR VIDEO DOOR PHONE CDV-71BE/D

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Electronic Control Devices The European Product Catalogue 2007

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

SECURITY SYSTEM ADP-CAN

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Danfoss Link Mobile Phone Butler

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

T5000 T000 LCD Digital Fan Coil Thermostat

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone.


7 Lighting Technology

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Manual for Fire Suppression & Methane Detection System

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

basicdim DGC Compact control module

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Digital Pressure Measuring Instrument MDR480

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Heating Controller. Building Technologies HVAC Products

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Cross-beam scanning system to detect slim objects. 100 mm in

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

HCE80/HCC80/HCE80R/HCC80R

MOUNTING AND OPERATING INSTRUCTIONS

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Advantium 2 Plus Alarm

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

GAE953 Electrical Alarm Unit 19" with Indicator

RM4TG20 three-phase network control relay RM4-T - range V

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Air damper actuators

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

15 Series - Electronic step relay and dimmer. Features SERIE

PCS0100en Persy Control Services B.V. Netherlands

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Transcription:

Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature range Mounting Enclosure Dimensions Enclosure type Connections Description The Raychem ACS-30-EU-EMDR-10-MOD Module for the ACS-30 system provides smart sensor input for roof & gutter de-icing applications. The module provides temperature & moisture sensing input. The module can be positioned near to the heated area and is connected to the PCM module via a 3-wire cable. The module is provided with a 4m external temperature and moisture sensor to be positioned at the heated surface. The sensor cold lead cable can be extended to a maximum length of 100 m (using 3 x 1.5 mm2 cable.) The output from the ACS-30-EU-EMDR-10-MOD module enables the switching of the heating circuits within the power & control module (PCM). CE Marked. IP55 (enclosure with control device) 0 to +35 C (enclosure with control device) Wall mounting 332 mm x 262 mm x 132 mm Polystyrene box and polypropylene cover 4 Polyamide Cable Glands (IP68 rated) with stopping plugs Control Device Device name EMDR-10 Supply voltage 230 Vac, +/ 10%, 50Hz Power Consumption 4VA max. Measuring accuracy +/ 1.5K Operating differential +/ 0.5K Moisture Sensor (output) I max 1A/230 VAC, SPST potential 230 VAC with fuse 5 X 20 mm T315 ma according to IEC127-2/V Terminals 2.5 mm2 (stranded conductors), 4 mm2 (solid conductors) Ambient Sensor (VIA-DU-A10) PTC Sensor (IP54). Cable not included. Max length 100 m (2 x 1.5 mm2). Ambient operating temperature range 30 C to +80 C Terminals 2.5 mm2 Mounting Wall mounting Moisture Sensor (HARD-45) PTC Sensor. Supplied with 4 m cold lead. Extendable to 100 m (3 x 1.5 mm2). Power consumption 9 W to 18 W Ambient operating temperature range 30 C to +65 C continuous Supply voltage 230 VAC, +/ 10%, 50Hz (via control device) 1 / 8

1. Installation and Safety Remarks Select a suitable location for the enclosure and mount it on a wall using suitable screws. Install power cable, moisture and ambient sensor cables, RTD cables (which have to be connected in the ACS-30-EU-PCM2 module) into the enclosure using the glands supplied. Keep stopping plugs in unused gland entries. Remarks: Only for electricians! Attention: mistakes during connection of the device can cause damage to the control unit. Pentair Thermal Management is not liable for any damage caused by faulty connections and/or incorrect handling. Before working on the device, switch off the power supply! The device may only be connected and serviced by authorised, trained electricians. Electrical connection must be carried out in accordance with the enclosed connection diagram. The wires of the moisture sensor carry mains voltage, those of the temperature sensor and the alarm contact have to be considered as carrying mains voltage in consideration of VDE and the relevant installation regulations must be observed. Do not lay sensor cables together with other live wires in order to avoid electromagnetic interference. Local standards for electrical connection must be observed. If the device does not operate as expected, please check all connections and the mains power supply. 2. Installation and Dimensions of the Temperature Sensor A good positioning of the temperature sensor is crucial for the correct and efficient operation of the snow melting system. The temperature sensor should be placed on the North side of the building, in a position where it will always be away from direct sunlight. Moreover, it must be protected against other influencing factors such as being mounted above doors or windows or close to lamps or floodlights. A position on the wall just below a gutter is recommended. The connection wire of the sensor may be extended to max. 100 m at a lead diameter of 1.5 mm2. The wires of the temperature sensor has to be considered as carrying mains voltage according to VDE. The relevant installation regulations must be observed. Connection diagram see paragraph 6. Dimensions: 35 52 40 50 38 2 / 8 EN-RaychemACS30EMDR10-DS-EU0011 Rev2 THERMAL building SOLUTIONS

