3M xdsl Line Conditioners 3620

Size: px
Start display at page:

Download "3M xdsl Line Conditioners 3620"

Transcription

1 3M xdsl Line Conditioners 3620 Instructions 1.0 General 1.1 Document Purpose This document provides general and installation information necessary to install the 3M xdsl Line Conditioner. 1.2 Description The xdsl line conditioner is an analog device that is designed to improve available bandwidth through noise filtering and intelligent signal line conditioning. The line conditioner system employs patented TripleStream technology and is packaged in a sealed 3M enclosure which can be installed aerial, polemount and underground environments. Available Models Product Matrix DSL-LC-XX-XXXX-XXXX Type LPTP 3M xdsl Line Conditioners Application 3610 Aerial Only 3620 Aerial, Underground, and Pole Mount LINE Powered Triple Play (ADSL, ADSL2+) Count EPTP Express Powered Triple Play (ADSL, ADSL2+) 1 pr EPER Express Powered Extended Reach (ADSL) 5 pr A=Annex A B=Annex B January B 3

2 Product Number Product Description DSL-LC-1A-LPTP-3610 DSL Line Conditioner- 1pr- Line Powered Tripleplay-3610 DSL-LC-5A-LPTP-3610 DSL Line Conditioner- 5pr- DSL Line Powered Tripleplay-3610 DSL-LC-1A-LPTP-3620 DSL Line Conditioner- 1pr- DSL Line Powered Tripleplay-3620 DSL-LC-1A-EPTP-3610 DSL Line Conditioner- 1pr- Exp. Powered Tripleplay-3610 DSL-LC-5A-EPTP-3610 DSL Line Conditioner- 5pr- Exp. Powered Tripleplay-3610 DSL-LC-1A-EPTP-3620 DSL Line Conditioner- 1pr- Exp. Powered Tripleplay-3620 DSL-LC-1A-EPER-3610 DSL Line Conditioner- 1pr- Exp. Powered Extd. Reach-3610 DSL-LC-5A-EPER-3610 DSL Line Conditioner- 5pr- Exp. Powered Extd. Reach-3610 DSL-LC-1A-EPER-3620 DSL Line Conditioner- 1pr- Exp. Powered Extd. Reach Placement The 3M xdsl Line Conditioner is placed at an approximate mid-point between the DSLAM equipment and customer premises equipment, as determined per loop resistance. The line conditioner tunes its internal circuitry to compensate for distance, wire gauge and other plant variables, and conditions the DSL line to maximize rate and reach. See physical specifications in Table 1. DSLAM Line Conditioner CPE CO Length Total Loop Length CPE Length Tabe 1 Physical Specifications Closure Feature US Metric Width, including brackets 6.9 in. 175 mm Height, without brackets 15.7 in. 399 mm Length, cable stub 12 Feet 3.7 m Depth 4.2 in. 106 mm Cable stub type 3 pr Cat 3 24AWG Shielded, filled Operating Temp. -40 to 150 F I -40 to 65 C 1.4 Power Requirement Minimal power is required, and the 3M xdsl Line Conditioner is available with express powering or line powering. Line powering requires a maximum of 6 ma at -48VDC above voice needs.

