SE-701 MANUAL GROUND-FAULT MONITOR



Similar documents
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Telephone- and leased line modem for industrial applications TD-36

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

RM4TG20 three-phase network control relay RM4-T - range V

Waveguide Access Point WGA631. Product Guide

ATC-300 Automatic Transfer Switch Controller

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Rack mounted telephone- and leased line modem for industrial applications

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Arc Terminator Active Arc-Resistant Switchgear

CompactLogix Power Supplies Specifications

Energy Management Energy Meter Type EM23 DIN

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

38 Series - Relay interface modules A

White Paper Mervin Savostianik P. Eng. Littelfuse, Inc.

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Voltage Regulator SPAU 341 C. Product Guide

MasterINTERFACE 39 Series - Relay interface modules

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Power Meter Series 700

38 Series - Relay interface modules A

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Advantium 2 Plus Alarm

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Water Leak Detection System

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Analog signal converters CC-E I/I Current / current isolators

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

STRATO LED Drivers 70W, Single output

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Three-phase monitoring relay CM-PFE

Power Supplies 3. SDN-P DIN Rail Series

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Quick Connect. quick - simple - efficient.

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

MCR1900 Media Converter 19-Slot Chassis

SURGE PROTECTIVE DEVICES

MasterINTERFACE 39 Series - Relay interface modules

Safety Manual BT50(T) Safety relay / Expansion relay

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Trip circuit supervision relay. Type RXTCS

80 Series - Modular timers 16 A. Features

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Thermistor motor protection

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Solid State Timers Type F

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Operating Manual UWAPS-TINY Series

GTEC transfer switch open transition

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

HMI display Installation Guide

15 Series - Electronic step relay and dimmer. Features SERIE

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

80 Series - Modular timers 16 A. Features

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Cross-beam scanning system to detect slim objects. 100 mm in

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

, User s Manual

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

A project to optimise quality and energy efficiency must include metering

T7560A,B,C Digital Wall Module

Duct Humidity Transmitter

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Capacitor Protection Relay SPAJ 160 C. Product Guide

EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

How To Test A Power Distribution Unit

HP UPS R1500 Generation 3

Transcription:

3714 Kinnear Place Saskatoon, SK Canada S7P 0A6 Ph: (306) 373-5505 Fx: (306) 374-2245 www.littelfuse.com/relayscontrols SE-701 MANUAL GROUND-FAULT MONITOR Revision 10-C-072414 Copyright 2014 by Littelfuse Startco All rights reserved. Document Number: PM-1040-EN Printed in Canada.

Page i This page intentionally left blank.

Page ii SECTION TABLE OF CONTENTS PAGE FIGURE LIST OF FIGURES PAGE 1 Introduction... 1 1.1 General... 1 1.2 Current-Sensor Selection... 1 2 Operation... 1 2.1 Configuration-Switch Settings... 1 2.1.1 Relay Operating Mode... 1 2.1.2 Trip Inhibit... 1 2.1.3 CT Verification... 1 2.1.4 Filter Selection... 1 2.1.5 Reset Mode... 1 2.2 Front-Panel Controls... 2 2.2.1 Ground-Fault Trip Level... 2 2.2.2 Ground-Fault Trip Time... 2 2.2.3 Reset... 2 2.2.4 Test... 2 2.3 Front-Panel Indication... 2 2.3.1 Power... 2 2.3.2 Trip... 2 2.3.3 Trip Inhibit... 2 2.4 Analog Output... 2 2.5 Self Diagnostics... 2 3 Installation... 3 4 SE-701 Compatibility... 6 5 Technical Specifications... 14 6 Ordering Information... 16 7 Warranty... 17 8 Ground-Fault Performance Test... 18 Appendix A SE-701 Revision History... 20 1 SE-701 Outline and Mounting Details...4 2 Typical Connection Diagrams...5 3 Typical Three-Phase-Starter Connection...5 4 EFCT-1 Outline and Mounting Details...7 5 EFCT-2 Outline and Mounting Details...8 6 EFCT-26 and SE-CS30-26 Outline and Mounting Details...9 7 SE-CS30-70 Current Sensor... 10 8 SE-CS30-4, -5, and -8 Current Sensors... 11 9 PMA-55 Panel-Mount Adapter...12 10 PMA-60 Panel-Mount Adapter...13 11 PGA-0500 Analog Percent Current Meter...14 12 Ground-Fault-Test Circuits...18 TABLE LIST OF TABLES PAGE 1 Trip-Features Comparison...6 2 Ground-Fault-Test Record...19 DISCLAIMER Specifications are subject to change without notice. Littelfuse Startco is not liable for contingent or consequential damages, or for expenses sustained as a result of incorrect application, incorrect adjustment, or a malfunction.

Page iii This page intentionally left blank.

