03/05/14 REVISOR RSI/JC RD3945



Similar documents
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

Underwriters Laboratories Testing Information

ASTM Volume 04.06, November 2015 Thermal Insulation; Building and Environmental Acoustics

Housing Fact Sheets. Insulation Check-Up

Signs of insulation problems In the winter. In the summer. conditioning system

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Fiberglas, Exterior Wall Thermal Insulation

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Continuous Insulation Using Polyiso Wall Sheathing

Introduction to Energy Performance of Brick Masonry

Fire Testing of Recycled Materials for Building Applications

Whether your pocketbook

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

EcoTouch Insulation with PureFiber Technology

Roof Insulation Building. Energy. Environment friendly e-library

) and air spaces (R a

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

COMMERCIAL BUILDING APPLICATIONS

2.1 DEFINITION OF INSULATION GENERIC TYPES AND FORMS OF INSULATION PROPERTIES OF INSULATION MAJOR INSULATION MATERIALS 4

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Building Envelope. Overview

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Open-cell spray foam & what every contractor

Scheme rules for thermal insulation products for building equipment and industrial installations - VDI certification scheme

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

ROCK WOOL Preformed Pipe Section

Insulating Basements: Part 3 Basement Wall Systems

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

CHAPTER 7: Building Systems ROOFING SYSTEMS

ROXUL TOPROCK DD & MONOBOARD. Roofing Insulation for Commercial Construction. ROXUL TOPROCK DD and MONOBOARD

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

Meeting the Fire Code with Continuous Foam Plastic Insulation

Performance of 8 Passive House Envelopes in Cold Climates

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Polyurethane Products

Roof insulations must perform the basic function of helping to control fluctuations in building interior temperature

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

SECTION FIBERGLASS INSULATION

also in this issue Automatic Doors for the People Calculating Roof Insulation R-values Waterproofing and Concrete Balconies

Measure Guideline: Basement Insulation Basics

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

TECH BULLETIN. Roofing No. Impact of Temperature on Polyiso R-value. Subject: Impact of Temperature on the R-value for Polyisocyanurate Insulation

SD-0150 GENERAL PURPOSE ABS (Acrylonitrile Butadiene Styrene) (TA)

TABLE OF CONTENT

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

Post-insulation of cellar ceiling and cellar walls

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

SANDWICH PANEL FILLING MATERIALS

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

Insulation R-Value Comparisons

Building Envelope Design. ComfortBoard IS. Exterior Insulated Sheathing for High-Performance Residential Wall Systems

Tsawwassen BC Arena Before & After installation of the Low-E ceiling

TECHNICAL BULLETIN

Insulation Technologies and Materials Technologies, Systems and Tools in the U.S.

ROOFS, SNOW AND ICE DAMS

Testing Rules for Thermal Conductivity October 2015

POLYURETHANE FOAM CONCEPT

OUTSTANDING CHARACTERISTICS OF TEKFOIL HI-PERFORMANCE REFLECTIVE INSULATION

Insulation Products For Residential Thermal Applications ROXUL. Better Best ROXUL. Solutions For Residential Thermal Applications.

Residential Windows, 3 rd edition Corrected index 1

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

First Time Home Buyers Energy Efficiency Workshop Guide

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Back to the drawing board

United States. Why You Should Insulate Foundations. There is a science to adding value.

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

EXPANDED POLYSTYRENE FOR. ResidentialBuilding Applications

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Physically Crosslinked Foam Insulation

Renovating Your Basement

The Optimum Basement Wall

Best Practices for Crawl Space Insulation

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

Monitored Field Performance of Conventional Roofing Assemblies Measuring the Benefits of Insulation Strategy


Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

PIMA Technical Bulletin #115. The High R Roof: Guidelines for Energy-Efficient Roofing and Re-Roofing. What is a High R Roof?

BUILDING ENERGY NEEDS with particular attention paid to THERMAL INSULATION

Compliance Software COMcheck 2 and ENVSTD 3

What s Wrong with this Project? Report

Process Plant Insulation & Fuel Efficiency

Technical Specification Fire Blanket Firemaster Fire Protection-Cables Tray Fire Protection Department

Waterproofing and interior insulation for basements takes new twist in technology.

