TrueAlarm Fire Alarm Systems



Similar documents
TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Gigabit Switching Ethernet Media Converters - Product User Guide

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Fire Control Panels Series Remote InfoAlarm Command Center for the 4010ES Fire Alarm Control Panel

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

NetScanner System. Toronto: , Montreal: , Toll Free: ,

3500/22M Transient Data Interface

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

Fire Alarm System Accessories

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

HARTING mcon 1000 Introduction and features

HM-W536 Install Guide

TrueAlarm Fire Alarm Systems

GEU Port Gigabit Switch

LIEBERT VNSA Installation Sheet

IFS SP-PoE Splitter User Manual

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Loop-IP6702 TDMoEthernet

Long Range Ethernet Extender

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

Office of Integrated Security Systems Longwood University Camera System Standards

HARTING econ 3000 Introduction and features

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

FCC COMPLIANCE STATEMENT

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

T1 Backhaul Connectivity Solution All Products :: Application Note

IP DSLAM IDL Quick Installation Guide

Optimux-34, Optimux-25

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

TrueAlarm Fire Alarm Systems

Provides one channel for Ethernet over existing

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Life Alarm Fire Alarm Controls

PROXIMITY CARD READERS C-10, C-20, C60, C70

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

VOICE RECORDING SYSTEM ISDN PRI / BRI

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

MDI/MDIX) FEP-32008T-3

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Installation Guide for GigaBit Fiber Port Aggregator Tap with SFP Monitor Ports

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Fire Fighter Phone System Installation Instructions

ABB RTU560A Series CMU & Modules

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

FlexPoint T1/E1 Copper to Fiber Line Driver

palm Switch Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch

Loop-IP6700 TDMoEthernet

Setting Up and Testing the MAX Hardware

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

Network Design. Yiannos Mylonas

Media Converters & Chassis

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Web Smart Switch

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Alliance System Ordering Guide

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ProCurve Switch 8000m (J4110A) and Switch 8000m

FriendlyNET FX Slot Modular Switch. User s Manual

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

User Manual. EtherUSB

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system


8-Port 10/100M N-Way Mini Switch

HP ProCurve High-Speed Transceivers Installation Guide

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

8-Port PoE Network Switch

User's Manual. 8-Port 10/100Mbps with 4-Port PoE Fast Ethernet Switch FSD-804P - 1 -

IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring.

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Transcription:

TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es provide up to eight wired Ethernet connections with individual earth fault supervision Wired Ethernet cable distance of up to 328 ft (100 m) es can be interconnected to extend connection capacity and/or distance using either Ethernet wired ports or fiber optic ports Fiber optic cable switch connections provides a distance of up to 1.24 miles (2 km) for multimode fiber, and up to 9.3 miles (15 km) for single-mode es are UL listed to Standard 864 and ULC listed to Standard S527 Switches are available without earth fault supervision for special applications not requiring fire alarm listings For additional TrueSite Workstation server and client information, refer to data sheet S4190-0016 Available with three connection options: Eight Ethernet wired ports with RJ-45 terminations Four wired ports and two single-mode fiber optic ports (SC connectors) Four wired ports and two multimode fiber optic ports (SC connectors) Earth faults are reported three ways: An on-board IDNet Supervised IAM is available for connection to a compatible Simplex fire alarm control panel An on-board trouble relay provides contact transfer On-board LEDs identify fault location per port Description Overview. es combine an Ethernet switch module with an earth detection circuit (for wired Ethernet connections), housed in a dedicated cabinet. Using es allows interconnection of a TrueSite workstation server, and multiple TrueSite workstation clients, into a dedicated LAN. When networked, the TrueSite workstation clients can monitor and (if authorized) control fire alarm system activity. If additional connections or increased distances are required, Fire Alarm es can be connected to additional switches. Switch Details. The uses an Ethernet switching hub to bridge between connected data links. It also has the ability to segment the Ethernet network in separate collision domains for network survivability. to additional Remote es (if required) Remote Fire Command Center with Remote Client Dedicated Fire Alarm LAN Remote Client Facility Maintenance Center TrueSite Workstation Server Facility LAN Internet Connection Remotely Located Fire Alarm Power and status supervision from local Control Panel Control Panel Network Loop Connections (up to 7 loop capacity) Off-site access Connection Reference Switch Operation. Data packets are inspected to determine the source and destination address of each packet, then forwarded accordingly. Simultaneous data exchanges are allowed on different data links, resulting in more throughput. Operation is either half-duplex or full-duplex. Switch Communications Support. Wired Ethernet Communication protocols include 10Base-T or 100Base-TX, allowing network Ethernet connection speeds of 10 Mbps or 100 Mbps. Models with fiber optic ports allow es to be interconnected using the advantages of fiber optics connections. Fiber optics ports operate at 100Base-FX. * Refer to product selection details on page 2 for listing specifics. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:336 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4190-0018-3 3/2012

