Information about the T9 beam line and experimental facilities



Similar documents
07 - Cherenkov and transition radiation detectors

Results from first tests of TRD prototypes for CBM. DPG Frühjahrstagung Münster 2011 Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

Cathode Ray Tube. Introduction. Functional principle

Event viewer for HRS-L

A Guide to Detectors Particle Physics Masterclass. M. van Dijk

Characterisation of the Timepix Chip for the LHCb VELO Upgrade

The OPERA Emulsions. Jan Lenkeit. Hamburg Student Seminar, 12 June Institut für Experimentalphysik Forschungsgruppe Neutrinophysik

ATOMS: ATOMIC STRUCTURE QUESTIONS AND ANSWERS

Proton tracking for medical imaging and dosimetry

MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca

Particle ID Distinguishing Particles. We have decided now to identify the particle species by a bar code

Track Trigger and Modules For the HLT

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Cosmic Ray Astrophysics with AMS-02 Daniel Haas - Université de Genève on behalf of the AMS collaboration

The accurate calibration of all detectors is crucial for the subsequent data

An option for the SHiP Muon Detector: Scintillator bars with WLS fibers and SiPMs readout

Calorimetry in particle physics experiments

ISTITUTO NAZIONALE DI FISICA NUCLEARE

The LHCb Tracking System. Jeroen van Hunen

Silicon Sensors for CMS Tracker at High-Luminosity Environment - Challenges in particle detection -

Tracking systems in HEP:

Physics 30 Worksheet # 14: Michelson Experiment

The TOTEM experiment at the LHC: results and perspective

HMS/SOS Tracking Code Enhancement

Introduction to Geiger Counters

Digital vs. Analogue Control Systems

Development of on line monitor detectors used for clinical routine in proton and ion therapy

Comparisons between 2003 CMS ECAL TB data and a Geant 4 MC

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Chapter 22: Electric motors and electromagnetic induction

Radiation Strip Thickness Measurement Systems

Status and Prospects of HARP. Malcolm Ellis On behalf of the HARP Collaboration NuFact02 Imperial College, July 2002

T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades

Precision Tracking Test Beams at the DESY-II Synchrotron. Simon Spannagel DPG 2014 T88.7 Mainz,

Cross section, Flux, Luminosity, Scattering Rates

(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier

Operation and Performance of the CMS Silicon Tracker

AS COMPETITION PAPER 2008

Atomic and Nuclear Physics Laboratory (Physics 4780)

High Energy Physics. Lecture 4 More kinematics and a picture show of particle collisions

Synthetic Sensing: Proximity / Distance Sensors

The Existence of a Neutron

Discovery of neutrino oscillations

CMS Tracker module / hybrid tests and DAQ development for the HL-LHC

(3) Interaction of high energy photons with matter

Coating Technology: Evaporation Vs Sputtering

AP2 Magnetism. (c) Explain why the magnetic field does no work on the particle as it moves in its circular path.

POSSIBL-E EXPERIMENTS ON THE 200-GeV ACCELERATOR. A. D. Krisch University of Michigan. R. Serber Columbia University.

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Development of the electromagnetic calorimeter waveform digitizers for the Fermilab Muon g-2 experiment

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

AC coupled pitch adapters for silicon strip detectors

Does Quantum Mechanics Make Sense? Size

UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics

OPTICAL FIBERS INTRODUCTION

Cyclotron Centre in Poland and 2D thermoluminescence dosimetry

Graphical displays are generally of two types: vector displays and raster displays. Vector displays

PoS(TIPP2014)028. Development of the upgraded LHCf calorimeter with Gd 2 SiO 5 (GSO) scintillators

CMS Tracking Performance Results from early LHC Running

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Part 4 fitting with energy loss and multiple scattering non gaussian uncertainties outliers

THE CMS PIXEL DETECTOR: FROM PRODUCTION TO COMMISSIONING

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

PrHEP JHW2002. Experiments on high energy reactions in the diffractive regime at LHC. 1. Introduction. Twenty-sixth Johns Hopkins Workshop

Candidate Number. General Certificate of Education Advanced Level Examination June 2012

Simulation of Neutron Backgrounds from the ILC Extraction Line Beam Dump. Siva Darbha. Office of Science, SULI Program. University of Toronto

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

Monday 11 June 2012 Afternoon

Theremino System Theremino Spectrometer Technology

Radioactivity III: Measurement of Half Life.