3. Installation and Dimensions of the Moisture Sensor A good positioning of the moisture sensor is crucial for the correct and efficient operation of the snow melting system. The moisture sensor and heating cable(s) served / controlled by the same control unit should be positioned in the same roof area. The moisture sensor is usually placed in a gutter at the lowest position in the system adjacent to one of the drainpipes. This is usually where water / snow is last cleared from the gutter, hence ensuring that the whole protected area is cleared before the heating system turns off. The exact positioning will depend on the particular building and the prevailing weather conditions. If the system shuts down before snow is removed from a key area, then the sensor should be moved to that area. For mounting the sensor in the gutter use the fixing brackets (Hard-46) to fix the sensor adjacent and parallel to the heating cable. Ensure that the sensor remains flat and is not in contact with the heating cable. The connection wire of the moisture sensor may be extended to max. 100 m at a lead diameter of 3 x 1.5 mm2. Connection diagram see paragraph 6. The wires of the moisture sensor are carrying mains voltage! 4 m 650 Dimensions: active sensor length 500 12 x 6 Ø 9, 5 4. Function R EMDR-10 AC 230V 50/60Hz IP 20 1 0 1 2 3 4 2 5 3 6 C Relais: 10(4)A, AC 230V Alarm: 2(1)A, AC 230V 3 4 5 6 7 8 2 9 1 10 Do not open while energized Nicht unter Spannung öffnen Ne pas ouvrir sous tension 20 15 20 30 40 10 25 10 50 TEST 5 0 60 C min T315mA IEC127 2/V PE PE PE 1 2 3 4 5 6 7 8 9 10 11 The control unit has four LEDs for indication of the operating conditions and four dials for the adjustment of different parameters. The air temperature is measured by means of a temperature sensor. When the air temperature falls below the value adjusted at the control unit, then the corresponding yellow LED will light up and after approx. 10 minutes the moisture sensor is activated. If moisture is present at the sensor then the corresponding yellow LED will light the controller will provide the signal to the PCM to switch ON the heater, as will the red LED. The heating cable remains on until the air temperature rises above the set value the moisture falls below the set value the air temperature falls below the adjusted lower temperature limit and the set post-heating period has elapsed. 4.1 Display Elements The LEDs indicate following operating conditions: LED green Device in operation (mains voltage) LED yellow Adjusted air temperature threshold exceeded LED flashes in case of fault at the air temperature sensor (break or short circuit) LED yellow Adjusted moisture threshold exceeded LED flashes in case of fault at the moisture sensor (break) LED red Status of heater ON 3 / 8

4.2 Parameter Adjustments The following parameters can be set by means of the respective dial: Adjustment of the air temperature threshold. The moisture sensor is being put into operation below this value. 3 4 5 6 7 8 2 9 1 10 Adjustment of the moisture threshold. Above this value the heating cable is being energized, if the air temperature is below the setpoint. 1 = max. sensitivity, 10 = min. sensitivity Adjustment of the lower temperature limit. Below this value the heating cable will be switched off. At the same time the moisture measurement will be switched off. In addition this dial can be used to test the unit by turning the potentiometer shaft fully to the left. After that the heating cable will be energized for max. 10 minutes. If the shaft is turned to the right again during these 10 minutes then the TEST will be stopped and the unit works in normal operation mode with the adjusted lower temperature limit. If the potentiometer is left in the TEST position then the unit will automatically return to normal operation mode after the test period of 10 minutes and works with a lower temperature limit of 25 C This lower temperature limit can be set to a different value at any time. A new test period can be activated by turning the shaft from fully left position to the right and then back again to the left stop. 20 30 40 10 50 0 60 min Adjustment of the post-heating period. The correct adjustment of the post-heating period is dependent on the local weather conditions, the location, and the requested heating power. The conditions have to match the requirements for an economical operation. Minimum time over which the heating cable stays activated when the conditions of temperature and humidity are no longer met e.g. temperature increases above set level or moisture is lower than set level. Use the following table as a guide: Description Suggested setting Air temperature threshold +2 C Moisture threshold 5 Lower temperature limit 15 C Post-heating period 60 minutes Periodic inspection: It is recommended to inspect and test the control unit as well as the heating cable circuits annually. 4.3 Moisture Sensor Fuse The control unit is equipped with a fuse in the output for the moisture sensor which protects this output against overload and short circuit. In case this fuse requires replacement you may exclusively use a fuse (5 x 20 mm) type T315mA according to IEC127-2/V. Other fuse types are not permissible and may lead to damage of the unit. 4 / 8 EN-RaychemACS30EMDR10-DS-EU0011 Rev2 THERMAL building SOLUTIONS