3 2.0 Outside Plant (OSP) Considerations 2.1 Line Powering Line power will require the normal POTS line power of -48 to -55 VDC. This assumes one cable pair carries both power and signal. 2.2 Express Powering Express power will require a separate power source of a -48 to -55 VDC from the CO or RT and also a separate cable pair to transport the power to the unit. Up to 5 units(pairs) can be powered with a single power pair. WARNING Be careful not to damage any buried cables or service wires while digging to prepare a hole/trench, to expose cables or while driving stakes. 3.0 Installation 3.1 Installing the Unit 1. Choose DSL circuit - Per Company practice, ensure that the circuit is DSL ready. Remove load coils, bridgetap and verify that the pair is fault free. 2. Determine loop-placement location. Place the 3M xdsl Line Conditioner as close as possible to the ideal placement location within the total CO/DSLAM-to-CPE loop, per local or company practice; also refer to the Product Placement chart or the 3M DSL LC Placement calculator. The Placement Calculator can be found at: calculator/calc3m/calculator.aspx. 3. Route cable tail. Route the cable tail toward the splice case, pedestal, or housing. Follow company practice for cable support, slack, and storage concerns or trenching requirements. 4. Determine mounting type. The 3M line conditioner can be mounted in underground, aerial or pole mount applications. Consult local company practices to determine the mounting or installation type and the required equipment. 5. Mount the unit. Gather all materials, follow all safety precautions and local codes, prepare the installation site, and mount the unit. 6. Determine, measure, and mark cable tail sheath opening point. Sheath preparation and the length of exposed cable wire for splicing will depend on the type of splice housing used when splicing the cable tail. Adequate cable stub wire should be made available according to the existing splice arrangement. Mark the cable sheath opening point on the cable tail stub after determining or establishing an adequate length of cable wire to match the existing splice. 7. Score, cut, and open cable sheath. Always follow safety precautions when working with cables and cable opening and cutting tools. Perform the cable sheath opening procedure, per local practices. 8. Bond cable tail. Perform cable bonding with a cable bond clamp at the cable tail sheath opening, then bond the cable at the clamp to an approved ground with a bond strap or wire, all per local company practice. 9. Ground the line conditioner s ground stud. Connect the ground stud on the unit to an approved earth ground, per local company practice. 10. Perform splicing. Open the splice case and perform splicing per local company practice. Refer to the line powered or express powered Color Code Chart on the next page as needed. 11. Test. Test or verify the connections for proper operation and make any needed corrections, changes or adjustments, per local company practice. Verify -48 VDC is on the blue wire of the unit.

4 GROUNDING WARNING Always follow local codes and company practices for performing proper cable and site bonding and grounding. Perform all bonding and grounding prior to any electrical and communications connections. 3.2 Splicing the Unit Use the charts below to determine the LC pairs to splice to your network wires Color Code for 5 Line LPTP Central Office Pair 1 Tip/Ring White/Blue Central Office Pair 2 Tip/Ring White/Orange Central Office Pair 3 Tip/Ring White/Green Central Office Pair 4 Tip/Ring White/Brown Central Office Pair 5 Tip/Ring White/Slate Customer Pair 1 Tip/Ring Red/Blue Customer Pair 2 Tip/Ring Red/Orange Customer Pair 3 Tip/Ring Red/Green Customer Pair 4 Tip/Ring Red/Brown Customer Pair 5 Tip/Ring Red/Slate Color Code for 5 Line EPTP or EPER Black/Blue Black/Orange Central Office Pair 1 Tip/Ring White/Blue Central Office Pair 2 Tip/Ring White/Orange Central Office Pair 3 Tip/Ring White/Green Central Office Pair 4 Tip/Ring White/Brown Central Office Pair 5 Tip/Ring White/Slate Customer Pair 1 Tip/Ring Red/Blue Customer Pair 2 Tip/Ring Red/Orange Customer Pair 3 Tip/Ring Red/Green Customer Pair 4 Tip/Ring Red/Brown Customer Pair 5 Tip/Ring Red/Slate Power Pair Tip/Ring Black/Blue Color Code for Single Line LPTP Black/Orange Central Office Pair Tip/Ring White-Blue/Blue Customer Pair Tip/Ring White-Orange/Orange Color Code for Single Line EPTP or EPER White-Green/Green Central Office Pair Tip/Ring White-Blue/Blue Customer Pair Tip/Ring White-Orange/Orange Power Pair Tip/Ring White-Green/Green