Jet Reconstruction in CMS using Charged Tracks only

Development of Radiation Resistant Quadrupoles Based on High Temperature Superconductors for the Fragment Separator

Conceptual: 1, 3, 5, 6, 8, 16, 18, 19. Problems: 4, 6, 8, 11, 16, 20, 23, 27, 34, 41, 45, 56, 60, 65. Conceptual Questions

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

World-first Proton Pencil Beam Scanning System with FDA Clearance

Zero Degree Extraction using an Electrostatic Separator

1. Units of a magnetic field might be: A. C m/s B. C s/m C. C/kg D. kg/c s E. N/C m ans: D

Hadro-Production Experiments: Impact on T2K and LBNE

1. The diagram below represents magnetic lines of force within a region of space.

A.Besson, IPHC-Strasbourg

FDTD Analysis of Site Free Space VSWR in Test Site Used for Disturbance Measurement above 1 GHz

Electron Muon Ranger (EMR) Software Development

Physics 441/2: Transmission Electron Microscope

Relativistic kinematics basic energy, mass and momentum units, Lorents force, track bending, sagitta. First accelerator: cathode ray tube

AS PHYSICS (7407/1) Paper 1. Specimen 2014 Morning Time allowed: 1 hour 30 minutes. SPECIMEN MATERIAL v1.1

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Physics 111 Homework Solutions Week #9 - Tuesday

Energy Deposition in MICE Absorbers and Coils

The Models of the Atom

THE DØ Luminosity Monitor (LM) consists of two array of

Construction of an Alpha- Beta and Gamma-Sensitive Radiation Detector on the Basis of a Low-Cost PIN-Diode

The Three Heat Transfer Modes in Reflow Soldering

Vacuum Evaporation Recap

View of ΣIGMA TM (Ref. 1)

GAMMA-RAY SPECTRA REFERENCES

Lectures about XRF (X-Ray Fluorescence)

Transcription:

Information about the T9 beam line and experimental facilities The incoming proton beam from the PS accelerator impinges on the North target and thus produces the particles for the T9 beam line. The collisions of the protons with the target can provide a variety of particles, such as electrons, positrons, muons, pions, kaons and (anti-)protons. The T9 beam line, used for the experiment is therefore a mixed hadron and electron beam and can transport either positively or negatively charged particles with momenta between 0.5 GeV and 10 GeV. The beam is delivered uniformly in time over a burst of 0.4 seconds. Depending on scheduling, such a burst is provided typically once or twice per 15 seconds. The maximum particle rate per burst of 10 6 is achieved for a 10 GeV/c positive beam, but drops for lower energies. For negative beams the rates are typically lower, meaning the bursts contain fewer particles. The beam travels approximately 55m before it enters the experimental area. The experiment will take place in an area of about 5 m by 12 m, containing a number of detectors, which are fixed, along with devices that can be changed or added. They are used to measure and analyse the properties of the beam and its composition. All available apparatus are listed in this document. Additionally it is possible to install devices that are brought by your team in the experimental area. However please note, that CERN cannot guarantee the installation of the suggested devices. Each request has to be reviewed individually. The installation of combustible material (e.g. wood) is not possible for safety reasons. It is also not possible to expose any organic material to the beam. The fixed setup of the beam line (for explanations, see below) Target 1

The primary beam, coming from the PS accelerator impinges on a target before it enters the secondary T9 beam line area. There are different target heads available, allowing different electron components of the beam. The core of the target is always light material (aluminium or beryllium). In some targets a tungsten plate enhances the electron content of the beam. Bending magnets Bending magnets are used in the beam line not only to guide the particles in a certain direction but also to choose the particles energies (between 0,5 GeV and 10GeV) by defining the magnet currents accordingly. Quadrupole magnets Quadrupole magnets are used to control the beam size and to focus or defocus the particles in the beam line. Their role is similar to the role of lenses in your camera. However, contrary to an optical lense, a quadrupole will focus the beam in one plane, but defocus the beam in the other plane. That means a horizontally focussing quadrupole defocusses vertically and vice versa. Collimator A collimator is a tool to filter the beam of particles. There are two collimators in the T9 beam line. The horizontal collimator changes the width of the momentum distribution of the beam depending on its opening. Thus it rejects particles that have either a higher or lower momentum than a pre-determined range. The vertical collimator on the other hand filters particles according to their initial angle on leaving the target. Any particle with a larger angle than selected is rejected. Scintillator counter (Scint) A scintillator counter consists of a scintillator coupled to a sensitive photomultiplier. Scintillation is the light produced when charged particles pass through certain materials, such as certain plastics with specific additives. The scintillation light can be detected by photomultipliers. The photomultiplier tube transforms the incoming light emitted by the scintillator into an electrical signal and amplifies it. One scintillator counter is part of the fixed setup of the beam line. Two additional scintillators are readily available for installation in the experiment. You can for example measure the time it takes the particles to travel from one scintillator to another or simply count the arriving particles. 2

