Scheme rules for thermal insulation products for building equipment and industrial installations - VDI certification scheme
|
|
|
- Clemence Anderson
- 10 years ago
- Views:
Transcription
1 Scheme rules for thermal insulation products for building equipment and industrial installations - certification scheme April 6, Introduction This document presents the rules of the product certification scheme "-Mark" for thermal insulation products for building equipment and industrial installations, based on harmonised European product standards. NOTE 1 The attestation of conformity procedures for this quality mark provide product certification related to all the requirements of the standard and to all characteristics (properties) of the product as declared by the manufacturer, complementing the requirements for CE marking. Product audit testing is included. These scheme rules are largely based on the existing Keymark scheme for factory made thermal insulation products for buildings and on the scheme for thermal insulation products intended for industrial installations. NOTE 2 The Keymark scheme for building insulation products was established in 2001 for products according to the product standards EN through EN See the web site for further information NOTE 3 The -Mark has been applied for more than two decades and requires a high quality level for insulation materials for industrial installations in the European market. The quality assurance scheme was established by Verein Deutscher Ingenieure e.v. for thermal insulation products for industrial applications based upon the Guideline The scheme rules are maintained by the -AG "Quality Assurance" ("Gütesicherung") working group. The -AG "Quality Assurance" uses an acknowledged certification body on the basis of a contract for the execution of its resolutions and for organisational support. The -mark does not apply to insulation products used in heating and exhaust equipments in account of national regulations like EnEV (Energy saving regulation) in Germany. In case of certification of products where no European Standard exists, the rules given in appendix H apply. Insulation products carrying the -Mark must have a significantly positive energy balance: This means the reductions in energy used and emissions produced during the service life of an -certified insulation product by far exceed the energy required for and the emissions generated during its production and later disposal. To limit costs and time delay for manufacturers, the product certification scheme is based on the following principles: - Scope: Common technical specifications - Organisation of the body responsible for managing the scheme Quality Assurance Committee, see appendix G - Acceptance of conformity assessment bodies (inspection, testing and certification) - Application procedures - Conformity assessment procedures (inspection, testing and certification) - Fee-system - Website - Rules for handling complaints, disputes and appeals - Right to affix markings
2 - Transitional arrangements 2. Scope The scheme is applicable for products described in the package of product standards for thermal insulation products for building equipment and industrial installations as presented in table 1. These scheme rules specify the basis for the operation of the voluntary product certification scheme for thermal insulation products for building equipment and industrial installations. These scheme rules shall be read in conjunction with the cooperation agreement between CEN and. The technical content of the conformity assessment procedures shall be in accordance with the technical specifications specified in table 1 and with EN and EN ISO 13787, with the additions as defined in these scheme rules. Table 1: Technical specifications covered by these -Mark scheme rules - EN (MW) Thermal insulation products for building equipment and industrial installations - Factory made mineral wool (MW) products Specification - EN (FEF) Thermal insulation products for building equipment and industrial installations - Factory made flexible elastomeric foam (FEF) products Specification - EN (CG) Thermal insulation products for building equipment and industrial installations - Factory made cellular glass (CG) products - Specification - EN (CS) Thermal insulation products for building equipment and industrial installations - Factory made calcium silicate (CS) products Specification - EN (XPS) Thermal insulation products for building equipment and industrial installations - Factory made extruded polystyrene foam (XPS) products - Specification - EN (PUR/PIR) Thermal insulation products for building equipment and industrial installations - Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products Specification - EN (EPS) Thermal insulation products for building equipment and industrial installations - Factory made products of expanded polystyrene (EPS) Specification - EN (PEF) Thermal insulation products for building equipment and industrial installations - Factory made polyethylene foam (PEF) products - Specification - EN (PF) Thermal insulation products for building equipment and industrial installations - Factory made phenolic foam (PF) products - Specification Note: These standards were published November 4, Preferably these scheme rules should be applied in conjunction with the conformity assessment for CE Marking. 2
3 The following product standards may be added later: - pren (PUR) Thermal insulating products for building equipment and industrial installations - In-situ formed dispensed rigid polyurethane foam (PUR) products - Part 1: Specification for the rigid foam dispensed system before installation - pren (PUR) Thermal insulating products for building equipment and industrial installations - In-situ formed sprayed rigid polyurethane foam (PUR) products - Part 1: Specification for the rigid foam spray system before installation - EN (EP) Thermal insulation products for building equipment and industrial installations in situ thermal insulation formed from expanded perlite (EP) products - Part 1: Specification for bonded and loose-fill products before installation - EN (EV) Thermal insulation products for building equipment and industrial installations in situ thermal insulation formed from exfoliated vermiculite (EV) products - Part 1: Specification for bonded and loose-fill products before installation 3. Abbreviations AoC CPD EA Attestation of conformity, with reference to the Construction Products Directive (89/106/EEC) Construction Products Directive (89/106/EEC) European Accreditation 4. References Council Directive of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products (Construction Products Directive), (89/106/EEC), amended by Council Directive 93/68/EEC of 22 July 1993 and Regulation (EC) No 1882/2003 of the European Parliament and of the Council of 29 September 2003 EN 13172, Thermal insulation products Evaluation of conformity 2055, Thermal Insulation for Heated and Refrigerated Industrial and Domestic Installations Calculations, Guarantees, Measuring and testing Methods, Quality Assurance, Supply Conditions (June 1994) EN ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories EN ISO 13787, Thermal insulation products for building equipment and industrial installations - Determination of declared thermal conductivity 3
4 EN 45011, General requirements for bodies operating product certification systems Appendix A, Checklist for inspection bodies for audits in the factory Appendix B, Framework for the activities of registered laboratories for measurements of thermal conductivity curve, maximum service temperature and chloride content. Appendix C, Checklist for auditors Audit visit at candidate registered laboratories Appendix D, Position paper for ITT for CE marking of products (NB-CPD/SG 19) Appendix E, Fee system Appendix F, implementation arrangements Appendix F Annex, Guidance on transitional arrangements for the CE marking (NB-CPD/SG 19) Appendix G, Quality Assurance Mark implementation rules Appendix H, scheme rules for products where no EN standard exist (text to be drafted) (Not related to CEN Keymark) 5. Quality Assurance Committee The Quality Assurance Committee is responsible for the development of the scheme rules and their maintenance, although it is understood that changes of these rules need to be confirmed separately in the two organisations before being applicable. This joint working group shall endeavour to ensure that it is composed of the major actors, with representation from all parties concerned (manufacturers, contractors, users, laboratories, inspection bodies and certification bodies). The scheme shall be managed as specified in Appendix G. 6. Acceptance of conformity assessment bodies 6.1 General requirements The testing laboratories and the inspection and certification bodies shall fulfil the following minimum conditions: - Availability of personnel and of the necessary means and equipment; - Technical competence and professional integrity of personnel; - Impartiality, in carrying out the tests, preparing the reports, issuing the certificates and performing the inspection and surveillance provided for in the scheme rules, of staff and technical personnel in relation to all circles, groups or persons directly or indirectly concerned with the products; - Maintenance of professional secrecy by personnel; - Subscription of a civil liability insurance. 4
