Operating Instructions for Model 750-749 Remote Scan Controller for Acton SP-750i Monochromator



Similar documents
History of Revisions. Ordering Information

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Newton Backup Utility User s Guide. for the Windows Operating System

Getting Started. rp5800, rp5700 and rp3000 Models

Using Windows CE Applications in the Pathfinder

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

MINIMUM TOOL REQUIREMENT FOR EPROM UPGRADE

8 Channel Status Input Panel model SIP-8

Mini Portable Reader (MPR) Model HS 5900L F

PDA Software Manual For the Windows CE and Mobile Operating Systems

Maintaining the Content Server

Hydras 3 LT Quick Start

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

SubCue Analyzer Software - Introduction

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

KI6501 Data Manager. Software User Manual

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

Welch Allyn Vital Signs Monitor 300 Series

EXCHANGING THE SIDEPANEL PC RC 2371 OF RPS35-2/-3/-4/32 CONTROL PANELS


USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks


Chlorophyll Content Meter. CCM-200 plus

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Setting Up the ZigBee Ethernet Gateway

MULTIFUNCTIONAL DIGITAL COLOR SYSTEMS / MULTIFUNCTIONAL DIGITAL SYSTEMS. Remote Scan driver Help

User's Guide DylosLogger Software Version 1.6

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

WinPFT File Transfer Utility (Catalog No ND7)

Centurion C4 Transfer Guide using C4 File Transfer Utility

Backup/Restore application

Modbus RTU (RS-485) TCP/IP (Ethernet)

1. Introduction... 3 Introduction Deal command... 13

HomeSeer Technologies. HomeSeer Technologies LLC 35 Constitution Dr, Suite C Bedford NH,

Optimod-DAB 6200 PC Remote Control Version 2.0 Software

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

User's Guide. Dosimeter Configuration Software ADR-1/60

Remote Access. Table Of Contents. Rev: 3.30, 8/03

Driver Pant 8 and antenna switcher Ant 8. User manual

32 Transferring Projects and Data

Control Performance Analyser 3.0. Installation Instruction

AUDITVIEW USER INSTRUCTIONS

Data Analysis Software

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

#65 4GHGTGPEG")WKFG #FXCPEGF"6GTOKPCN"5QHVYCTG 8GTUKQP"502 HQT"%QPVTQNNGT/#% Catalog # Rev.02

How To: Upload a Custom Tune to Your Predator or Trinity PREP:

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

GE Healthcare Life Sciences UNICORN Administration and Technical Manual

MFC6490CW Windows Network Connection Repair Instructions

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Tera Term Telnet. Introduction

Information Sheet IS13011A. VS Series - Recovering / Installing the Operating System. (For Software Version 4.x) Issue

Remote control software manual for soft starter DG[ Document code: I88.GB Remote control software manual page 1 DG[

Table of Contents Install a Printer Driver... 2 Print a Test Label... 9 Uninstall a Printer and Driver... 10

DUKANE Intelligent Assembly Solutions

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration

4-Channel Thermometer / Datalogger

Additional Guides. TETRIX Getting Started Guide NXT Brick Guide

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage procedures.

T3 Mux M13 Multiplexer

R ADVANCED MODEL-SETUP

User Guide Vodafone Mobile Wi-Fi R206-Z. Designed by Vodafone

CipherLab 5100 Time Attendance Utility Manual

SCS3205/4805 Quick Start Guide

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

AUDITVIEW USER INSTRUCTIONS

Programmer/Controller

ISHIDA BC Scale to Scale Communications

4 Backing Up and Restoring System Software

PRN_LOAD :22

AT-S99 and AT-S102 Version Management Software for the Converteon Media Converter Products. Software Release Notes

VisionMate Flat Bed Scanner 2D Tube Barcode Reader

Part Number Revision A, January Monitoring System Rack Configuration and Utilities Guide

PORTABLE DATA COLLECTION TERMINAL

ROCLINK for Windows Configuration Software

Software User Guide UG-461

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

User s Manual. Management Software for Inverter

Getting Started. HP Retail Systems

Lenovo IdeaCentre Q180 Series

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Winzer Corporation 1 Revision: 4.0

Ultra Thin Client TC-401 TC-402. Users s Guide

User Manual WatchPower

Global Water Instrumentation, Inc.

