NEW Self-contained Sensors PZ-G Series MEG POWER Long-range detection twice as far as conventional models ESY DJUSTMENT The front light-receiving indicator allows easy optical axis alignment ESY INSTLLTION one-touch mounting bracket makes screws unnecessary
Dramatically improved performance and ease-of-use MEG POWER High-Power Dual LED-type High-power thrubeam type PZ-G Detecting distance: m (.') times * longer detecting distance times * faster response speed * Compared with our conventional models -element red LED-type Thrubeam type PZ-G Reflective type PZ-G Detecting distance: m () Detecting distance: m (.') times * longer detecting distance times * faster response speed The high-intensity -element red LED has greatly improved the detecting distance. The bright beam spot makes it easy to align the optical axis. -element LED is used in upper-level fiber sensors because its wavelength can be easily observed by the human eye and the intensity change over time is small. * Compared with our conventional models Retro-reflective type PZ-G6 Detecting distance:.m (.') Self-contained Sensors PZ-G Series
ESY DJUSTMENT lignment indicator takes the guesswork out of long distance sensor setup Has your receiver been bumped out of alignment? How can you tell? Thrubeam PZ-G models feature a bright red LED indicator that alerts you the instant proper alignment has been obtained. This simple yet crucial feature allows you to troubleshoot setup and run-time issues quickly, before they can snowball into major problems. Laser Marked tags eliminate possible contamination ll information (model#, lot#, etc.) is laser marked directly onto the sensor housing. There are no labels, inks or paints to peel or chip off into your products. Easy-to-see blue trimmer Enhances operation efficiency ESY INSTLLTION One-Touch mounting brackets cut installation time Our unique one-touch brackets can save you and your customers considerable man-hours during installation or replacement. models models Slide it through Slide it through Just push until it clicks Just push until it clicks variety of mounting styles are available to adapt to your application. models models Can be attached with an M nut Can be attached with two M screws
Enhanced user-friendliness Standard M and M quick-disconnects make replacement easier The PZ-G features a standard pin-out, which allows it to be a drop-in replacement with existing wiring. Our oil-resistant cable ensures reliable operation in an oily environment In addition to the standard PVC cable, an oil-resistant PUR cable is available for use in harsh environments. type M connector type PUR cable PUR: Polyuretane 9 types of mounting brackets provide a variety of mounting methods bracket can be selected according to the installation conditions. 9 types, including a one-touch bracket, are available. ipolar output (NPN+PNP) compatible with any input device models feature bipolar outputs (NPN and PNP), eliminating the need to stock sensors for both outputs. rown (Pin) DC V Sensor main circuit Overcurrent protection circuit lack (Pin ) White (Pin ) PNP control output NPN control output lue (Pin ) V ipolar output type PZ-G**(C) M connector The mounting brackets shown above are only part of the lineup. See page 7 for further details. The interference suppression function prevents interference from nearby units With thrubeam models, up to two sensors can be mounted in close proximity. Four sensors can be used by alternating the transmitter/ receiver position. High-speed targets can be detected at a response speed of up to µs high-speed response of up to µs, twice as fast as our conventional models, ensures detection on a high-speed line. The high power ensures stable detection. mbient light Different frequency beam Differentiating the number of sheets The different frequency function automatically shifts the emission cycle if ambient light is received by the receiver.