5 Representatives of all third parties involved in the scheme shall regularly participate in meetings of the joint working group. Participants shall participate on a regular basis in the coordination activities within the framework of these scheme rules. 6.2 Notification requirements Conformity assessment tasks performed within the framework of compliance with the Construction Products Directive (89/106/EEC - CPD), as amended, will be taken into account in the scheme rules. The product certification scheme for thermal insulation products for building equipment and industrial installations is preferably applied simultaneously with the CE marking to prevent duplication of conformity assessment tasks. Therefore, notification within the framework of the Construction Products Directive, for the relevant technical specifications (see 2) and for the relevant task (see 6.3) is a precondition (as far as required, i.e. only if and where attestation of conformity systems 1 or 3 apply) to becoming recognised in the scheme rules, i.e. for certification bodies and for testing laboratories. 6.3 Requirements for Certification bodies Certification bodies shall be accredited by an EA-member in accordance with EN They are responsible for ensuring sub-contractors competence (inspection body(-ies) 1 and laboratory(-ies)) for the purpose of undertaking inspection and surveillance or testing activities. Certification Bodies shall operate a well-established certification scheme of their own for the products for which they apply. They shall obtain the contractual permission to operate a product certification scheme leading to the authorisation to apply the -Mark. The Quality Assurance secretariat shall be informed of new applications for authorisation and shall have the opportunity to submit observations to the CEN Certification Board. 6.4 Requirements for Inspection bodies Inspection bodies shall comply with the following: - Demonstrated evidence of at least 2 years experience with inspection of manufacturers' facilities producing thermal insulation products for building equipment and industrial installations - Demonstrated competence to inspect and assess manufacturers' compliance with FPC provisions particular to these scheme rules in accordance with Appendix A. 6.5 Requirements for registered testing laboratories In these scheme rules, registered testing laboratories are those which have demonstrated that they are sufficiently competent to examine some or all of the following important performance characteristics (to be listed in the registration): - Thermal conductivity curve - Maximum service temperature - Chloride content 1 Testing laboratories, accredited to EN ISO/IEC are permitted to perform inspection activities as well, if they comply with
6 - water vapour transmission properties, if relevant Laboratories shall be registered for the temperature range for which they prove their testing capability for the thermal conductivity curve (flat and pipe testing) and the maximum service temperature (flat and pipe testing). Having met the registration requirements, the applicant laboratories shall be registered. The registration shall be published on the web site(s) as registered by the scheme web manager. The group of registered testing laboratories will form the European group of reference laboratories active in the scheme. Registered testing laboratories shall be accredited in accordance with EN ISO/IEC and shall comply with the requirements laid down in Appendices B and C. 6.6 Requirements for testing laboratories (other characteristics) Testing laboratories responsible for testing all characteristics except thermal conductivity, maximum service temperature and chloride content, shall be accredited in accordance with EN ISO/IEC or act as sub-contractors to certification bodies (see 6.3). Testing laboratories may perform all tests in the product certification scheme for thermal insulation products for building equipment and industrial installations if they meet the requirements of 6.5 and Application procedures 7.1 Certification bodies Applicant certification bodies shall submit the following information to the Quality Assurance Secretariat: - Name and address - Contact person and his/her coordinates (address, tel. and fax number, address) - Person responsible for quality management - Person responsible for signing the contract with the national standardisation body - The body s internal certification scheme rules, including those that deal with appeals, complaints and disputes, to demonstrate its compliance with the requirements of the scheme rules. - Evidence of its accreditation according to EN Valid accreditation certificate - Records of recent evaluation visits by the EA member (upon request) - Evidence of notification where demanded by the Construction Products Directive (89/106/EEC) (or national recognition for non EU bodies) (see 6.2) - Accreditation for testing and inspection activities and/or evidence of accreditation of subcontracting testing laboratories and inspection bodies - For testing laboratories, the certification body shall provide evidence in its application that they comply with EN ISO/IEC and 6.5 and/or 6.6 of these scheme rules. - For external inspection bodies, the certification body shall provide evidence in its application that they comply with 6.4 of these scheme rules. - Evidence of experience - Evidence of existing mutual acceptance agreements of conformity assessment procedures and results. 6
7 Proposals for the extension of the number of testing laboratories, inspection bodies or of the scope thereof shall be handled in the same way. 7.2 Inspection bodies No specific application needs to be made. Inspection bodies application is part of the certification body s application. 7.3 Registered testing laboratories Testing laboratories applying for registration shall submit the following information to the Laboratory Group: - Name company/laboratory - Person responsible for the tests: - Address (location of the laboratory): - Tel. and fax number - Mailing address for samples (if different from above): - Mailing address for mail (if different from above, e.g. P.O. Box): - Evidence of notification in the framework of the Construction Products Directive (89/106/EEC) (see 6.2) - Evidence of accreditation according to EN ISO/IEC Technical specifications that the accreditation covers - Experience (on a regular basis) with comparative testing - Details about the test equipment that the laboratory intends to use for the tests An audit visit will take place at every laboratory candidate for registration. Registration shall only take place once an audit visit and acceptable comparative testing results have been assessed by the Laboratory Group. In addition, the testing laboratories application to become part of the scheme is part of the certification body s application. 7.4 Testing laboratories (other characteristics) No specific application needs to be made. The testing laboratories application is part of the certification body s application. 7.5 Manufacturers/Distributors Eligible parties Both manufacturers (producers) and distributors may apply for using the product certification scheme for thermal insulation products for building equipment and industrial installations. The certification and/or inspection body involved must have access to the production facilities. Note: In the framework of these scheme rules, producer means: 7