5 Product Placeme Placement G uide Chart O C to s m h o tota l ohms in loop Express Pow ered Extend ed Reach max Express Pow ered Extend ed Reach ideal Express Pow ered Extend ed Reach center Express Pow ered Triple Pla y max Express Pow ered Triple Pla y Ideal Express Pow ered Triple Pla y center Line Pow ered Triple Play max Line Pow ered Triple Play Ideal Line Pow ered Triple Play center 3M xdsl Line Conditioners should be placed at the ideal loop resistance point. To find the ideal placement in your total loop: 1) Measure or calculate your application s total loop resistance, in Ohms, 2) find that ohms resistance number on Chart 1 s horizontal X axis, and 3) find its vertical intersection with Line 3 above (solid line) it to determine the ideal placement in the application s loop. Placeme nt G uide O C to s m h o tota l ohms in loop Express Pow ered Extend ed Reach max Express Pow ered Extend ed Reach ideal Express Pow ered Extend ed Reach center Express Pow ered Triple Pla y max Express Pow ered Triple Pla y Ideal Express Pow ered Triple Pla y center Line Pow ered Triple Play max Line Pow ered Triple Play Ideal Line Pow ered Tr iple Play center Example 1: 26 AWG 3.1 Km loop has a total resistance of 850 ohms. Find 850 ohms on the X-axis in the chart above and raise it vertically (follow arrows) to where it intersects Line 3 (at the bull s-eye) to find the ideal placement on the Y-axis (425 ohms). Lines 2 and 4 provide ideal minimum and maximum ranges. Example 2: 26 AWG 5.1 Km loop has a total resistance of 1400 ohms. Find 1400 ohms on the X-axis in the chart above and raise it vertically (follow arrows) to where it intersects Line 3 (at the bull s-eye) to find the ideal placement on the Y-axis (700 ohms). Lines 2 and 4 provide ideal minimum and maximum ranges.

6 3M is a trademark of 3M Company. Triplestream is a trademark of Phylogy Inc. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed.before using this product, you must evaluate it and determine if it is suitable for your intended application.you assume all risks and liability associated with such use.any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase.3m MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product.except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Communication Markets Division 3M Telecommunications 6801 River Place Blvd. Austin, TX Please Recycle. Printed in USA. 3M All Rights Reserved B

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer 3 Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer DSL User s Guide Future-Proof Testing Platform February 2009 78-8140-2658-5-A 2 3M Dynatel Advanced Modular System 965AMS 30-MHz

More information

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B 3M Quick Connect System (QCS) 2810 Models 2810A and 2810B Instructions October 2010 3 Contents 1.0 General...3 2.0 Recommended Installation Procedure for 3M Quick Connect Systems 2810A and 2810B...3 3.0

More information

3M Dynatel Triple Play Customer Service Test Set INS970

3M Dynatel Triple Play Customer Service Test Set INS970 3M Dynatel Triple Play Customer Service Test Set Advanced Diagnostics Software Options DELT, SELT and Spectral Analysis The Test Set has the ability to run advanced diagnostics in different scenarios to

More information

3M Integrated Splitter Block BRCP-SP

3M Integrated Splitter Block BRCP-SP The Network of Networks 3M Integrated Splitter Block BRCP-SP The 3M Integrated Splitter Block BRCP-SP is the latest generation of the Cross Connect System BRCP developed by 3M specifically for xdsl and

More information

3M Quick Connect System (QCS) 2814

3M Quick Connect System (QCS) 2814 Communication Markets Division 3M Quick Connect System (QCS) 2814 Designed for your broadband network The 3M Quick Connect System 2814 is a terminal/cross-connect system featuring integrated protection

More information

Expanding a 40-Type Cabinet

Expanding a 40-Type Cabinet Expanding a 40-Type Cabinet using the 3M Add-On Terminal 4220P 400-Pair and Jumper Trough Instructions January 2006 Table of Contents 1.0 General... 3 2.0 Cabinet Overall Descriptions... 3 3.0 Tools Required...

More information

3M Serial Attached SCSI (SAS) Connector Boardmount Compliant Pin and Surface Mount, Vertical Receptacle

3M Serial Attached SCSI (SAS) Connector Boardmount Compliant Pin and Surface Mount, Vertical Receptacle M Serial Attached SCSI (SAS) Connector 6 Gbps input/output connector for backplane applications Two contact mating levels for early-mate and latebreak allows blind mating or hot swap applications Capable

More information

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a

More information

Part No. P0943133 02. Business Communications Manager 2.5. BIX Box Wiring Guide

Part No. P0943133 02. Business Communications Manager 2.5. BIX Box Wiring Guide Part No. P0943133 02 Business Communications Manager 2.5 BIX Box Wiring Guide 2 Copyright 2001 Nortel Networks All rights reserved. May, 2001. The information in this document is subject to change without

More information

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

3M High Flex Life Cable.050 28 AWG Stranded, PVC 3319 Series M High Flex Life Cable.050" 28 AWG Stranded, PVC 19 Series Flex life of 100 million cycles at 1 /4 inch diameter 19 strands of high strength copper alloy provide the longest flex life available for dynamic

More information

Dynatel 2273 Advanced Cable and Fault Locator

Dynatel 2273 Advanced Cable and Fault Locator Dynatel 2273 Advanced Cable and Fault Locator Operators Manual September 1999 78-8097-6517-1-B TABLE OF CONTENTS Introduction... 2 Installing or Replacing the Batteries... 2 Initial Receiver Configuration...