Page 1 1. INTRODUCTION 1.1 GENERAL The SE-701 is a microprocessor-based ground-fault monitor for resistance-grounded and solidly grounded systems. It is uniquely suited for use on systems with significant harmonic content. Its output relay can operate in the fail-safe or non-fail-safe mode for undervoltage or shunt-trip applications. The SE-701 has one output relay with isolated normally open and normally closed contacts for use in independent control circuits. Additional features include LED trip, power, and inhibit indication, autoreset or latching trips with front-panel and remote reset, trip memory, test button, self diagnostics, 0- to 5-V analog output, inputs for ground-fault current sensors, CT verification for EFCT-series current sensors, digital selector switches, switch-selectable algorithms for fixedfrequency or variable-frequency applications, and an inhibit that can be enabled to prevent the output relay from operating during a high-current ground fault. Ground-fault current is sensed by a current transformer. Core-balance zero sequence current sensors (CT's) are most commonly used. Bus bar or toroid style CT's can also be used on the neutral to ground connection. See Fig. 2 in Technical Note CT-08 available at www.littelfuse.com. The trip level of the ground-fault circuit is switch selectable in 1% increments from 1 to 99% of the CT rating. 1.2 CURRENT-SENSOR SELECTION An SE-701 has inputs for 1-, 5-A, and 50-mA-secondary CT s. Choose a CT that provides the required ground-faulttrip range. For ground-fault detection, the ground-fault trip level must be substantially below the prospective ground-fault current. In a solidly grounded system, prospective groundfault current is similar to phase-fault current. In a resistancegrounded system, prospective ground-fault current is defined by the neutral-grounding-resistor let-through-current rating. In a solidly grounded system, protection against arcing ground faults requires a ground-fault CT that will detect low-level fault current but not saturate up to the operating value of the system overcurrent protection. In general, immunity to saturation is proportional to CT mass. To eliminate nuisance tripping, surge current must not saturate the CT. For low-level ground-fault protection use an EFCT-1, EFCT-2, or EFCT-26 earth-fault CT with a 5-A-primary rating. However, protection at this level might not be possible because of high surge current or prospective ground-fault current. For CT-selection assistance, see Technical Note CT-01 available at www.littelfuse.com/relayscontrols. 2. OPERATION 2.1 CONFIGURATION-SWITCH SETTINGS See Fig. 1. 2.1.1 RELAY OPERATING MODE Switch 1 is used to set the operating mode of the output relay. In the fail-safe mode, the output relay energizes when the ground-fault circuit is not tripped. In the failsafe mode, non-volatile memory retains the trip status of the SE-701. If tripped, and the supply voltage is cycled, the SE-701 will remain tripped, with the trip relay de-energized and the TRIP LED on, until reset. In the non-fail-safe mode, the output relay energizes when a ground-fault trip occurs. In the non-fail-safe mode, trip status is not retained in non-volatile memory. 2.1.2 TRIP INHIBIT Switch 2 is used to select Class I or Class II operation. In the OFF position, high-current trip inhibit is off for Class I operation. In the ON position, high-current trip inhibit is on for Class II operation. If high-current trip inhibit is on and ground-fault current escalates above eleven times the CT-primary rating before the groundfault circuit trips, the output relay will not operate until ground-fault current falls below eight times the CTprimary rating. This feature allows overcurrent protection to operate in applications where the ground-fault current can be larger than the interrupting capacity of the device tripped by the SE-701. 2.1.3 CT VERIFICATION Switch 3 is used to enable CT verification with an EFCT-series CT. In the ON position, a trip will occur if the CT is disconnected. Switch 3 must be in the OFF position when an EFCT-series CT is not used and must be in the ON position when an EFCT is used. 2.1.4 FILTER SELECTION Switch 4 is used to select the filtering algorithm for a fixed-frequency (50/60 Hz) or variable-frequency application. The FIXED FREQUENCY setting uses a DFT filter that allows lower trip levels to be used by rejecting harmonics that can cause nuisance tripping. The VARIABLE FREQUENCY setting uses a peakdetection algorithm with a wider bandwidth for fault detection in variable-frequency drive applications. 2.1.5 RESET MODE Switch 5 is used to select autoreset or latching trips. See Section 2.2.3.

Page 2 2.2 FRONT-PANEL CONTROLS 2.2.1 GROUND-FAULT TRIP LEVEL The % CT PRIMARY selector switches are used to set the ground-fault trip level as a percentage of the CT-primary rating. In tripping systems, a ground-fault trip level of 10 to 20% of the prospective ground-fault current is often used. In alarm-only systems, a value of 50% of the prospective ground-fault current is often used. To avoid sympathetic tripping, the trip level must be above the charging current of the protected feeder. A 0% selection provides protection at 1%. 2.2.2 GROUND-FAULT TRIP TIME The SE-701 has a definite-time trip characteristic. The TIME (s) selector switch is used to set the ground-fault trip delay time for coordination with upstream and downstream ground-fault devices. Coordination requires the same trip level for all ground-fault devices in a system and the trip time to progressively increase upstream. The amount of equipment removed from the system will be a minimum if the first ground-fault device to operate is the one immediately upstream from the fault. 2.2.3 RESET If the Reset Mode switch is in the LATCHING position, a trip remains latched until the RESET button is pressed or the remote-reset terminals are momentarily connected. In the non-fail-safe mode, cycling the supply voltage will also reset the SE-701. If the Reset Mode switch is in the AUTORESET position, a trip will reset when the fault is removed. The reset circuit responds only to a momentary closure so that a jammed or shorted button will not prevent a trip. The front-panel RESET button is inoperative when the remote-reset terminals (6 and 7) are connected. indicates a trip initiated by a CT fault. Two fast flashes indicate a diagnostic trip. See Section 2.5. 2.3.3 TRIP INHIBIT The yellow LED labelled INHB indicates that outputrelay operation was inhibited during a high-current ground fault. See Section 2.1.2. When a ground-fault trip occurs during a high-current ground fault, both the TRIP and INHB LED s will be ON. Inhibit indication is reset when the ground-fault trip is reset. Inhibit operation and indication will not respond if the trip-inhibit switch is in the OFF position. 2.4 ANALOG OUTPUT The non-isolated, 0- to 5-V analog output indicates ground-fault current sensed by the ground-fault CT. The output is 5 V when ground-fault current is 100% of the CT-primary rating. Use a PGA-0500 Analog Percent Current Meter with the PGA-05CV Voltage Converter to indicate ground-fault current. See Figs. 2, 3, and 11. 2.5 SELF DIAGNOSTICS A diagnostic trip is indicated by two fast flashes of the TRIP LED. It can be caused by a diagnostic problem detected by the watchdog timer or from an incorrect reading from non-volatile memory. Press RESET or cycle supply voltage. If the problem persists, contact Littelfuse Startco. 2.2.4 TEST The TEST button is used to test the ground-fault circuit, the indication, and the output relay. When the TEST button is pressed for one second, a test signal is applied to the ground-fault-detection circuit, the circuit will trip, the TRIP LED will light, and the output relay will operate. If high-current inhibit has been selected, the INHB LED will light. 2.3 FRONT-PANEL INDICATION 2.3.1 POWER The green LED labelled PWR indicates the presence of supply voltage. 2.3.2 TRIP The red LED labelled TRIP indicates a trip. A solid red LED indicates a ground-fault trip. A flashing LED