8 - the manufacturer of the product, when he is established in the European Community, and any other person presenting himself as the manufacturer by affixing to the product his name, trade mark or other distinctive mark, or the person who reconditions the product; - the manufacturer's representative, when the manufacturer is not established in the European Community, or, if there is no representative established in the Community, the importer of the product; - other professionals in the supply chain, insofar as their activities may affect the performances of a product; distributor means: any professional in the supply chain whose activity does not affect the performances of a product Application Applicants shall submit the following information to the Certification body: - Applicant s name and address - Manufacturer s name and address (if the applicant is not the manufacturer) - Business location(-s) and address - Place(-s) of production concerned - Name of product(-s) concerned - Contact person and his/her coordinates (address, tel. and fax number, address) - Person responsible for quality management - Person (name and function) responsible for signing the contract with the certification body - Technical documentation comprising (at least): - Product type(-s), together with technical data about the product(-s) - Production facility(-ies), line(-s) or unit(-s) producing the product(-s) - The manufacturing method (in a general way) - Proposed declared performances - Technical reports, demonstrating compliance with the technical specifications - Technical data, derived from FPC, demonstrating compliance with the technical specifications - Information about the FPC system - Traceability system - If available, copy of the EN ISO 9001 certificate(-s) (or similar) - If available, evidence of testing already performed. This work may be taken into account - Proposed inspection body and/or testing laboratory (optional) 8. Certification scheme 8.1 Common acceptance of conformity assessment procedures and results Mutual recognition of conformity assessment procedures and results between actors in the scheme is of fundamental importance. 8.2 Relationship with the Construction Products Directive (89/106/EEC) Conformity assessment tasks performed in the framework of compliance with the Construction Products Directive (CPD, 89/106/EEC), as amended, will be taken into account, as far as they have been performed in accordance with these scheme rules. 8
9 The scheme rules will adopt all decisions with regard to conformity assessment with the technical specifications (see 2), taken by Sector Group 19 Thermal insulation of the Group of Notified Bodies under the CPD. 8.3 Attestation system General The attestation scheme is based on Product certification system 5 in accordance with ISO/IEC Guide 67 and consists of: - Tasks for the manufacturer: - Implementation and maintenance of a factory production control system - Testing of samples taken at the factory by the manufacturer in accordance with a prescribed test plan. - Tasks under responsibility of the certification body: - Sample taking of products, representative for the product to be placed on the market - Initial type testing (ITT) - Initial inspection of factory and of FPC - Continuous surveillance, assessment and approval of factory production control - Audit-testing of samples taken at the factory These tasks are performed in accordance with the relevant product specification (see 2) and EN and EN ISO Additional requirements are specified in annexes to the scheme rules. When all requirements have been met by the manufacturer, the Certification body issues a certificate of conformity of the product. Note: Continuous surveillance, assessment and approval of factory production control and audit-testing of samples taken at the factory are conformity assessment activities performed once the certificate has been issued Initial type testing (ITT) Minimum requirements for ITT are specified in Appendix D Factory Production Control (FPC) Minimum requirements for FPC are specified in Appendix A Inspection and surveillance of the factory and factory production control A checklist for FPC inspections is given in Appendix A Audit testing Audit testing requirements have been specified in the relevant product standard (see 2) and in EN
10 8.4 Certificates Each individual product covered by the certification contract shall have its own unique identifier in the form of the manufacturer s commercial product name and/or code that appears on the product at the point of sale, and can only be assigned to a single certificate. More than one individual product may be covered by an individual certificate, but an individual certificate shall not cover products that comply with different technical specifications as presented in 2. An individual certificate may cover products from different production units, lines and plants. 9. Fees The scheme rules foresee a fee system to cover license fees and the operating cost of the secretariat(-s) involved. The fee system is specified in Appendix E. Costs covering testing, inspection and assessment between manufacturer and third parties are not governed by the scheme rules, but are negotiated by the contracting parties. 10. Website The -Mark website is the place where up to date information is found including product data of certified products. It allows a paper free system to an advanced extent. Papers that will remain, such as print outs of certificates, will refer to the web site as the only up to date information. As the web site only includes official information it is open for reading to all without any password. The official information on the web site(s) as registered by the scheme web manager includes: - The scheme rules - Information on manufacturers and products as found on the product labels, but no information on grouping of products for FPC or audit testing, inspection records and test results. - Lists of names and addresses for empowered bodies and registered testing laboratories can be found on the web site, but information on the relationship between empowered bodies and test results from comparative testing among laboratories shall not be published. The layout of the web site and updating of pure text (e.g. scheme rules, announcements) and the list of empowered bodies and testing laboratories is the responsibility of the -Mark scheme web master. Each certification body is responsible for continuous updating of its own part of the database. 11. Rules for handling complaints, disputes and appeals 11.1 General All complaints regarding the -Mark scheme, shall be dealt with in accordance with these specific scheme rules, and in accordance with the principles laid down in EN
11 11.2 Complaints about certified products Complaints about certified products may be lodged with the manufacturer or with the certification body concerned, or with the Quality Assurance Secretariat. In the latter case a copy of the complaint is also sent to the relevant certification body. The manufacturer of certified products shall: keep a record of all complaints relating to a product s compliance with requirements of the relevant European standard and the manufacturer's performance declaration and make these records available to the empowered organisation when requested; take appropriate action in respect of such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification; document the actions taken. The certification body shall ensure that the manufacturer investigates complaints as soon as possible and, where appropriate, advice the complainant of the outcome. If the investigations of the certification body reveal non-compliance with the requirements of the relevant European standard or these scheme rules, the action arising from the investigation of this complaint is notified by the certification body in a registered letter to the manufacturer Complaints about certification bodies Complaints regarding the actions of a certification body may be lodged with the certification body concerned, or with the Quality Assurance Secretariat. In the latter case a copy of the complaint is also sent to the relevant certification body. The certification body shall deal with the complaint using its own complaints procedure, in accordance with the principles laid down in EN The Quality Assurance Secretariat shall be informed of the complaint and of the outcome and react if needed Disputes about test results Disputes regarding test results should be addressed to the certification body responsible for the placing of the test work with the laboratory involved. The certification body shall deal directly with the test laboratory involved using the complaints procedure of the certification body, in accordance with the principles laid down in EN In the event that a challenge of test results cannot be resolved, e.g. by comparative testing in the presence of the two disputing parties, the arbitration procedure (11.5) shall be followed. 11