More information

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C

Physical. Electrical. Environmental. Insulation: Contact: Plating: Temperature Rating: -55 C to +85 C M I/O Interconnect System 2.0 mm for IEEE 194 Wiremount Receptacle (Female) E206 Series Designed to mate to all M I/O Interconnect System 2.0 mm for IEEE 194 Boardmount Plugs Polarized to provide proper

More information

Scotchlok Connectors and Tools

Scotchlok Connectors and Tools Scotchlok Connectors and Tools Proven Solutions For Today s Applications A New Series of Tools and Connectors from 3M. 50 years ago, 3M introduced the industry s original insulation displacement connector

More information

Recommendations for Marking Communication Facilities with Use of 3M EMS Electronic Markers

Recommendations for Marking Communication Facilities with Use of 3M EMS Electronic Markers Recommendations for Marking Communication Facilities with Use of 3M EMS Electronic Markers Near-Surface Marker A small marker which is well-suited for bore holes in concrete or asphalt for marking flush-mount

More information

3M Scotchcast Mine and Portable Cable Splice Kit 8096-4

3M Scotchcast Mine and Portable Cable Splice Kit 8096-4 3M Scotchcast Mine and Portable Cable Splice Kit 8096-4 Installation Instructions 1.0 Kit Contents: 2 Funnels 3 EPDM Rubber Cold Shrink Cold Shrink Insulator 1 Wrap-around Mold Assemblies 2 Rubber Mold

More information

3M Wrist Strap and Footwear Tester 740. User s Guide

3M Wrist Strap and Footwear Tester 740. User s Guide 3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6

More information

Cables and Accessories Selection Guide

Cables and Accessories Selection Guide Cables and Accessories Selection Guide From data centers to robotics to patient monitoring equipment, we re committed to enabling the next generation of faster, smaller and smarter design. 3M offers an

More information

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France Title: Source: Author: Contact: What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France Jack Douglass Jack Douglass Paradyne Networks, Inc. Voice: 949-233-3558 Email:

More information

RTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation

RTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation RTEX Cable 2015/10/1 Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation Cable and Connector Page 2 2015/10/1 Rev. 5 Motor Business Unit, AIS Company The Kind of Ethernet

More information

FTTH ARCHITECTURE WHITE PAPER SERIES

FTTH ARCHITECTURE WHITE PAPER SERIES Not all FTTH networks are built the same. Since construction and outside plant account for the majority of total network costs, getting the architecture right has a major impact on the business case. The

More information

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

3M Twisted Pair Flat Cable.050 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series Wires are color-coded for easy identification Twist and flat repeat has variable length option Can be mass terminated

More information

EMI Shielding Tapes Product Selection Guide. Trusted. Performance. from the. Tape Experts

EMI Shielding Tapes Product Selection Guide. Trusted. Performance. from the. Tape Experts EMI Shielding Tapes Product Selection Guide Trusted Performance from the Tape Experts 3M EMI Shielding Tapes A wide variety of tapes for EMI shielding and grounding Copper, aluminum, and tin-plated copper

More information

Zetron Desktop Microphone Manual 025-9589F

Zetron Desktop Microphone Manual 025-9589F Zetron Desktop Microphone Manual 025-9589F Software License The Zetron software described in this manual is subject to the terms and conditions of Zetron's Software License Agreement, a copy of which is

More information

3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series

3M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series M Pin Strip Header.100,.295 Mating Length, Straight & Right Angle, Solder Tails 929 Series Stackable Tin Lead or gold plating available Solder stand-offs facilitate production wave soldering Board pin

More information

Architect/Contractor Information Package

Architect/Contractor Information Package Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the

More information

3M Pin Strip Header 2 mm 2 mm Solder Tail Straight & Right Angle, Surface Mount Straight 1512 Series

3M Pin Strip Header 2 mm 2 mm Solder Tail Straight & Right Angle, Surface Mount Straight 1512 Series M Pin Strip Header 2 2 Solder Tail Straight & Right Angle, Surface Mount Straight 1512 Series Mates with a variety of dual row 2 board mount and wire mount sockets High temperature insulator compatible