Page 3 3. INSTALLATION NOTE: Mounting, terminal-block connections, and wiring must conform to applicable local electrical codes. Check all applicable codes prior to installation. An SE-701 can be surface or DIN-rail-mounted. See Fig. 1. Panel mounting requires a PMA-55 or PMA-60 Panel-Mount Adapter. See Figs. 9 and 10. Use terminal 11 (L1) as the line terminal on ac supply systems or the positive terminal on dc supply systems. Use Terminal 10 (L2/N) as the neutral terminal on ac systems or the negative terminal on dc systems. Connect terminal 9 ( ) to ground. Pass the phase conductors through the CT window for 4-wire and single-phase systems also pass the neutral conductor through the CT window, as shown in Figs. 2 and 3. Do not pass ground conductors through the CT window. In applications that require shields or drain wires to pass through the CT window, return them through the CT window before connecting them to ground. If a ground-fault CT with a 5-A secondary is used, connect it to terminals 2 and 3 (terminals 1 and 3 with a 1-A secondary) and ground terminal 3. If an EFCT-x is used, connect it to terminals 4 and 5, connect the shield to terminal 5, and ground terminal 5. Set configuration switch 3 to ON. Remove the connection to terminal 9 for dielectric-strength testing all inputs and outputs have ANSI/IEEE C37.90 surge-protection circuits that conduct above 300 Vac. See Figs. 4, 5, and 6 for EFCT-series dimensional drawings and Figs. 6, 7, and 8 for the SE-CS30-series current sensors.

Page 4 8.7 (0.34) 55.0 (2.17) 37.5 (1.48) CONFIGURATION SWITCHES CONFIGURATION SWITCHES RESET MODE 5 LATCHING AUTORESET FILTER SELECTION 4 FIXED VARIABLE FREQUENCY FREQUENCY CT VERIFICATION 3 OFF ON TRIP INHIBIT 2 OFF ON RESET MODE FILTER SELECTION CT VERIFICATION TRIP INHIBIT RELAY OPERATING MODE LATCHING FIXED FREQUENCY OFF OFF FAIL-SAFE 5 4 3 2 1 AUTORESET VARIABLE FREQUENCY ON ON NON-FAIL-SAFE NOTE 2 61.2 (2.41) 75.0 (2.95) RELAY OPERATING MODE FAIL-SAFE 1 NON-FAIL-SAFE NOTE 5 1A 5A C S1 S2 RS 1A/5A CT EFCT RESET ANALOG OUTPUT 1 2 3 4 5 6 7 8 MOUNTING DETAIL 6.9 (0.27) TOP 55.0 (2.17) 118.0 (NOTE 3) (4.65) 110.0 (4.33) 6.3 (0.25) LITTELFUSE STARTCO GROUND-FAULT MONITOR SE-701 PWR INHB TRIP 4 3 2 1 5 5.50 0 6 7 8 9 4 3 2 1 0 6 7 8 9.40.30.20.10.05 % CT PRIMARY TIME (s) 1.0 1.5 2.0 2.5 75.0 (2.95) TEST RESET FRONT NOTES: SIDE 9 10 11 12 13 14 15 L2 N L1 BOTTOM 16 1. DIMENSIONS IN MILLIMETRES (INCHES). 2. MOUNTING SCREWS: M4 OR 8-32. 3. OVERALL DIMENSION WHEN MOUNTED ON DINEN50022 35 mm x 7.5 mm TOP-HAT RAIL. 4. ADJUSTMENT KNOBS ARE REMOVABLE. 5. CONFIGURATION SWITCHES SHOWN IN DEFAULT POSITION. FIGURE 1. SE-701 Outline and Mounting Details.