Model features models models Thrubeam High-power PZ-G The long-range high-power beam makes it easy to align the optical axis Standard PZ-G Long-range detection m (.') Long-range detection m () High-power dual IR LED lignment Indicator Clearly indicates when emitter/receiver are properly aligned. High-intensity -element red LED lignment Indicator Clearly indicates when emitter/receiver are properly aligned. Reflective The visible spot makes it easy to align the optical axis Thrubea Diffuse reflective PZ-G (long-range) PZ-G (short-range) Narrow-view reflective type PZ-G Definite reflective type PZ-G High-intensity -element red LED Long-range detection m (.') Short-range detection mm (.") High-intensity -element red LED Short-range detection mm (7.7") Spot diameter of approx. mm (.") at a detecting distance of mm (.9") High-intensity -element red LED Spot diameter of approx. mm (.") at a detecting distance of mm (.") Detecting distance of to mm (." to.77") Retro-reflective High-power long-range detection Standard PZ-G6 (with P. R. O. function) Transparent object detection type PZ-G6 Long-range detection. to. m (.' to.') (When using R-L) Detecting distance. to m (.' to.') (When using R-L) Single IR LED High-intensity -element red LED P.R.O. function The P. R. O. function* cancels direct reflections from metallic or mirror surfaced targets, allowing the PZ-G to reliably detect metal targets. * Polarized Reflection Optics DEX circuit The PZ-G employs a DEX circuit* (patented) that greatly amplifies the slight light attenuation caused by transparent targets ensuring stable detection. * Difference Expansion
Sensor head lineup / Model variations Sensor head lineup Type Thrubeam Reflective Retroreflective** Standard Diffuse reflective long-range Diffuse reflective short-range Narrowview reflective Definite reflective Highpower Longrange (with P. R. O. function) Transparent object detection Design models mm (7.7") models Detecting distance m (.') mm (.") m () to mm (." to.77") * Cable sold separately for connector models / pigtail quick disconnect models. ** Reflector sold separately for retro-reflective models. m (.'). to. m (.' to.') (when using R-L). to m (.' to.') (when using R-L) Model variations Light source NPN PNP ipolar (LED) NPN+PNP Cable* PZ-GN PZ-GP Cable (m ) PZ-GCN PZ-GCP PZ-GEN PZ-GEP Red M pigtail quick disconnect NEW PZ-G Cable (m ) PZ-GC M connector PZ-GN PZ-GP Cable (m ) PZ-GCN PZ-GCP PZ-GEN PZ-GEP Infrared x M pigtail quick disconnect NEW PZ-G Cable (m ) PZ-GC M connector PZ-GN PZ-GP Cable (m ) PZ-GCN PZ-GCP PZ-GEN PZ-GEP M pigtail quick disconnect NEW PZ-G Cable (m ) PZ-GC M connector PZ-GN PZ-GP Cable (m ) PZ-GCN PZ-GCP M pigtail quick PZ-GEN PZ-GEP Red disconnect NEW PZ-G Cable (m ) PZ-GC M connector PZ-GN PZ-GP Cable (m ) PZ-GCN PZ-GCP PZ-GEN PZ-GEP M pigtail quick disconnect NEW PZ-G Cable (m ) PZ-GC M connector PZ-GN PZ-GP Cable (m ) PZ-GCN PZ-GCP PZ-GEN PZ-GEP M pigtail quick disconnect NEW PZ-G Cable (m ) PZ-GC M connector Red PZ-G6N PZ-G6P Cable (m ) PZ-G6CN PZ-G6CP PZ-G6EN PZ-G6EP M pigtail quick disconnect NEW PZ-G6 Cable (m ) PZ-G6C M connector PZ-G6N PZ-G6P Cable (m ) PZ-G6CN PZ-G6CP PZ-G6EN PZ-G6EP Infrared M pigtail quick disconnect NEW PZ-G6 Cable (m ) PZ-G6C M connector Model variations PZ-G Reference 6 6 Detection method Reference description Reference Reference letter description Detection method Details letter Details Cable Output Thrubeam type Reflective type Retro-reflective type Standard High-power Diffuse reflective long range Diffuse reflective short range Narrow-view Definite reflective Long range (with P. R. O. function) Transparent object detection (without P. R. O. function) N P CN CP EN EP C Details NEW NEW models models m cable with a loose wire end -mm." cable + M connector m cable with a loose wire end M connector NPN PNP NPN PNP NPN PNP ipolar (NPN+PNP) 6
Options rackets PZ- PZ- PZ-6 PZ- PZ- PZ- PZ- * PZ- and PZ- are plate-symmetrical PZ- is shown * PZ- and PZ- are plate-symmetrical PZ- is shown PZ- PZ- PZ- PZ- PZ- PZ- * PZ- and PZ- are plate-symmetrical PZ- is shown PZ- PZ- OP- (for PZ-/) PZ-S PZ-S 6 Thrubea L PZ- PZ- OP- (for PZ-//) PZ-S (L= to mm.7" to.9") PZ-S (L= to mm.7" to 7.7") models Model For use with:* Details* PZ- PZ- PZ-6 PZ- L-shaped mounting bracket (standard) L-shaped mounting bracket (small) L-shaped mounting bracket (protective) Side-mounting bracket (vertical L) PZ- Side-mounting bracket (vertical R) Cable models PZ- Side-mounting bracket (landscape L) PZ- PZ- PZ- Side-mounting bracket (landscape R) Landscape mounting bracket One-touch mounting bracket PZ- PZ- PZ- PZ- OP- Connector models (M L-shaped cable only) Cable models Connector models L-shaped mounting bracket Side-mounting bracket (vertical L) Side-mounting bracket (vertical R) One-touch mounting bracket Stopper for one-touch mounting brackets (PZ-/) (without an L-shaped bracket) ccessories M screw, P=.xL ( pieces) Stopper M screw, P=.xL ( pieces) Stopper * One piece is included. * Not applicable for threaded models. PZ-V/M mounting brackets other than specified in this table cannot be used for PZ-G Series. models Model For use with: Details* ccessories* PZ- PZ- L-shaped mounting bracket (standard) L-shaped mounting bracket (angle-adjustable) PZ- Cable models Side-mounting bracket (vertical) PZ-* Connector models One-touch mounting bracket OP- M nut ( pieces) * One piece is included (except OP-). * One M nut is supplied with threaded models. * When using PZ-, OP- attachment cannot be used. / models Model PZ-S PZ-S *One piece is included. For use with: Cable models Connector models Details* Free adjuster tool (L= to mm.7" to.9") pplicable mounting bracket: Side-mounting bracket PZ-,,,,,, " to 7.7") pplicable mounting bracket: Side-mounting bracket ccessories inding band ( pieces) Plate washer ( piece) Material Mounting bracket: SUS Screw: Stainless Mounting bracket: SUS Stopper: SUS, Polyacetal Mounting bracket: SUS Screw: Stainless Mounting bracket: SUS Stopper: SUS, Polyacetal SUS, Polyacetal Material SUS SUS SUS ase: Polyacetal Slide: Glass-reinforced polyamide Glass-reinforced PT Material Shaft: SUS Plastic part: Polyamide Weight pprox. g pprox. g pprox. 9 g pprox. g pprox. g pprox. g pprox. g pprox. g pprox. g pprox. g pprox. g pprox. g pprox. g pprox. g Weight pprox. g pprox. g pprox. g pprox. g pprox. g Weight pprox. g pprox. 6 g 7
Options ttachments OP-6 ( sets) OP- ( sets) OP-7 ( sets) OP- ( pieces) OP-9 ( pieces) Model OP-6 OP-* OP-7 OP- OP-9 For use with: Description Number included Thrubeam ( models) ttachment (for attaching a slit or a polarization filter) sets Thrubeam (threaded models) ttachment (for attaching a slit or a polarization filter) sets Thrubeam (square/threaded models) Slit (. mm.", mm.", mm.") sets* Thrubeam (red LED models) Polarization filter (for the red LED type) pieces Thrubeam (red IR LED models) Polarization filter (for the red IR LED type) pieces* * OP- cannot be attached when using PZ- one-touch mounting bracket. * For the PZ-G, OP-7 includes sets for the transmitting points and receiving point. Material Polyacetal (POM) Polyacetal (POM) Polyvinyl chloride (PVC) Triacetate (TC) Polyvinyl alcohol (PV) cetate plastic Weight pprox. g pprox. g pprox. g pprox. g pprox. g Specifications when an attachment is used Sensor model PZ-G PZ-G Slit (mm inch) Polarization filter Detecting distance (m ft). x (." x.") (.') x (." x."). (.') x (." x.") (6.') ttached* 9 (9.'). x (." x.") ttached*. (.6') x (." x.) ttached*. (.9') x (." x."). x (." x.") x (." x.") x (." x."). x (." x.") x (." x.") x (." x.") ttached* ttached* ttached* ttached* ttached* * When attaching to make the polarization direction of the transmitter and the receiver same. (9.'). (.'). (.') (.') (9.') (.') () (6.') [ Usage example ] Suppressing interference between two thrubeam sensors Interference between thrubeam sensors can be suppressed with polarization Direction filters. polarization filter's characteristic Direction depends on the direction and notch in Polarization filter which it is set. If the polarization direction of the filters attached to the transmitter and the receiver is the same, the beam can be received. If the direction of the filter is changed by 9 degrees, however, the beam cannot be received. Using this restriction, interference can be suppressed with polarization filters as shown. [ Usage example ] Suppressing interference between four thrubeam-type sensors With another set of sensors set as in Usage Example, interference between four sensors can be suppressed by alternating the positions of the transmitters and the receivers. e sure to pay attention to the direction of the notches on the filters. * Remove the protective sheets on both sides of the polarization filter before use. * djust the sensitivity if interference occurs even with polarization filters. Reflectors OP-9 OP-966 (R-) R- OP- Model OP-9 OP-966 (R-) R- OP- For use with: Retro-reflective models Detecting distance (m ft) PZ-G6 Long-range. to. (.' to.'). to.9 (.' to 9.'). to. (.' to.'). to.7 (.' to.') PZ-G6 Transparent object detection. to (.' to.'). to. (.' to.'). to. (.' to.6') Description Reflector (R-L) Reflector (R-) Reflector (R-) Reflective tape Number included piece Material Reflective area: crylic, ase: S Reflective area: crylic, ase: S Reflective area: crylic, ase: S Surface: crylic, Cube: Polycarbonate Weight pprox. g pprox. g pprox. g pprox. g