More information

2178-S Fiber Optic Splice Case

2178-S Fiber Optic Splice Case 2178-S Fiber Optic Splice Case Instructions March 1998 34-7041-6288-1-B 1 2 Table of Contents 3M 2178-S Splice Case Description... 4 1.0 General...4 2.0 Specifications...4 3.0 Kit Contents...5 3M 2178-S

More information

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Discontinued. Volition. Fiber Optic Cable. 3Innovation Volition Fiber Optic Cable Tough enough to take it. Easy to handle. The Volition Network Solution from 3M includes horizontal and backbone cable with 62.5/125 µm and 50/125 µm multimode fiber, and 9/125

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

How To Power A Powerline System On A Cell Phone Or Ipad Or Ipa Computer (For A Cell)

How To Power A Powerline System On A Cell Phone Or Ipad Or Ipa Computer (For A Cell) Digital Loop Carrier System 12:1 Multi-Line System 12 lines over a single twisted pair: Expand customer service to a range of up to 100,000 ft. without the expense of installing new copper G The 12:1 Multi-Line

More information

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series Wiper-on-wiper contact for reliable repetitive plugging Ultra-low signal skew for high data rate transmission

More information

Terminating 25-Pair Cable and 4-Pair Cross Connects

Terminating 25-Pair Cable and 4-Pair Cross Connects Terminating 25-Pair Cable and 4-Pair Cross Connects Estimated Time: 90 minutes Number of Teams: 2 Number of Team Members: one to four This Lab has four major parts that will be addressed separately. 1.

More information

About the BitStorm 6051 POTS Splitter

About the BitStorm 6051 POTS Splitter BitStorm 6051 Installation Instructions Document Number 6051-A2-GZ40-10 July 2002 About the BitStorm 6051 The BitStorm system enables simultaneous high-speed digital data access and analog voice service

More information

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION Page 1 of 11 ****This Standard Supercedes BECo CS2.13-2.3 & ComElectric OH Construction Manual, System Grounding Section, drawings CGND, GRDSUM, and C2**** 1.0 Bill of Materials GROUNDING AND BONDING POLE-MOUNTED

More information

3M Scotchcast Electrical Resin 251 Two-Part, Oven-Curing, Class F, Rigid, Filled, Epoxy Liquid Resin

3M Scotchcast Electrical Resin 251 Two-Part, Oven-Curing, Class F, Rigid, Filled, Epoxy Liquid Resin 3M Scotchcast Electrical Resin 251 Two-Part, Oven-Curing, Class F, Rigid, Filled, Epoxy Liquid Resin Data Sheet April 2013 Description 3M Scotchcast Electrical Resin 251 is a medium viscosity, rigid, Class

More information

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be

More information

KVM - DVI, USB 2.0, Cat 5 Extender

KVM - DVI, USB 2.0, Cat 5 Extender KVM - DVI, USB 2.0, Cat 5 Extender 330 feet (100 meters) EL5100 User Guide Powered by Thank you for purchasing the KVM - DVI, USB 2.0, Cat 5 Extender 330 feet (100 meters) Please read this guide thoroughly.

More information

3M Pin Strip Header Single and Dual Row.100,.235 /.318 Mating Length, Straight & Right Angle, Solder Tails 929 Series

3M Pin Strip Header Single and Dual Row.100,.235 /.318 Mating Length, Straight & Right Angle, Solder Tails 929 Series M Pin Strip Header Single and Dual Row.100,.25 /.18 Mating Length, &, Solder Tails 929 Series Stackable Gold, Matte Sn, or -Lead plating options High Temperature (PCT) plastic for Wave or IR soldering

More information

Broadband 101: Installation and Testing

Broadband 101: Installation and Testing Broadband 101: Installation and Testing Fanny Mlinarsky Introduction Today the Internet is an information superhighway with bottlenecks at every exit. These congested exits call for the deployment of broadband

More information

Nexus Technology Review -- Exhibit A

Nexus Technology Review -- Exhibit A Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.