Page 5 Ø A XXX:5 Ø A XXX:5 L XXX:5 Ø B Ø B N Ø C Ø C N N N 14 2 3 L N 1 2 3 4 5 1 A 5 A C S1 S2 11 L2 10 L1 N 13 14 ISOLATED CONTACTS 15 16 14 2 3 SE-701 3-PHASE, 4-WIRE CONNECTION SE-701 1-PHASE CONNECTION XXX:1 OR EFCT-X OR CS30-X REMOTE RESET 6 7 LEAKAGE 8 I PGA-05CV PGA-0500 RS G Y R SE-701 RESET ANALOG OUTPUT INDICATION PWR INHB TRIP 9 NOTE: 1. RELAY CONTACTS SHOWN WITH SE-701 DE-ENERGIZED. 1 2 3 4 5 1 A 5 A C S1 S2 SE-701 Technical Note CT-01 provides additional information on CT selection. ALTERNATE CT CONNECTIONS 3-PHASE, 3-WIRE CONNECTION FIGURE 2. Typical Connection Diagrams. Ø A XXX:5 Ø B Ø C L N 1 2 3 4 5 1 A 5 A C S1 S2 13 14 ISOLATED CONTACTS 15 16 STOP START 1M 1M O/L 11 L1 L2 10 N REMOTE RESET SE-701 6 RS RESET 7 LEAKAGE ANALOG I 8 OUTPUT 9 PGA-05CV PGA-0500 INDICATION NOTES: 1. RELAY CONTACTS SHOWN WITH SE-701 DE-ENERGIZED. G Y R PWR INHB TRIP FIGURE 3. Typical Three-Phase-Starter Connection.

Page 6 4. SE-701 COMPATIBILITY The current SE-701 has been enhanced with the addition of non-volatile trip memory for the fail-safe relay operating mode. Prior to hardware revision 07, a mechanical flag was used instead of non-volatile trip memory. The current revision of the SE-701 can directly replace previous revision 00 to 06 units. Beginning with hardware revision 09, CT verification must be enabled when used with an EFCT-series earth-fault CT. Previous-revision SE-701 units used with EFCT-series CT s can operate with CT verification enabled or disabled. See Section 2.1.3. The hardware-revision number is listed on the SE-701 model/serial-number label affixed to the SE-701 enclosure. The SE-701 generations are compared in Table 1. The SE-701 was previously available with SE-701-01 120-Vac and SE-701-02 240-Vac supply-voltage options. These have been discontinued. An SE-701-0U 120/240 Vac/Vdc unit can directly replace an SE-701-01 or SE-701-02. TABLE 1. TRIP-FEATURES COMPARISON HARDWARE REVISION 00 to 06 07 09 LED trip indication Yes Yes Mechanical flag trip indication Yes No Non-volatile trip memory No Yes Device state after supply voltage cycled when tripped (ground-fault removed) Fail-safe Non-fail-safe Trip LED: Off Trip relay: Energized Trip flag: Red Trip LED: Off Trip relay: De-energized Trip flag: Red Trip LED: On Trip relay: De-energized Trip LED: Off Trip relay: De-energized CT Detection must be ON for EFCT No No Yes

R SE-701 Ground-Fault Monitor Page 7 NOTES: 1. DIMENSIONS IN MILLIMETRES (INCHES). 2. MOUNTING SCREWS: M4 OR 8-32. 3. PRESS MOUNTING FEET IN PLACE USING INSTALLATION TOOL PROVIDED. 4. RoHS COMPLIANT. 5. EN 60044-1 COMPLIANT. 20.5 (0.81) 121.0 (4.76) 121.0 (4.76) 80.0 (3.15) 30.0 (1.18) 56.0 (2.21) 46.0 (1.81) NOTE 2 M5 SCREWS TOP 25.0 (0.98) MOUNTING DETAIL 30.0 (1.18) EFCT-1 EARTH FAULT CT 600 V CLASS, INSULATION CLASS A R LR 53428 C US 138.0 MAX (5.43) EFCT - 1FC FLUX CONDITIONER (OPTIONAL) 82.0 (3.23) 69.8 (2.75) 5.0 (0.20) Ø RECESSED FOR 8-mm HEX NUT 1.0 (0.04) DEEP 22.0 (0.87) 126.0 (4.96) 5.5 (0.22) 110.0 (4.33) 5.5 (0.22) 56.0 (2.21) FRONT SIDE FIGURE 4. EFCT-1 Outline and Mounting Details.

R R SE-701 Ground-Fault Monitor Page 8 NOTES: 1. DIMENSIONS IN MILLIMETRES (INCHES). 2. MOUNTING SCREWS: M5 OR 10-32. 3. RoHS COMPLIANT. 4. EN 60044-1 COMPLIANT. 215.0 (8.46) 26.5 (1.04) 215.0 (8.46) 162.0 (6.38) 64.0 (2.52) 31.0 (1.22) P2 S1 S P 2 1 52.3 (2.06) M5 OR 10-32 TAP M5 SCREWS TOP 25.0 (0.98) MOUNTING DETAIL 31.0 (1.22) EFCT-2 EARTH FAULT CT 600 V CLASS, INSULATION CLASS A LR 53428 C US 236 MAX (9.29) 139.7 (5.50) FLUX CONDITIONER (INCLUDED) BONDING SCREW 5.0 (0.20) DIA 215.0 (8.46) 60.0 (2.36) 8.5 (0.33) 198.0 (7.80) 8.5 (0.33) FRONT SIDE FIGURE 5. EFCT-2 Outline and Mounting Details.

