Similar documents
Vacuum drying oven for non-flammable solvents

Manual piston sampler...m 11

CHEMICAL CLEANING UNIT Product number:

Hydraulic Control Solutions

Conlift1, Conlift2, Conlift2 ph+

High pressure reactors Where are your limits?

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

Product catalogue, pipe and sewer cleaning systems

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

UNITOR ULTRASONIC cleaning

Product catalogue, tank cleaning systems

Vertical selfpriming Side-Channel Pumps Type WPV

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Equipment Information

SanStar Series SSi and SSO Mixers SANITARY MIXERS

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Model 1210C Battery Powered Pump Shown. Description

SJT / SJM / SJP Large Vertical Pumps

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Puddle Flange. FRANK Puddle Flange

HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas

3/2-way Mini Solenoid Valve

CRN A-F-G-E-HQQE 3x400D 50 HZ

Assisted lift operated 2/2-way solenoid valves Type EV250B

Corrugated Tubular Heat Exchangers

The conditions below apply to the curves shown on the following pages.

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

swimming pool accessories

Tsurumi BER. Submersible Ejectors

SUPER 600. Tracked Paver SUPER 600. Pave Widths 0.5m 2.7m. Maximum Laydown Rate 200 tonnes/h. Clearance Width 1.2m

Industrial Cutting Equipment. includes new Concrete Crusher

Waterjets. propulsors. courtesy of Austal

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Workshop Compressors CLASSIC Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Direct steam injection humidifiers

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

Series description: Wilo-Yonos MAXO

Drive shaft, servicing

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Tubular connection elements

4" SUBMERSIBLE PUMPS

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

GEET Fuel Processor Plans

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Select Radiators Installation Guide

MONDOATHENS BASKETBALL SET (Reference PK110)

Itho Products for Hot and Boiling water. product-

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

Power consumption (kw)

WELDING & CUTTING MAIN EQUIPMENT

V47 Series Temperature Actuated Modulating Water Valves

MFP14, MFP14S and MFP14SS Automatic Pumps

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Series description: Wilo-Yonos MAXO-D

Operators manual Basic water heater

Bypass level indicator With magnetic display Model BNA

Installation and instruction manual for Laing DDC pumps

AIR OPERATED OIL PUMPS AND KITS

Laing industrial pumps

Steam System Best Practices Condensate System Piping

VALVE TECHNOLOGY ONE STEP AHEAD.

This instruction is valid for all ACD pump models shown on page 2

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

AUTOCLAVES. Table Top. STE-TEN, 1 Liter Autoclave

Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

Baumann Flexsleev Sanitary Control Valve

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

VALVE TECHNOLOGY ONE STEP AHEAD.

Jet Propulsion System

Quality power tools since 1919 NEW GENERATION. Stirrers and mixing stations

Solenoid valves 2/2-way direct-operated Type EV210A

Also special and personalized items with logo for various applications are realized at short notice.

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

Screw Plug Immersion Heaters

Type 3353 Angle Seat Valve

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

TELESCOPE Motorized Lighting Suspension

UNITOR VACUUM cleaners

1300 MAXTRAK SPECIFICATION

3/2-way Solenoid Valve, direct-acting, NC or NO

Transcription:

Guth Portable gitators R The long-term solution

pplications Guth Portable gitators R are used for the mixing, stirring and the homogenization of water-like or medium viscosity products. They are most often used in wine cellars for the production of wine and sparkling wine, but are also utilized in other areas of the food and beverage industries in which gentle and effective mixing is required. The classic characteristics of the R series agitators are their lasting durability and their gentle efficiency. They are an important partner in winemaking throughout the world due to their first rate mixing results. The Guth Portable gitator R is the unparalleled, long-term solution for every mixing problem. Possible applications for the R agitator include: Stirring of liquids to prevent deposit of turbids and other solid substances as well as stirring of the dregs for biological acid reduction. chievement of homogeneous mixtures, even if the two liquids have different specific gravities. larification and homogenization during blending. Mixing of liquids with solid or gaseous products such as fining agents, sulfuric acid or carbonic acid. Emulsification of sterile preparations and the homogenization of distillations. cting as a catalyst for reactions such as fermentation, dissolving sugar and spreading sugar solutions. Increasing the efficiency of artificial cooling and heating, and uniform penetration during cooling operations. Stirring of the dregs helps to increase the activity in slow fermentations.

haracteristic Features Gentle stirring and mixing in combination with unmatched mixing results! The special bearing of the agitator shaft inside the hollow shaft of the motor ensures smooth running, free of vibrations. Installation and removal is possible on filled vessels, which means one agitator can be used for a number of tanks - no pumping from one tank to another. The mixing process takes very little time! This makes work more efficient without annoying waiting times. Lasting durability, even under the toughest of conditions. The convenient lightweight agitators are easily portable and, if desired, they can even be mounted onto a support stand. The slide ring seal guarantees trouble-free functioning even during continuous service (up to 10 bar). For highly aggressive liquids greater durability seals can be supplied. The various sizes of the R series allow you to choose the optimal and most cost-efficient solution depending on your tank size, type and medium. No loss of product or pressure during installation on and removal from full tanks! Simple and quick installation and de-installation onto different tank fittings and threads (e.g. Pfalz, Mainz, Garolla, Macon) - no special tools or devices needed! ll parts in contact with the product are made of stainless steel! In cases of extremely high corrosion resistance requirements these parts can also be made of alternative stainless steel types. Wide range of accessories for numerous applications! ssistance concerning the optimal installation position and angle as well as an individual installation drawing included!

