NG360 Inclinometer with digital RS485 communications port and 360 degree measuring range



Similar documents
An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Temp. & humidity Transmitter Instructions

WEB log. Device connection plans

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

1. SAFETY INFORMATION

Instruction Manual Service Program ULTRA-PROG-IR

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Application/Connection Examples

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Inwall 4 Input / 4 Output Module

Single channel data transceiver module WIZ2-434

Instruction Manual. Monitor Software for Inclinometer V 3.5

Electronic Pressure Switch EDS 300

Software User Guide UG-461

Wind Sensor W-RS485 with RS485 Interface

Vicon Flash Upgrade Software

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Electronic Pressure Switch EDS 3000

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

User manual Compact Web PLC WP240 series IEC-line

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Sensing element Polymer humidity capacitor Operating range humidity 0-100%RH; temperature -40~80Celsius Accuracy

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Digital Single Axis Controller

MANUAL FOR RX700 LR and NR

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Vehicle data acquisition using CAN By Henning Olsson, OptimumG

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Vibration Monitoring System Adash 3600

ABSOLUTE ROTARY ENCODER ETHERNET/IP

Contents. Document information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Security & Chip Card ICs SLE 44R35S / Mifare

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Why you need to monitor serial communication?

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Series 6000 Torque measured metal bellow coupling

Digital-output relative humidity & temperature sensor/module DHT22 (DHT22 also named as AM2302)

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Vicon Flash Upgrade Software

A RF18 Remote control receiver MODULE

Documentation. M-Bus 130-mbx

API Marine. BMS Presentation. Ballast Measurement Systems

PCS0100en Persy Control Services B.V. Netherlands

Combi switchbox with integrated 3/2 way pilot valve

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Duct Humidity Transmitter

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

Belimo Gateway MP to Modbus RTU - UK24MOD

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

WEB log. Device connection plans

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

ABB i-bus EIB Logic Module LM/S 1.1

Technical Information POWER PLANT CONTROLLER

is then retained absolutely without interruption.

User manual Rev. 1.2 (17/04/2015)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

EVAL-UFDC-1/UFDC-1M-16

T0118 T2118 T3118. Instruction Manual

MicroMag3 3-Axis Magnetic Sensor Module

User Manual Software for DSL Digital Speed Switch

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Keep it Simple Timing

Impedance 50 (75 connectors via adapters)

EDI Distributor Control Interface Wiring and Setup Instructions

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Proximity Switches RS (Reed Switch)

SERIAL INTERFACE. Series SSW-03 and 04

Instruction Manual. T3111 T3111L T3111P T3111Ex

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

Inwall Room Temperature Unit

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

RS - SPM. Serial parallel translator module

PLCM-T1 / PLCM-T2 Torch height controller

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

DS Wire Digital Thermometer and Thermostat

1 Technical Description Lokal-200PC

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Transcription:

Inclinometer with digital RS485 communications port and 360 degree measuring range Features integrated 16bit microprocessor RS485 bus output signal no measuring range limitation 0.01 degree resolution minimal linearity deviation high long-term stability hysteresis free output signal minimal zero point drift no interference by ambient electromagnetic fields shockproof as without moving mechanical parts hermetically sealed sensor electrically isolated from point of measurement - no ground connection zero point adjustable through 360 using clamping ring integrated temperature measurements rectify any temperature related measuring inaccuracies Description The is a capacitive, liquid based inclinometer with integrated sensor electronics and 16 bit microprocessor. The measurement result is transmitted via a RS485 port for further processing. Up to 78 sensors can be operated using a single communications line. The measurement method provides a linear relationship between the angle to be measured and the output signal. The determined angle is independent of the local gravitational acceleration, that means that no matter where the measurement is being taken, whether in Europe, Australia, on Mount Everest or on the moon, the inclination will be measured correctly anywhere. Temperature related inaccuracies are corrected by the integrated microprocessor. Application The inclinometer is suitable for applications requiring the measurement of any angle for further processing on a PC. Typical areas of application include construction, mining, vehicles, aircraft, ships, surveying equipment, and transportation and conveyor systems. Technical Specifications Measuring range Resolution Dimensions Linearity deviation Transverse sensitivity Settling time 360 degrees 0.01 degrees see dimension drawing ±0.25 degrees < ±0.1 degree at 45 tilt approx. 0.3 seconds 1 / 6

Supply voltage U bn Supply voltage on-transition time Current drawn Degree of protection Operating temperature Storage temperature Weight (without clamping ring or cable) Electrical connection 9V... 15V < 50ms approx. 40mA IP65-40 bis +85 C -45 bis +90 C approx. 110 grams 1m shielded cable Ø 4.6 mm sensor connection to RS485 bus PC RS232 + - B RS485 A Sensor #00 or 01...78 One sensor connected to bus can be addressed with either 177 (=hb1; #00) or the individual sensor number 110 Ohm terminator internal or external Single sensor Sensor #01 Sensor #02 Sensor #03 Sensor #78 178 (hb2) 179 (hb3) 180 (hb4) 255 (hff) PC RS232 + - B RS485 A Multiple sensors on one bus up to 78 sensors on one bus cable lengths up to 4 km Do not use address 177 (hb1; #00)! All sensors reply to 177 -> data jamming on bus! Terminators must be at the end of cable! 110 Ohm terminator Connection to SEIKA RS232/RS485 converter SC485B WINDOWS - PC Programs COM GetAngle.exe Setup.exe Scan.exe Example.exe 9 8 7 6 5 4 3 2 1 RS232 (half dublex) 9 polar RE Data > Data < SC485B + - +9...+15 Volt GND (-) brown: +9... +15 Volt DC shield = GND green: RS485 -B white: RS485 -A Terminator solderprigde RS232 / RS485 (RS422) Converter Power supply Cable (SB360) (XB360) Sensor 2 / 6

