Monarflex Vapour Control Layers



Similar documents
Multi-layer Insulation Blanket for Roofs

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Including. Rubershield-Pro. Breather Membrane

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Monarflex Tanking & DPM Systems. Cold and Hot. Applied. Structural. Waterproofing. Membranes YEAR. Geomembr nes WORLD LEADER IN WATERPROOFING

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Built Up Flat Roof Waterproofing Systems

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Bituminous Sheet Flat Roofs: Their repair and maintenance

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Ubiflex. Non-lead flashing system

Cl/SfB (13.9) a comprehensive. technical guide. to the specification of. vapour control layers. GROUP LTD

DELTA Premium Moisture Management Systems for Foundations.

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

FireSmart IRS Insulating Roof Screed

MONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED)

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Peel & Seal Self-Stick Roofing Solutions

SikaProof A Technology

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Product Guide Specification

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM


BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

The formation of roof waterproofing details calls for

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.

WATERPROOFING FOR CONCRETE STRUCTURES

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Rooflight INSTALLATION INSTRUCTIONS

Asphalt Shingle Application Requirements

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

DENSO WATERPROOFING SYSTEMS

GYPSUM AREA SEPARATION FIREWALLS GA

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

BLACK JACK ALL WEATHER ROOF COATING

Epdm Flat Roofing Systems

Roofers Guide to Underslating Membranes

VM ZINC : standing seam Guidelines for specification and installation

The existing roof angle change terminations and flashings when sound and intact can be reused.

Low Energy Low Carbon Buildings

ICOPAL POUR AND ROLL ROOF WATERPROOFING ICOPAL POWER ELASTOMERIC ROOF WATERPROOFING SYSTEM

Your guide to home maintenance. Flat Roofs

WATERPROOFING SikaProof -A TECHNOLOGY

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

REDLAND DRY BONDING GUTTER. Installation Instructions for Redland Dry Bonding Gutter

CONIROOF : Tailor-made Solutions for your Roof CONIROOF

SANS FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/ / / /341

Energy Company Obligation (ECO): Technical Monitoring Questions

Polymeric membrane for roof waterproofing

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

CHAPTER 7: Building Systems ROOFING SYSTEMS

How to repair your existing low slope flat roof.

I n s u l a t i o n. Low Energy Low Carbon Buildings

SEAMS SEAMING USING SEAM TAPE

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

Preprufe 160 Sheet Tanking and Waterproofing Membrane

Cupa Natural Slate Roofing design and fixing guide

Rockwool Cladding Roll

How To Test A Wrap N Drain X Dampproofing System

Shingle Roofing: What s below the surface is important

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

WATERPROOFING OF WET ROOMS

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Low Energy Low Carbon Buildings

Residential Roofing Guide

Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Specialist vapour diffusion torch-on membrane Wentylacyjny Werner PYE PV250 S54 is used to make new roofs as well as renovate old ones.

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

MODULAR EPDM ROOFING SYSTEMS

How To Repair A Boat Landing Deck With A Boat Bed

Roof Insulation Building. Energy. Environment friendly e-library

THE REDLAND GUIDE TO BS 5534

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

RT7. Practical commercial roofing & cladding solutions innovative products

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Quality You Can Trust Since From North America s Largest Roofing Manufacturer

The Kingspan Insulation Price List 1 st January 2013

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

Low-slope reroofing guidelines

BAUDER BITUMINOUS ROOFING SYSTEMS BAUDERFLEX ROOF WATERPROOFING SYSTEMS

Please read the entire document before purchasing and installing any of these products

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

Ground Gas Barriers.

Transcription:

Monarflex Vapour ontrol Layers I/Sf 27.2 May 2008 N6 The simple and cost effective way to reduce air leakage, maximise thermal performance and prevent harmful condensation. High performance VL s designed for use within insulated metal sheeted and single ply membrane roofs.