Since the first known building

Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls

Contract for Weatherization Management Address City & State

The Myth of Vapor Permeation and Thermal Insulation

Mold Preventing I nterior System

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Transcription:

1.1 Department of Commerce 1.2 Proposed Permanent Rules Relating to Commerce; Thermal Insulation Standards; 1.3 Materials and Installation 1.4 7640.0100 AUTHORITY; PURPOSE; INCORPORATIONS BY REFERENCE. 1.5 [For text of subps 1 and 2, see M.R.] 1.6 Subp. 3. Incorporations by reference. This chapter incorporates numerous standards 1.7 by reference that are published by ASTM, Conshohocken, Pennsylvania. This chapter also 1.8 incorporates an ANSI/ISO/ASQ standard by reference, published by the American Society 1.9 for Quality, Milwaukee, Wisconsin. This chapter also incorporates an ICC-Evaluation 1.10 Services standard by reference, published by the ICC-Evaluation Service, Whittier, 1.11 California. This chapter also incorporates an ASHRAE standard by reference, published 1.12 by ASHRAE, Atlanta, Georgia. The standards and tests incorporated by reference are all 1.13 an integral part of current insulation industry testing procedures. All manufacturers and 1.14 testing laboratories presently possess or have access to each referenced incorporation. 1.15 All of the incorporated standards are subject to frequent change. Copies of all 1.16 standards incorporated by reference are available in the Office of the Commissioner of 1.17 Commerce and through interlibrary loan from the Minnesota State Law Library. 1.18 7640.0110 APPLICABILITY AND CONDUCT. 1.19 [For text of subp 1, see M.R.] 1.20 Subp. 2. Conduct. 1.21 [For text of items A to E, see M.R.] 1.22 F. If any representation is made that a product to be installed in Minnesota 1.23 residential buildings will affect heat flow or energy savings, the representation must be 1.24 based on the building envelope climate criteria for Minnesota as set forth in the American 7640.0110 1

2.1 Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Standard 2.2 90.1-2010. 2.3 [For text of subps 3 to 5, see M.R.] 2.4 7640.0120 DEFINITIONS. 2.5 Subpart 1. Applicability. For the purposes of this chapter, the following definitions 2.6 of terms apply. Technical, scientific, and engineering terms undefined by this part have the 2.7 meanings given in ASTM C168-05a C168-13, Standard Definitions of Terms Relating 2.8 to Thermal Insulation Materials. 2.9 [For text of subps 2 to 26, see M.R.] 2.10 7640.0130 STANDARDS FOR INSULATION MATERIALS AND INSTALLATION. 2.11 [For text of subps 1 and 2, see M.R.] 2.12 Subp. 3. Cellulose insulation. 2.13 [For text of item A, see M.R.] 2.14 B. Cellulose fiber in loose-fill form must comply with ASTM C739-05be1 2.15 C739-11, Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation. 2.16 Cellulose loose-fill insulation must be installed in accordance with ASTM 2.17 C1015-06(2011)e1, Standard Practice for Installation of Cellulosic and Mineral Fiber 2.18 Loose-Fill Thermal Insulation. 2.19 C. Cellulose fiber spray-applied must comply with either: 2.20 (1) Type II requirements of ASTM C1149-06e1 C1149-11, Standard 2.21 Specification for Self-Supported Spray Applied Cellulosic Thermal Insulation; or. 2.22 (2) ASTM C739-05be1, Standard Specification for Cellulosic Fiber 2.23 Loose-Fill Thermal Insulation. Design density and thermal resistance must be determined 7640.0130 2

3.1 for specimens prepared as spray-applied according to manufacturer's installation 3.2 instructions. 3.3 D. Cellulose fiber stabilized must comply with this item. 3.4 (1) Thermal performance, shrinkage, and settling must be determined 3.5 by sections 5.8, 5.10, and 5.11, respectively of ASTM C1497-04 C1497-12, Standard 3.6 Specification for Cellulosic Fiber Stabilized Thermal Insulation. 3.7 (2) Corrosiveness, critical radiant flux, fungi resistance, water vapor 3.8 sorption, odor emission, and smoldering combustion must be determined by the 3.9 appropriate sections of either ASTM C1497-04 or ASTM C739-05be1. 3.10 E. Cellulosic fiber insulating board must comply with ASTM C208-12, 3.11 Standard Specification for Cellulosic Fiber Insulating Board. 3.12 E. F. Industry members and other persons may not engage in the mobile 3.13 manufacture of cellulose insulation, which means the simultaneous on-site production and 3.14 installation of cellulose insulation as an integral mechanical and manufacturing process. 3.15 Subp. 4. Mineral fiber insulation. 3.16 A. Mineral fiber in loose fill form must comply with ASTM C764-07 C764-11, 3.17 Standard Specification for Mineral Fiber Loose Fill Thermal Insulation. 3.18 (1) Mineral fiber loose fill must achieve not less than stated performance at 3.19 winter design conditions as shown by ASTM C1373-03 C1373/C1373M-11, Standard 3.20 Practice for Determination of Thermal Resistance of Attic Insulation Systems Under 3.21 Simulated Winter Conditions. 3.22 (2) Mineral fiber loose fill must be installed in accordance with ASTM 3.23 C1015-06 C1015-06(2011)e, Standard Practice for Installation of Cellulosic and Mineral 3.24 Fiber Loose-Fill Thermal Insulation. 7640.0130 3

