WORLDWIDE. GW400k SERIES MAINTENANCE MANUAL PROVEN PERIMETER PROTECTION



Similar documents
The Premier Fence Mounted Perimeter Intruder Detection System

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

i ChatterBox! Motorcycle Security

ALARMLINE ANALOGUE Linear Heat Detection System

CX Zoner Installation & User Guide

WD-AMX Water Detection Controllers

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

MSL1000 Monitored Serial Link Interface Manual V1.01

Kit Watt Audio Amplifier

9452/9453 Installation and User Guide

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Fire Alarm Control Panel. Family. Operating Manual

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Advanced Fencing and Security Technologies Ltd

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

LocoNet, the Digitrax Difference

Mobile Device Power Monitor Battery Connection Quick Start Guide

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

CB200W Water Leak Detection Panel Application Guide

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Digital Keypad Use s Manual

Test Before Touch Easier Said Than Done. Ken Crawford, DuPont Kent Haggerty, Dupont

DC Circuits (Combination of resistances)

Modifying the Yaesu FT-847 External MHz Reference Input

SAFETY MANUAL SIL Switch Amplifier

Combi B Alarm box. Mounting instructions

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Section D..General Auto Electrical Corporation

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Shunt lock function 3066

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

SECURITY SYSTEM ADP-CAN

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

What is a multimeter?

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

USER MANUAL V5.0 ST100

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

PowlVac Vacuum Integrity Tester

TS510 & TS500. Installation & User Guide. Compatible Equipment

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Contents. Document information

INSTRUCTIONS FOR USE Pro-Ject Tube Box S

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

FloodlineMulti 4/8/16Zone Leak Detection Systems

Perimeter Security System

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL H2639IP-1

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Series and Parallel Resistive Circuits Physics Lab VIII

Networkfleet 3500 Product Line Installation Guide

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

LOXONE 12 Channel Amplifier

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

EQUIPMENT SPECIFICATIONS

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Part Number:

Fitting/Installation Guide - UNIVERSAL

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Electrical Fundamentals Module 3: Parallel Circuits

DC400 Dispensing Cutoff System

Experiment 8 Series-Parallel Circuits

Operating and Maintenance Instructions MEDIPOINT 125 MEDICAL GAS CENTRAL ALARM

Technical Update TAA.TU Rev. 1

User manual DinaSys DTC/DTS and DTC/DTZ

ACTIVE 5 ENGINEERING MANUAL

T7560A,B,C Digital Wall Module

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

Speech Dialler Engineering Information

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

INTREPID Perimeter Intrusion Detection System

DC LOAD TESTING Gian Trento June 18 th, 2004

TSn SERIES Surge Protective Device

Advantium 2 Plus Alarm

Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI

OPL BASIC. Dosing System for Professional Laundry machines. Contents

3 740 Wrist strap + shoe tester

Installation instructions for Series NRX INCOM communications adapter module

How To Wire Wireline Cable To A Cell Phone (New Zealand)

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

chapter8 Testing and commissioning Unit 2 outcome 2


PRO PLM Installation Instructions

UT202A Operating Manual. Contents

Installation manual. Version

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Transcription:

ORLDIDE G400k SERIES MAINTENANCE MANUAL PROVEN PERIMETER PROTECTION

GEOQUIP LIMITED Kingsfield Industrial Estate, Derby Road irksworth, Matlock, Derbyshire, DE4 4BG Tel : 01629 824891 Fax : 01629 824896 Document Number: QA79 Prepared by: P Cook Revision Number: 2 Date of Issue: 28/9/99 Approved by: P Elliott

All illustrations and sizes shown in this manual are intended as a guide only and do not form any part of any contract between Geoquip Limited and its customers. All specifications and designs shown in this manual are subject to alteration by Geoquip Limited without notice at any time.