12 11.5 Test result arbitration procedure. The certification body shall take samples as required preferably from the original production in question. Test specimens from the sample shall be tested for the property in dispute at an agreed 2 nd registered laboratory in the presence of both the manufacturer and the certification body. The number of test specimens tested shall be agreed between parties (e.g. large enough to enable a statistical comparison with the original results). A comparison shall be made between the test results obtained by the initial registered laboratory and the results obtained by the 2 nd registered laboratory to detect variations or to confirm similarity (if statistics are used the population shall be the same at a confidence level relevant for the test). If the second results are seen to be from the same population, the original results will be upheld, even where the result changes the pass/fail assessment. In the event that the results obtained by the 2 nd registered laboratory cannot be confirmed as from the same population as the original results, the results obtained by the 2 nd registered laboratory in the presence of both the manufacturer and the certification body shall be used. Both the manufacturer and the certification body shall have access to the test results from the 2 nd laboratory and details of the test procedures used, to enable both parties to investigate any possible nonconformity within their respective systems, and take the appropriate corrective actions Appeals Appeal to a certification body The manufacturer may lodge an appeal with the certification body to whom he addressed an application for the right to use the -Mark. The certification body for that purpose maintains its own appeal procedure, in accordance with the principles laid down in EN The appeal does not suspend the decision against which it is made. Appeals can only be related to the certification process carried out by, or under the responsibility of the certification body. An appeal should be lodged, by registered letter, with the certification body within one month of the formal notification of the contested decision. The certification body shall formally give its answer within one month of receipt of the appeal Appeal to the Quality Assurance Secretariat Manufacturers may lodge an appeal directly with the Quality Assurance Secretariat in the following cases: when an appeal is rejected or in case of lack of response by the certification body; If the appeal is in respect of the interpretation of the principles contained in this document. 12
13 The appeal procedure does not suspend the decision against which it is made. It shall be notified to the Quality Assurance Secretariat by registered letter, within one month of the formal notification of the contested decision. In the event of an appeal being addressed by the manufacturer to the Quality Assurance Secretariat, the secretariat prepares a decision within one month of receipt. The decision is formally notified to the manufacturer and to the certification body by the secretary. The Quality Assurance Secretariat may ask for possible expert assistance/advice by it's choice depending on the actual case 12. Labelling The labelling of products certified in accordance with these scheme rules may consist of the following marks if requested: - The CE Marking in accordance with the previsions of the Construction Products Directive (89/106/CEE), complemented by EC Guidance paper D, and with the harmonised product standard (see 2); - The -Mark, the design of which is shown in Annex 1. The -Mark includes an identification code referring to the Certification Body. The labelling combining the CE Marking with the -Mark shall be located as specified in the harmonised product standard (see principle of example in Annex 1). NOTE In addition the -Mark may be licensed for use in conjunction with a mark granted by an empowered/authorised certification body, demonstrating conformity with the European standard. 13. Right to affix the -Mark After decision of the Management Group the Quality Assurance Secretariat will inform about the authorisation of a certification body for the right to use the -Mark, can conclude a contract with this certification body pursuant to a license agreement. Formal application for the granting of a licence to use the -Mark is made through signing a contract between the manufacturer and the chosen certification body which sets their relationship, with respect to the implementation of the system for the product(s) concerned. Only those applicants having obtained a licence to affix the -Mark by means of the procedures laid down in these scheme rules shall be entitled to use the -Mark. 14 Transitional arrangements The transitional arrangements are presented in Appendix F. Annex 1: Example of labelling combining the marks, i.e. the CE Marking and the -Mark 13
14 NOTE See annex ZA of the relevant product standard for the precise rules for CE marking. XXXX Any Company Rue du Producteur, 50 Country XX XXXX-CPD-YYYY EN Product A Reaction to fire Class A1 Thermal conductivity: see Manufacturer s Literature MW EN T2 ST(+)650 CS(10)20 WS MV1 CL6 14
Check-list for auditors. Audit visit at candidate registered laboratories
Check-list for auditors Audit visit at candidate registered laboratories 1 Contents Introduction Laboratory documentation required by the standard(s), available for inspection by the auditor Items to be
Copyright, Language, and Version Notice The official language of this [Certification Protocol] is English. The current version of the [Certification
Copyright, Language, and Version Notice The official language of this [Certification Protocol] is English. The current version of the [Certification Protocol] is maintained on the Bonsucro website: www.bonsucro.com.
Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC. GNB-CPD position paper from SG17 - EN 1090-1:2009
GNB-CPD SG17 Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC NB-CPD/SG17/09/069 Issued: 7 September 2009 APPROVED GUIDANCE GNB-CPD position paper from SG17
Memorandum of Understanding
Memorandum of Understanding between Department for Business, Innovation and Skills and United Kingdom Accreditation Service Page 1 of 13 Contents 1 Purpose... 3 2 Background... 3 3 Scope of activity...
DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
29.3.2014 Official Journal of the European Union L 96/149 DIRECTIVE 2014/32/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating
Testing Rules for Thermal Conductivity October 2015
Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity (October 2015) 1 Normative references (to be inserted as additional chapter in the Testing Rules for Panels) 1.
COMMISSION REGULATION (EU)
L 122/22 Official Journal of the European Union 11.5.2011 COMMISSION REGULATION (EU) No 445/2011 of 10 May 2011 on a system of certification of entities in charge of maintenance for freight wagons and
Federal Institute for Materials Research and Testing (BAM) Pyrotechnics Division 2.3 Explosives D -12200 Berlin Berlin, 2013-12-10
Federal Institute for Materials Research and Testing (BAM) Pyrotechnics Division 2.3 Explosives D -12200 Berlin Berlin, 2013-12-10 Pyrotechnic Articles Directive 2007/23/EC Information on the Conformity
Georgios Katsarakis Europäische Kommission
Georgios Katsarakis Europäische Kommission Implementing the Construction Products Regulation (EU) 305/2011 G. Katsarakis European Commission, DG Enterprise and Industry Unit B-1: Sustainable Industrial
WORKING DOCUMENT FOR SCC CONSULTATION CONSTRUCT09/874 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL
WORKING DOCUMENT FOR SCC CONSULTATION CONSTRUCT09/874 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL New Approach Industries, Tourism and CSR Construction, Pressure Equipment, Metrology
CEN Certification Board
CEN Certification Board CCB: n.a. Date: 2011-03-24 Draft Resolution 9/2011: Draft for the Cooperation Agreement between CEN and VDI The CCB, having received CCB doc N 543 and N 577 about a Keymark scheme
AVERTISSEMENT Vous trouverez ci-dessous la version française de ce Guidance Paper suivie de la version anglaise
AVERTISSEMENT Vous trouverez ci-dessous la version française de ce Guidance Paper suivie de la version anglaise !!"#$%$ %$ &'# %%%( $ # $ %$ # %%") %$ #% $!* $(%$ ($%% +$ (,& #$- * ($%%* $ $ % + $%%$ %!%%
QSS 0: Products and Services without Bespoke Contracts.