R SE-701 Ground-Fault Monitor Page 9 17.0 (0.67) 68.0 (2.68) 68.0 (2.68) 34.0 (1.34) 26.5 (1.04) 52.5 (2.07) 42.6 (1.68) M4 OR 8-32 TAP 110.0 MAX (0.43) M5 SCREWS TOP 25.0 (0.98) MOUNTING DETAIL 26.5 (1.04) SE-CS30-26 CURRENT SENSOR C R US LR 53428 72.0 (2.83) 26.0 (1.02) 4.0 (0.16) Ø RECESSED FOR 7-mm HEX NUT 3.0 (0.12) DEEP 34.0 (1.34) 58.0 (2.28) 7.0 (0.87) 5.0 (0.20) FRONT 5.0 (0.20) 52.5 (2.07) SIDE NOTES: 1. DIMENSIONS IN MILLIMETRES (INCHES). 2. PRESS MOUNTING FEET IN PLACE USING INSTALLATION TOOL PROVIDED (DETAIL A ). DETAIL A MOUNTING FOOT INSTALLA TION TOOL 3. MOUNTING SCREWS: M4 OR 8-32. 4. RoHS COMPLIANT. 5. EN 60044-1 COMPLIANT. 6. SE-CS30-26 SHOWN. FIGURE 6. EFCT-26 and SE-CS30-26 Outline and Mounting Details.

R R SE-701 Ground-Fault Monitor Page 10 20.5 (0.81) 121.0 (4.76) 121.0 (4.76) 80.0 (3.15) 30.0 (1.18) 56.0 (2.21) 46.0 (1.81) NOTE 3 M5 SCREWS TOP 25.0 (0.98) MOUNTING DETAIL 30.0 (1.18) SE-CS30-70 CURRENT SENSOR C US LR 53428 138.0 MAX (5.43) 69.8 (2.75) Ø 5.0 (0.20) RECESSED FOR 8-mm HEX NUT 1.0 (0.04) DEEP 126.0 (4.96) 22.0 (0.87) 5.5 (0.22) 110.0 (4.33) FRONT 5.5 (0.22) 56.0 (2.21) SIDE MOUNTING FOOT INSTALLATION TOOL NOTES: 1. DIMENSIONS IN MILLIMETRES (INCHES). 2. PRESS MOUNTING FEET IN PLACE USING INSTALLATION TOOL PROVIDED (DETAIL A ). 3. MOUNTING SCREWS: M4 OR 8-32. DETAIL A 4. RoHS COMPLIANT. 5. EN 60044-1 COMPLIANT. FIGURE 7. SE-CS30-70 Current Sensor.

Page 11 C J D H G TOP (COVER REMOVED) F 72.0 (2.83) 14.0 (0.55) MOUNTING DETAIL SE-CS30-8 OUTLINE NOTES: 1. DIMENSIONS IN MILLIMETRES (INCHES). A B 2. MOUNTING SCREWS: M5 OR 10-32. 3. RoHS COMPLIANT. 4. CE COMPLIANT. E FLUX CONDITIONER DIMENSIONS SE-CS30-4 SE-CS30-5 SE-CS30-8 A 95.0 (3.74) 130.0 (5.12) 200.0 (7.87) B 175.0 (6.89) 218.0 (8.78) 309.0 (12.17) FRONT 1.7 (0.07) C D 158.0 (6.22) 141.0 (5.55) 203.0 (7.99) 178.0 (7.01) 290.5 (11.44) 267.5 (10.50) E 82.0 (3.22) 103.5 (4.07) 150.0 (5.90) G F 32.0 (1.26) 32.0 (1.26) 34.0 (1.34) I K G 17.5 (0.69) 11.0 (0.43) 11.0 (0.43) L D C BOTTOM J H I J 15.0 (0.59) 33.0 (1.30) 9.0 (0.35) 13.3 (0.52) 34.0 (1.34) 11.0 (0.43) 13.3 (0.52) 43.0 (1.69) 11.5 (0.45) K 40.0 (1.57) 40.0 (1.57) 50.0 (1.97) L 5.3 (0.21) 7.0 (0.28) 7.0 (0.28) FIGURE 8. SE-CS30-4, -5, and -8 Current Sensors.

Page 12 85.0 (3.35) 110.0 (4.33) PANEL THICKNESS 1.6 (0.06) TO 4.8 (0.19) 6-32 42.5 (1.67) LITTELFUSE STARTCO GROUND-FAULT MONITOR PWR INHB TRIP SE-701 5 5.50 4 6 4 6.40 1.0 3 7 3 7.30 1.5 2 8 2 8.20 2.0 1 9 1 9.10 2.5 0 0.05 % CT PRIMARY TIME (s) 85.0 (3.35) 6-32 75.0 (2.95) TEST RESET FRONT VIEW BEZEL BRACKET SIDE VIEW 55.0 (2.20) WIDE MONITOR 42.5 (1.67) 30.0 (1.18) 6.0 (0.24) 85.0 (3.35) 72.0 (2.83) 60.0 (2.36) 2.0 (0.08) RAD MAXIMUM 4.0 (0.16) DIA 8.7 (0.34) DIA 4.3 (0.17) RAD ALTERNATE CONFIGURATIONS 6.0 (0.24) 9.5 (0.37) 60.0 (2.36) 79.0 (3.11) INSTALLATION INSTRUCTIONS: 1. REMOVE BEZEL AND LATCH MONITOR ON BRACKET. 2. INSERT BRACKET THROUGH FRONT OF PANEL CUTOUT AND SECURE WITH FLAT WASHERS AND LOCKNUTS PROVIDED. 3. CONNECT WIRING TO TERMINALS. 4. INSTALL BEZEL USING 6-32 x 0.31 SCREWS PROVIDED. NOTE: 1. DIMENSIONS IN MILLIMETRES (INCHES). 9.5 (0.37) PANEL CUTOUT DETAIL FIGURE 9. PMA-55 Panel-Mount Adapter.