4.1 B. Mineral fiber in batts and blankets form must comply with ASTM C665-06 4.2 C665-12, Standard Specification for Mineral Fiber Blanket Thermal Insulation for Light 4.3 Frame Construction and Manufactured Housing. Mineral fiber in batts and blankets must 4.4 be installed in accordance with ASTM C1320-10, Standard Practice for Installation of 4.5 Mineral Fiber Batt and Blanket Thermal Insulation for Light Frame Construction. 4.6 C. Mineral fiber in board form must comply with ASTM C612-04 C612-10, 4.7 Standard Specification for Mineral Fiber Block and Board Thermal Insulation. 4.8 D. Spray applied mineral fiber must comply with ASTM C1014-03e1 4.9 C1014-08(2013), Standard Specification for Spray Applied Mineral Fiber Thermal or 4.10 Acoustical and Sound Absorbing Insulation. 4.11 Subp. 5. Foam plastic insulation. All foam plastic insulation must achieve stated 4.12 performance at 75 degrees Fahrenheit mean temperature. For foam plastic insulations 4.13 that incorporate blowing agents other than air or pentane, R-value tests must be done on 4.14 specimens that have been treated in accordance with either the test method identified for 4.15 the product in items A to F or the Federal Trade Commission R-Value rule, Code of Federal 4.16 Regulations, title 16, part 460, to fully reflect the effect of aging on the product's R-value. 4.17 A. Rigid, cellular polystyrene insulation must comply with either ASTM 4.18 C578-07 C578-12b, Standard Specification for Rigid, Cellular Polystyrene Thermal 4.19 Insulation, or item F. 4.20 B. Faced polyisocyanurate in board form must comply with either ASTM 4.21 C1289-07 C1289-13e1, Standard Specification for Faced Rigid Cellular Polyisocyanurate 4.22 Thermal Insulation Board, or item F. 4.23 [For text of item C, see M.R.] 7640.0130 4

5.1 D. Spray-applied polyurethane foam must comply with either ASTM 5.2 C1029-05a C1029-13, Standard Specification for Spray Applied Rigid Polyurethane 5.3 Thermal Insulation, or item F. 5.4 E. Rigid cellular phenolic insulation must comply with either ASTM C1126-04 5.5 C1126-13, Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal 5.6 Insulation, or item F. 5.7 [For text of item F, see M.R.] 5.8 Subp. 6. Perlite and vermiculite insulation. 5.9 [For text of item A, see M.R.] 5.10 B. Vermiculite in loose fill form must meet the following requirements: 5.11 (1) The product must comply with ASTM C516-02 C516-08, Standard 5.12 Specification for Vermiculite Loose Fill Thermal Insulation. 5.13 (2) The manufacturer shall disclose to the department any chemical 5.14 treatment of the vermiculite material and the purpose of the treatment. 5.15 Subp. 7. Reflective foil insulation. 5.16 A. Reflective insulation for building applications must meet the requirements 5.17 of either ASTM C1224-03 C1224-11, Standard Specification for Reflective Insulation 5.18 for Building Applications. 5.19 Exception: Products having a current ICC-Evaluation Services Report in accordance 5.20 with, or ICC-AC02, Acceptance Criteria for Reflective Foil Insulation. 5.21 Reflective foil insulation must be installed according to ASTM C727-01(2007)e1 5.22 C727-12, Standard Practice for Installation and Use of Reflective Insulation in Building 5.23 Constructions. 7640.0130 5