QSS 0: Products and Services without Bespoke Contracts. Amendment History Version Date Status v.1 Dec 2014 Updated For 2015 deployment Table of Contents 1. DEFINITIONS 3 2. INTRODUCTION 3 3. WORKING WITH
Network Certification Body
Network Certification Body Scheme rules for assessment of railway projects to requirements of the Railways Interoperability Regulations as a Notified and Designated Body 1 NCB_MS_56 Contents 1 Normative
Your essential guide to CE Marking
Your essential guide to CE Marking CE marking A guide for window and door fabricators This guide provides essential information that will help you with your preparations for CE marking. A flowchart is
How To Write A European Technical Assessment
European Technical Assessment Regulation Date of UBAtc Board of directors acceptance: 16 September 2013 Date of entry into force: 16 September 2013 This version does not supersede any previous version
QUALITY SYSTEM REQUIREMENTS FOR PHARMACEUTICAL INSPECTORATES
PHARMACEUTICAL INSPECTION CONVENTION PHARMACEUTICAL INSPECTION CO-OPERATION SCHEME PI 002-3 25 September 2007 RECOMMENDATION ON QUALITY SYSTEM REQUIREMENTS FOR PHARMACEUTICAL INSPECTORATES PIC/S September
Manual for ITC's clients, 2013. Conformity assessment of ACTIVE IMPLANTABLE MEDICAL DEVICES pursuant to Council Directive 90/385/EEC
Manual for ITC's clients, 2013 Conformity assessment of ACTIVE IMPLANTABLE MEDICAL DEVICES pursuant to Council Directive 90/385/EEC Institute for Testing and Certification, inc., Czech Republic, EU 1.
ISCC 103 Quality Management. Quality Management ISCC 11-03-15 V 2.3-EU
ISCC 103 Quality Management Quality Management ISCC 11-03-15 V 2.3-EU Copyright notice ISCC 2011 This ISCC document is protected by copyright. It is freely available from the ISCC website or upon request.
Assessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011
1. plan 1) Goal: Assessment and verification of the constancy of performance of the products as described by the manufacturer in his Declaration of Performance through: initial inspection of the manufacturing
European Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
The Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors
23. december 2010 The Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors The Danish Enterprise and Construction Authority s market surveillance of construction
DOCUMENTED PROCEDURE MANUAL
NAPIT REGISTERED INSTALLERS DOCUMENTED PROCEDURE MANUAL CONTENTS 1. INTRODUCTION 2. DEFINITIONS 3. RESPONSIBILITY FOR QUALITY 4. DOCUMENT AND DATA CONTROL 5. CUSTOMER ENQUIRIES AND QUOTATIONS 6. CONTRACTS
General Protocol relating to the collaboration of the insurance supervisory authorities of the Member States of the European Union March 2008
CEIOPS-DOC-07/08 General Protocol relating to the collaboration of the insurance supervisory authorities of the Member States of the European Union March 2008 CEIOPS e.v. - Westhafenplatz 1 60327 Frankfurt
PUBLICATIONS. Introduction
Page: 1 of 10 Introduction 1. The requirements of this document supplement the Factory Production Control requirements given in Table 1 of PN111 by giving the specific requirements for Factory Production
EA-7/01. EA Guidelines. on the application. Of EN 45012. Publication Reference PURPOSE
Publication Reference EA-7/01 EA Guidelines on the application Of EN 45012 PURPOSE The purpose of the document is to provide explanations with a view to harmonise the application of ISO/IEC Guide 62/EN
Frequently Asked Questions. Unannounced audits for manufacturers of CE-marked medical devices. 720 DM 0701-53a Rev 1 2014/10/02
Frequently Asked Questions Unannounced audits for manufacturers of CE-marked medical devices 720 DM 0701-53a Rev 1 2014/10/02 What is an unannounced audit?... 6 Are unannounced audits part of a new requirement?...
DECISIONS ADOPTED JOINTLY BY THE EUROPEAN PARLIAMENT AND THE COUNCIL
L 218/82 EN Official Journal of the European Union 13.8.2008 DECISIONS ADOPTED JOINTLY BY THE EUROPEAN PARLIAMENT AND THE COUNCIL DECISION No 768/2008/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of
EA IAF/ILAC Guidance. on the Application of ISO/IEC 17020:1998
Publication Reference EA IAF/ILAC-A4: 2004 EA IAF/ILAC Guidance on the Application of ISO/IEC 17020:1998 PURPOSE This guidance document is for ISO/IEC 17020: General Criteria for the operation of various
TRANSPORT FOR LONDON (TfL) LOW EMISSIONS CERTIFICATE (LEC) GUIDANCE NOTES FOR THE COMPANY AUDIT PROCESS. LEC (Company Audit) Guidance Notes
TRANSPORT FOR LONDON (TfL) LOW EMISSIONS CERTIFICATE (LEC) GUIDANCE NOTES FOR THE COMPANY AUDIT PROCESS LEC (Company Audit) Guidance Notes Glossary of Terms Transport for London (TfL) London Low Emission
Certification Regulations and Requirements. International Certification Management GmbH
Certification Regulations and Requirements of (ICM) General These Certification Regulations and Requirements apply to the auditing, certification and maintenance of the certification of management systems.