More information

3 740 Wrist strap + shoe tester

3 740 Wrist strap + shoe tester 3 740 Wrist strap + shoe tester Operating Instructions April, 2001 740 wrist strap + shoe tester 3 < o.k. > 1 2 1 / 11 LED for «too w resistance» 740 wrist strap + shoe tester 3 < o.k. > 1 2 LED for «too

More information

UltraFED IIB. 30 MHz Far-End Device

UltraFED IIB. 30 MHz Far-End Device COMMUNICATIONS TEST AND MEASUREMENT SOLUTIONS UltraFED IIB 30 MHz Far-End Device Key Benefits Faster and more accurate than a single-ended test Eliminate driving to change line conditions Remotely set

More information

Advanced Systems Tester 900AST

Advanced Systems Tester 900AST Advanced Systems Tester 900AST Clear skies ahead with the 900AST TESTER The internal wiring in aircraft is under constant bombardment from age, vibration and moisture especially in airplanes that work

More information

2178-S Fiber Optic Splice Case and Accessories

2178-S Fiber Optic Splice Case and Accessories 2178-S Fiber Optic Splice Case and Accessories Tech Report October 1996 80-6109-3154-7 1 Contents: 1.0 Product Description... 3 2.0 Test Program Overview... 4 3.0 Environmental Tests... 5 4.0 Mechanical

More information

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual. www.gefentv.com

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual. www.gefentv.com Extender for HDMI 1.3 over CAT6 GTV-HDMI1.3-CAT6 User Manual www.gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:

More information

Communication, Signal & Data Cables

Communication, Signal & Data Cables Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication

More information

3M Electrically Conductive Adhesive Transfer Tape 9703

3M Electrically Conductive Adhesive Transfer Tape 9703 Technical Data April 2011 M Electrically Conductive Adhesive Transfer Tape 970 Product Description M Electrically Conductive Adhesive Transfer Tape 970 is a pressure sensitive adhesive (PSA) transfer tape

More information

Signal Manager Installation and Operation Manual

Signal Manager Installation and Operation Manual Signal Manager Installation and Operation Manual Rev.11/28/2008 Part # 26550007 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 CHAPTER 2: SYSTEM INSTALLATION... 4 HARDWARE

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

USB Rover 2850. 2-port USB 1.1 40m Cat 5 Extender. User Guide

USB Rover 2850. 2-port USB 1.1 40m Cat 5 Extender. User Guide USB Rover 2850 2-port USB 1.1 40m Cat 5 Extender User Guide Thank you for purchasing the USB Rover 2850, 2-port USB 1.1 40 m (131 ft) Cat 5 Extender Please read this guide thoroughly. FCC Radio Frequency

More information

Model SRMD Setra Remote Monitoring Display

Model SRMD Setra Remote Monitoring Display Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for

More information

VARIO PROX CARD READER INSTALLATION MANUAL

VARIO PROX CARD READER INSTALLATION MANUAL VARIO PROX CARD READER INSTALLATION MANUAL TABLE OF CONTENTS 1.0 INTRODUCTION...2 1.1 Legend...3 1.2 Terminology...4 2.0 MOUNTING...5 3.0 WIEGAND CONNECTION...6 4.0 AUX BUTTON INPUT...7 5.0 INSTALLER PROGRAMMING...8

More information

How To Design An Outside Plant (Osp) Network Design

How To Design An Outside Plant (Osp) Network Design Chapter 1 Introduction to Outside Plant Chapter 1 offers an overview of outside plant (OSP) fundamentals. An introduction to standardization and valuable resources for the OSP designer are also included

More information

Code of Practice. For. Internal Telecommunication Wiring

Code of Practice. For. Internal Telecommunication Wiring Code of Practice For Internal Telecommunication Wiring IDA CP L1 Issue 1, 2000 Copyright Reserved Info-Communications Development Authority of Singapore Equipment and Cabling Regulation Department 8 Temasek

More information

Lightning Protection Guide. PTP 400 and 600 SERIES

Lightning Protection Guide. PTP 400 and 600 SERIES Technical Note Lightning Protection Guide MOTOROLA POINT-TO-POINT BROADBAND WIRELESS SOLUTIONS MOTOROLA PTP 400 and 600 SERIES WIRELESS ETHERNET BRIDGES Table of Contents Introduction.... 3 Recommended

More information

Category 5 Outside Plant

Category 5 Outside Plant SYSTIMAX Solutions Category 5 Outside Plant Application Guide www.commscope.com Contents Design Option 3 Installation Cable Blocking Instructions 4,5 Mounting SYSTIMAX Protector 6 Mounting Additional Protectors