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

16.1 REQUIREMENTS AND INSTALLATION

GE Security. FHSD Monitor / Web Server user manual

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

SA-9600 Surface Area Software Manual

Computer Lane Monitor for Windows

Fanuc O4P-C Parameter and Macro Program Back-up and Restore Procedure

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual CROMLAWATCH. Data Logging Software. Version 1.6. For use with Color Sensors CROMLAVIEW CR100 CROMLAVIEW CR200 CROMLAVIEW CR210

EZ DUPE DVD/CD Duplicator

Sartorius YAD01IS Win

Tutorial for MPLAB Starter Kit for PIC18F

LT1 Tune Kit Quick Start Guide

Transcription:

15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.piacton.com Operating Instructions for Model 750-749 Remote Scan Controller for Acton SP-750i Monochromator Ver 2.0 1

General: The Acton Model 750-749 is a Remote Scan controller for the Acton 750i monochromator/spectrograph. Functions include GOTO for rapidly moving the monochromator to a specific center wavelength, scanning of wavelengths, indexing of gratings, selecting the installed grating turret and setting the slit widths for monochromators with motorized slits. The controller consists of the HP-48G graphics calculator with RS-232 interface and Princeton Instruments generated scan controls software. The controller is programmed with all the instrument functions described above displayed as convenient menu items, with simple keystrokes enabling any of the scan functions to be performed. Connection and Initialization: The scan control software for the 750-749 is installed at the factory and the 750-749 is ready for use as it is shipped. A copy of the software is provided on disk and may be reloaded into the HP48G using a PC and the cables provided if it is ever necessary to do so. This procedure is described in the last section of this manual. The controller is connected to the monochromator using eh cable provided through the standard RS-232 port on the monochromator rear panel. The controller may be used with any Acton 300i, 500i or 750i monochromator; the controller is not assigned to a specific unit. Power should be switched on the Acton monochromator first. After the monochromator has initialized, the 750-749 controller should be turned on. Battery Power Management: If the controller is not used for several minutes, the LCD screen will turn off to save battery power. If this happens, press the on button in the lower left corner of the keyboard to return to the menu you were using. Operation of the 750-749 Controller: After the Acton monochromator is turned on and initialized and the 750-749 controller is turned on, the following menu will be shown at the bottom of the LCD screen: SP750 UTIL 2

If this menu is not shown, press the right arrow key (green) followed by the library key (2) and press the key under the box labeled SP750. This should bring up the menu shown above. This menu indicates there are two main selections for operation: SP750 selects the menu for normal SP300I/500I/750K OPERATION. UTIL selects lesser used utility functions for the monochromator. Pressing the function key below SP750 brings up the following menu. GOTO SCAN GRAT TURR DIVTR And pressing the NXT key displays the remaining functions of this menu SLITS and QUIT. GOTO: Press the functions key below the GOTO command. The following screen is shown: Go to: Enter wavelength < Key in the desired wavelength in nm (up to two digits after the decimal) and press the ENTER key. The monochromator will move quickly to the selected wavelength and display this wavelength. SCAN: Press the function key below the SCAN command. The following screen is shown: Scan To: Enter wavelength < Key in the desired wavelength in nm and press the ENTER KEY. The monochromator will scan at the constant rate previously selected to the wavelength just selected. SPEED: Press the function key below the SPEED command. The following screen is shown: Scan Rate: Enter Speed < Key in the desired speed in nm/min (maximum speed for a 1200 g/mm grating is 100o nm/min; see monochromator manual for other rate limits). Future scans will use this rate until the rate is revised. 3