CONTENTS Page 1 G400 Series Equipment Testing...1 1.1 General...1 1.2 Frequency Of Testing...1 1.3 Frequency Of Testing - Exceptions... 2 1.4 Test Documentation...2 2 G400k Sensor Testing...3 2.1 Equipment Required:....3 2.2 Preliminary Precautions...3 2.3 Test Procedure...3 2.4 Conclusion Of Testing...6 3 G475 Analyser Test Procedure....8 3.1 Equipment Required:....8 3.2 Preliminary Precautions...8 3.3 Test Procedure...8 4 G400 Series Accessory Testing...14 4.1 Equipment Required:....14 4.2 Preliminary Precautions...14 4.3 General...14 4.4 Test Procedure - GJB... 15 4.5 Test Procedure - GGLK... 16 4.6 Test Procedure - GELT... 16 4.7 Test Procedure - GGBS-A/C... 16 4.8 Test Procedure - GGBS-B/D... 17 5 Test Result Sheets...18

G400 SERIES EQUIPMENT TESTING 1 1G400 1.1 GENERAL SERIES EQUIPMENT TESTING This manual details the procedures for testing and verification of the major components of any security system employing G400 series equipment. The purpose of the manual is to ensure that the component functionality is verified. This manual does not address the requirements of performance testing, since this topic is best carried out by the site user who may have specific performance test criteria to adhere to. Additionally, the need for maintenance of the perimeter barrier and ancillary equipment is not addressed in this manual since this subject is covered in detail in the appropriate installation and operation manuals for the equipment. 1.2 FREQUENCY OF TESTING A fundamental aspect of any test schedule is that the frequency of testing should be appropriate to the degree of wear and tear to which the equipment is subjected. G400 series electronic equipment which has been installed and commissioned in accordance with the manufacturers recommendations must be tested at intervals not exceeding six months. G400 series equipment to which this requirement applies includes the following list: 1. G475 Analysers 2. GJB Junction Boxes 1

G400 SERIES EQUIPMENT TESTING 1 3. GGLK Gate Loop Kits 4. GGBS Gate Bypass Switches G400k Sensor which is installed on structures which may move and flex under conditions of severe weather as well as being exposed to possible damage during attempted intrusions should be subject to testing at intervals not exceeding three months. Provided however that the sensor is inspected regularly for signs of damage and that the sensor installation requirements specified in the appropriate manual have been rigorously adhered to, the test interval may be extended to six months without detriment. 1.3 FREQUENCY OF TESTING - EXCEPTIONS If, during an interval between tests, the system is exposed to unusual or extreme weather conditions, particularly including exposure to lightning strikes within 1 mile of the perimeter structure, additional testing must be implemented to verify the continued functionality of the system. 1.4 TEST DOCUMENTATION To ensure a complete and continuous record of tests is maintained, it is necessary to fully document the results of each test in a logical and ordered fashion. Sample test sheets for each component of the system are provided in Section 5 of this manual. 2

G400k SENSOR TESTING 2 2G400k 2.1 EQUIPMENT SENSOR REQUIRED: TESTING Flat blade terminal screw driver. Flat blade medium screw driver. Digital multimeter. 500 Volt insulation tester. 2.2 PRELIMINARY PRECAUTIONS Prior to conducting any tests on a zone of G400k Sensor, the following precautions should be taken. 1. Advise the site security personnel of the intention to carry out testing since the procedure will cause the analyser to signal continuous alarms when the sensor is disconnected. 2. Ensure that any gates that have a gate bypass switch are switched to SECURE mode of operation so that the tests will apply to the entire zone of sensor. 2.3 TEST PROCEDURE 1. Remove the lid of the analyser housing and fasten down the tamper microswitch with a piece of adhesive tape or a small tiewrap. Identify the sensor terminal block on the analyser PCB i.e. the left hand, four way, block marked J4. See Figure 1. 2. Disconnect the four wires from this terminal block and also the earth wire from the 6mm ground stub 3

G400k SENSOR TESTING 2 on the bottom end of the box. Identify the following colours for each wire: Red Black Yellow Blue Green/yellow 3. Set the multimeter to read resistance on the 200 range. Measure the resistance of the loop formed by the red and yellow wires and note the value on the sensor test sheet. 4. ith the multimeter on the same range, measure the resistance of the loop formed by the black and blue wires and note the value on the sensor test sheet. 5. Compare the resistance readings noted in steps 3 and 4 above. In a properly terminated sensor the difference between the two readings should be less than 5%. 6. The sensor length can be estimated from the above resistance readings using the formula shown below. Average loop resistance Length in metres = x 100 16 4