Page 13 99.0 (3.90) 116.0 (4.57) PANEL THICKNESS 1.6 (0.06) TO 4.8 (0.19) M4 44.0 (1.73) LITTELFUSE STARTCO GROUND-FAULT MONITOR SE-701 PWR INHB TRIP 5 5.50 4 6 4 6.40 1.0 3 7 3 7.30 1.5 2 8 2 8.20 2.0 1 9 1 9.10 2.5 0 0.05 % CT PRIMARY TIME (s) 88.0 (3.46) M4 75.0 (2.95) TEST RESET FRONT VIEW TRANSPARENT COVER (NOTE 2) BRACKET SIDE VIEW 55.0 (2.20) WIDE MONITOR 44.0 (1.73) 30.0 (1.18) 6.0 (0.24) 99.0 (3.90) 72.0 (2.83) 60.0 (2.36) 2.0 (0.08) RAD MAXIMUM 4.5 (0.18) DIA 8.7 (0.34) DIA 4.3 (0.17) RAD 6.0 (0.24) 9.5 (0.37) 60.0 (2.36) 79.0 (3.11) INSTALLATION INSTRUCTIONS: 1. WITH COVER REMOVED LATCH MONITOR TO BRACKET. 2. INSERT BRACKET THROUGH FRONT OF PANEL CUTOUT AND SECURE WITH FLAT WASHERS AND LOCKNUTS PROVIDED. 3. CONNECT WIRING TO TERMINALS. 4. ATTACH COVER USING SECURITY SCREWS OR THUMB SCREWS PROVIDED. NOTES: ALTERNATE CONFIGURATIONS 1. DIMENSIONS IN MILLIMETRES (INCHES). 2. MEETS NEMA3, IP53. PANEL CUTOUT DETAIL 9.5 (0.37) 3. INCLUDES TWO TR20 TAMPER-RESISTANT TORX SCREWS (M4-0.7x16 mm, INSTALLED) AND TWO THUMB SCREWS. FIGURE 10. PMA-60 Panel-Mount Adapter.

Page 14 67.5 (2.657) R1.25(0.049) MAXIMUM 48.0 (1.890) 66.0 (2.598) 67.5 (2.657) NOTES: 1. CONVERSION KIT FOR 0-5 V ANALOG OUTPUT. SEE PGA-0500 DOCUMENTATION. 2. DIMENSIONS IN MILLIMETRES (INCHES). TOP MOUNTING CUTOUT % 60 80 100 NOTE 1 20 40 71.0 (2.795) 65.0 (2.559) 0 PGA-0500 ANALOG % CURRENT METER FRONT FIGURE 11. PGA-0500 Analog Percent Current Meter. SIDE REAR 5. TECHNICAL SPECIFICATIONS Supply: 0U Option... 5 VA, 120 to 240 Vac, (+20, -55%) 50/60 Hz; 2 W, 100 to 240 Vdc, (+20, -25%) 0D Option... 2 W, 12 to 30 Vdc, (+20, -25%) 0T Option... 2 W, 40 to 55 Vdc, (+20, -25%) 03 Option... 2.5 VA, 24 Vac, (+15, -40%), 50/60 Hz Trip-Level Range... 1 to 99% CT-Primary Rating in 1% increments (50 ma to 4.95 A with EFCT-x) Trip-Time Settings... 0.05, 0.10, 0.20, 0.30, 0.40, 0.50, 1.0, 1.5, 2.0, and 2.5 s Accuracies (1) : Trip Level (2)... Largest of 5% of setting or: 1-A input: 1% setting... -10, +15 ma 2-99% setting... 10 ma 5-A and EFCT (4) inputs: 1% setting... -35, +60 ma 2-99% setting... 35 ma Trip Time (3)... 5% of setting (-25, +20 ms minimum) Trip Inhibit: Off... Class I On... Class II Level... 11 x CT-Primary Rating Input: Algorithms... DFT or Peak DFT 3 db Frequency Resp... 32 to 86 Hz Peak 3 db Frequency Resp... 20 to 420 Hz CT... 1- or 5-A Secondary Rating, or EFCT-x CT Detection... Open-Circuit Detection with EFCT-x