Monarflex Vapour ontrol Layers range of high performance vapour control layers specifically designed for use within insulated metal sheeted and single ply membrane roofs. Why a Vapour ontrol Layer? The problem Many roofs are at risk of failure due to condensation forming within the roof structure. ondensation occurs when the air temperature falls to the dewpoint and the air becomes saturated. Sources of condensation include Water enclosed in the building during construction Internal air xternal air entering between the roof cladding and the lining Whatever its source, condensation can lead to serious damage. The uilding Regulations require provision to prevent excessive condensation in roofs and roof voids (Regulation, 1995). dvice on meeting the Regulations is contained in the associated pproved ocuments. Guidance is also contained in S 5250:1989: ode of practice for the control of condensation in buildings and in the R report Thermal insulation: avoiding risks. The risk of condensation can be reduced or avoided by Removal or reduction of water vapour produced in the building Maintaining the construction above the dewpoint temperature Preventing water vapour reaching cold layers of the construction The solution The most effective way to avoid condensation in roofs is to prevent as much of the water vapour as possible reaching the cold side of the thermal insulation. This can be achieved by providing a Monarflex vapour control layer on the warm side of the thermal insulation while ensuring the vapour resistance of the construction reduces progressively from inside to outside. In some cases a breather membrane such as Monarflex SP400 may be required on the cold side of the insulation. 2

Why a Monarflex Vapour ontrol Layer? Proven Performance Icopal is one of urope s leading manufacturers of reinforced polythene based membranes for the construction industry with over 30 years experience in the design, development and manufacture of industry leading solutions that include products now universally accepted as the industry standard, proven over and over again in use. Quality ssurance ll Monarflex products are manufactured under strict quality guidelines. s part of our commitment to the highest standard of quality and service, Icopal is registered to S N ISO. RGISTR Technical Support To assist specifiers and contractors, Icopal offers R technical support and advice on all aspects of waterproofing and membrane specification and installation. Our service includes the provision of detailed drawings, complete system specifications and a telephone advice line. or further information call 0161 865 4444 or visit www.icopal.co.uk IRM eatures and enefits of Monarflex VL s Monarflex multi-layer VL s are manufactured from virgin with built-in reinforcement grids of HP. Some also have a layer of aluminium foil for higher water vapour resistance performance. The reinforcement grids give great strength and tear resistance, producing membranes which are stable when laying and during the sheet or spacer fastening process. Monarflex VL s are thermally stable from -40º to +75º. This ensures the membranes retain their integrity when being installed or used in extreme temperatures. Monarflex VL s are suitable for most roof types and building uses from Monofilaments for buildings with low to medium humidity to Reflex 275 for buildings with high humidity such as textile plants, swimming pools, leisure centres and sports halls. ontents Product Range Reflex 275 4 Monofilament 250 4 Monarflex Netofol 4 ccessories 5 Installation and Sealing 5 Site Work 5 esign and Installation Metal Roofing and ladding 6 Single Ply Membrane Roofs 7 Reflex 275 Monofilament 250 Monarflex Netofol 3

Monarflex Vapour ontrol Layers Product Range RRNS pproved ocument to the uilding Regulations 1995. pproved ocument to the uilding Regulations 1992. S 5250: 1989: ode of practice for control of condensation in buildings. S 6229: 1982: ode of practice for flat roofs with continuously supported coverings. S 6367: 1983: ode of practice for drainage of roofs and paved areas. R Report: Thermal insulation: avoiding risks. S N ISO 9002: 1994: Quality systems. Model for quality assurance in production, installation and servicing. Reflex 275 five layer exceptionally high performance polyester reinforced membrane with aluminium foil for use in buildings with high humidity including sports halls, swimming pools and leisure centres. Product ata olour lue top surface, grey underside Roll size / weight 2m x 25m / 17kg Thickness 0.35mm Tensile strength 8.0kN/m Moisture vapour 0.005gm 2-24hr transmission Water vapour 43,000 MNsq-1 resistance Monofilament 250 three layer high performance reinforced membrane for use in buildings with low to medium humidity. luminium foil lown RITIS H OR O G R É MN T 01/3810 xtruded Polyester grid xtruded Product ata olour lear, black reinforcing grid Roll size / weight 2m x 50m / 25.1kg 4m x 50m / 50.5kg Thickness 0.25mm Tensile strength Moisture vapour transmission 5.9kN/m 0.4gm 2-24hr lown HP monofilament grid Water vapour resistance 530 MNsq-1 Monarflex Netofol three layer reinforced membrane for use in buildings with low to medium humidity. xtruded Product ata olour Transparant blue, black reinforcing grid Roll size / weight 2m x 50m / 20kg Thickness 0.2mm Tensile strength Moisture vapour transmission 3.5kN/m 0.6gm 2-24hr lown HP monofilament grid Water vapour resistance 350 MNsq-1 4