Cables / Input/output circuits Connector cables M: Straight PVC M: Straight PUR M: L-shaped PVC M: L-shaped PUR Model Cable material Description Sensor connection Opposite connection Connector size Design Connector size Design Cable length (m ft) Weight OP-76 OP-76 OP-97 OP-9 OP-99 OP- OP- OP- OP- OP-6 OP-9 OP- OP-7 OP- PVC PUR Connector - loose wires Connector - connector Connector - loose wires Connector - connector M M M M M M M M M M M M M M Straight Loose wires Straight Loose wires L-shaped Loose wires Straight M Straight Straight Loose wires Straight Loose wires L-shaped Loose wires L-shaped Loose wires Straight M Straight L-shaped M Straight Straight M Straight Straight M Straight L-shaped M Straight L-shaped M Straight () (.') () () () (.') () (.') () () () (6.') () (6.') pprox. g pprox. g pprox. g pprox. g pprox. 6 g pprox. g pprox. 6 g pprox. g pprox. 7 g pprox. 7 g pprox. g pprox. 6 g pprox. g pprox. 7 g * One piece is included. M: Straight PVC M: Straight PUR M: L-shaped PVC M connector Model Cable material Description Sensor connection Opposite connection Connector size Design Connector size Design Cable length (m ft) Weight OP-77 OP- OP-77 OP- OP- OP- OP-6 OP-7 OP- PVC PUR Connector - loose wires Connector - connector Connector - loose wires Connector - connector M M M M M M M M M Straight Loose wires Straight Loose wires L-shaped Loose wires Straight M Straight Straight M Straight Straight Loose wires Straight Loose wires Straight M Straight Straight M Straight () (.') () () (6.') () (.') () (6.') pprox. 6 g pprox. g pprox. 6 g pprox. 7 g pprox. g pprox. 7 g pprox. g pprox. 9 g pprox. 7 g * One piece is included. Input/output circuits Thrubeam transmitter PZ-G* NPN output (thrubeam receiver, reflective, retro-reflective) PZ-G**N Sensor main circuit rown (Pin ) lue (Pin ) DC-V PZ-G*CN PZ-G*CP V M connector PZ-G*EN PZ-G*EP PZ-G*C Sensor main circuit Overcurrent protection circuit rown (Pin ) lack (Pin ) lue (Pin ) DC-V PNP control output V PZ-G**CN M connector PZ-G**EN PNP output (thrubeam receiver, reflective, retro-reflective) PZ-G**P Sensor main circuit Overcurrent protection circuit rown (Pin ) lack (Pin ) lue (Pin ) DC-V PNP control output V PZ-G**CP M connector PZ-G**EP ipolar output (thrubeam receiver, reflective, retro-reflective) PZ-G** Sensor main circuit Overcurrent protection circuit rown (Pin ) lack (Pin ) White (Pin ) lue (Pin ) DC-V PNP control output NPN control output V M connector PZ-G**C 9
Characteristics excess gain vs. detecting distance (Typical) PZ-G PZ-G PZ-G PZ-G Excess gain X Excess gain X X X Excess gain Excess gain 6.'.' 9.' Detecting distance (m / ft).'.......' 9.'.' 6'.6'.'.9'.' 9.'.9" 7.7".".7" 6 7 9.69".6" 7.6" Detecting distance (m / ft) Detecting distance (m / ft) Detecting distance (mm / inch) PZ-G PZ-G PZ-G6 Reflective tape PZ-G6 R-L R- R- R-L R- R- Excess gain X Excess gain X Excess gain X Excess gain X 6.9" 7.7".".7" 9.69" 7.6" Detecting distance (mm / inch) 6 7.9".79".".".97".6".76" Detecting distance (mm / inch) 6 7.' 9.'.' 6.' 9.7'.' 6.' Detecting distance (m / ft)....6'.'.9' Detecting distance (m / ft). Interference area (Typical) PZ-G PZ-G PZ-G PZ-G Distance Y (m / ft). Operating area....6'.9'.'.6'.6.'..'..7' Interference area.' 9.' Distance Y (m / ft)..' 9."." Operating area Operating area Operating..'." area.". 9.' 7.76".9" 6.6"..'.97".79". White." White.9"..9' mat." mat paper paper.9"..'.79"..6' Interference.9" Interference." Interference area area area....6....' 9.'.' 6'.7'.'.'.6'.'.9'.97".9".9" 7.7" 9."." Distance X (mm / inch) Distance Y (mm / inch) Distance Y (mm / inch) PZ-G Distance Y (mm / inch) Operating area White mat paper Interference area.97".9".9" 7.7" Distance X (mm / inch) 9.".".".".9".79".9".9"." Note: PZ-G/G6/G6 can be used while units are mounted in close proximity to each other without mutual interference. Parallel displacement of optical (Typical) PZ-G Slit. Slit. PZ-G Slit. Slit. PZ-G6 R- Reflective tape PZ-G6 Distance Y (mm / inch) 6 - - -6 Without slit Slit. - 6.'.' 9.'.".6".7" 7.7".' -7.7" -.7" -.6" -." Distance Y (m / ft) Without slit Slit...... -. -. -. -. -..' 9.'.'.'.9'.'.6' -.6' -.' -.9' - -.' 6' Distance Y (mm / inch) - - R-L R-.9".9".97" -.97" -.9" - -.9".' 9.'.' 6.' Distance Y (mm / inch) - - - R-L R- -...6..7'.'.'.6'..' R-..9'.".".79".9" -.9" -.79" -." -."