Page 15 Thermal Withstand: Continuous... 5 x CT-Secondary Rating 1-Second... 80 x CT-Secondary Rating Burden: 5-A input... < 0.01 1-A input... < 0.05 EFCT input... 2 Analog Output: Range... 0 to 5 Vdc, 5 V = 100% CT Rating Output Impedance... 220 Reset... Front-Panel Button and Remote N.O. Momentary Contact Functional Test... Front-Panel Button Output Relay: Contact Configuration... Isolated N.O. and N.C. Operating Mode... Fail-Safe or Non-Fail-Safe CSA/UL Contact Rating... 8 A General Use, 250 Vac, 8 A Resistive, 30 Vdc 0.25 HP, 120/240 Vac Supplemental Contact Ratings: Carry Current... 8 A, maximum Break: 30 Vdc... 240 W Resistive, 170 W Inductive (L/R = 7 ms) 120 Vdc... 24 W Resistive, 17 W Inductive (L/R = 7 ms) ac... 2,000 VA Resistive, 875 VA Inductive (PF = 0.4) (Subject to maximums of 8 A and 250 Vac/ 30 Vdc or 200 ma at 120 Vdc) Trip Mode... Latching or Autoreset Terminals... Wire-clamping, 24 to 12 AWG (0.2 to 2.5 mm 2 ) conductors Dimensions: Height... 75 mm (3.0 ) Width... 55 mm (2.2 ) Depth... 113 mm (4.5 ) Environment: Operating Temperature: Altitude: 1,000 m (3,281 )... -40 to 60 C (-40 to 140 F) 3,000 m (9,843 )... -40 to 55 C (-40 to 131 F) 5,000 m (16,404 )... -40 to 50 C (-40 to 122 F) Storage Temperature... -55 to 80 C (-67 to 160 F) Humidity... 85% Non-Condensing Altitude... 5,000 m (16,404 ) maximum PWB Conformal Coating... MIL-1-46058 qualified UL QMJU2 recognized Surge Withstand... ANSI/IEEE 37.90.1-1989 (Oscillatory and Fast Transient) Vibration... EN60255-21-1 (Vibration, Shock, and Seismic) EN60255-21-2 (Shock and Bump) EMC Tests: Verification tested in accordance with EN 50263:2000 Radiated and Conducted Emissions... CISPR 11:2009, CISPR 22:2008, EN55022:2010 Class A Current Harmonics and Voltage Fluctuation... IEC 61000-3-2 and IEC 61000-3-3 Class A Electrostatic Discharge... IEC 61000-4-2 ± 6 kv contact discharge (direct and indirect) ± 8 kv air discharge Radiated RF Immunity... IEC 61000-4-3 10 V/m, 80-1000 MHz, 80% AM (1 khz) 10 V/m, 900 MHz, 200 Hz pulse modulated Shipping Weight... 0.45 kg (1 lb)

Page 16 Fast Transient... IEC 61000-4-4 4 kv on AC mains and I/O lines Surge Immunity... IEC 61000-4-5 Zone B ± 1 kv differential mode ± 2 kv common mode Conducted RF Immunity... IEC 61000-4-6 10 V, 0.15-80 MHz, 80% AM (1 khz) Magnetic Field Immunity... IEC 61000-4-8 50 Hz and 60 Hz, 30 A/m and 300 A/m Voltage Interruption... IEC 61000-4-11, IEC 61000-4-29, 0% for 5, 10, 20, 50, 100 & 200 ms 3x each Power Frequency... IEC 61000-4-16 Zone A: differential mode 150 Vrms Zone A: common mode 300 Vrms 1 MHz Burst... IEC 61000-4-18 ± 1 kv differential mode (line-to-line) ± 2.5 kv common mode RFI Compliance... FCC Part 15, Subpart B, Class A Unintentional Radiators Certification... CSA, Canada and USA R LR 53428 C US UL Listed Australia N11659 FCC CE, European Union Complies to IEC 61010-1:2001 (2 nd Edition); EN 61010-1:2001 (2 nd Edition) Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use Part 1. NOTES: (1) Over operating temperature range of -40 to 60 C (-40 to 140 F). (2) CT accuracy not included. (3) Trip time at 3 x trip-level setting from the first peak. (4) For maximum lead resistance of 1. 6. ORDERING INFORMATION SE-701-0 - Conformal Coating: Blank Partial Conformal Coating CC Full Conformal Coating Supply: 3 24-Vac Supply U Universal 120/240-Vac/Vdc Supply D 12/24-Vdc Supply T 48-Vdc Supply EFCT-1... Earth-Fault CT, 5-A-primary rating, 82 mm (3.2 ) window EFCT-1FC... Flux Conditioner for EFCT-1, 70 mm (2.7 ) window EFCT-2... Earth-Fault CT, with Flux Conditioner, 5-A-primary rating, 139 mm (5.5 ) window EFCT-26... Earth-Fault CT, 5-A-primary rating, 26 mm (1 ) window (All EFCT s include 6 m (19.2 ) 22 AWG (0.3 mm 2 ) shielded cable.)