G400k SENSOR TESTING 2 or Length in feet Average loop resistance = x 100 5 N.B. The Loop Resistance must be entered in Ohms. Note the sensor length on the Sensor test sheet. 7. Set the multimeter to the 2k range and measure the resistance value obtained between the red and black wires. Note this value on the sensor test sheet. The value obtained in this step should be 1k plus the reading obtained in either steps 3 or 4 above. 8. Set the multimeter to the 2000k resistance range and check that the resistance between the Green/Yellow earth wire and the Yellow wire is greater than 1M. Note the value obtained on the test sheet. 9. Repeat this test to verify no leakage between the Green/ Yellow wire and the Blue wire, again this reading should be greater than 1M. Note the value obtained on the test sheet. 10.Using the 500 volt insulation tester, verify that any leakage between the green/yellow wire and the metallic structure of the fence exceeds 5M. Note the value obtained on the sensor test sheet. 11.At the end of line termination box disconnect the red and the yellow/green wires from the terminal 5

G400k SENSOR TESTING 2 block and short together. Set the multimeter to the 200 range and check the resistance between the red and the yellow/green wires at the analyser. The resistance obtained should be 21.2 for every 100m of sensor using the length calculated in step 6. After testing reconnect the wires to the end-ofline terminal block. If proceeding to test the analyser as detailed in the next section leave the sensor disconnected from the analyser terminal block. If analyser testing is not to be done at this stage reconnect the sensor tails to the terminal block/ground stud in the analyser ensuring that the colour of the wires match the colours printed on the PCB. Remove the restraint from the tamper microswitch. Verify that on depressing the microswitch, after a short period of time, both Alarm and Tamper LEDs turn on. Replace the analyser lid. 2.4 CONCLUSION OF TESTING On completion of the testing phase, a comparison can be made between the results obtained during the tests with those obtained on the previous tests or during the commissioning procedure for the system. In general, it can be assumed that if resistance readings are lower than previously noted, or if the levels fluctuate significantly depending on the weather conditions at the time of the test, moisture has penetrated the sensor and is affecting the values obtained. 6

G400k SENSOR TESTING 2 If this is found to be the case, corrective actions as detailed in the fault finding section of the installation manual is required. 7

G475 ANALYSER TEST PROCEDURE 3 3G475 3.1 EQUIPMENT ANALYSER REQUIRED: TEST PROCEDURE Digital Multimeter. Flat blade medium screw driver. Flat blade terminal screw driver. Two wire links and a 1k resistor. GAMP-1 audio amplifier. 3.2 PRELIMINARY PRECAUTIONS 1. Advise site security personnel of the intention to carry out testing of the G475 analyser since the procedure will require disconnection from the annunciator system with subsequent alarm indication. 2. If not already done so following sensor testing, remove the lid of the analyser housing and fasten down the tamper microswitch with a piece of adhesive tape or a small tiewrap. 3. Note the settings of the analyser control switches. 3.3 TEST PROCEDURE 1. Set the switches to the following positions: CH.A. sensitivity = 5 CH.B. sensitivity = 5 EVENTS control = 1 TIMER control = 1 8

G475 ANALYSER TEST PROCEDURE 3 Relay Status LEDs Terminal Blocks Figure 1 2. If not already done so, remove the sensor from the analyser PCB by disconnecting the four wires from the left hand, four way terminal block labelled J4 9

G475 ANALYSER TEST PROCEDURE 3 and also the earth wire from the 6mm ground stub on the bottom end of the box. See Figure 1. 3. Install a wire link between positions 1 and 3 of the sensor terminal block. 4. Install the other wire link between positions 2 and 4 of the sensor terminal block. Ensure that the two links do not touch each other. 5. Install the 1k resistor between positions 1 and 2 of the sensor terminal block. See Figure 2. Sensor Terminal Block 1k Resistor Figure 2 6. Set the multimeter to the 20V dc range and measure the dc supply voltage to the analyser PCB. The power terminal block is the only three way block on the PCB and the power input is connected to the two left hand terminals of this. The middle terminal should be +12 V while left hand one should be 0V (zero). The dc supply voltage should be within the range 10.8-13.2 V dc. Note the value obtained on the analyser test sheet. 10

