NXL Series Inverters HVAC Inverters made simple
Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter series: Simple...... to select! - Suits all pumps and fans - Power range from 0.25 kw to 0 kw - EMC Class C RFI filter... to set up! - Commissioned within 0 seconds - Pre-configured applications - Start-Up Wizard... to install! - Space-saving bookshelf design - Panel or surface mount - High protection classes (up to IP5)... to talk to! - Modbus built-in - Plug-In cards for Profibus, LONWORKS, CAN, BACnet, proprietary buses Typical applications HVAC systems Fans Pumps Other applications - Heating - Ventilation - Air conditioning - Cooling - Etc. - Air conditioning - Cooling Towers - Condensers - Boilers - Car parks - Tunnels - Etc. - Heating - Cooling - Water supply / treatment - Irrigation - Etc. - Lifts & Escalators - Greenhouse controls - Compressors - Etc. Benefits: - Easy to control and monitor - Optimized energy management - Increased comfort - Reduction of mechanical resonances Benefits: - Efficiency - Comfort - Energy savings - Easy to integrate to HVAC systems - Fire Mode Benefits: - Secured Water flow control - Monitored flow control - Flow limit control - Energy savings - Easy to integrate to HVAC systems Benefits: - Efficiency - Energy savings - Easy to apply NXL series inverters optimise HVAC control solutions in buildings, thereby yielding energy savings of up to.
NXL HVAC / The 0 sec solution! The NXL HVAC series is specifically configured for use with fans & pumps. Through pre-configured applications 95 % of the usual requirements in the building controls industry are covered. It s straight out of the box concept and the Start-Up Wizard allow 0-seconds basic commissioning. 0 sec A free option board slot offers communication to a huge variety of standard and proprietary protocols. Type overview: Mains voltage 80-500 V, 50/60 Hz, ~, enclosure class IP5, EMC level C RFI filter Loadability Motor shaft power Low High 00V supply AC drive type IL 0 % IH Maximum I5 0 % 0 C 50 C Frame size HVAC0C5 HVAC0C5 HVAC05C5 HVAC07C5 HVAC09C5 HVAC2C5. 2.0.6.7 8. 9.9.2. 5.0 6.5 8...5. 8.6 0.8 8..5..5 HVAC6C5 HVAC2C5 HVACC5 6.0 2.0.0 25..0 2.0 6.0 2.0 8.0 2.0 5 2 2 6 5 HVAC8C5 HVAC6C5 HVAC6C5 8.0 6.0 6.0 2.0 5.0 67.0.0 8.0 6.0 7 57 69 62 76 92 8.5 0 5 8.5
NXL General-Purpose Honeywell NXL General-Purpose drives have more general default configuration options, but still maintain the concept of minimal parameters. Two free option card slots for I/O expansion and communication are built-in. Type overview: Mains voltage 80-500 V, 50/60 Hz, ~, enclosure class IP2, EMC level H Loadability Motor shaft power Low High 00V supply AC drive type IL 0 % IH Maximum I5 0 % 0 C 50 C Frame size NXL000V5C2H NXL000V5C2H NXL0005V5C2H NXL0007V5C2H NXL0009V5C2H NXL002V5C2H. 2.0.6.7 8. 9.9.2. 5.0 6.5 8...5. 8.6 0.8 8..5..5 NXL006V5C2H NXL002V5C2H NXL00V5C2H 6.0 2.0.0 25..0 2.0 6.0 2.0 8.0 2.0 5 2 2 6 5 NXL008V5C2H NXL006V5C2H NXL006V5C2H 8.0 6.0 6.0 2.0 5.0 67.0.0 8.0 6.0 7 57 69 62 76 92 8.5 0 5 8.5 Type overview: Mains voltage 80-500 V, 50/60 Hz, ~, enclosure class IP5, EMC level H NXL000V5C5H NXL000V5C5H NXL0005V5C5H NXL0007V5C5H NXL0009V5C5H NXL002V5C5H. 2.0.6.7 8. 9.9.2. 5.0 6.5 8...5. 8.6 0.8 8..5..5 NXL006V5C5H NXL002V5C5H NXL00V5C5H 6.0 2.0.0 25..0 2.0 6.0 2.0 8.0 2.0 5 2 2 6 5 NXL008V5C5H NXL006V5C5H NXL006V5C5H 8.0 6.0 6.0 2.0 5.0 67.0.0 8.0 6.0 7 57 69 62 76 92 8.5 0 5 8.5