ccessories Monobond Tape high performance double sided tape for effective jointing of Vapour ontrol Layers. eatures and benefits Specially formulated for applications at temperatures down to -12º Makes impermeable waterproof seals at laps to ensure overall vapour resistance of the membrane Remains permanently flexible Quick and easy joining of side and end laps dheres to most construction materials including concrete, steel and timber Product ata olour Thickness Roll length/width lue 2mm 15mm x 24mm 30mm x 24mm 70mm x 15mm Installation and Sealing Monarflex vapour control layers must be laid with minimum 150mm laps and sealed with Monoband Tape. ll penetrations, such as pipes and vents, must also be sealed with an appropriate sealant tape. Refer to the separate Monobond Tape leaflet for preparation and installation details to other materials and structures. ll Monarflex vapour control layers have 150mm overlap guidelines printed on both edges throughout the rolls Monarflex vapour control layers are resistant to tears and punctures. ny mechanical damage which does occur during installation should be repaired with a patch of the membrane fixed in place by a suitable sealing tape. Once the roof is finished there is not usually any need for maintenance of the VL s. Site Work 150mm lap Monarflex vapour control layer 15mm strip of Monobond Tape Overlap guideline Monarflex vapour control layers are delivered to site in individually shrink-wrapped packages, each clearly labelled with the company name, the product name and size of roll. Packages should be stored on their sides on a clean, dry surface. Monarflex vapour control layers contain no toxic additives, are non-hazardous to health and can be handled without protective clothing. oshh data sheets are available. NS SPIITION LUSS Reflex 275 H31 Metal Profiled/lat Sheet ladding/overing 261 Vapour ontrol Membrane - Manufacturer: Icopal Limited. - Product reference: Monarflex Reflex 275. Vapour resistance (minimum): 43000 MNs/g. - ontinuity: No breaks, and with the minimum of joints. Penetrations and abutments: Seal to vapour control membrane with tape. chieve full bond. Laps: Not less than 150 mm, seal with tape. chieve full bond. - Tape: ouble sided sealant with vapour resistivity not less than the vapour control membrane. Size: 15mm x 2m Monobond LT double sided tape for all joints and penetrations. - Repairs and punctures: Seal with lapped patch of vapour control membrane and continuous band of sealant tape along edges. Monofilament 250 H31 Metal Profiled/ lat Sheet ladding/overing 261 Vapour ontrol Membrane - Manufacturer: Icopal Limited. - Product reference: Monofilament 250. Vapour resistance (minimum): 530 MNs/g. - ontinuity: No breaks, and with the minimum of joints. Penetrations and abutments: Seal to vapour control membrane with tape. chieve full bond. Laps: Not less than 150 mm, seal with tape. chieve full bond. - Tape: ouble sided sealant with vapour resistivity not less than the vapour control membrane. Size: 15mm x 2m Monobond LT double sided tape for all joints and penetrations. - Repairs and punctures: Seal with lapped patch of vapour control membrane and continuous band of sealant tape along edges. Monarflex Netofol H31 Metal Profiled/ lat Sheet ladding/overing 261 Vapour ontrol Membrane - Manufacturer: Icopal Limited. - Product reference: Monarflex Netofol. Vapour resistance (minimum): 350 MNs/g. - ontinuity: No breaks, and with the minimum of joints. Penetrations and abutments: Seal to vapour control membrane with tape. chieve full bond. Laps: Not less than 150 mm, seal with tape. chieve full bond. - Tape: ouble sided sealant with vapour resistivity not less than the vapour control membrane. Size 15mm x 2m Monobond LT double sided tape for all joints and penetrations. - Repairs and punctures: Seal with lapped patch of vapour control membrane and continuous band of sealant tape along edges. 5