Optical axis angle (Typical) PZ-G(Lateral) PZ-G(Longitudal) PZ-G(Lateral) PZ-G(Longitudal).'.' 7.6'.'.' 9.' 9.' 9.'.'.'.' 9.' 6.' 6.'.' 6.' 7.6'.'.' 9.'.' 9.'.' 6.' - - -6 - - 6 Operating angle () - - -6 - - 6 Operating angle () - - -6 - - 6 Operating angle () - - -6 - - 6 Operating angle () Distance X (mm / inch) 9 7 6 - -6 - - 6 Operating angle () 9.7"."." 7.6".6" 9.69".7"." 7.7".9" Distance X (mm / inch) - -6 - - 6 Operating angle ()." 9." 7.7".9".9".97" Distance X (mm / inch) 6 6 - -6 - - 6 Operating angle () 7.7" 7.9" 6.".".7".9".".6".".79" Distance X (mm / inch) - -6 - - 6 Operating angle ().97".77".".".".9".79".9".9"." PZ-G6 (Sensor:Lateral) R-L R- R- Reflective tape 6.'.' 9.'.' PZ-G6 (Sensor:Longitudal) R-L R- R- Reflective tape 6.'.' 9.'.' PZ-G6 (Sensor:Lateral)....6.. R-L R- R-.9'.'.6'.'.'.7' PZ-G6 (Sensor:Longitudal)....6.. R-L R- R-.9'.'.6'.'.'.7' - - - - - - - - - - -6 - - 6-6 - - 6 Operating angle () Operating angle () Operating angle () Operating angle () Operating distance vs. detecting distance (Typical) PZ-G PZ-G PZ-G PZ-G Distance Y (mm / inch) - -.".79".9" -.9" -.79" - -." 6 7.7".7".6"." 9.7" Distance X (mm / inch) Distance Y (mm / inch) - -.7".".6" -.6" -." - -.7".97".9".9" 7.7" 9.".".7" Distance X (mm / inch) Distance Y (mm / inch) 6 - - -6 -.97".9".9" Distance X (mm / inch).".".6"." -." -.6" -." -." 7.7" Distance Y (mm / inch)...... -. -. -. -. -..9".79"."." Distance X (mm / inch).".".6"."." -. -. -. -. -..97"
Specifications Models Design Cable type Cable (m) M pigtail quick disconnect Cable (m) M connector Output NPN PNP NPN PNP NPN PNP NEW NEW ipolar (NPN+PNP) Standard Thrubeam High-power Long-range Diffuse Reflective Retro-reflective* Short-range Narrow-view reflective Definite reflective Long-range (with P.R.O. function) Transparent object detection PZ-GN PZ-GN PZ-GN PZ-GN PZ-GN PZ-GN PZ-G6N PZ-G6N PZ-GP PZ-GP PZ-GP PZ-GP PZ-GP PZ-GP PZ-G6P PZ-G6P PZ-GCN PZ-GCN PZ-GCN PZ-GCN PZ-GCN PZ-GCN PZ-G6CN PZ-G6CN PZ-GCP PZ-GCP PZ-GCP PZ-GCP PZ-GCP PZ-GCP PZ-G6CP PZ-G6CP PZ-GEN PZ-GEN PZ-GEN PZ-GEN PZ-GEN PZ-GEN PZ-G6EN PZ-G6EN PZ-GEP PZ-GEP PZ-GEP PZ-GEP PZ-GEP PZ-GEP PZ-G6EP PZ-G6EP PZ-G PZ-G PZ-G PZ-G PZ-G PZ-G PZ-G6 PZ-G6 PZ-GC PZ-GC PZ-GC PZ-GC PZ-GC PZ-GC PZ-G6C PZ-G6C Detecting distance* m () m (.') m mm (.') (.") (When detecting (When detecting x cm x cm (."x.") (.9" x.9") white paper) white paper) mm (7.7") to mm (." to.77"). to. m (." to.') (When R-L reflector is used). to m (." to.') (When R-L reflector is used) Spot diameter pprox. mm pprox. mm." dia.." dia. (t a detecting (t a detecting distance of distance of mm.9") mm.7") Light source Sensitivity adjustment Response time Operation mode Indicators (LED) Control output Protection circuit Rating Environmental resistance Power supply Current consumption Enclosure rating mbient light mbient temperature Relative humidity Vibration Shock Interference suppression Material Tightening torque ccessories* Weight Housing, M nut (threaded models only) Lens cover Trimmer Case connection Cable (cable models / pigtail quick disconnect models only) Connector (pigtail quick disconnect type only) Red LED T: Power (orange LED) R: Output (orange LED) Stable operation (green LED) Light receiving (red LED) T: m max. R: m max. Infrared LED x T: m max. R: m max. Up to units (When polarization filters are attached) Red LED -turn trimmer ( ) µs LIGHT-ON/DRK-ON (switch-selectable) Open collector output, V max., m max., Residual voltage: V