More information

The Evolution of the U.S. Telecommunications Infrastructure Over the Next Decade

The Evolution of the U.S. Telecommunications Infrastructure Over the Next Decade The Evolution of the U.S. Telecommunications Infrastructure Over the Next Decade BROAD BANDWIDTH THROUGH DSL TTG4: McAdams, Cioffi, Bloom, Hargadon Digital Subscriber Line (DSL) telecommunication service

More information

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information. Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the

More information

DSL - Digital Subscriber Line Installation, Maintenance & Troubleshooting

DSL - Digital Subscriber Line Installation, Maintenance & Troubleshooting Hands-On DSL - Digital Subscriber Line Installation, Maintenance & Troubleshooting including: CAT5 & CAT6 Preparation, Installation & Testing BICSI CECs This course has been approved for CEC credits by

More information

Original instructions Tina 3A/Aps Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially

More information

TR-013 Interfaces and System Configuration for ADSL Central Office Issue: 1.0 Issue Date: January 1999

TR-013 Interfaces and System Configuration for ADSL Central Office Issue: 1.0 Issue Date: January 1999 TECHNICAL REPORT Interfaces and System Configuration for ADSL Central Office Issue: 1.0 Issue Date: January 1999 The Broadband Forum. All rights reserved. Notice The Broadband Forum is a non-profit corporation

More information

Current Probes. User Manual

Current Probes. User Manual Current Probes User Manual ETS-Lindgren L.P. reserves the right to make changes to any product described herein in order to improve function, design, or for any other reason. Nothing contained herein shall

More information

Series 510 Submersible Level Transmitters

Series 510 Submersible Level Transmitters Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable

More information

3 Thermal Transfer Acrylate Label Material 3921

3 Thermal Transfer Acrylate Label Material 3921 3 Thermal Transfer Acrylate Label Material Technical Data April, 2008 Product Description 3M Thermal Transfer Acrylate Label Material consists of a non-topcoated acrylate facestock designed for thermal

More information

AXIS T81B22 DC 30W Midspan

AXIS T81B22 DC 30W Midspan INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial

More information

SingleNet Single Cable Control System

SingleNet Single Cable Control System Single Cable Control System Economical, Reliable and Expandable Two-Wire Single Cable System DRIP/MICRO IRRIGATION PRODUCTS Single Cable Control System System Manager or Irrigation Controller Controls

More information

T-Extender E-Extender

T-Extender E-Extender T-Extender E-Extender TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only

More information

Part I - Installation

Part I - Installation 400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS ddcwp_manual_gb_revisions.ai 10/23/06 Page 1 Date: Station 1 2 3 4 5 6 7 8 CUSTOM WATERING PLAN 3 Program Controller Description Program A Program B Program C Duration Duration Duration DDC WP Series Waterproof

More information

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 FITNESS FACILITY WIRING SPECIFICATIONS NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 CONTENTS: - Scope of work Summary - Equipment list - Technical specifications - Map of data

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual 255379 Rev. D0 1015 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification

More information

3M Wire Connectors. Reliable, high performing solutions for every wire connecting application. 3Innovation

3M Wire Connectors. Reliable, high performing solutions for every wire connecting application. 3Innovation 3M Wire Connectors Reliable, high performing solutions for every wire connecting application. 3Innovation SAVE TIME, REDUCE INVENTORY YOU CAN NEVER BE TOO WELL-CONNECTED ON THE JOB The best connectors

More information

Canopy Surge. User Manual

Canopy Surge. User Manual Canopy Surge Suppressor User Manual SS00-UM-en Issue 2 May 2003 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A Notices Safety Precautions: Before beginning your installation, please read

More information

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE 8.1 SYSTEM 8.1.1 Armoured, screened underground cables are used for control communication in electrified areas to limit induction effect. 8.2

More information

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices White Paper April 2012 Document: 327216-001 INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,

More information

Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600

Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600 Balun Activo - BALUN_ACT Características Single Channel Active Video Transmitter Full-motion color video signal up to 3900ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission

More information

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR

More information

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1 Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader

More information

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION TÜRK TELEKOMÜNİKASYON KASYON A.Ş. DIRECTORSHIP OF OPERATION AND MAINTENANCE Operation Directorate of Access Networks INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION ANKARA 2008 CONTENTS 1.

