3M Quick Connect System (QCS) 2810 Models 2810A and 2810B



Similar documents
3M Quick Connect System (QCS) 2814

Expanding a 40-Type Cabinet

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

3M Integrated Splitter Block BRCP-SP

3M xdsl Line Conditioners 3620

3M Dynatel Triple Play Customer Service Test Set INS970

3M Scotchcast Mine and Portable Cable Splice Kit

3M Serial Attached SCSI (SAS) Connector Boardmount Compliant Pin and Surface Mount, Vertical Receptacle

3M Pin Strip Header 2 mm 2 mm Solder Tail Straight & Right Angle, Surface Mount Straight 1512 Series

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

BIX Termination Blocks

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

Cables and Accessories Selection Guide

Scotchlok Connectors and Tools

Terminating 25-Pair Cable and 4-Pair Cross Connects

3M Wire Connectors. Reliable, high performing solutions for every wire connecting application. 3Innovation

3M Pin Strip Header Single and Dual Row.100,.235 /.318 Mating Length, Straight & Right Angle, Solder Tails 929 Series

3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

MTV-FS1 / FS1T / FSB375

24.2L M.A.N. V12 Engine Module

FTTX Solutions FDH 3000 Cross-Connect

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

Anthro Tablet Charging Cabinets

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

3M Wrist Strap and Footwear Tester 740. User s Guide

Advantium 2 Plus Alarm

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

SC, FC and ST * Hot Melt Fiber Optic Connectors

3 740 Wrist strap + shoe tester

Quick Tip Introduction. Repositioning the Hookswitch Tab. Wallmount Instructions for SoundPoint IP Phones

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

Dynatel 2273 Advanced Cable and Fault Locator

E8887 First Edition February 2014

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

I NTERFACE CABLE ADAPTER MODULE

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Retractable Screen. Replacement Screen Instructions

MICROMAPPER. Users Manual. LAN Wiremap Checker

Architect/Contractor Information Package

Quick Reference Guide Euro Style Terminal Blocks

Advanced Systems Tester 900AST

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

3M Scotchcast Electrical Resin 251 Two-Part, Oven-Curing, Class F, Rigid, Filled, Epoxy Liquid Resin

Installing Your 960 or 980 Server into a Rackmount Cabinet

Unpacking, Installation, and Customization

16/32 Channel 1U Rack Mount CCTV Power Supply

Integrated Home Networks

ATS Overhead Table Shelf System INSTRUCTION MANUAL

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

FLEX by 3M Light Module System

Sunny Boy Accessories SMA POWER BALANCER

Introduction... 3 Setting the Combination... 4 Securing the DEFCON CL... 5 Locking the DEFCON CL to your Notebook Computer...

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Scotchgard Multi-Layer Protective Film 1004

Scotch-Weld PUR Easy 250 Adhesive Applicator

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

Mini-led spotlight with magnetic base

BroadBand PowerShield. User Manual

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

MIRAGE. Set-Up Instructions.

How To Install A Power Supply (Uplast) With A Battery Pack

About this Manual. Support for Your Product

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

Ceiling Mount Air Handler Manual

ChargePoint Home. Installation Guide. ATTENTION: Please read thoroughly and keep this installation guide.

Zetron Desktop Microphone Manual F

TracRac G2. Overhead Rack Installation Instructions. TracRac Inc. 994 Jefferson St. FallRiver MA IN-42000_B

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

EMI Shielding Tapes Product Selection Guide. Trusted. Performance. from the. Tape Experts

Nest Learning Thermostat Installation Guide. Installation step-by-step

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Lionel O-27 Gauge 27 Path Remote-Control Switch Owner s Manual

GPS 35 USB. installation and quick start guide

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

12-Volt Negative Ground Installation Instructions

InHome Water Leak Detection Package

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Super Slider ADJUSTABLE FROM Model #HD26229

Installation Instructions

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

P O W E R S U P P L Y M A N U A L

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

HotLok Pass Through Blanking Panel

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Quick Reference Guide AMP CT Connector Series

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Discontinued. Volition. Fiber Optic Cable. 3Innovation

AUTOMATIC SWINGING DOOR

7 High-Resolution Digital Photo Frame

4RU High Density Shelf Installation Instructions

3M Stats and Status Software for 3M Detection System Model 8900/9900. Staff Guide

Transcription:

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B Instructions October 2010 3

Contents 1.0 General...3 2.0 Recommended Installation Procedure for 3M Quick Connect Systems 2810A and 2810B...3 3.0 Jumper Running...5 4.0 Testing...6 5.0 Accessories...7 2