G475 ANALYSER TEST PROCEDURE 3 7. Disconnect the wire from middle terminal (+12V) and ensure that it does not come into contact with the metalwork of the case or any other wires. 8. Set the multimeter to read dc current on the 200mA range. 9. Connect the positive terminal of the multimeter to the wire removed in step 7 previously and the negative terminal of the multimeter to the middle terminal of the power terminal block. The normal current consumption of the G475 analyser should be 100mA ± 10%. Note the reading obtained on the analyser test sheet. Reconnect the +12V wire to the middle terminal of the power terminal block. 10.Verify that both the Alrm and the Tamp LEDs are illuminated. Note this fact on the analyser test sheet. 11.Identify the relay output terminal block i.e. the four way block labelled J5. Set the multimeter to the 200 resistance range and verify that both the Alarm and the Tamper relays are in the closed state by measuring the resistance reading between the two left hand terminals (Alarm relay) and the two right hand terminals (Tamper relay). In both cases the resistance readings should be virtually 0 (zero). Note these facts on the analyser test sheet. 12.Set the Events control to position 0 (zero). Verify that the Alarm relay contacts open by measuring the resistance between the alarm relay terminals. 11

G475 ANALYSER TEST PROCEDURE 3 Note this fact on the analyser test sheet and re-set the Events control switch to position 1. 13.Remove the fastening on the tamper switch on the analyser PCB and release the switch lever. Note that the Tamper relay contacts open by measuring the resistance between the tamper relay terminals. Note this fact on the analyser test sheet and then replace the tamper switch fastening. 14.Disconnect one end of either of the two jumper links installed in steps 3 or 4. Again verify that the Tamper relay operates by following the procedure detailed in the previous step. Replace the jumper link and note this fact on the analyser test sheet. 15.Temporarily short-circuit the 1k resister and verify that the Tamper relay operates by measuring the resistance reading as described before. Note this fact on the analyser test sheet. Remove the short circuit. 16.Set the multimeter to the 20V dc range and measure the dc voltage between the two left hand terminals of the sensor terminal block. This voltage should be 2.4V dc ± 10%. Note the reading on the analyser test sheet. 17.Using the GAMP-1 connected to two way audio terminal block, monitor the audio output of the analyser and verify that the output is quiet and exhibits no spurious tones or other noises. Note this fact on the analyser test sheet. Leave the GAMP-1 connected at this stage. 12

G475 ANALYSER TEST PROCEDURE 3 18.Operate the analyser self-test facility by connecting a jumper link between the two outside terminals of the power terminal block. Observe the Alarm relay LED and note that it turns off after one short burst of audio has sounded through the GAMP-1 amplifier unit. 19.Return the analyser control switch settings to the positions noted earlier. 20.Remove the wire links and resistor from the sensor input and also the self-test wire link. Reconnect the sensor tails to the sensor terminal block/ground stud in the analyser ensuring that the colour of the wires match the colours printed on the PCB. Remove the restraint from the tamper microswitch. Verify that on depressing the microswitch, after a short period of time, both Alarm and Tamper LEDs turn on. Replace the analyser lid. This concludes the analyser test procedure. Should any of the measured values or observed conditions be significantly different to those recorded previously, contact Geoquip Limited for further advice. 13

G400 SERIES ACCESSORY TESTING 4 4G400 4.1 EQUIPMENT SERIES ACCESSORY REQUIRED: TESTING Flat blade terminal screw driver. Flat blade medium screw driver. Digital Multimeter. 4.2 PRELIMINARY PRECAUTIONS 1. Advise site security personnel of the intention to test these components since the test procedure will require disconnection of the sensor to these units. This will cause the analyser unit on that zone to signal continuous alarm conditions. 2. It is not recommended that these tests be carried out in conditions of inclement weather since such conditions may result in unacceptable levels of moisture entering the enclosures of these units. 4.3 GENERAL The test procedures indicated below are designed simply to test the operation of the tamper microswitches within the boxes of the following units: GJB GGLK GELT GGBS 14

G400 SERIES ACCESSORY TESTING 4 Any other faults which may develop in these units would be shown up by the procedures outlined for testing the sensor. 4.4 TEST PROCEDURE - GJB 1. Remove the lid of the box and remove both sensor tails connected to the Red terminals of the terminal blocks within the unit. 2. Fasten down the tamper microswitch with adhesive tape or similar fixing. 3. Set the multimeter to the 200 range and verify that the resistance reading obtained when measuring between the RED terminals is virtually 0 (zero). Note this result on the test sheet. 4. Remove the adhesive tape from the tamper microswitch and release the microswitch lever. Verify that the multimeter indicates an open-circuit condition. Operate the tamper microswitch lever at least five or six times and verify that the multimeter reading changes from an open-circuit condition to a short-circuit condition. Note the results on the test sheet. 5. Reconnect the Red conductors from the sensor back into the junction box terminals and replace the lid of the unit securely. 15

