R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation



Similar documents
Hotel System Management The Hotel Smartest Solution

STERILIZERS, LABORATORY DRYING OVENS

HOTEL ROOM MANAGEMENT SYSTEM - specifications OVERVIEW

HCR3.2/.. Chipcard reader HOTEL SOLUTION

TMS TANK MANAGEMENT SYSTEM


NC-12 Modbus Application

T5000 T000 LCD Digital Fan Coil Thermostat

Incubator with mechanical convection

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Panasonic/Sanyo A/C Interface Modbus RTU Installation Instructions

Inwall Room Temperature Unit

GSM HOME SECURITY SYSTEM

EDI Distributor Control Interface Wiring and Setup Instructions

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Electronic Control Devices The European Product Catalogue 2007

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

D45. SySTEm. ThE high-performance

Access Control Using Smartcard And Passcode

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

HERZ-Thermal Actuators

HVAC Processes. Lecture 7

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Fingerprint Based Biometric Attendance System

IAdea GPIO Extender Application Note

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Failure code manual. content

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Quick Connect. quick - simple - efficient.

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system

LIFT CONTROL SYSTEMS CATALOGUE 2007

Advanced hotel systems

Material test chamber with mechanical convection

Barcode Reader Series BCL 31, BCL 32, BCL 34

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

ABB i-bus KNX. Room Solutions. ABB STOTZ-KONTAKT GmbH - 2CDC N0202, page 1

RAD-SYS-NEMA4X-SMS Control Cabinet. Solution guide for SMS-based remote access control and intrusion detection system

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SMS GSM Alarm Messenger

Shunt lock function 3066 Operator Instructions

Advanced hotel systems

User's Guide. CTS6000 WebControl

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

CONFIGURABLE SAFETY RELAYS

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Voltech DC1000. Precision DC Bias Current Source

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Temperature & Humidity SMS Alert Controller

PRODUCT LIST Facility DDC Access WebXL DDC

ELECTRONIC BOARDS - SUPRA

GSM COMMUNICATORS CATALOGUE

Electronic Control Devices The European Product Catalogue 2007

Laboratory Autoclave SN210/310/510,SQ510/810

LIFT CONTROL SYSTEMS CATALOGUE 2007

ELECTRIC CENTRAL HEATING FLOW BOILER

FLOOR INDICATORS CATALOGUE 2007

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

T7560A,B,C Digital Wall Module

GSR 12/24V. GSR 12/24V Technical manual Model 12/24

Repeaters and Mimics Data Sheet

Digital inductive conductivity transmitter

PROXIMITY CARD READERS C-10, C-20, C60, C70

IntesisBox KNX Modbus RTU master

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

Heating Controller. Building Technologies HVAC Products

SYSTEM 4C. C R H Electronics Design

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

User Manual. Before installation and use, please read the user manual carefully.

IntesisBox Modbus Server SAMSUNG Air Conditioners

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

M1000 Process Alarm Monitor

Integrated Building Management and Security System. Building Automation & Security.

Central Monitoring and Control Software for GRMS & Access Control

Model: DC-A2IO Advanced HVAC Controller

FLOOR INDICATORS CATALOGUE

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

ECP 208. Cold Rooms Controllers USER S MANUAL

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Contents. : AEOS Blue cabling and technical aspects. NEDAP N.V. IDEAS Information Bulletin No: H032. Date : 12 January 2016

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Limited Service Fire Pump Controllers Features

is then retained absolutely without interruption.

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Ticket Reader with real time clock and magnetic encoding

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

F454. Web Server. User Manual 05/12-01 PC

Transcription:

R001 Room Control Unit TG650 Summary TG650 Microprocessor Room Control Unit is designed to manage and control hotel room services. The Room Unit automatically manages the electric system validation on customer or staff presence inside the room. By the function of Temperature setting it s possible to manage various temperature levels depending on the room occupation, with the possibility of local parameters adjustements or from the main PC unit. Moreover it is possible to manage fan-coil systems with 2 or 4 pipes, with or without regulation valves and split. The access to the room is managed by a reader that provides the door open validation through an electric door-lock. Each access to the room and each alarm advice is recorded in the main PC unit. Control functions Orders Planning Installation Room temperature management with set-point variation Regulation valve/s and fan-coil speed control Electric loads control Courtesy light control Access control Buzzer/door-bell control Anti-intrusion (window/door) and bathroom Alarms Do not disturb message Two available and settable alarms (i.e.: flooding) To order the Control Unit simply specify: Control Unit model: TG650 for each room TG650A for each common area (Restaurants, swimming-pools etc...) TG650T for Technologic Areas (pumps, levels etc... status control) Room Control Unit is placed inside an embedding panel with protections and TG001 transformer. When planning the system installation adhere to all the norms (CEI) related to electric device installation. The module, usually replacing the room control unit placed inside the electric panel provided with a DIN guide, must be accessible. The transformer can be placed in the same container. Linked units must be placed as follows: - Access reader, beside of the entrance door at the door-lock height - Validator Pocket, inside of the room, close to the entrance door - Environmental thermostat, in the middle of the room Page 1/5

Other system components Tecnical Features Unity addressing Transponder reader TG 348 Chip card reader TG 325 Room Services Validator TG 666 Environmental Thermostat TG 503 Serial converter PC/Bus TG 004/5 Repeater Bus floor (optional) TG 606 Feeding Corrurent Digital input for Output Digital output 12 V DC 11 V AC TG001 300 ma (2 A max) Bathroom Allarm Button (Do not distur.) Window contact Door contact Pocket contact Auxiliary 1,2,3 Feeding 10 16 V DC (600mA Max) Buzzer command (40mA max) Output command 220 V AC (8 A max) Command output 220 V AC (8 A max) Room bus Building bus Dimension (HxLxD) Weight Working Temp. Store Temp. Relative humidity Protection grade The room unit must be addressed using the special dip-switches. FanCoil 1,2,3 Valve Auxiliary Lock Speed and courtesy light RS485 (4800 baud) RS485 (38400 baud) 90x160x65 mm 0,300 Kg 0..+50 C -20..+ 50 C 80 % annual average IP 44 Number of the DIP Switches Value binary for DIP Switch Room address wanted (examples) DIP Switches ON positioned (examples) 1 1 1 1 2 2 2 2 3 4 3 1,2 4 8 4 3 5 16 10 2,4 6 32 25 1,4,5 7 64 125 1,3,4,5,6,7 8 128 250 2,4,5,6,7,8 Example address room 25: DIP Switches su ON 1,4,5 ON 1 2 3 4 5 6 7 8 Page 2/5

Room Unit Functions list Electric: Shutdown electric devices during the customer's absence (adjustable) Water: Shutdown toilet flow in an empty room, if provided of a solenoid valve or on flooding sensor advice Air Conditioning: Energy saving temperature setting in an empty room (adjustable) Artificial ventilation shutdown at window opening (adjustable) Security: Room access with Transponder/CHIP card only Bathroom alarm management (adjustable) Door and windows intrusion signaling Flooding alarm signaling (adjustable) In-room settables: Set Point Value adjustments Artificial ventilation speed adjustments Do not disturb From the main Pc unit: Rooms and common areas access codes programming Operation parameters adjustment Set Point Value adjustments Room status queries Alarms signaling Thermo-regulation data acquirement (temperature, valve position etc...) Outputs: Air conditioning control Hot/cold valve control Fan speed 0-1-2-3 control Electric loads control, electric door-lock and door-bell Communication: The unit communicates with an RS-485 Bus Dual through the main PC unit, that manages and acquires all meaningful information The unit communicates through an RS-485 Bus Dual with room units like card/transponder readers, temperature control unit and entrance/exit unit. Page 3/5

Connection schemes (Room type) Window Freezer Thermostat Room BUS Fan Coil SOS Sonda Flooding Courtesy Pocket Lock Door Central Do not disturb Door bell-button Dimensions (mm) Reader 160 65 90 Page 4/5

Room connections unit Building bus RS 485 plug 8 pins Room Bus RS 485 Plug 6 pins Bathroom allarm Command (Do not disturb) Window contact Door contact Pocket contact Auxiliary 1 Auxiliary 2 Auxiliary 3 Dip Swiches for room address Feeding 11 V a.c. From TG001 Output do not disturb Output Buzzer GND Output 12 V Auxiliary command Auxiliary common Valve common Valve command Fan coil common Speed 3 Speed 2 Speed 1 Common light Command light Common courtesy light Command courtesylight Common lock Command lock Page 5/5