Dimensions (in mm) Measurement angle - + R mounting ring: stainless steel Reinforced glassfiber isolated housing Adjust zero offset by turning housing and fixing with the aluminium ring Cable ø54.8 ø48.8 NG 543210UI Ser.N. 21.6 1.5 Inclinometer serial number 2x ø4.3 58.0 67 Data transmission protocol of measured angle Step PC transmits Sensor transmits 1. Adress (e.g. B1 or B2 or B3...) 2. ENQ (05h) 3. 15ms pause (switching from receive to transmit in sensor) 4. STX (02h) e.g.: 359.99 (angle in ASCII code) ETB (17h) 5. Checksum (2 Byte ASCII code) $ (24h) The checksum is the XOR combination of the sensor output in step 4 (e.g. 02h XOR 359.99 XOR 17h) 6. 15ms pause (switching from transmit to receive in sensor) 7. ACK (06h) if checksum is correct NAK (15h) if checksum is wrong 8. If ACK, terminate If NAK, return to 3. PC COM port settings for the RS232/RS485 converter Bit/Sec 9600 Data bit 8 Parity none Stop bit 1 Protocol none 3 / 6

Software (WINDOWS 98, WINDOWS XP) To display the measurement results and configure the sensor the following programs are used. These programs require a PC running Windows 95/98 or Windows XP. Although the will operate from any half-duplex RS485 port, we recommend using the SEIKA interface converter SC485B. programs should be copied to the hard disk before running them! The programs can be downloaded at http://www.seika.de English language or http://www.seika.net English language. GetAngle.exe This program displays the angle of one or more, which are connected through a RS232/RS485-Converter (i.e. SEIKA SC485B) to the PC. The serial port COM.., the sensor address and the display speed (averaging of several measurements) can be adjusted. Additionaly, measurements can be saved to a logfile in regular time-intervals, for further processing i.e. with MS Excel. If more than one sensor is connected to the same bus, the address 177 (hb1) #00 (as in the figure above) must not be used!!! Since they always respond to the base address 177 (hb1), all the sensors would then answer simultaneously, inevitably causing jamming on the data bus and preventing the transfer of useful information. Nevertheless, the address 177 (hb1) may be used if only one sensor is active. Setup.exe This program can be used to change several parameters of the. These parameters can be read, modified and then saved permanently in the EEPROM. This does not affect any calibration values. Attention! If more then one are configured to use the same address, this inevitably leads to a bus conflict and may damage the bus-driver IC! Reprogramming of the addresses will then only be possible, if every but one sensor on the bus is switched off. Every sensor responds to the address 177 (hb1), and therefore no sensor should be programmed to use this address. Addressing a individually on a bus with multiple active s is impossible after writing address 177 (hb1) to it. As all sensors always respond to the base address 177 (hb1), the transmitted data would be stored in all sensors, deleting any previous settings, in particular the individual addresses. The latter would then have to be reprogrammed. If only one sensor is active, then the address 177 (hb1) can be used, necessary if the sensor's individual address isn't known or hasn't been assigned yet. 4 / 6

After that, invoking "read variables" returns the desired sensor's current configuration and displays the values in the corresponding boxes. After selecting the values for the sensor variables V024, V025, V026 and V063 from their menus, clicking "write variables" permanently writes them to the addressed sensor's EEPROM. The variable V064 (delay for serial port) determines the time period between the data bytes sent by the sensor. The standard setting is 500 and the value may be increased to ensure reliable data transfer for slow PC serial ports. For applications requiring fast measurements, the signal filtering may be turned off by setting V025 (order of the filter) to 0 (no filter). However, these measurements tend to be more unstable. Slow measurements using a 2nd order filter with a low cut-off frequency (V026) display more stable measurement results. Only one program (GetAngle.exe or Setup.exe) may access the serial port at any one time, although more than one may be running simultaneously. Any program using the above communication protocol will work with the sensors. Scan.exe You can use this program to identify every sensor connected to a serial PC COM port through a RS232/RS485-Converter. The program scans the whole range of possible addresses and displays the angle values send by each connected sensor. Invoking "Scan" makes the program request a reading from each of the possible 78 addresses and wait for a response. Should a sensor respond, then the received angle measurement is displayed above the address. After completing the scan, all active sensors can be determined by inspection. Clicking the "Start reading" button causes the program to continually request and display the current angle for every active sensor connected to the bus until terminated by clicking "Stop reading". 5 / 6

Example.exe This directory contains an example program for programmers, with complete MS Visual C++ sourcecode. This open source example program developed using MS Visual C++ 5.0 provides some information how to develop interface software for the RS232/RS485 converter and the sensors. Hardware-RESET Upon activation of the supply voltage, the inclinometer is forced into a predefined operating state by a RESET. This procedure is important for a correct functionality of the internal microprocessor. The supply voltage rise time must be as short as possible for the RESET to be successful. A slow supply voltage rise time or switching the sensor on, off and on again in quick succession (bouncing) can cause the programs running on the internal microprocessor to crash, giving the impression of a defective sensor. Switching the supply voltage on correctly will start the sensor up again correctly. Similar problems can occur if the supply voltage falls below 9V or fluctuates around 9V. The operational time for a correct supply voltage is unlimited. 6 / 6