System Basics for the certification of sustainable biomass and bioenergy
ISCC 201 System Basics System Basics for the certification of sustainable biomass and bioenergy ISCC 10-04-19 V 1.15 10-04-19 Copyright notice ISCC 2010 This ISCC document is protected by copyright. It
Construction Products Regulation
Construction Products Regulation (305/2011/EU) Engineers Ireland 27 th September 2013 Sarah Neary BE MBA CEng MIEI Senior Adviser Building Standards Environment, Community and Local Government What has
Policy Briefing. Frequently Asked Questions on the Construction Products Regulation and CE marking. December 2012. Background
Frequently Asked Questions on the Construction Products Regulation and CE marking December 2012 Background The following list of frequently asked questions has been produced by an MPA Working Group and
EA Document on. Accreditation. For Notification Purposes
Publication Reference EA-2/17 INF: 2014 EA Document on Accreditation For Notification Purposes PURPOSE The document presents the policy agreed by EA Members for accreditation of Conformity Assessment Bodies
DEPARTMENT OF ENERGY AND CLIMATE CHANGE. GREEN DEAL CODE OF PRACTICE (Version 4)
DEPARTMENT OF ENERGY AND CLIMATE CHANGE GREEN DEAL CODE OF PRACTICE (Version 4) 23 June 2014 DEPARTMENT OF ENERGY AND CLIMATE CHANGE GREEN DEAL CODE OF PRACTICE (Version 4) This Code of Practice was laid
DOCUMENT CS/1: SCHEME DESCRIPTION AND BENEFITS
WELDING FABRICATOR CERTIFICATION SCHEME DOCUMENT CS/1: SCHEME DESCRIPTION AND BENEFITS 6 th Edition July 2012 Issued under the authority of the Governing Board for Certification All correspondence should
Application of ISO/IEC 17011 for the Accreditation of Food Safety Management Systems (FSMS) Certification Bodies
IAF Mandatory Document Application of ISO/IEC 17011 for the Accreditation of Food Safety Management Systems (FSMS) Certification Bodies (IAF MD 16:2015) Version 2 Food Safety Management Systems (FSMS)
DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL. of 12 December 2006
L 374/10 EN Official Journal of the European Union 27.12.2006 DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating
Guidance Note on the Construction Products Regulation
Guidance Note on the Construction Products Regulation Version 1 - April 2012 APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION Guidance Note on the Construction Products Regulation
An Alternative Method for Maintaining ISO 9001/2/3 Certification / Registration
International Accreditation Forum, Inc. An Alternative Method for Maintaining ISO 9001/2/3 Certification / Registration A Discussion Paper The International Accreditation Forum, Inc. (IAF) operates a program
ETSI TS 119 403 V2.1.1 (2014-11)
TS 119 403 V2.1.1 (2014-11) TECHNICAL SPECIFICATION Electronic Signatures and Infrastructures (ESI); Trust Service Provider Conformity Assessment - Requirements for conformity assessment bodies assessing
System Basics for the certification of sustainable biomass and bioenergy
ISCC 201 System Basics System Basics for the certification of sustainable biomass and bioenergy ISCC 11-03-15 V 2.3-EU Copyright notice ISCC 2011 This ISCC document is protected by copyright. It is freely
EA-6/02 M: 2013. EA Guidelines on the Use of EN 45 011 and ISO/IEC 17021 for Certification to EN ISO 3834. Publication Reference PURPOSE
Publication Reference EA-6/02 M: 2013 EA Guidelines on the Use of EN 45 011 and ISO/IEC 17021 for Certification to PURPOSE EN ISO 3834 The purpose of this document is to provide the basis for the harmonisation
DOCUMENT CAESAS/1: SCHEME DESCRIPTION AND BENEFITS
CONFORMITY ASSESSMENT FOR THE EXECUTION OF STEEL & ALUMINIUM STRUCTURES DOCUMENT CAESAS/1: SCHEME DESCRIPTION AND BENEFITS 2nd Edition July 2012 Issued under the authority of the Governing Board for Certification
of 28 September 2007 (Status as of 1 April 2010)
English is not an official language of the Swiss Confederation. This translation is provided for information purposes only and has no legal force. Ordinance on Data Protection Certification (DPCO) 235.13
DHI DANETV Test Centre Quality Manual
Purpose This quality manual has been prepared to comply with the requirements from the EU ETV pilot programme and the international standard for inspection, ISO/IEC 17020. The quality manual is integrated
CP14 ISSUE 5 DATED 1 st OCTOBER 2015 BINDT Audit Procedure Conformity Assessment and Certification/Verification of Management Systems
Certification Services Division Newton Building, St George s Avenue Northampton, NN2 6JB United Kingdom Tel: +44(0)1604-893-811. Fax: +44(0)1604-893-868. E-mail: [email protected] CP14 ISSUE 5 DATED 1 st OCTOBER
Raad voor Accreditatie (Dutch Accreditation Council RvA) Assessment of Conformity Assessment Schemes
Raad voor Accreditatie (Dutch Accreditation Council RvA) Assessment of Conformity Assessment Schemes Document code: RvA-T033-UK Version 3, 28 februari 2014 A Rv A-Explanatory note describes the policy
03/05/14 REVISOR RSI/JC RD3945
1.1 Department of Commerce 1.2 Proposed Permanent Rules Relating to Commerce; Thermal Insulation Standards; 1.3 Materials and Installation 1.4 7640.0100 AUTHORITY; PURPOSE; INCORPORATIONS BY REFERENCE.
JOHN HART GENERATING STATION REPLACEMENT PROJECT. Schedule 9. Quality Management
JOHN HART GENERATING STATION REPLACEMENT PROJECT Schedule 9 Quality Management SCHEDULE 9 QUALITY MANAGEMENT TABLE OF CONTENTS 1. QUALITY MANAGEMENT SYSTEM... 1 1.1 Quality Management System...1 1.2 Project
Voluntary Certification Scheme for Traditional Health Practitioner
ANNEX-3 Voluntary Certification Scheme for Traditional Health Practitioner 0. Introduction 0.1 This document defines the criteria to be followed by the bodies certifying persons against specific requirements,
ETSI EN 319 403 V2.2.2 (2015-08)
EN 319 403 V2.2.2 (2015-08) EUROPEAN STANDARD Electronic Signatures and Infrastructures (ESI); Trust Service Provider Conformity Assessment - Requirements for conformity assessment bodies assessing Trust
TERMS AND CONDITIONS FOR THE NATIONAL MANAGEMENT SYSTEMS CERTIFICATION SCHEME
TERMS AND CONDITIONS FOR THE NATIONAL MANAGEMENT SYSTEMS CERTIFICATION SCHEME CONTENTS Page 1 Introduction 2 2 Definitions 3 3 Certification Services 5 4 Certificates of Registration 5 5 Obligations of
IAF Mandatory Document for the Transfer of Accredited Certification of Management Systems
IAF MD 2:2007. International Accreditation Forum, Inc. IAF Mandatory Document IAF Mandatory Document for the Transfer of Accredited Certification of Management Systems (IAF MD 2:2007) IAF MD2:2007 International
SANITARY AND PHYTOSANITARY MEASURES (SPS)
TEXTUAL PROPOSAL SANITARY AND PHYTOSANITARY MEASURES (SPS) Article 1 Scope and coverage This Chapter applies to all SPS measures that may, directly or indirectly, affect trade between the Parties. This
Management Systems Recognition Booklet
Management Systems Recognition Booklet Page 1 of 15 Contents Revision History... 4 Related Documents... 4 1 Management Systems Recognition Booklet... 5 2 Accreditation Status... 5 3 The Recognition Process...
