Single Phase Magnetic Card Electricity Meter



Similar documents
Polyphase kwh Electricity Meter

5235 Single Phase Credit Meter

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

The Old Brewery Works, Lr Ellacombe Church Rd, Torquay. UK. TQ1 1JH Tel: Fax:

GSM-AUTO+ GSM Controller with Internal Power Supply User manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

500r+ Installation and User Guide

PAC1 Door Access Controller

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Aurora PAY AS YOU GO. How it works

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

User Manual Single Phase Energy Meter

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

S4000TH HART. HART Communication Manual

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

IDS X-Series User Manual D Issued July 2012

TMS TANK MANAGEMENT SYSTEM

GSM HOME SECURITY SYSTEM

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Maximum Demand Control

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

WD-AMX Water Detection Controllers

Automatic Telephone Dialer TD-101(W)

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual

Control/Communicator Installation Manual

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Conventional Fire Detection and Extinguishant Control System Specification

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Keep it Simple Timing

Six-defense zone Display Alarm System. User Manual

Programming and Operations Guide

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

Operating instructions IV / 2007

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Data Sheet. Electro-mechanical counters Hengstler 800 series

Wireless Auto-dial Intruder Alarm System

EBDSPIR-PRM, EBDSPIR-PRM-IP

Z-Wave Gas Reader. Product Manual NQ-9121-EU. From your Z-wave network directly to the cloud! DESCRIPTION

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

Automatic start of a generator

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Thyristor-controlled power supplies and battery chargers

ADM1TE 5/30A DIN rail single phase two wire energy meter

Elster Metering Systems. EC Directive 2004/22/EC

AUTODIALLER / QUICKDIALLER - SA132

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

ATS-505. GB Version 1

Digital Radio/DAB+/FM RDS digital clock radio with dual alarm Operating instruction

Code of Practice on Pay As You Go Metering

Stop Alert Flasher with G-Force sensor

How To Use A Ppanasonic Cell Phone With A Cell Phone From A Cellphone From Alexa (Panasonic) For A Long Distance Phone From An Older Model (Panoramos) For An Extra Money (Panamontani

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Business/Home GSM Alarm System. Installation and User Manual

GSM Home Alarm System User Manual.

HEAT PUMP PROGRAMMABLE THERMOSTAT

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

How To Control A Car Alarm On A Car With A Remote Control System

Destiny Destiny Owners Manual

Auto Dialer. Manual E-921APQ E-921GPQ

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

D200+ Auto-Dialler Installation/Operators Manual

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

Digital Keypad Use s Manual

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Quick start: Energy Switch EU

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

SX460. Generator Automatic Voltage Regulator Operation Manual

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Manual for Fire Suppression & Methane Detection System

JESTER OPERATING MANUAL

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Fire Alarm Control Panel. Family. Operating Manual

How To Program An Autodialer

User Guide for the Orchid Key Phones KP416 & KP832

OPL BASIC. Dosing System for Professional Laundry machines. Contents

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

Micro Wireless Electricity Monitor

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Keypad Locks User Guide

GTEC transfer switch open transition

MANTA Piston Distributor for Oil and Fluid Grease

Flexible Counter Series in DIN size 24 x 48 mm

User Manual. Before installation and use, please read the user manual carefully.

Short information Parameters are programmed via front-side membrane keypad

Transcription:

Single Phase Magnetic Card Electricity Meter Model Type: 5188A USER MANUAL issue 1.0