GRAT: Press the function key below the GRAT command. The following screen is shown: > 1 1200 g/mm Blz=500 2 600g/mm Blz=750 3 150 g/mm Blz=300 1 2 3 T2 T3 The arrow by the number indicates which grating is now in place. To select another grating, press the unction key below the 1, 2 or 3 grating label. Note that only the gratings for the selected turret are shown. To determine which gratings are available on the other turrets, press the function key below the T2 or T3 label for the second and third turrets. To use these gratings, the actual turret must be physically installed in the monochromator. Press the NXT key and the menu line changes to 4 5 6 T1 T3 This allows selecting the gratings on the second turret if that one is installed. Press the NXT key again and the following menu is displayed 7 8 9 T1 T2 This allows selecting the grating son the third turret if that one is installed. Press the NXT key again and the menu time QUIT is displayed. Pressing the function key below QUIT, allows exiting the GRAT menu and returning to the main menu. TURR: Press the key below the TURR menu selection. The following menu is displayed: Grat1 Grat2 Grat3 >1200 600 150 600 300 not not not not 1 2 3 QUIT This menu shows all of the grating on each of the turrets purchased with the monochromator. The arrow which grating is selected. In this case, the arrow points to the first line indicating the first turret is installed and selected. When installing another turret, select the desired turret number and press the function key below that number. Then physically install that turret. Use the function key below the QUIT label to exit the turret menu. 4

From the main menu, press the NXT key and the following menu will be displayed: SLITS QUIT SLITS: Pressing the function key below the SLITS label will allow control of the motorized slits. The following menu is displayed: Slits: Side Entr: 250?m Front Entr: no slit Front Exit: 1000?m Side Exit: 10?m SID N FRT X SID X QUIT To adjust the width of a particular slit press the function key below the desired slit. SUD B represents the side entrance slit, FT N represents the front entrance slit (note in this case this label is missing since there is no motorized front entrance slit installed), FRT X represents the front exit slit and SID X represents the side exit slit. When one of these menu selections is made the following screen is shown: Slit width: Enter microns < Enter the desired slit width in microns to a resolution of 1 micron (for example 250 microns). Press the ENTER key to se the slit to the desired value. After the slit is set, the display will show the revised slit width. Note that it takes longer to set a slit lower in value to the present slit width than to set to a higher value since backlash compensation is used when going from higher to lower slit settings. Press the function key below QUIT to return to the main menu. From the main menu, the other set of manus available are the UTILITY menus. They are accessed by pressing the function key below the UTIL label in the main menu. These menus are as follows: INST: Press the function key below the INST label to access the INSTALL menu for installing gratings into the monochromator. Note that this is only used when physically installing a grating onto one of the grating turrets in the monochromator. 5

The gratings are normally installed when the monochromator is manufactured. The following menu is then displayed: GRAT GROV BLAZE HOL NM MCR To allow the monochromator to recognize a grating to be installed, use the following procedure: Select the GRAT function and enter the position number of the grating to be installed. Select the GROV function and enter the groove density in g/mm (e.g. 1200). Select the BLAZE function and enter the blaze wavelength for the grating to be installed. Select either HOL, NM or MCR for the units of the blaze wavelength (HOL for holographic, NM for manometers or MCR for microns). Press the NXT key and the following menu is then displayed: UN DONE EXIT Press the function key below DONE label to complete the installation of the grating. To uninstall a grating, select the GRAT function then use the NXT key to get to the UN function to complete the UNINSTALL process. CKSU: Press the function key below the CKSU label to read the checksum of the installed EPROM. This number varies from version to version of the software but will typically be a six digit hexadecimal number such as 5F162B. The number will be displayed for approximately 5 seconds and then the standard utility menu returns. INIT: Selecting this function resets the monochromator. GPIB: Press the function key below the GPIB label to display and/or change the GPIB address. The following menu is displayed: GPIB address: 11 Enter Number < You can enter another number between 1 and 30 or press the ENTER key without entering a number to retain the previous address. 6

RESTO: This function is used to restore the factory default and calibration settings. Unless you have reason to believe that these values have been corrupted, do not use this function. When selected, the following menu is presented: Restore factory settings Proceed? YES NO Select yes to restore the settings and no to exit the routine without change. MODL: Displays the model number of the monochromator for approximately 5 seconds and then returns to the utility menu. Press NXT to get to the remaining functions of this menu. HOME: This function is used to initialize the monochromator wavelength and the motorized slits. When selected, the following menu is presented: Home slits and Mono: SID N FRT N FRT X SID X MONO QUIT The labels for the respective slits will not be shown if that particular motorized slit is not installed. When one of the slits is selected, that slit is initialized to 10 microns. When MONO is selected, the wavelength of the monochromator is set to 0 nm on grating number 1 unless different initial values have been installed. Press the key below QUIT to exit the HOME function and select QUIT again to exit the utility menu. 7