CE mark now! Mandatory CE marking of construction products 1 July 2013
CE mark now! Mandatory CE marking of construction products 1 July 2013 Mandatory CE marking of construction products 1 July 2013 From 1 July 2013, construction products covered by a harmonised standard
The certification process
TS004(COS)v01 The certification process for COSMOS standard Standard in force available on www.cosmos-standard.org or sent on request. 1 Contents I. When to apply... 3 II. The different steps in the certification
IMQ RULES. Contents. IMQ Rules - Product certification
IMQ RULES PRODUCT CERTIFICATION "ELECTRIC ENERGY METERS AND METER UNITS" PRODUCT OF NEW MANUFACTURING Contents IMQ Rules - Product certification Particular Rules for the Electric energy meters and meter
Accreditation in Europe
Accreditation in Europe Facilitating regulatory compliance and international trade ACCREDITATION INSPECTION TESTING CALIBRATION EXAMINATION VERIFICATION CERTIFICATION About the EA The EA is appointed by
Smart Meters Programme Schedule 2.5. (Security Management Plan) (CSP South version)
Smart Meters Programme Schedule 2.5 (Security Management Plan) (CSP South version) Schedule 2.5 (Security Management Plan) (CSP South version) Amendment History Version Date Author Status v.1 Signature
European technical approval
Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating
STATUTE OF THE COMMONWEALTH SECRETARIAT ARBITRAL TRIBUNAL
STATUTE OF THE COMMONWEALTH SECRETARIAT ARBITRAL TRIBUNAL Adopted by Commonwealth Governments on 1 July 1995 and amended by them on 24 June 1999, 18 February 2004, 14 May 2005, 16 May 2007 and 28 May 2015.
LIFEMARK VILLAGE SCHEME RULES A SIX-PILLAR QUALITY ASSURED RETIREMENT COMMUNITY
LIFEMARK VILLAGE SCHEME RULES A SIX-PILLAR QUALITY ASSURED RETIREMENT COMMUNITY Version 8.0: July 2013 Contents 1. Definitions... 1 2. Introduction... 4 3. Purpose, objectives and scope of the Scheme...
Audit of the control body through the monitoring of compliance with control plan. Measures for the irregularities
Workshop on verification of compliance with product specification for PDO, PGI and TSG Audit of the control body through the monitoring of compliance with control plan Measures for the irregularities Viktorija
COUNCIL DIRECTIVE 92/42/EEC of 21 May 1992 on efficiency requirements for new hot-water boilers fired with liquid or gaseous fuels
1992L0042 EN 11.08.2005 003.001 1 This document is meant purely as a documentation tool and the institutions do not assume any liability for its contents B COUNCIL DIRECTIVE 92/42/EEC of 21 May 1992 on
CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems
Date(s) of Evaluation: CHECKLIST ISO/IEC 17021:2011 Conformity Assessment Requirements for Bodies Providing Audit and Certification of Management Systems Assessor(s) & Observer(s): Organization: Area/Field
REQUIREMENTS FOR CERTIFICATION BODIES TO DETERMINE COMPLIANCE OF APPLICANT ORGANIZATIONS TO THE MAGEN TZEDEK SERVICE MARK STANDARD
REQUIREMENTS FOR CERTIFICATION BODIES TO DETERMINE COMPLIANCE OF APPLICANT ORGANIZATIONS TO THE MAGEN TZEDEK SERVICE MARK STANDARD Foreword The Magen Tzedek Commission has established a standards and certification
ACT on Payment Services 1 ) 2 ) of 19 August 2011. Part 1 General Provisions
ACT on Payment Services 1 ) 2 ) of 19 August 2011 Part 1 General Provisions Article 1. This Act sets out rules for the provision of payment services, including: 1) the conditions for provision of payment
Working Party on Control of Medicines and Inspections. Final Version of Annex 16 to the EU Guide to Good Manufacturing Practice
Version 8 (final) EUROPEAN COMMISSION ENTERPRISE DIRECTORATE-GENERAL Single market, regulatory environment, industries under vertical legislation Pharmaceuticals and cosmetics Brussels, July 2001 S\common\legal-legislation\75-319nd81-851\91-356\eudralexvol4\Annex
The Danish Energy Agency will carry out inspections in October 2013. We will check the CE marking of the smoke alarms you sell or use.
Table of Contents Table of Contents... 1 The Danish Energy Agency will carry out inspections in September and October 2013... 2 What is CE marking of a construction product?... 3 Where can you find the
Specific Conditions for the Assessment of Management Systems and Product Certifications
between DQS CFS GmbH, named DQS hereafter, with its contract partner, named the client" hereafter. 1 Assessment of Management Systems and DQS assesses the client s management system, or parts thereof,
GENERAL OPERATIONS MANUAL FOR ASTM PRODUCT CERTIFICATION PROGRAM
GENERAL OPERATIONS MANUAL FOR ASTM PRODUCT CERTIFICATION PROGRAM INTERNATIONAL Standards Worldwide Issued September 25, 2012 Version 5.0 BY AMERICAN SOCIETY FOR TESTING AND MATERIALS INTERNATIONAL ASTM
Regulations for certification of quality management systems
Regulations for certification of quality management systems 00 24/04/2013 Annulla e sostituisce il documento Regulations for certification of quality management systems in rev. 14 SG DIR AD Rev. Data Descrizione
Certification Process Requirements
SAAS Certification Process Requirements SAAS Procedure 200 Social Accountability Accreditation Services, June 2010 Accreditation Process and Policies SAAS Normative Requirements SAAS maintains a set of
Certification Procedure of RSPO Supply Chain Audit
: 1 of 19 Table of Contents 1. Purpose 2. Scope 3. Unit of Certification 3.1 Identity Preserved, Segregation, Mass Balance, 3.2. Book and Claim 4. Definitions 5. Responsibilities 5.1 Head of the Certification
LAB 37 Edition 3 June 2013
LAB 37 Edition 3 June 2013 Accreditation Requirements for Sampling and Testing in Accordance with the Drinking Water Testing Specification (DWTS) CONTENTS SECTION PAGE 1 Introduction 2 2 Regulatory requirements
INTEROPERABILITY UNIT
INTEROPERABILITY UNIT MODULES FOR THE PROCEDURES FOR ASSESSMENT OF CONFORMITY, SUITABILITY FOR USE AND EC VERIFICATION TO BE USED IN THE TECHNICAL SPECIFICATIONS FOR INTEROPERABILITY Reference: Version
COMMISSION OF THE EUROPEAN COMMUNITIES. COMMISSION REGULATION (EC) No /..