Contents 1 Introduction 2 1.1 Overview 2 2 Technical Data 2 2.1 Meter Element 2 2.2 Main Contactor & Auxiliary Relay 2 2.3 Power Supply 2 2.4 Temperature Range 3 2.5 Dimensions 3 3 Normal Functional Operation 3 3.1 Normal Operation Display 3 3.2 Additional Displayed Information 4 3.3 Fixed Charge Collection 6 3.3.1 Standing Charge 6 3.3.2 Debt Collection 6 3.4 Rate Switching 6 3.5 Disconnection 6 3.5.1 No Remaining Credit 6 3.5.2 Reverse Detection 6 3.5.3 Gas Lighter Fraud 6 3.6 Disconnection Override 7 3.7 Audible Disconnect Warning 7 3.8 Emergency Credit 7 3.8.1 Invocation 7 3.8.2 Reduction 7 3.8.3 Expiry 7 3.9 Pre payment card tokens 7 3.9.1 Valid Cards 7 3.9.2 Card Errors 9 3.9.3 Emergency Credit Repayment 9 4 Push Button Programming 9 4.1 Programming Method 9 4.1.1 Reset 11 5 'Mini-programmer' 11 5.1 Protocol Overview 11 5.1.1 Debt/Week and Total Debt 11 5.1.2 Credit 11 5.1.3 Total Credit 11 5.1.4 Standing Charge per Week 11 5.1.5 E Credit Value and availability 11 5.1.6 Pence per Unit for Rates 1-4 12 5.1.7 System Options 12 5.1.8 Area Code 12 5.1.9 Time/Date 12 6 Appendix A 13 6.1 Anti Creep Detection 13 6.2 Starting Current 13 6.3 Wiring Diagram 13 Page 1

5188 1. Introduction 1.1 Overview This document covers the specification and operation of the CPM5188A single phase prepayment card operated electricity meter. The main features of the meter are:- 1) Certified & approved to BS EN61036, Class 2 2) All solid state with 16 character LCD 3) Standing Charge + Debt collection 4) Emergency Credit 5) Up to 4 tariff rates 6) Internal Real Time Clock with programmable switching 7) Disconnection override facility 8) Auxiliary relay Terminals 9) Audible disconnect warning 10) Reverse power detection 2. Technical Data The CPM5188A is an alternating Current Static Watt Hour Meter, Class 2. The unit will comply with BS EN61036 (alternating current static watt-hour meters for active energy class 2) and any relevant standards contained therein. The unit will also comply with additional tests as specified by The Office of Gas & Electricity Markets (Ofgem). 2.1 Meter Element The red LED mounted on the front panel will pulse at a rate of 1000 pulses per kwh. Power registration is recorded in non-volatile memory under control of the microprocessor which is updated every 24 hours and in the event of a power failure. There are separate registers for each rate. 2.2 Main Contactor & Auxiliary Relay Contactor current rating: Main Terminal dimensions: Auxiliary relay type: Auxiliary terminal dimensions: 100 Amp 8.0mm to 8.2mm 2 Amp floating 3.0mm minimum NOTE: Auxiliary terminals become inputs for the external time switch option. 2.3 Power Supply Rated Voltage : 240V Standard / 230V on request Operating Voltage Range: From 0.9 to 1.1 Rated Voltages Current range: 20 to 100A Standard Frequency: 50Hz Standard Page 2

2.4 Temperature Range Operating Range: -10 C to 45 C Limit range of operation: -20 C to 55 C Storage Range* : -25 C to 70 C This complies with BS EN61036: section 4.3.1 *Maximum period of 6 hours at the extremes of this temperature range. 2.5 Dimensions Height = 172mm Width = 126mm Depth = 90mm 3 Normal Functional Operation This section covers the general operation of the CPM5188A meter. For ease of explanation during the following sub sections not every combination of option is covered. For a complete list of options please refer to section 5. 3.1 Normal Operation Display During normal operation the display on the meter will be one of those shown below. Display Contactor(s) Remarks RY CRED XXX.XX Closed The consumer has xxx.xx of credit remaining. RY represents the current tariff DEBT XXX.XX Open The consumer has used up all credit and has accumulated a debt of xxx.xx XXX.XX+ ZZZ.ZZE Closed The consumer has selected emergency credit while still in credit. xxx.xx represents the amount of real credit available while zzz.zz represents the available emergency credit. When xxx.xx reaches 000.00 the display will change to the format below. RY CRED XXX.XXE Closed The consumer has selected emergency credit remaining. xxx.xx represents the emergency credit remaining while RY is the current tariff. DEBT XXX.XXE Open The consumer has selected and used up all emergency credit. xxx.xx is the total the consumer is in debt. Page 3