max. Reversed polarity, overcurrent protection, surge absorber to VDC including Ripple ± % (P-P) IEC, IP67 / NEM: x, 6, / DIN: IP69K Incandescent lamp:, lux max., Sunlight:, lux max. - to C (- to F), No freezing to %, No condensation to Hz,. mm double amplitude in the X, Y, and Z directions, hours respectively m/s 6 times in the X, Y, and Z directions Polyarylate (PR) Output: Orange LED, Stable operation: Green LED Glass-fiber reinforced PT Glass-fiber reinforced polyamide (P) Polyvinyl chloride (PVC) m max. Up to units (with the automatic different frequency function) Screw: Steel, zinc-nickel plated, Packing: Nitrile-butadiene rubber (NR) rass-nickel plated, Polybutyleneterephthalate (PT), Polyvinyl chloride (PVC) models (Mounting hole part):. N m max. models (front M part):. N m max., (side slotted hole part):. N m max. Instruction manual, M nut x pieces (nut thrubeam type), M nut x piece (other threaded models) cable models: pprox. 6 g (Thrubeam-models transmitter: pprox. g) connector models: pprox. g M pigtail quick disconnect model: pprox. g cable models: pprox. 6 g (Thrubeam-models transmitter: pprox. g) connector models: pprox. g * Detecting distance at the maximum sensitivity. * Cable sold separately for connector models / pigtail quick disconnect models. Reflector sold separately for retro-reflective models. Infrared LED crylic (PMM) Polyarylate (PR)
Dimensions CD Download www.keyence.com Unit: mm inch Sensors (thrubeam type) PZ-GN/GP/GN/GP/GEN/GEP/GEN/GEP 7.." PZ-GCN/GCP/GCN/GCP.."." xmxp. Receiving point.."." 7.9..".9".7.79".7" Operation mode selector switch.6"..6".".."..6" 7.."..".9"." Light-receiving Indicator..7"."." ø.9 ø.", M pigtail quick disconnect: -Core x rown/lue/lack:.mm PZ-GEN/GEP/GEN/GEP Cable length : m 6.6" Pin arrangement ø ø." +V V..7" OUT." 7..".." 7.."..".".7" Receiving point.6".6"..6" Light-receiving Indicator.."." xmxp...".".." 7.9..".9".7.79".7"." 6.9.67".9.9" M Connector Operation mode selector switch.".6."..9" 9..9" +V V OUT 7..".." 7.." +V.."." 7..".." 7..".7" V.."." Transmitting point.6".6"..6" Transmitting point.6".6"..6".7"." xmxp...".."." xmxp. 7.9..".9"..79".7".."." ø.9 ø.", -Core x rown/lue:.mm."." 6.9.67".9.9" Cable length : m 6.6"...".79".7"..".".." 7.9..".9" Sensitivity adjustment trimmer..".6" Sensitivity adjustment trimmer..".6" 9..9" M Connector.6." +V V PZ-G/G." 7.9."..9"...9".7" R7."..9" Receiving.."." point." 6..7".6"...6"."."..9".7.6".6" 6..7". Center of.".9..7" M screw.9"." Light-receiving. Indicator M, P=.." R7 ø. ø.6",-core x rown/lue/lack/white:.mm Cable length : m 6.6".7.7" Operation mode selector switch."..77"." 7.9.7"..9"...9".7" R7.".9".. Transmitting."."." 6. point.7".6"...6".".7..9".".6".6" 6..7". Center of.9..".7" M screw.9".". * When the PZ-G transmits M, P=.." a beam, only the upper transmitting point emits ø.9 ø.",-core x rown/lue:.mm the beam. Cable length : m 6.6" R7..7" Sensitivity adjustment trimmer." 9..77" PZ-GC/GC." 7.9."..9"....7...9".9".7".7".7".7" Operation mode Sensitivity.".9" selector switch.".9" Receiving.... adjustment trimmer."."." Transmitting."." point." 6. 6. point.7".7".6".6".."..6"."..9".6"..7..".7.".6"."...9"." 9..6".6" 6...".6"..77" 6..7".".7".."..".9..7".".9..7".9".".7".9".".7" Light-receiving Center of. * When the PZ-GC transmits. Indicator M screw." a beam, only the upper Center of." transmitting point emits M screw M, P=. the beam. +V V M, P=. +V V OUTNPN OUTPNP R7 R7 M, P=. R7 R7." 7.9.7"..9" M, P=.