EN EN EN COMMISSION OF THE EUROPEAN COMMUNITIES Brussels, XX/XX/2007 COM(2006) XXX COMMISSION REGULATION (EC) No /.. of [ ] implementing Council Regulation (EC) No 1085/2006 establishing an instrument
GUIDE TO IMPLEMENTING A REGULATORY FOOD SAFETY AUDITOR SYSTEM
GUIDE TO IMPLEMENTING A REGULATORY FOOD SAFETY AUDITOR SYSTEM FEBRUARY 2016 2 Contents Introduction... 4 Scope and objectives... 5 Scope... 5 Objectives... 5 Responsibilities... 5 The role of the licensee
CONTROL PROCESS NATURAL ORIGIN AND ORGANIC CANDLES AND HOME FRAGRANCES
TS004(GPA)v03en v25/11/2015 CONTROL PROCESS NATURAL ORIGIN AND ORGANIC CANDLES AND HOME FRAGRANCES The aim of the present document is to describe the key steps of the control process. This document is
Practice Note. 10 (Revised) October 2010 AUDIT OF FINANCIAL STATEMENTS OF PUBLIC SECTOR BODIES IN THE UNITED KINGDOM
October 2010 Practice Note 10 (Revised) AUDIT OF FINANCIAL STATEMENTS OF PUBLIC SECTOR BODIES IN THE UNITED KINGDOM The Auditing Practices Board (APB) is one of the operating bodies of the Financial Reporting
IAF Mandatory Document
IAF MD15:2014. IAF Mandatory Document IAF MANDATORY DOCUMENT FOR THE COLLECTION OF DATA TO PROVIDE INDICATORS OF MANAGEMENT SYSTEM CERTIFICATION BODIES PERFORMANCE (IAF MD15:2014) Issued: 14 July 2014
NABL NATIONAL ACCREDITATION
NABL 160 NABL NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES GUIDE for PREPARING A QUALITY MANUAL ISSUE NO. : 05 AMENDMENT NO : 00 ISSUE DATE: 27.06.2012 AMENDMENT DATE: -- Amendment
Rules for the certification of event sustainability management system
Rules for the certification of event sustainability management system In force from 10/09/2014 RINA Services S.p.A. Via Corsica, 12 16128 Genova Tel. +39 010 53851 Fax +39 010 5351000 E-MAIL: [email protected],
UK Aerospace Industry Controlled Other Party (ICOP) Auditor Authentication Scheme
How to apply for and maintain UK Aerospace Industry Controlled Other Party (ICOP) Auditor Authentication Scheme Contents 1. General information 2 2. IRCA Aerospace auditor authentication grades 3 3. Criteria
Having regard to the Treaty on the Functioning of the European Union, and in particular Article 114 thereof,
28.8.2014 Official Journal of the European Union L 257/73 REGULATION (EU) No 910/2014 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 23 July 2014 on electronic identification and trust services for electronic
Requirements for certification bodies situation and scope for harmonisation
INTERNATIONAL TASK FORCE ON HARMONIZATION AND EQUIVALENCE IN ORGANIC AGRICULTURE (ITF) Food and Agriculture Organization of the United Nations International Federation of Organic Agriculture Movements
Align Technology. Data Protection Binding Corporate Rules Processor Policy. 2014 Align Technology, Inc. All rights reserved.
Align Technology Data Protection Binding Corporate Rules Processor Policy Confidential Contents INTRODUCTION TO THIS POLICY 3 PART I: BACKGROUND AND ACTIONS 4 PART II: PROCESSOR OBLIGATIONS 6 PART III:
THE CONSTRUCTION PRODUCTS DIRECTIVE (COUNCIL DIRECTIVE 89/106/EEC)
THE CONSTRUCTION PRODUCTS DIRECTIVE (COUNCIL DIRECTIVE 89/106/EEC) Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member
Recommendations for companies planning to use Cloud computing services
Recommendations for companies planning to use Cloud computing services From a legal standpoint, CNIL finds that Cloud computing raises a number of difficulties with regard to compliance with the legislation
PRODUCT CERTIFICATION RULES GOVERNING THE SCHEME JANUARY 2006
THE GAS SAFETY CERTIFICATION FOR GAS APPLIANCES AND COMPONENTS PRODUCT CERTIFICATION RULES GOVERNING THE SCHEME JANUARY 2006 MKP220.01 Issue Date: 2007-Oct-09 SAI Global Limited Copyright 2007 - ABN 67
ANNEX F. Organic agriculture (Art. 11) ARTICLE 1. Objectives
ANNEX F Organic agriculture (Art. 11) ARTICLE 1 Objectives Without prejudice to their obligations with regard to products not originating in the Member States or other legislative provisions in force,
OLB certification process for Forestry Companies GP01
OLB certification process for Forestry Companies GP01 Reference: GP01 OLB FC 1.2 version, 22/03/2013 Bureau Veritas Certification France 60 Général de Gaulle Avenue - 92046 Paris - La Défense Cedex - France
EUROPEAN INSPECTION AND CERTIFICATION COMPANY S.A.
EUROPEAN INSPECTION AND CERTIFICATION COMPANY S.A. 89 CHLOIS & LIKOVRISEOS STR. - 144 52 METAMORFOSI TEL: +30 210 6253927, 210 6252495 INTERNET SITE: www.eurocert.gr E-mail: [email protected] FAX: +30
AGREEMENT ON TECHNICAL BARRIERS TO TRADE. Having regard to the Uruguay Round of Multilateral Trade Negotiations;
Page 117 AGREEMENT ON TECHNICAL BARRIERS TO TRADE Members, Having regard to the Uruguay Round of Multilateral Trade Negotiations; Desiring to further the objectives of GATT 1994; Recognizing the important
26.3.2014 A7-0365/133
26.3.2014 A7-0365/133 Amendment 133 Amalia Sartori on behalf of the Committee on Industry, Research and Energy Report A7-0365/2013 Marita Ulvskog Electronic identification and trust services for electronic