3.2 Additional Displayed Information When the meter is operating normally pressing the button will allow various parameters to be displayed. A preset option determines whether the display automatically cycles through all the parameters or waits for the display button to be pressed between each parameter. If during a manual advanced cycle the display button is not pressed within 30 seconds the meter will revert to its normal operation. The meter can be configured with up to 3 separate display cycles, each made up from one or more of the parameters listed below in any sequence. The 3 cycles are: A) The display with no card in the card meter. B) The display with a token card in the card reader. C) The display with a meterman programming card in the card reader or (optionally) for 30 seconds after a valid hand-held Mini-programmer communication (Meterman programming must be disabled) The table on the next page gives some examples of additional display configuration. NOTE: Some parameters may not be displayed if not applicable, e.g. Rate 3 & 4 parameters would not be displayed if the meter were configured for only 2 rates. Page 4

Display **DISPLAY*TEST** Remarks Test all characters positions on the display DEBT CLR XXX.XX Only displayed when emergency credit has been invoked. xxx.xx is the amount of debt to clear to be back in credit. TIME HH/MM Current Time DAY DD/MM/YYYY Current Date T.CREDIT XXXXX Total value of credit that has been inserted T.CARDS XXXXX Total number of cards inserted STCH/WK XXX.XX Optionally FXDCH/WK XXX.XX Standing Charge per week T.DEBT XXX.XX Optionally T.REPAY XXXXX.XX Total debt to be recovered DEBT/WK XXX.XX Optionally REPAY/WK XXX.XX Debt collection per week FXDCH/WK XXX.XX Optionally TOTCH/WK XXX.XX Fixed charge per week (Debt collection and standing charge) KWH XXXXX RY KWH for rates 1 to 4 (0 dp) KWH XXXXX.XXRY KWH for rates 1 to 4 (2 dp) KWH XXXXX TOT Total KWH (0 dp) KWH XXXXX.XX TOT Total KWH (2 dp) RATE Y XXX.XX ppu The tariff for rate Y is displayed (4 rates max) E.CRED XXX.XX Emergency Credit E.AVAIL XXX.XX If the meters pre-paid credit is above this point then emergency credit is not selectable AREA CODE XXX Card token area identification code Page 5

3.3 Fixed Charge Collection The fixed charge element consists of 2 parts: 1) A standing charge 2) A debt repayment The standing charge and debt repayment are both programmed into the meter as weekly values, which are divided internally by 100 and used to reduce the remaining credit. (Or increase the debt) every 100 th of a week (1.68 hours.) 3.3.1 Standing Charge The weekly standing charge is also collected every 1/100 th of a week. 3.3.2 Debt Collection (Optional) The debt collection operates identically to the standing charge except it is also deducted from a pre set debt outstanding. When the debt outstanding becomes zero the debt collection is stopped. 3.4 Rate Switching The meter is configurable to have up to 4 different charge rates and is available with an internal or external time switch option. 3.5 Disconnection 3.5.1 No remaining Credit When the prepaid credit expires and the meter has gone into debt the main and auxiliary contactors will be opened, thus disconnecting the power. To restore power, sufficient token cards must be inserted to clear the outstanding debt. An emergency credit facility is also available to reconnect power. 3.5.2 Reverse Detection (Optional) If reverse power is detected above a pre-determined level the consumers supply can be disconnected and/or reverse running indicated by the display flashing alternately between its normal display and RED (Reverse Energy Detection) Reverse detection can only be reset via a hand-held Mini-programmer or a reset card. 3.5.3 Gas Lighter Fraud (Optional) Certain external influences such as a gas lighter may cause the microprocessor within the meter to reset. As these influences would never occur normally the meter can be configured so that after 4 abnormal resets within 24 hours power will be disconnected the meter shall display the message LOCK OUT. In this condition, the meter does not function. Page 6