More information

Product Data Sheet 3M Mini-Clamp II Plug and Socket Wiremount Connectors

Product Data Sheet 3M Mini-Clamp II Plug and Socket Wiremount Connectors PD-0050 Product Data Sheet 3M Mini-Clamp II Plug and Socket Wiremount Connectors Page: 1 of 10 Table of Contents 1.0 SCOPE...2 2.0 PRODUCTS TESTED...2 2.1 Cables Tested...3 3.0 GENERAL CONDITIONS...4 3.1

More information

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT

More information

How Enhanced DSL Technologies Optimize the Last Copper Mile By John Williams

How Enhanced DSL Technologies Optimize the Last Copper Mile By John Williams White Paper How Enhanced DSL Technologies Optimize the Last Copper Mile By John Williams As broadband speeds increase to support the connected home, a debate continues over which type of network architecture

More information

MACTek Corporation. USB HART Interface. Users Manual

MACTek Corporation. USB HART Interface. Users Manual MACTek Corporation USB HART Interface DM01003100AA February, 2003 LIMITED WARRANTY VIATOR Interface for HART MACTek Corporation warrants this Interface and all of its component against defects in materials

More information

Intel System Engineers Documents. DSL General Overview

Intel System Engineers Documents. DSL General Overview Intel System Engineers Documents DSL General Overview Alex Lattanzi SC LAR Whatt IIs Brroadband? Broadband describes a number of different technologies that deliver digital data to homes and businesses

More information

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com 1080P Extender for HDMI over one CAT5 GTV-HDBT-CAT5 User Manual gefentv.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:

More information

Solar Mounting System

Solar Mounting System Xiamen Antai New Energy Tech.Co., Ltd Installation Manual Antai Rail Solar Mounting System (Flat Roof Solution) Version 1.1 Office Add: 508#, North Tower, Guangxia Building Huli Torch Hi-tech Zone, Xiamen,

More information

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller BLZPTS-1 NOVEMBER 19, 2013 TS350 TS752 BLPS PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller DESCRIPTION The BLPS, TS350

More information

Tina 2A/B Adaptor unit

Tina 2A/B Adaptor unit Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Load Cell Amplifier Module. Instruction Manual LCA210-000

Load Cell Amplifier Module. Instruction Manual LCA210-000 Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4

More information

HDSL Basics. HDSL Basics. Introduction. HDSL Overview

HDSL Basics. HDSL Basics. Introduction. HDSL Overview 1 Introduction Providing T1 service is a competitive race, and High-bit-rate Digital Subscriber Line () is quickly emerging as the ideal solution to remain a step ahead. Currently touted as repeaterless

More information

3M Dynatel Triple Play Customer Service Test Set INS970

3M Dynatel Triple Play Customer Service Test Set INS970 3M Dynatel Triple Play Customer Service Test Set INS970 Product Description Application The 3M Dynatel Triple Play Customer Service Test Set INS970 has been designed for the Customer Service or Installation

More information

Chapter 1. Introduction. 1.1 Research Motivation and Objective

Chapter 1. Introduction. 1.1 Research Motivation and Objective Chapter 1 Introduction 1.1 Research Motivation and Objective With the recent rapid growth of high-speed Digital Subscriber Line (DSL) access subscriptions, there is a high demand in the telecommunication

More information

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Requirements for the Attachment of Communication Cable Facilities on PPL Poles Page 99 of 137 Requirements for the Attachment of Communication Cable Facilities on Replaces: URS-3002 URS-3004 URS-101C-304 A-157649 Page 100 of 137 Reference Notes for Drawings: General 1. The term communication

More information

BIS Automation Engine

BIS Automation Engine BIS Automation Engine Installation manual en English BIS Automation Engine en Table of Contents Legal 5. Trademarks 5. Software License Agreement 5.. Limited Warranty 5.. Remedy 6 Introduction 7. About

More information

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide VOT-320 VOT-320V0xxL VOT-320V0xxH en Quick Installation Guide VOT-320 Table of Contents en 3 Table of Contents 1 General information 4 2 Parts included 5 3 Unpacking 6 4 Installing and connecting 7 4.1

More information