Monarflex Vapour ontrol Layers esign and Installation RIG Metal profiled roof cladding Mastic Ridge flashing reather membrane Liner tray arry vapour control layer over ridge, overlap by 150mm min. and seal with Monobond Tape Metal Roofing and ladding Monarflex vapour control layers should be fully supported by the metal lining on the warm side of the thermal insulation. It is essential to form a vapour tight seal wherever the vapour control layer is penetrated, for example by pipes or ducts. This can be achieved by cutting a neat circular hole slightly smaller than the VRG Verge flashing reather membrane Metal vertical cladding arry vapour control layer over ridge, overlap by 150mm min. and seal with Monobond Tape penetration, stretching the material over to produce a tight fit and sealing around the penetration with a suitable sealing tape. ll joints in the vapour control layer must be lapped (minimum 150 mm) and sealed with Monobond Tape. tight seal can be achieved by compressing the lap with a wallpaper roller. ll Monarflex vapour control layers have 150mm overlap guidelines printed on both edges throughout the rolls UPSTN lashing VL sealed to upstand Metal profiled roof cladding Purlin t perimeters, the vapour control layer should be dressed up abutments, parapets, upstands, etc. and, ideally, be sealed to the vertical structure with an appropriate sealant tape such as Monobond Tape. VS & PNTRTION Metal flashing reather membrane Vapour control layer arry vapour control layer over ridge, overlap by 150mm min. and seal with Monobond Tape Seal breather membrane and VL to penetration using Monobond Tape 6

Single Ply Membrane Roofs Monarflex vapour control layers should be fully supported by the deck on the warm side of the thermal insulation. It is essential to form a vapour tight seal wherever the vapour control layer is penetrated, for example by pipes or ducts. G VS Welted drip Separation layer Protection (optional) Waterproofing layer Insulation Vapour control layer G eck ll joints in the vapour control layer must be VRG lapped and sealed with Monobond Tape. t perimeters, abutments, parapets and upstands the vapour control layer should ideally be sealed to the vertical structure and turned back onto the upper surface of the insulation board, where it will be lapped by Waterproofing layer Insulation eck Separation layer Protection (optional) Vapour control layer turned back over insulation the water proofing membrane. G UPSTN Upstand Metal flashing Separation layer Protection (optional) Waterproofing layer Insulation G Vapour control layer H eck H PNTRTION Metal flashing Separation layer Protection (optional) Waterproofing layer Insulation Vapour control layer G Seal breather membrane and VL to penetration using Monobond Tape H eck G H 7

I/Sf 27.2 May 2008 N6 Icopal Ltd arton ock Road Stretford, Manchester M32 0YL Telephone: 0161 865 4444 ax: 0161 866 9859 Technical ax: 0161 865 8433 email: info.uk@icopal.com Northern Ireland Telephone: 028 9037 0888 ax: 028 9037 0747 Republic of Ireland Telephone: 1800 409 056 ax: 1800 409 055 www.icopal.co.uk Total building protection from a single source When you deal with Icopal you ll enjoy all the advantages of sourcing a full range of top brand products from one supplier Protection for flat roofs Structural protection uilt up roof systems amp proof membranes Single ply roof systems amp proof courses and Green roof systems cloaks Liquid waterproofing systems ontainment membranes ire protection roofing systems Gas control systems Roofgard accessories Tanking/below ground waterproofing Protection for pitched roofs Warm & cold pitched roof Protection for people and systems the worksite reather membranes Standard and fire retardant Vapour control layers scaffold sheeting Non-permeable underlays all protection safety systems dge protection safety systems Sound protection coustic systems very effort has been taken in the preparation of this brochure to ensure the accuracy of representations contained herein. Recommendations as to the use of materials, construction details and methods of installation are given in good faith and relate to typical situations. However, every site has different characteristics and reliance should not be placed upon the foregoing recommendations. dvice can be given as to specific applications of the products, upon request. esign Ref: IO1681 www.icopal.co.uk