Page 17 SE-CS30-26... Current Sensor, 26.0 mm (1.02 ) window SE-CS30-70... Current Sensor c/w Flux Conditioner, 69.8 mm (2.75 ) window SE-CS30-4... Current Sensor c/w Flux Conditioner, 95.0 mm (3.74 ) window SE-CS30-5... Current Sensor c/w Flux Conditioner, 130.0 mm (5.12 ) window SE-CS30-8... Current Sensor c/w Flux Conditioner, 200.0 mm (7.87 ) window 5SHT-101-E (1)... Current Sensor, 100-A-primary rating, 40 mm (1.6 ) window 5SHT-151-E (1)... Current Sensor, 150-A-primary rating, 40 mm (1.6 ) window 5SHT-500-E (1)... Current Sensor, 50-A-primary rating, 40 mm (1.6 ) window 7SHT-301-E (1)... Current Sensor, 300-A-primary rating, 64 mm (2.5 ) window 7SHT-401-E (1)... Current Sensor, 400-A-primary rating, 64 mm (2.5 ) window 7. WARRANTY The SE-701 Ground-Fault Monitor is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. Littelfuse Startco will (at Littelfuse Startco s option) repair, replace, or refund the original purchase price of an SE-701 that is determined by Littelfuse Startco to be defective if it is returned to the factory, freight prepaid, within the warranty period. This warranty does not apply to repairs required as a result of misuse, negligence, an accident, improper installation, tampering, or insufficient care. Littelfuse Startco does not warrant products repaired or modified by non- Littelfuse Startco personnel. PGA-0500... Analog Percent Current Meter (PGA-05CV included) PMA-55... Panel-Mount Adapter, NEMA 1 PMA-60... Panel-Mount Adapter, NEMA 3, IP53. Includes two TR20 tamper-resistant Torx screws and two thumb screws. PMA-3... Adapter Plate, GES/MCGG PMA-6... Adapter Plate, FPL-GFRM PMA-15... Adapter Plate, MGFR SE-EFVC... Voltage Clamp Consult factory for custom mounting adapters. NOTES: (1) Includes mounting brackets.

Page 18 8. GROUND-FAULT PERFORMANCE TEST To meet the requirements of the National Electrical Code (NEC), as applicable, the overall ground-fault protection system requires a performance test when first installed. A written record of the performance test is to be retained by those in charge of the electrical installation in order to make it available to the authority having jurisdiction. A test-record form is provided for recording the date and the final results of the performance tests. The following ground-fault system tests are to be conducted by qualified personnel: a) Evaluate the interconnected system in accordance with the overall equipment manufacturer s detailed instructions. b) Verify proper location of the ground-fault current sensor. Ensure the cables pass through the groundfault-current-sensor window. This check can be done visually with knowledge of the circuit. The connection of the current-sensor secondary to the SE- 701 is not polarity sensitive. c) Verify that the system is correctly grounded and that alternate ground paths do not exist that bypass the current sensor. High-voltage testers and resistance bridges can be used to determine the existence of alternate ground paths. d) Verify proper reaction of the circuit-interrupting device in response to a simulated or controlled ground-fault current. To simulate ground-fault current, use CT-primary current injection. Fig. 12 (a) shows a test circuit using an SE-400 Ground-Fault- Relay Test Unit. The SE-400 has a programmable output of 0.5 to 9.9 A for a duration of 0.1 to 9.9 seconds. Set the test current to 120% of the SE-701 setting. Fig. 12 (b) shows a test circuit using an SE-100T Ground-Fault-Relay Tester. The SE-100T provides a test current of 0.65 or 2.75 A for testing 0.5- and 2.0-A trip levels. Inject the test current through the current-sensor window for at least 2.5 seconds. Verify that the circuit under test has reacted properly. Correct any problems and re-test until the proper reaction is verified. e) Record the date and the results of the test on the attached test-record form. a) USING SE-400 FROM POWER SOURCE REMOTE TEST b) USING SE-100T FROM POWER SOURCE REMOTE TEST 11 L 10 N 11 3 L N 5 1 8 9 11 L 10 N XXX:5 1 2 3 4 5 1 A 5 A C S1 S2 L1 SE-701 L2/N OP1 L1 L2 RMT1 RMT2 SE-400 XXX:5 OP2 1 2 3 4 5 1 A 5 A C S1 S2 L1 SE-701 L2/N C LO L L1 HI N L2 RMT SE-100T FIGURE 12. Ground-Fault-Test Circuits. 12 LOAD LOAD 0.65 A 2.75 A NOTE: Do not inject test current directly into CT-input terminals 1, 2, 3, 4, and 5.

Page 19 DATE TABLE 2. GROUND-FAULT-TEST RECORD TEST RESULTS Retain this record for the authority having jurisdiction.

Page 20 MANUAL RELEASE DATE July 24, 2014 October 21, 2013 April 12, 2013 MANUAL REVISION 10-C-072414 10-B-102113 10-A-041213 APPENDIX A SE-701 REVISION HISTORY PRODUCT REVISION (REVISION NUMBER ON PRODUCT LABEL) 09 MANUAL REVISION HISTORY REVISION 10-C-072414 SECTION 4 Fig. 8 updated. SECTION 5 Update to include altitude and vibration specifications. APPENDIX A Revision history updated. REVISION 10-B-102113 SECTION 4 Fig. 6 updated to include EFCT-26 and SE-CS30-26. SECTION 5 Conformal coating specifications added. FCC certification mark added. SECTION 6 Updated ordering information with full conformal coating (CC) option. APPENDIX A Revision history updated. REVISION 10-A-041213 SECTION 3 Figs. 2 and 3 updated to include PGA-05CV. SECTION 4 Figs. 7, 8, and 9 added. SECTION 5 Environment section updated to include Fahrenheit temperature range. SECTION 6 Additional current sensors added to ordering information. APPENDIX A Revision history added. PRODUCT REVISION HISTORY REVISION 09 Firmware: Improved operation of front-panel test button.