1.0 General 1.1 The 3M Quick Connect System (QCS) 2810A cross-connect terminal block consists of the 10-pair 2810 terminal block with installed label holders for pair numbering, single pair jumper caps for hand termination of jumper wires on the front or jumper side of the block, and 5-pair covers for securing terminated feeder and distribution conductors on the back or cable side of the block. The block will accept 22 and 24 AWG plastic insulated jumper wire on the front or jumper side, and 22-26 AWG plastic insulated conductors on the back or cable side. The 2810A system requires use of punchdown tool for cable side termination. 1.2 The 3M Quick Connect System (QCS) 2810B cross-connect terminal block consists of the 10-pair 2810 terminal block with installed label holders for pair numbering, single pair jumper caps for hand termination of jumper wires on the front or jumper side of the block, and single pair caps for hand termination of feeder and distribution conductors on the back or cable side of the block. The block will accept 22 and 24 AWG plastic insulated jumper wire on the front or jumper side, and 22-26 AWG plastic insulated conductors on the back or cable side. 2.0 Recommended Installation Procedure for 2810A and 2810B Systems 2.1 Mount frames vertically to supports in cabinet or pedestal. Route feeder and distribution cables into the frames. Using tie wraps, secure cables to frame sides or back, fanning out binder groups above the frame positions where they will be terminated. Be sure to leave adequate length in binder groups to allow slack for possible future maintenance activities. Note: Depending on the specific installation (crossconnect cabinet, NID, etc.) the frame may be integrated into the application. 3

Using Frame: 3M Quick Connect System (QCS) 2810A Block on Frame 2.2 Mount the first block to the frame with the 5-pair covers facing out and oriented so the covers open down. 2.3 Fan wires into the block from above, leaving enough slack to allow future reentry to the cable side if necessary. Be sure wires extend at least 5 cm (2 in) past block to allow removal of cutoff wires after termination. 2.4 Use the 3M Punch-Down Tool 2810 or the standard tool 3M Punch-Down Tool SOR-OC to terminate cable conductors and cut off excess. See above for correct orientation and positioning of tool to ensure correct termination and cut-off. After terminating conductors and removing excess wire, close 5-pair covers, making sure they latch firmly to body. 2.5 Remove block from frame. Rotate block 180. backward and remount in same frame position with 1-pair jumper caps facing out. 3M logo on cap is in right-side up orientation. Push block firmly into place on frame. Cable pairs should now enter back side of the block from below. Repeat until all feeder and distribution blocks have been terminated and mounted to frame. Using Frame: 3M Quick Connect System (QCS) 2810B Block 2.6 Mount the first block to the frame with the label holders facing in and the single pair caps facing out and oriented so the caps open down. 4

2.7 Fan wires into the caps from above, leaving enough slack to allow future reentry to the cable side, if necessary. Open cable pair cap by pushing down on latch and rotating down. Cut cable wires to length. Insert cable wire ends A (tip) left and B (ring) right into the wire openings in cap, making sure they are inserted all the way to the back of the cap. 2.8 While holding the cable wires in place, close the cap and press to snap latch firmly into place 2.9 Terminate additional cable wires by repeating the above procedure. 2.10 Inspect wires for correct routing. Be sure caps are snapped firmly into place. 2.11 Remove block from frame. Rotate block 180 backward and remount in same frame position with 1-pair jumper caps facing out. 3M logo on cap is in right-side up orientation. Push block firmly into place on frame. Cable pairs should now enter back side of the block from below. Repeat until all feeder and distribution blocks have been terminated and mounted to frame. 3.0 Jumper Running 3.1 Open feeder pair jumper cap by pushing up on latch and rotating up. Insert jumper wire ends A (tip) left and B (ring) right into wire openings in cap, making sure they are inserted all the way to the back of the cap. 3.2 While holding the jumper wires in place, close the cap and press to snap latch firmly into place. 5

3.3 Route jumper wires to distribution pair through wire loops on block ends and through vertical and horizontal wireways. Cut jumper wires to appropriate length, leaving at least 5 cm (2 in) of slack. 3.4 Terminate the jumper wires to the distribution pair by repeating the procedure described in steps 3.1 and 3.2. 3.5 Terminate additional jumper wires by repeating the above procedure. 3.6 To remove jumper wires, open the cap and pull wires straight out from block. 4.0 Testing 4.1 Testing using the 3M Pair Test Probe 2827. 4.2 To test, insert probe onto cap as shown. Black lead to the left and the red lead to the right.testing does not interrupt the circuit. 6

5.0 Accessories 5.1 Accessories include frames of various sizes for mounting in cabinets or pedestals; a pair test probe for testing pair circuits on installed blocks;priority caps for identification of special circuits; the 3M Punch-Down Tool 2810 and the standard tool 3M Punch-Down Tool SOR-OC for termination of feeder and distribution cable pairs on 3M Quick Connect System (QCS) 2810A Blocks. (Tools not needed for 3M Quick Connect System (QCS) 2810B Blocks.) Accessories Test Probes 2827 2827XL 2827P 2827PC Priority Caps 2810PC-R 2810PC-P Replacement Caps 2810RC-O 2810RC-P Label Holders 2810L 2810L-P Frame 2810F 7

3M is a trademark of 3M Company. All other trademarks are the property of their respective owners. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Communication Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 1-800-426-8688 www.3mtelecommunications.com Please Recycle. Printed in USA. 3M 2010. All Rights Reserved.