NXL Compact The NXL Compact drives are cabinet-mounted units for lower motor powers up to kw, suitable for both 208 20 V and 80 500V supply voltages. The compact size and flexible installation options make them suitable for installations where space is at a premium. The standard I/O can be extended with one I/O expander board or one fieldbus board. Type overview: Mains voltage 80-500 V, 50/60 Hz, ~, enclosure class IP20, EMC level N Loadability Motor shaft power Low High 00V supply AC drive type IL 0 % IH Maximum I5 0 % 0 C 50 C Frame size and dimensions [W x H x D] NXL000V5CN0 NXL0002V5CN0.9 2. 2. 2.6..9 2.0 2.9 2.6.8 0.55 0.7 0.55 MF2 60/0/50 MF2 60/0/50 NXL000V5CN NXL000V5CN NXL0005V5CN. 5..6.7 5.9 2...6 5.0 6.5.8 6.6 8.6..5..5 MF 8/8/72 MF 8/8/72 MF 8/0/72 Type overview: Mains voltage 208-20 V, 50/60 Hz, /~ (~ motor), enclosure class IP20, EMC level N NXL0002V2CN0* 2. 2.6.7 2.6. 0.7 0.25 MF2 60/0/50 NXL000V2CN NXL000V2CN NXL0006V2CN.7.8 6.6. 5. 7.2 2.8.7.8.2 7.2 7. 9.6..5 0.55. MF 8/8/72 MF 8/8/72 MF 8/0/72 *single-phase in, -phase out
Option Boards Card typecode Slot I/0 Signal DI DO Al ma isol. AO ma isol. EO NO NC RO NO Therm +2 EXT +2 V Note Basic /0 cards [OPT-A] OPT-AA OPT-AI included in NXL HVAC series /0 expander cards [OPT-B], typical OPT-B2 OPT-B OPT-B5 2 analog signals galvanically isol. seperat. Fieldbus card [OPT-C] OPT-C2 OPT-C OPT-C OPT-C5 OPT-C6 OPT-C7 OPT-C8 OPT-CI OPT-CJ RS-85 (Multiprotokol) Profibus DP LonWorks Profibus DP (D9 type connector) CANopen (slave) DeviceNet RS-85 (Multiprotokol, D9 type connector) Modbus/TCP (Ethernet) BACnet N2 (Modbus as standard) N2 (Modbus as standard) Control Inputs/Outputs Standard I/0 OPT-AA [typical option] Terminal Signal, default settings Terminal Signal, default settings +0 V Reference voltage +2 V 2 V auxiliary voltage 2 5 AI+ AI- AI2+ AI- Analog input, 0-0 V (0/-20mA) Al common Analog input, 0/-20 ma (0-0 V) Al common 2 5 GND DIN DIN2 DIN I/0 ground Preset speed 2 Fault reset Disable PID 6 7 8 9 0 +2 V GND DIN DIN2 DIN 2 V auxiliary voltage I/0 ground Start forward Start reverse Preset speed 6 2 25 26 D0 R0 R0 R0 Digital output, Ready Relay output, RUN GND I/0 ground 8 9 A0+ A0- Analog output, output frequency A0 common OPT-AI [typical option]* A RS85 Serial bus (modbus RTU) Terminal Signal, default settings B RS85 Serial bus 2 +2 V 2 V auxiliary voltage 0 +2 V External control voltage supply GND I/0 ground 2 2 R0 R0 R0 Relay output, FAULT 5 6 DIN DIN2 DIN Preset speed 2 Fault reset Disable PID All inputs and outputs of the standard I/0 and option boards are freely programmable 25 26 28 29 R0 R0 TI+ TI- Relay output, RUN Thermistor input (galvanically isolated) * included in NXL HVAC Series