Delay Wire Chamber (DWC) This tracking device is an evolution of the multiwire proportional chamber (MWPC), developed at CERN by Georges Charpak. Where the MWPC detects the position of a charged particle by indicating which wire was closest to the particle position, the delay wire chamber improves the position resolution by also measuring the time between the particle passage and delay of the chamber signal which is measured via a delay line. The delay measures the distance between the particle and the wire. The dimensions are 10x10cm 2 and the position resolutions of 100 to 200 microns can be achieved. However, the chamber can only measure one particle inside a certain time window. One DWC is part of the fixed setup of the beam line. Two additional DWCs can easily be installed for the experiment, if required. Cherenkov counter Nothing is faster than the speed of light in vacuum. However in other media, such as certain gasses, the velocity of particles can exceed the velocity of light in that medium. If that s the case, the particles emit so called Cherenkov light. By adjusting the pressure of the gas, the velocity threshold of the particles emitting Cherenkov light can be chosen. Since the momentum of all traversing particles is preselected, the different velocities can be assigned to different particle masses and thus different types of particles. Electrons will in practice always emit light in any gas, contrary to the other particles. Depending on the choice of gas, in a given energy range, a discrimination between electrons, pions and heavier particles (mostly kaons or protons) may be possible. Two Cherenkov counters are part of the fixed setup, each consisting of a Cherenkov threshold selector and a photomultiplier. Additional to the pressure of the gas, you can choose between certain gasses like carbon dioxide, helium, argon and nitrogen, according to what particles you would like to detect. If you choose not to use the Cherenkov counter in your experiment, it will remain on the beam but can be emptied, so that it won t interfere with the properties of the beam. Optional additional devices Timepix detector Timepix is a hybrid pixel detector developed by the Medipix2 Collaboration. It contains 65,000 square pixels of 55 µm pitch, with a 300 µm thick silicon diode sensor that detects ionising radiation. The chip can deliver up to 1000 frames per second. Timepix can be operated in time-over-threshold (ToT) mode to measure the energy of detected particles, or time-of-arrival (ToA) mode to distinguish between particles and/or reconstruct tracks of particles. Certain charged particle species can also be identified by the morphology and energy of their interaction with the sensor. 3

109 Cd (γ) 90 Sr (β) Read-out ASIC Timepix 241 Am (α,γ) Sample ToA data from Timepix Top left: gamma photons (dots) Top right: beta particles (squiggles) Bottom left: mixed field of gammas (dots) and alphas (blobs) Lead Crystal Calorimeter A calorimeter is a detector that measures the energies and positions of impinging particles. An electron hitting the calorimeter for example will produce a fully contained electromagnetic shower thus depositing all its energy in the calorimeter and therefore allowing a very precise measurement of its energy. Although heavier particles produce a signal as well, the energy deposition is smaller than for electrons. By measuring the deposited energy, signals induced by electrons can be distinguished from those induced by muons hadrons (pions, kaons and protons), with a certain amount of overlap. Although sometimes used as a position detector, the determination of a particle s position is less precise. The calorimeters are 10x10x37cm 3 in dimensions, and 16 of them are available. Four-layer straw detector This tracking detector is made of many metal-coated tubes, called straws at ground potential filled with some specific gas. In the middle of each straw a very thin metal wire is stretched and put at a high positive voltage. Whenever a charged particle traverses the straw, the gas is ionised and the electrons will be attracted by the positive wire, where they will leave a signal. The number of the wire as well as the drift time (a measure for the distance) from the particle passage to the signal arrival time will provide a precise position measurement. Four layers will allow a precise measurement of the passage of the charged particles. Halo counter 4

The halo counter is a set of 4 scintillator counters that have a hole around the beam passage. Its purpose is to identify particles that are too far away from the beam axis. While a collimator filters the beam by rejecting particles with a larger angle immediately, the halo counter identifies them and thus makes it possible to choose to either reject them or flag them. That s useful e.g. for flagging particles, that interacted with a certain absorber and underwent scattering. BL4S Halo Counter opening can be adjusted between 1cm and 15cm. Multi-gap Resistive Plate Chamber The Multi-gap Resistive Plate Chamber (MRPC) is a gas detector that can be used in the detection of charged particles. Their main advantages are the excellent time resolution and high detection efficiency. There are two available detectors of 20 x 20 cm 2 active area. They consist of six gas gaps of 220 um as the detection element, delimited by inner glass sheets of 280 um. The time resolution of this detector is around 90 ps at flux rates under 2 khz/cm 2. The detectors have 24 readout strips; these are read on each side by an ultra-fast amplifier discriminator, the NINO ASIC. The MRPC could be installed at a known distance from a time reference system, for instance another MRPC, and their signals can be used to measure very precisely the time of flight of a particle. In addition the MRPCs can also provide information about the position of the particle in the XY plane with an accuracy of 10 mm. Absorbers An absorber is a plate of material that absorbs a fraction of the particles in the beam or degrades the momentum of particles of a specific type. Typical absorber materials are lead or tungsten, but other lighter materials can also be used (e.g. polyethylene). By using a lead absorber, electrons will lose a large amount of their energy in the lead whereas most of the hadrons cross the absorber essentially unobstructed. The electrons that have interacted with the absorber can then be flagged with a halo counter (see above). Muon Filter A muon filter is a special absorber in the form of a massive iron block. It will be installed by crane if needed. All particles of the beam travelling through the iron are absorbed completely, except of the muons. By installing a detector such as a 5

scintillator counter behind the muon filter, the muon content of the beam can be detected. MNP17 Magnet CERN s large, polarity-changeable, horizontal dipole magnet has a maximum field of 0.96 T over a length of 52cm. The gap height is 30 cm and the useful aperture width is 1m. The field can be varied by adjusting the current. This magnet can be installed inside the experimental area on request in order to determine the momentum of the particles. 6