Installation Guth Portable gitators R can be flexibly installed onto various tank fittings. screw connection (liner/nut) connects the agitator directly with the fitting. ll tank fittings with a fullport design and an inner diameter of at least 32 mm are suitable, e.g. ball valves, inclined seat valves, drain valves and tap closing valves. Installation examples Tank wall Tank wall Installation to ball valve Installation to inclined seat valve Tank wall Tank wall Installation to drain valve Installation to tap closing valve (here the buffer tube is to be used in order to prevent damages to the shaft) Guth Portable gitators R can also be fastened to open tanks and vats when vertical stirring is sought, e.g. for producing sugar solutions and fining agents djusting directions: vertical/installation angle Material: Malleable cast iron/brass Installation at special mounting plate

Installation ccording to the size and form of the tank, the optimum installation position and angle can vary. We will be glad to assist you in determining the optimum installation position for your tank. Below are a few examples: gitator at tank with round bottom gitator at tank with conical bottom gitator at tank with sloping bottom gitator at tank with flat bottom We will be happy to assist you with an individual installation drawing. In order to do so we would need all relevant information about the tank when placing your order: height, diameter, bottom type, media, etc.

ccessories Propeller Types Pivoted Blade Propeller The pivoted blade propeller (standard) is mainly used to allow an installation on full tanks. It will be introduced while folded and spreads its blades when the engine is started. Three-blade Propeller The use of this rigid propeller improves the dissolving of sugar, fining agents and similar agents in open tanks and vats. Mixing Head The mixing head is a three-blade propeller with an additional protection ring to prevent damages during the working process in open tanks and vats. Gassing Unit Buffer Tube special flange housing with an inlet valve made of chrome-nickel steel allows direct injection of sulfur dioxide (SO²), carbon dioxide (O²) and the like, while the agitator is running. Thus when gasses are added to the liquid they are intensively mixed immediately upon their introduction. Gassing unit: DN 10 with hose nozzle Material: chrome-nickel steel, highly polished The use of the buffer tube allows the agitator to be used at tap closing valves and similar special fittings without damage being done to the agitator shaft at installation and de-installation. Material: chrome-nickel steel, highly polished

ccessories Mobile Support Stands The mobile support stand holds the agitator when in use. They facilitate installation and removal and ensure that all movements can be carried out in an ergonomic way. They also relieve the tank fitting from additional weight. For the agitator type R 300 a mobile support stand is strongly recommended. Sitting Type Dimensions (in mm) Size 0 Size 1 Size 2 Size 3 F G H1 H2 H3 H4 R 45 E R 110 E R 300 E 250 250 250 250 500 500 500 700 450 500 650 950 600 700 1000 1500 1060 1060 1060 1060 170 170 170 170 440 440 440 440 425 425 425 425 420 420 420 650 475 475 475 475 400 400 400 400 420 420 420 650 675 675 675 675 450 450 450 450 470 470 470 700 Hanging Type adjusting range V2 Dimensions (in mm) Standard-Execution B 435 600 1200 V1 V2 300-1000 300 adjusting range V1 Upon request the mobile support stand hanging type is also available in special dimensions. Both mobile support stands are easy to disassemble and thus effortless to transport.

Dimensions and Technical Data Left-hand thread Threaded connection Tank volume 1 Power Voltage Frequency Rounds p.m. Nominal current Weight Length 2 Standard Shaft (maximum length 1200) Propeller Ltr. KW V Hz R/min kg B D E R 45 R 110 R 300 R 20/95 20.000 0,45 230/400 50 1500 2,3 / 1,3 16 440 3 800 425 18 147x25 50.000 1,1 230/400 50 1500 4,8 / 2,8 22 475 3 800 400 18 175x30 100.000 3 230/400 50 1500 12 / 7 42 675 3 1000 450 28 220x35 20.000 0,20 / 0,95 0,20 / 0,95 230 400 50 50 750 / 1500 750 / 1501 2,5 / 2,5 1,45 / 1,45 22 475 3 800 400 18 160x30 ¹ The information refer to water-like media ² ll dimensions in mm ³ If with standard liner/nut connection Special engines and connections, longer shafts, and elongated cables are available upon request. Specification dvice The length of the shaft (H) that enters into the tank should amount at least 150 mm. This means that for the minimum length of the shaft: Bmin = + F + H (= 150 mm) + G (length of the tank fitting). Especially in cases of tanks with thick walls (brick and mortar) and long tank fittings it is recommended to lengthen the shaft. Guth Ventiltechnik GmbH & o. KG Horstring 16, Postfach 1309 D-76829 Landau, Germany Tel.: +49 (63 41) 51 05-0, Fax: +49 (63 41) 51 05-85 www.guthventiltechnik.de, e-mail: info@guthventiltechnik.de