Description (Continued) Earth Fault Detection. When an earth fault is detected by the Earth Detection Module, it triggers a general trouble for external monitoring. Monitoring is performed by either communicating with the on-board IDNet IAM or by monitoring the trouble relay contacts. Detailed Earth fault status is indicated by the on-board status LEDs (see list on page 4). Product Selection Note: equipment and accessories are ordered as options for use with TrueSite Workstation upper level product selection model numbers per the System Order Reference section below. For additional TrueSite Workstation information, refer to data sheet S4190-0016. System Order Reference (to be selected per order type) Model Description 4190-8401 TrueSite Workstation, Standard Operation 4190-8402 TrueSite Workstation, Redundant Operation 4190-8403 TrueSite Workstation Fire Proprietary Supervising Station 4190-8410 TrueSite Workstation Remote Client 4190-8901 Aftermarket Hardware Additions es (agency listed for fire alarm) Model Connections Description Listings 4190-6050 Eight wired Ethernet connections 4190-6054 4190-6055 single-mode fiber optic connections Multimode fiber optic connections, 24 VDC, red cabinet; with Earth Detection on wired connections es (not agency listed for fire alarm) Model Connections Description Listings 4190-6051 Eight wired Ethernet connections 4190-6056 only; 6 W @ 10-36 VDC; single-mode fiber optic connections 6 VA @ 8-24 VAC; use Power Adapter per below 4190-6057 Multimode fiber optic connections UL 864, ULC S527; Each TrueSite Workstation Server and Client requires a 4190-6010 Transient Suppressor, see below; power is provided by a listed fire alarm power supply UL 864 Recognized component, does not include Earth detection module or cabinet Dimensions: 5-11/16 x 7-3/8 x 1-3/4 (145 mm x 187 mm x 44.5 mm) Power Adapters (select one for each 4901-6051, 4190-6056, or 4190-6057; Power Adapters are NOT for use with es 4190-6050, 4190-6054, or 4190-6055, they require connection to a fire alarm power supply) Model Description Ratings Housing Size 4190-6052 4190-6053 Wall Mount Power Adapter with 6 ft (1.8 m) cord Transient Suppressor for LAN/WAN Connection Model Description 4190-6010 Input: 120 VAC, 60 Hz, 20 W Output: 24 VAC, 650 ma Input: 240 VAC, 50 Hz, 78 ma Output: 24 VAC, 650 ma 2-1/4 W x 2-15/16 H x 1-7/8 D (56 mm x 74 mm x 48 mm) 2-5/16 W x 3-3/16 H x 1-15/16 D (58 mm x 80 mm x 49 mm) Required for agency listing; recommended for each TrueSite Workstation Server and Remote Client computer connection; mounts on rear of PC frame for desktop or rackmount computers 2 S4190-0018-3 3/2012