Dimensions Unit: mm inch Sensors (reflective / polarized retro-reflective type) PZ-GN/GP/GEN/GEP (////6/6) 7..".." 7..".."."." xmxp. Receiving point..".6".6"..6".."." Transmitting point 7.9..".9"..79".7"."..".6".7". ø.9 ø.",."." M pigtail quick disconnect: -Core x rown/lue/lack:.mm PZ-G?EN/G?EP (?:////6/6) Cable length : m 6.6" Operation mode selector switch Sensitivity adjustment trimmer ttachments (optional) OP-6PZ-G..".6 6."..".97" 6.".".." Center of.".". slit." OP-PZ-G Slit size. x."x.". x."x.". x."x." PZ-GCN/GCP (////6/6) 7..".." 7.." R7..".".7" Receiving point.6".6"..6" Transmitting point." xmxp..."..".".."."..9" R7.". Receiving point."." 6..7".6"..6"...".9".7.".6".6" 6..7". Center of.".7" M screw Transmitting point M, P=. 7.9..".9"..79".7"." 6.9.67".9.9" PZ-G (////6/6) 7.9..".9"..7".9".." M Connector.9..9".".." ø. ø.6",-core x rown/lue/lack/white:.mm Cable length : m 6.6" PZ-GC (////6/6)..7"." Receiving point.."." 6..7".6"...6"..".9".7.".6".6" 6..7". Center of.".7" M screw Transmitting point M, P=. R7 R7."..7"." ø ø." +V V OUT 7.9..".9"..7".9".."..7"..7"."." M, P=.."..6.9..9"..".7"." Operation mode selector switch Sensitivity adjustment trimmer."..6" 9..9" +V V OUT Operation mode selector switch Sensitivity adjustment trimmer 6." 9..77" Operation mode selector switch Sensitivity adjustment trimmer 6." 9..77" +V V OUT (NPN) OUT (PNP) 9..76"..6"..9" 6." 6." Center of slit.." Ø6 Ø.6" Reflectors (optional) OP-9 (R-L) 7 6."." OP-966 (R-).".6" R- 6.".".".9".9".".7."..9" 7..69"."." x Ø.6." x Ø. OP- (reflective tape).".".6 7.".".".."."..6.6"." x M..".6.".."." t=.7." 9.9" x Ø.." x Ø..."." Slit size. x."x.". x."x.". x."x."..".."..".."."
CD Download www.keyence.com Unit: mm inch Mounting brackets / models (Optional) PZ- PZ- PZ-6..7"." 9."..."."..7".".7"..."." 7 7 7 7 7.6".".".".6"."."..."." 6. 6 6.." 9.".6"..".."."."."...6"."...6"." SUS t=.." SUS t=.."." 6.6"." 6..7".".69"..".."." 6.."." (9.)..".9".." 6." SUS t=.." PZ-/ 7.67".9".."...7".".6".".7." ()." 6 x Ø.." 6..6".".9".".7".9" PZ-." 7.67".69" 6...6"."."..".".".".6" 7.".9".7" 7.".".9"."..".".69".".." 6 x Ø.." 7.67" SUS t=.." *PZ- is shown. PZ- is a plane-symmetrical type. ()." SUS t=.."..7" PZ-/.7" 7..69" ()." PZ-..7".".7"..."." PZ-/.7" 7..69" ()." 6.."." 9."..".." 7 7.".6".6" 6. 9.".".".." 6. 9.".".".."...6".".." 7.76".." 7.76" SUS t=.." 6.7.66" *PZ- is shown. PZ- is a plane-symmetrical type...7".".9".".6" SUS t=..6" 6.7.66"..7"." *PZ- is shown. PZ- is a plane-symmetrical type..9".".6" SUS t=..6"
Dimensions Unit: mm inch Mounting brackets / models (Optional) PZ-..".7".6" 7 7."."..".6."." 9..."." 6.6"..".".9" ø. ø." ø. ø.9".6.6" SUS t=..6" OP- (One piece is supplied for PZ-/) When being mounted.."."...96".9" When assembling/disassembling 9..".9." PZ-PZ-GN When being mounted ø. ø."..6".6 6.".6".9.9". 6.."."..".."..".." When assembling/disassembling..7"..".7.". 7..".9" 9.." PZ-.7".6" 7 7.".".."..". 6.9".6".".." 7..76"..".".9" ø. ø." ø. ø.9".6.6" OP- (One piece is supplied for PZ-/) When being mounted.."."...96".9" When assembling/disassembling PZ-PZ-GCNOP-97 When being mounted.6 6.".6"..9.".9". ø..6" ø.".." 7..76" 67.7..67".6" 6.7 9..".6" 7.7." SUS t=..6" When assembling/disassembling. 7..".9"..7"..".7." 7.7.7" 6
CD Download www.keyence.com Unit: mm inch Mounting brackets / models (Optional) PZ- 6...6".".9."..6"..6".." 9.".7".." 7..".69" ø. ø.7" PZ- PZ-PZ-G..6.7..6.7.7".97".".7".97"."..".." 7.6." 7.." 9..."."." When being mounted 6.." 7.6.".." When being mounted 6.." 7.." 9. 6."." 6.." SUS t=.."..".".7."." PZ-.." 6.6".6" 6.6".6"..".." When assembling/disassembling When assembling/disassembling.6."...9".79" R..6.7"." to to.6"." to to.6"..6"..6" ø.6 ø." ø. ø.7"sus t=.." Mounting brackets / models / models (Optional) PZ-S/S LmmPZ-S LmmPZ-S..9" Ø." Ø.9" PZ-SPZ-PZ-GN 7..7" 6.."..9".." PZ- 7..69".9".."." L." x M P.7 6..".9".7.".9"..6" 7..69"..6"..6" ø. ø.7" 6."." Ø7 Ø." PZ-SPZ-PZ-GN.7".7..6".6" 6.." 7..6".9"..9".6"..7"."...6".7"." 6..6" SUS t=..".".9"." 6." Ø7 Ø." 6..".7.".9" OP- (One piece is supplied with threaded models) M,P=..6" PZ-SPZ-PZ-G. 6.9."."..".".7".7"..96".9."..7".".6"." 6..6".." 7