3.6 Disconnection Override (Optional) The meter will not disconnect the economy rate when going from a prepaid credit into debt. In this situation disconnection is delayed until a different rate is selected and the facility is not made available again until the meter is back into pre paid credit. The economy rate number can be set via GIMX to any of the 4 rates. 3.7 Audible Disconnect Warning (Optional) The meter will give an audible warning when the emergency credit availability point is reached. If enabled the warning will consist of a 30 second buzz followed by 10 thirty second interval pulsed buzzes. 3.8 Emergency Credit If the prepaid credit is below a given limit or the meter has gone into debt, an emergency credit facility may be invoked by pressing the button marked emergency credit. The meter s operation whilst in emergency credit is explained in the following subsections. 3.8.1 Invocation Emergency credit is a pre-set reserve that can be selected by pressing the Emergency Credit button when the pre-paid credit has fallen below a given level or the meter has gone into debt. The display will change to XXX.XX+ ZZZ.ZZE or CRED XXX.XXE to indicate the amount of credit / emergency credit left to the consumer. The debt is to be repaid before the meter is back into prepaid credit. (DEBT CLR XX.XX) may be viewed by pressing the display button. 3.8.2 Reduction The amount of emergency credit remaining (Displayed as CRED XXX.XXE) will be reduced as electricity is consumed and the fixed charge collected. The DEBT will also be increased by the same amount. 3.8.3 Expiry Once the emergency credit has fallen to zero the supply will be disconnected and the display will show DEBT XXX.XXE, where XXX.XX represents the total amount owed by the customer and the E signifies the emergency credit has been totally used. 3.9 Pre payment card tokens 3.9.1 Valid Cards When a valid token card is inserted its total monetary value is credited to the meter and its acceptance is indicated by the message TOKEN VALUE YY being displayed for 5 seconds. On removal the card is erased and visibly marked. Three examples of this are given below: Page 7

Example 1:- Display Action RY CRED 121.99 INSERT 5 TOKEN CARD TOKEN VALUE 5 RY CRED 126.99 Example 2:- Display Action DEBT 10.99 INSERT 5 TOKEN CARD TOKEN VALUE 5 RY DEBT 5.99 Example 3:- Display Action DEBT 2.99 INSERT 5 TOKEN CARD TOKEN VALUE 5 RY CRED 2.01 Page 8

3.9.2 Card Errors The message CARD ERROR may be displayed if the card was inserted too quickly, too slowly or the card was invalid, the message CREDIT FULL is displayed if a token card is inserted that would cause the pre-paid credit to become greater than 999.99. If either of the above messages is displayed then on removal, the card is not erased and may be used at a later date. 3.9.3 Emergency Credit Repayment When the preset emergency credit has expired, card tokens must be inserted that are of sufficient value to give a pre paid credit of at least 1 above the emergency credit DEBT. 4 Push Button Programming 4.1 Programming Method After the insertion of a valid METERMAN card the following parameters can be viewed/modified using the two push buttons on the meter. #PROGRAMMING# E CRED XXX.XX Emergency Credit Value E.AVAIL XXX.XX Emergency Credit Availability point RATE Z XXX.XXppu 1/100 OF PENCE PER kwh for all rates T.DEBT XXXX.XX Outstanding Debt DEBT/WK XXX.XX Debt Collection Per Week STCH/WK XXX.XX Standing Charge per Week ZZ:ZZ RW XX YY Displayed for up to 15 time switches TIME HH:MM Current Time DAY DD/MM/YYYY Current Date EC&DIS TO CLEAR Clear Meter enable request To display/modify a particular parameter first insert a meterman card upon which the message REMOVE CARD will be displayed. On removing the card the message PROGRAMMING will be displayed. Next press and release the display button until the required parameter is displayed. Each press of the emergency credit button will rotate the cursor one place right through the programmable setting of the displayed parameter. To change the setting do not release the Page 9