Software Reinstallation: The software for the Acton 750-749 Remote Scan is installed at the factory when the 750-749 is purchased. If, however, the software needs to be reinstalled for any reason, the enclosed disk contains all the files necessary for complete software installation. Included on the disk are the Princeton Instruments files SP750LIB, INSTALL and WIPE. Also included is a copy of the file transfer program KERMIT from Columbia University. The Kermit program is included at no cost and may be copied or distributed as long as the following copyright notice is included: Copyright 1989, Trustees of Columbia University in the City of New York. Permission is granted to any individual or institution to use, copy, or redistribute Kermit software, so long as it is not sold for profit, provided this copyright is retained. Installation Instructions: Attached the 9 pin to 9 pin adapter to the serial port of the computer either com 1 or com 2. Attached the calculator cable with the flat 4 pin connector to the HP-48 calculator and attach the 9 pin connector to the adapter at the comp port. If a previous version of the SP-750 control program has been installed on the calculator, it is necessary to erase this program before loading the new version. This can be accomplished by clearing the memory in the HP-48 or by loading a special program to erase the SP-750 program. To clear memory in the HP-48 calculator, simultaneously press A and F function keys and the ON key. Release all three at once. Press the F function key alone to clear memory. 8

Create a directory on the computer hard disk labeled SP750 and copy all files from the installation disk to this directory. Change directory to SP750 and type KERMIT <cr>. In Kermit, type SET BAUD 9600 <cr>. In Kermit, type SET PORT 1 <cr>. (or SET PORT 2 as appropriate) If not previous version of the SP750 program exists on the HP-48, skip to the section labeled (A). On the HP48, press LEFTSHIFT (purple on the HP48G), then 1 (for the I/O send/receive menu). In Kermit, type S WIPE <cr>. (This will erase the previous version of the SP750 program) (A) In Kermit, type S SP750LIB <cr>. (The code will be sent to the HP-48 in approximately 130 packets, and a beep will be heard when the transmission is complete). On the HP-48, press F (RECV). (The Hp-48 is now Connecting, which is waiting for an object to be sent by Kermit in packets). On the HP48, press LEFTSHIFT (purple on the HP48G), then 1 (for the I/O send/receive menu). On the HP-48 press F (RECV). (The HP-48 is now Connecting, which is waiting for an object to be sent by Kermit in packets). 9

In Kermit, type S INSTALL <CR>. (The code will be sent to the HP-48 In 5 packets, and a beep will sound at The end of transmission). In Kermit, type Q <cr>. This returns To DOS. On the HP-48, press F (RECV). (The HP48 is now Connecting )> On the HP-48, press VAR. The menu at the bottom of the screen should now show INSTA SP750 IOPAR IOPAR has the baud rate, ect currently used by the HP-48. On the HP-48, press A (INSTALL) (This stores the library SP750LIB into PORT 0:. The HP-48 will automatically Turn itself off at this time). On the HP-48, press ON. Press NXT to get to the remaining functions of this menu. On the HP-48, press RIGHTSHIFT (green on the HP-48G), then 2). (The menu at the bottom of the screen should now show SP750 with a bar over the label indicating a submenu). On the HP-48, Press A (SP750). The HP48 is now ready to connect to a monochromator. The operating instructions are included in the SP-750 manual. 10

HOME: This function is used to initialize the monochromator wavelength and the motorized slits. When selected, the following menu is presented: Home slits and Mono: SID N FRT N FRT X SID X MONO QUIT The labels for the respective slits will not be shown if that particular motorized slit is not installed. When one of the slits is selected, that slit is initialized to 10 microns. When MONO is selected, the wavelength of the monochromator is set to 0 nm on grating number 1 unless different initial values have been installed. Press the key below QUIT to exit the HOME function and select QUIT again to exit the utility menu. 11