Dimensions CD Download www.keyence.com Unit: mm inch cable (optional) OP-76/76 6.7.6" ø9 ø." OP-97 6.6" 7.7." OP-9 6.7.6" ø9 ø." OP-99/ ø ø.9".."..9" OP-/ 6..6".." 6." ø ø.9" OP-76/OP-76 ø9. ø.7" 6.7." ø9 ø.".79" ø.7 ø.", x.mm 9 ø7 ø9."." ø."ø." ø.7 ø.", x.mm 6.7." ø9. ø.7" ø.7 ø.", x.mm 6.." ø9 ø." OP-99/OP- ø.7 ø.9", x.mm OP-/OP- ø.7 ø.9", x.mm 6.." Color rown White Color rown White lue lack Color rown White lue lack Color rown White M x lue lack lue lack OP-. 7.".6". ø.7 ø.9", x.mm..9".9" ø ø.9" OP-6.." 6..6" OP-7/.." 6..6" 6.".79" ø ø.9" ø ø.9" OP-7 OP- 7.6" ø.7 ø.9", x.mm..9" 6 ø.7 ø.9", x.mm 7.9.".".79" OP-9/.." OP-9 OP- 6.." M x Mx ø ø.9" ø ø.9" 6. Mx." ø. ø.7" M x ø ø. ø.9" ø.7". ø.7 ø.9", x.mm 7.9.".9" M connector cable (optional) OP-77/ ø ø.".7."." OP-77/.'OP- OP-77.." OP-/6 ø. ø.7".." ø Ø.".9.69" ø ø.7" ø ø.6", x.mm ø ø.6", x.mm OP-.'OP-6 ø.7 ø.9", x.mm Color rown White lue lack Color rown White Color rown White lue lack lue lack OP-/ ø ø." OP-7/ OP-7.9.69" 6.'OP- 6.." Mx ø. ø. ø.7" ø.7".9" ø.7 ø.9", x.mm 7.9.".7..".".9".77" OP-/ 6.'OP- ø ø.6", x.mm ø.6 ø ø.7" ø ø.7" ø." Mx
MEMO 9
Self-contained Photoelectric Sensors PZ-V Series Here's How ackground Suppression Model Unaffected by Color! Features Intelligent reflective type unaffected by a target's color or angle Digital display High-power custom red LED (Except for PZ-V7) High-intensity operation indicator PSD (Position-Sensitive Detector) The target distance is detected according to the angle of the reflected light beam. Unaffected by a highly reflective target background Stable detection of targets with colors and materials of varying reflectance Highly accurate detection of minute objects One-touch Fully-automatic calibration.p.r. circuit (utomatic Power Reinforcement) Stable detection is possible due to the.p.r. circuit which automatically adjusts the amount of light emitted according to the color and angle of the target. OFF ON Sensor head lineup Model Type djustment Configuration Detecting distance Connector Cable Intelligent reflective. Different frequency type uto ON OFF mm." mm.9" 9 mm." NPN PZ-V7 PZ-V7 PZ-V7 PZ-V7. PZ-V PZ-V PZ-V PZ-V. PZ-V PZ-V PZ-V PZ-V. PNP PZ-V7P PZ-V7P PZ-V7P PZ-VP PZ-VP PZ-VP PZ-VP. PZ-VP PZ-VP PZ-VP M connector M connector M connector m. m. m m m. m. m m m. m. m m.'.9'.'.9'.'.9' CLL TOLL FREE TO CONTCT YOUR LOCL OFFICE - - 9-6 KEYENCE CORPORTION OF MERIC Corporate Office Tice lvd., Woodcliff Lake, NJ 7677 Phone: -9- Fax: -9-99 E-mail: keyence@keyence.com Regional offices CO Denver IN Indianapolis MI Detroit NJ Woodcliff Lake OH Cincinnati SC Greenville L C C irmingham N.California Los ngeles FL G IL Tampa tlanta Chicago KS KY M Kansas City Louisville oston MI MN MO Grand Rapids Minneapolis St. Louis NY NC NC Rochester Charlotte Raleigh OH OR P Cleveland Portland Philadelphia TN TN TX Nashville Knoxville Dallas Specifications are subject to change without notice. www.keyence.com Fax: -9-99 V W Richmond Seattle KEYENCE CND INC. Head Office Phone: 9-696-997 Fax: 9-696- Montreal Phone: -69-7 Fax: -69-6 E-mail: keyencecanada@keyence.com KEYENCE MEXICO S.. DE C.V. Phone: +---79 Fax: +---997 E-mail: keyencemexico@keyence.com Copyright (c) 7 KEYENCE CORPORTION. ll rights reserved. PZG-K-C-E 69-6 Printed in Japan K-9 * 6 *