emergency credit button when the correct position is reached; whilst holding down the EC button, each press of the display button will then increment the value above the cursor. To store the new value advance the display to the next parameter by pressing the display button. If no buttons are pressed within 30 seconds the display will revert to its normal operation mode without saving the new value. EXAMPLE If it were desired to change the value of rate1 the sequence of events would be as follows: STEP ACTION DISPLAY 1 Insert a valid Meterman Card REMOVE CARD 2 Remove Meterman Card #PROGRAMMING# 3 Press and release the display button E.CRED XXX.XX 4 Press and release the display button E.AVAIL XXX.XX button 5 Press and release the display button RATE 1 000.00ppu button 6 Press and HOLD the emergency credit button RATE 1 000.00ppu button 7 Press and release the display button while still holding the emergency credit button until the correct value is shown RATE 1 010.00ppu 8 Release the emergency credit button and repeat steps 7,8 & 9 until all digits are set correctly 9 Press the display button to store the new setting and display the next parameter RATE 2 000.00ppu Page 10

4.1.1 Reset Display Remarks EC&DIS TO CLEAR If rate 1 was set to 0 then EC&DIS TO CLEAR will be displayed at the end of the programming cycle. If both the emergency credit and display buttons are pressed together then the following parameters are reset to 0:- A) Emergency Credit Value B) Emergency Credit availability Point C) Pence per kwh for all rates D) Outstanding Debt E) Debt Collection per Week F) Standing Charge per week G) Total Cards H) Total Credit I) Credit (Debt) J) Reverse running 5 Mini-programmer 5.1 Protocol Overview The optical interface on the meter is provided to allow the configuration of various parameters in the meter such as pence per unit. The following sub sections detail the available programming commands. 5.1.1 Debit/Week and Total Debt The total debt is settable in the range 0 to 9999.99. The debt repayment per week is settable in the range 0 to 99.99 5.1.2 Credit The remaining credit is settable in the range -99.99 to +99.9999 5.1.3 Total Credit The total credit is settable in the range 0 to 9999 5.1.4 Standing Charge per Week The standing charge is settable in the range 0 to 99.99 per week. 5.1.5 E Credit value and availability The emergency credit is settable in the range 0 to 99.99 Page 11

5.1.6 Pence per Unit for Rates 1 4 The pence per unit for each of the 4 rates are settable in the range 0 to 999.99ppu 5.1.7 System Options The following options are also settable via the hand-held Mini-programmer:- Number of rates Determines how many rates the meter will have, selectable in the range 1-4 Push Button Program Start Starts a programming cycle, in the same way that a Meterman card would; if enabled. Credit Only Fixed Charge Either the fixed charge is collected only when the meter is in pre-paid credit OR the fixed charge is collected according to the factory set options. Disconnection Override The meter can be configured so that whilst in a specific 24-hour period the power will not be disconnected even if credit has expired. When the disconnection override time period elapses the facility is not made available again until the meter is back in a pre-paid credit otherwise the meter will remain disconnected. Audible Warning Either no audible warning is given before the supply is disconnected OR an audible warning will be given at the point that the emergency credit could be invoked. The warning will consist of a 30 second beep followed by 10 x 30 second interval pulsed beeps. The warning can be stopped only by invoking emergency credit or by inserting a valid token card. Credit Meter The meter can be switched from normal prepayment mode to kwh credit mode for override and or conference purposes etc. 5.1.8 Area Code The area card code register can be set in the range 0-255 (Decimal) 5.1.9 Time/Date The following time and date parameter are settable:- Seconds, Minutes, Hours, Day, Date, Month, Year. Page 12

6 Appendix A 6.1 Anti Creep Detection Anti creep occurs if an average power of 12.5 watts (+-20%) or less is detected for a period of 4 minutes and 48 seconds. Activation of abti-creep is indicated by the red LED being continuously lit. This function is reset as soon as the average power over 4 minutes and 48 seconds exceeds 12.5 watts (+-20%); the LED then returns to pulsing as normal. 6.2 Starting Current The meter starts to register at 100ma. 6.3 Wiring Diagram This image shows the main + auxiliary terminal connections for the 5188A Single Phase Card Meter:- 2Amp Auxiliary Connection 1 2Amp Auxiliary Connection 2 Live Input Neutral Input Neutral Load Live Load Page 13