5. Fault Messages and Trouble Shooting The following faults are being detected by the control unit: Fault Break or short circuit of the temperature sensor Break of the moisture sensor Short circuit of the moisture sensor Power failure Reaction LED temperature flashes, alarm relay and load relay switch off LED humidity flashes, alarm relay and load relay switch off Additionally, under short circuit conditions, Moisture sensor fuse will rupture. Alarm relay and load relay switch off Notice: A short circuit at the moisture sensor leads to the triggering of the fuse. In case of a fault at the moisture sensor the moisture measuring circuit will be switched off. The LED moisture will continue to flash. After repair of the moisture sensor the fault signal has to be cleared by activating the TEST mode (turn the potentiometer for the lower temperature limit to the left stop and shortly after that back again to the requested lower temperature limit). When the air temperature falls below the value adjusted at the control unit, then the moisture sensor is activated and tested again after approx. 10 minutes. Trouble shooting: Symptoms Probable causes Correction Status of heater OFF active (snow is not melting) Temperature below set point, but status of heater OFF active Snow present, but status of heater OFF active Snow begins to clear, but the status of the heater turns off too soon Moisture sensor not positioned correctly (e.g. not flat in the gutter) Sensor section of this manual Temperature sensor located in direct sunlight Moisture not detected Less than 10 minutes have elapsed since the temperature fell below the setpoint below the setpoint Moisture dial set too high Poor positioning of the moisture sensor Poor positioning of the moisture Moisture dial set too low Temperature has fallen below minimum temperature setpoint Re-position following the instructions in the Assembly of the Moisture Re-position following the instructions in the Assembly of the Temperature Sensor section of this manual This is normal operation: low temperature AND moisture must be detected before the heating cable is energized The moisture sensor is not checked for the presence of moisture until 10 minutes after the temperature falls Set the moisture dial to a lower value Re-position following the instructions in the Assembly of the Moisture Sensor section of this manual Re-position following the instructions in the Assembly of the Moisture Sensor section of this manual Set the moisture dial to a higher value This is normal operation 5 / 8

6. Wiring Diagram 6.1 EMDR-10 with directly connected Heating Cable Attention: max. heating cable length 40 m, circuit breaker max. 10A (C-characteristic) L N PE ACS-30-EU-EMDR-10-MOD U1 EMDR-10 DC AC load Moisture sensor COM NC NO Alarm PE PE PE N N N L L LS T1 T2 ALARM 1.5 mm 2 Y ellow/green 1.5 mm 2 BLUE CLAIR 1.5 mm 2 BLACK A1 K1 A2 1mm 2 ORANGE X 1mm 2 ORANGE 1mm 2 ORANGE 11 1mm 2 ORANGE 14 12 1 2 3 PL PL PL X 51,1 Ω 200 Ω Moisture Sensor Ambient Sensor To RTD input on ACS-30-EU-PCM2 Output from the ACS-30-EU-EMDR-10-MOD is equivalent to an RTD connected as shown below: 1 2 3 6 / 8 EN-RaychemACS30EMDR10-DS-EU0011 Rev2 THERMAL building SOLUTIONS

Part Numbering and Ordering Description PCN Product Name Description EAN Code 1244-012865 ACS-30-EU-EMDR-10-MOD Roof & Gutter de-icing sensor for ACS-30 5414506014310 Related Products PCN Product Name Description EAN Code 1244-012864 ACS-30-EU-UIT2 User Interface module for the ACS-30 Control 5414506014303 and Monitoring System 1244-012866 ACS-30-EU-VIA-DU-20-MOD Snow melting and surface de-icing sensor 5414506014327 module for the ACS-30 Control and Monitoring System 1244-012867 ACS-30-EU- Remote monitoring module for the ACS-30 5414506014334 Moni-RMM2-E Control and Monitoring System 1244-012868 ACS-30-EU-PCM2-5-20A Power Control Module for ACS-30 5414506014341 (5 circuit module with 20 Amp 1244-012869 ACS-30-EU-PCM2-10-20A Power Control Module for ACS-30 5414506014358 (10 circuit module with 20 Amp 1244-012870 ACS-30-EU-PCM2-15-20A Power Control Module for ACS-30 5414506014365 (15 circuit module with 20 Amp 1244-012871 ACS-30-EU-PCM2-5-32A Power Control Module for ACS-30 5414506014372 (5 circuit module with 32 Amp 1244-012872 ACS-30-EU-PCM2-10-32A Power Control Module for ACS-30 5414506014389 (10 circuit module with 32 Amp 1244-012873 ACS-30-EU-PCM2-15-32A Power Control Module for ACS-30 (15 circuit module with 32 Amp 5414506014396 7 / 8

WWW.PENTAIRTHERMAL.COM United Kingdom Tel: 0800 969 013 Fax: 0800 968 624 salesthermaluk@pentair.com Ireland Tel: 1800 654 241 Fax: 1800 654 240 salesie@pentair.com All Pentair trademarks and logos are owned by Pentair or its global affiliates. Pentair reserves the right to change specifications without prior notice. 2015 Pentair. 8 / 8