G400 SERIES ACCESSORY TESTING 4 4.5 TEST PROCEDURE - GGLK The tests to be carried out on the GGLK boxes are identical to those listed for the GJB unit described previously. Each box is to be tested individually in accordance with the previous set of instructions and the results noted on the appropriate test sheet. 4.6 TEST PROCEDURE - GELT 1. Remove the lid of the unit and disconnect the sensor cable wires from the terminal block. 2. Set the multimeter to the 2k range and attach the test leads of the multimeter to the Red and Blue terminals of the unit. 3. Note that initially, the meter reads an open-circuit condition, and then depress the microswitch lever. Note that the reading on the multimeter changes to 1k. Record this result on the test sheet. 4. Reconnect the sensor cable leads to the terminal block and replace the lid of the unit. 4.7 TEST PROCEDURE - GGBS-A/C 1. Remove the lid of the unit and disconnect the Blue wires connected to the terminal blocks marked "To Processor" and "To End Of Line". 2. Set the multimeter to the 200 range and connect the test leads to each of the Blue terminals from which the sensor cable wires have been removed. Note that initially, the multimeter reads an open- 16

G400 SERIES ACCESSORY TESTING 4 circuit condition, and then depress the microswitch lever. Note that the reading changes from an opencircuit condition to a virtual short-circuit condition. Note this result on the test sheet. 4.8 TEST PROCEDURE - GGBS -B/D 1. Remove the lid of the unit and disconnect the Red wires connected to the terminal blocks marked "To Processor" and "To End Of Line". 2. Set the multimeter to the 200 range and connect the test leads to each of the Red terminals from which the sensor cable wires have been removed. Note that initially, the multimeter reads an opencircuit condition, and then depress the microswitch lever. Note that the reading changes from an opencircuit condition to a virtual short-circuit condition. Note this result on the test sheet. 17

TEST RESULT SHEETS 5 Date of test: Tested by: Sensor Cable Test Sheet Test Results Sheet No: Signed: Resistance between Red and Yellow wires: Resistance between Black and Blue wires: Loop resistances of tests 1 and 2 within limits (ie ± 5%) Cable length: Resistance between Red and Black wires: Resistance between Green/Yellow and Yellow wires: (>1M) Resistance between Green/Yellow and Blue wires: (>1M) Resistance between Red and Yellow/Green wires: Leakage value between fence and Green/Yellow wire: (>5M) Y/N m M M M 5TEST RESULT SHEETS 18

TEST RESULT SHEETS 5 G475 Analyser Test Sheet Date of test: Sheet No: Tested by: Signed: Test Results Initial Control Settings Channel A: Channel B: Events: Timer: dc Supply voltage (10.2-13.8V dc) dc Supply current (100mA ±10%) 'Alrm' and 'Tamp' LEDs on? 'Alarm' relay contact resistance Terminals 6 and 7 'Tamper' relay contact resistance Terminals 8 and 9 'Alarm' relay opens? Terminals 6 and 7 (Test 12) 'Tamper' relay opens? Terminals 8 and 9 (Test 13) 'Tamper' relay opens? Terminals 8 and 9 (Test 14) 'Tamper' relay opens? Terminals 8 and 9 (Test 15) dc voltage level Terminals 1 and 2 (2.4V dc ± 10%) Audio output clear? (Test 17) Self-test operational? (Test 18) V ma Y/N Y/N Y/N Y/N Y/N V Y/N Y/N 19

TEST RESULT SHEETS 5 G400 Series Accessory Test Sheet Date of test: Sheet No: Tested by: Signed: Test Results GJB Resistance between red terminals (Microswitch down) : Resistance between red terminals (Microswitch up) : GGLK Resistance between red terminals - Box 1 (Microswitch down) : Resistance between red terminals - Box 1 (Microswitch up) : Resistance between red terminals - Box 2 (Microswitch down) : Resistance between red terminals - Box 2 (Microswitch up) : GELT Resistance between red and blue terminals (Microswitch up) : Resistance between red and blue terminals (Microswitch down) : GGBS (terminal colour depends on switch type) Resistance between blue/red terminals (Microswitch up) : Resistance between blue/red terminals (Microswitch down) : 20

TEST RESULT SHEETS 5 21