Other typical options: Option Oder Typecode Suitability IP5 enclosure IP5-FR - - Replace 2 by 5 in the type code, e.g. NXL005C5H (SSS...) IP5 kit, e.g. IP5-FR Through-hole mounting - E.g. NXL00,5CTHSTS..., IP5 back, IP2 front, kits available External brake resistors BRR-00-LD-5 BRR-00-LD-5 BRR-005-LD-5 BRR-006-LD-5 0005-0005 005 0085-0065 0065 LD = Light Duty: 5 sec nominal torque braking from nominal speed decreasing linearily to zero, once per 20 sec. HD = Heavy Duty: sec nominal torque braking at nominal speed + 7 sec nominal torque braking from nominal speed decreasing linearily to zero, once per 20 sec. Replace LD by HD in the type code, e.g. BRR-00-HD-5 The brake resistor manual is available for more precises selection Panel door installation sets DRA-02L DRA-0L All Door installation set with a 2-m RSC cable Door installation set with a -m RSC cable PC adapter PAN-RS All Adapter PAN-RS and RSC cable are required for PC connection RSC cables RSC-2M RSC-M All 2-meter-long RSC cable for PC connection -meter-long RSC cable for PC connection Varnished circuit boards - Replace the S by V, e.g. NXL005C5HSSV... C-level RFI filters - Replace H by C in the type code, e.g. NXL005C2C (SSS...) Options for compact units [IMF2-MF] RFI filters RFI-002-2- RFI-00-2- RFI-0008-5- 000-00062 000-00062 0005-00055 RFI filter for 208-20 V units, H level, ~ supply RFI filter for 208-20 V units, H level, ~ supply, footprint installation RFI filter for 80-500 V units, H level, footprint installation DIN rail installation MF2-MF Replace S by D in the type code, e.g. NXL00025CH0 SDS Technical distinctions for selecting an inverter. Low Overload Low applications are normally machine related to Variable Torque (pls see below) i.e.. centrifugal fans and pumps. Low over load allows you to the motor 0 % for minute in every 0 minutes with starting torque of The max ambient temperature in full load is 0 C. Variable Torque rating This typically describes the torque curve of a centrifugal pump or centrifugal/axial flow fan. The torque required at zero speed is very close to zero. As the machine increases in speed, the torque increases by the square of the change in speed and the power increases by the cube of the speed change. High Overload High applications are normally machine related to Constant Torque (pls see below). High allows you to the motor minute in every 0 minutes with starting torque of 200 %. Constant ambient temperature in full load is 50 C. Overloadability For all NXL drives, ability is defined as follows: High:.5 x IH ( min/0 min) at 50 C; Low:. x IL ( min/0 min) at 0 C; IS for 2 seconds every 20 seconds. Constant Torque Rating This typically describes the torque curve of machines other than those that fit within the variable torque category. This is a more generic term which is used to encompass groups of machines which do not follow the rule above, but may not have constant torque characteristics. These would be for example, cranes, elevator, conveyors, extruders, mixers, stirrers, machine tools etc.
Find out more For more information on Honeywell inverters and other Honeywell products visit us online at http://europe.hbc.honeywell.com Automation and Control Solutions ACS Products Honeywell Control Systems Ltd Honeywell House Arlington Business Park Bracknell, Berkshire, RG2 EB Tel 0 65 66 55 Fax 0 65 66 www.honeywell.com/uk Honeywell GmbH Böblinger Strasse 7 D-70 Schönaich / Germany Tel 070 67 0 Fax 070 67 9 www.honeywell.com ENB-07GE5 R0906 September 2006 2006 Honeywell International Inc.