6.1 B. Radiant barrier products must meet the requirements of either ASTM 6.2 C1313-05 C1313/C1313M-13, Standard Specification for Sheet Radiant Barriers for 6.3 Building Construction Applications. 6.4 Exception: Products having a current ICC-Evaluation Services Report in accordance 6.5 with, or ICC-EG220, Evaluation Guideline for Sheet Radiant Barriers. Radiant barriers 6.6 must be installed according to ASTM C1158-05, Standard Practice for Installation and 6.7 Use of Radiant Barrier Systems (RBS) in Building Construction. 6.8 Subp. 7a. Cotton fiber insulation products. Cotton fiber insulation products must 6.9 meet the criteria of ICC-EG81, Evaluation Guideline for Cotton Fiber Insulation. 6.10 Subp. 7b. Polyester loose-fill and blanket insulation products. Polyester loose-fill 6.11 and blanket insulation products must meet the criteria of ICC-AC187, Acceptance Criteria 6.12 for Polyester Loose-Fill and Blanket Insulations. 6.13 Subp. 7c. Vacuum insulation panel insulation. Vacuum insulation panel insulation 6.14 must meet the requirements of ASTM C1484-10, Standard Specification for Vacuum 6.15 Insulation Panels. 6.16 Subp. 8. Other insulation. Insulation other than insulation specified in subparts 1 to 6.17 7 7c must comply with the requirements of this subpart. The thermal insulation material 6.18 chosen for testing must be representative of material produced by the manufacturer during 6.19 normal production runs. 6.20 Exceptions: Cotton fiber Insulation products must comply with either items A to G 6.21 or ICC-EG81, Evaluation Guideline for Cotton Fiber Insulation. Polyester loose-fill 6.22 and blanket insulation products must comply with either items A to G or ICC-AC187, 6.23 Acceptance Criteria for Polyester Loose-Fill and Blanket Insulations. 6.24 A. Thermal performance characteristics must be determined in accordance 6.25 with this item. 7640.0130 6

7.1 (1) One of the following test methods must be used: ASTM C177-04 7.2 C177-13, ASTM C518-04 C518-10, ASTM C1199-00 C1199-12, or ASTM C1114-06. 7.3 Manufacturers shall select the appropriate test method for the material unless a specific 7.4 method or procedure is referenced within a materials specification. 7.5 [For text of subitems (2) and (3), see M.R.] 7.6 B. Water or moisture absorption must be determined according to one of the 7.7 following methods: ASTM C272-01 C272/C272M-12; ASTM C553-02 C553-11, section 7.8 14; ASTM C739-05 C739-11, section 12; or ASTM D2842-06 D2842-12. 7.9 C. If the material is foam in place, a test must be conducted to determine the 7.10 response to thermal and humid aging in accordance with ASTM C1029-05 C1029-13, 7.11 section 10.6. 7.12 [For text of item D, see M.R.] 7.13 E. The product must not produce a detectable odor that is classified as 7.14 objectionable and strong or very strong by ASTM C1304-95 (2001) C1304-08, Standard 7.15 Test Method for Assessing the Odor Emission of Thermal Insulation Materials. 7.16 F. Surface burning characteristics must be determined in accordance with 7.17 ASTM E84-07b E84-13a, "Standard Test Method for Surface Burning Characteristics of 7.18 Building Materials," or Underwriters Laboratories Standard UL 723, "Standard for Fire 7.19 Tests of Building Construction and Materials." 7.20 [For text of item G, see M.R.] 7.21 7640.0150 REPORTING REQUIREMENTS. 7.22 Subpart 1. [See repealer.] 7.23 Subp. 2. Initial report Reporting. An industry member shall file an initial report at 7.24 least 30 days before offering for sale in the state any new products, significant changes 7640.0150 7

8.1 to a product already filed, or changes to product installation instructions to a product 8.2 already filed. 8.3 The initial report must include the following: Upon request by the commissioner, 8.4 an industry member who offers for sale in this state any products subject to this part 8.5 shall provide the following information: 8.6 [For text of items A to C, see M.R.] 8.7 D. product literature, including installation instructions and promotional 8.8 materials, a copy of the label affixed to the product, a copy of the product's material safety 8.9 data sheet, and a list of the intended uses of the product, including whether the product is 8.10 recommended for exterior below-grade application; 8.11 [For text of items E to I, see M.R.] 8.12 Subp. 3. [See repealer.] 8.13 REPEALER. Minnesota Rules, part 7640.0150, subparts 1 and 3, are repealed. 7640.0150 8