Fire Control Interconnection Reference For additional information, refer to Installation Instructions 579-903. to additional Remote es (if required) Remotely Located Local Control Panel Remote Fire Command Center with Remote Client Network connection Dedicated LAN for connection between es: 1. Ethernet cable, up to 328 ft (100 m) 2. Multimode fiber, up to 1.24 mi (2 km) 3. Single-mode fiber, to 9.3 mi (15 km) Connections to local fire alarm panel to supply power and monitor trouble using IDNet communications with on-board IAM or by monitoring relay contacts General System Notes: 1. Available ports can be connected to other Switches to extend distance or extend Client capacity. 2. 4190-6050 can support up to 7 clients and one server per Switch, or up to 7 clients at a remote Switch location. Connections between Fire Alarm es and TrueSite Workstation, Server or Client are wired Ethernet cable, up to 328 ft (100 m) 3. es with fiber optic ports (4190-6054 and 4190-6055) have 4 wired Ethernet ports to connect to TrueSite Workstations, and 2 fiber optic ports for connection to other Switches with fiber optic ports. (Refer to Product Selection for details.) Remote Client Control Panel 4. NOTE: Client Connections details: 4.1 With server revision 2.04, up to twenty (20) clients may be on-line simultaneously. A Network Loop Connections (up to 7 loop capacity) 4.2 Server revisions before 2.04 with remote clients allow up to ten (10) clients to be online simultaneously. TrueSite Workstation Server A NOTE: Server Ethernet connections requires a 4190-6010 Transient Suppressor assembly (designated as A, located and connected at rear of computer) Facility LAN Facility Maintenance Center Internet Connection Off-site access 3 S4190-0018-3 3/2012

Specifications Electrical Input Power Common Trouble Relay Wiring Connections for Power, IDNet Communications, and Trouble Relay Contacts Ethernet Cable Connections Ethernet Cable Data Rates Ethernet Cable Wiring Distance Fiber Optic Cable Distance (for connection between es) Fiber Optic Cable Connections Earth Detection Module Diagnostic LEDs Module Diagnostic LEDs Mechanical Cabinet Specifications Environmental Temperature Humidity Range Input Voltage 24 VDC nominal, from listed fire alarm power supply Input Current 300 ma maximum Form C contact rated 0.3 A @ 125 VAC resistive; 1 A @ 30 VDC resistive Screw terminals for 18 to 12 AWG (0.82 mm 2 to 3.31 mm 2 ) RJ-45 jacks 10 Mbps and 100 Mbps Up to 328 ft (100 m) at 10 Mbps with Cat3 cable Up to 328 ft (100 m) at 100 Mbps with Cat5 cable Model Fiber and Distance Optical Budget 4190-6054 Single-mode fiber up to 9.3 miles (15 km) 19 db 4190-6055 Multimode fiber up to 1.24 miles (2 km) 13 db Type SC connectors Color Function Description Green Power-on LED On when power is present Red Yellow Yellow IAM LED Common Earth Fault LED Earth Monitor Disabled LED, one per Ethernet Port Color Function Description Flashes to indicate IDNet communications are being received On steady when an earth fault is detected on any of the Ethernet ports If port has earth detection disabled, LED is on steady If port has earth detection enabled, LED flashes to indicate that port has an earth fault Green Power-on LED On when power is present Green Yellow Link Indicator Data Rate One per port, indicates a valid Ethernet link has been established One per port, indicates when data is transferring at 100 Mbps 13-1/2 W x 13-1/2 H x 3-5/16 D (343 mm x 343 mm x 84 mm), with locking door, lift-off hinge on left side; refer to page 4 for additional information 32 to 120 F (0 to 49 C) indoor operation only Up to 90% RH at 90 F (32 C) non-condensing 4 S4190-0018-3 3/2012

Installation Reference Model 4190-6050 (8 wired ports) shown for reference; fiber optic connections for Models 4190-6054 and 4190-6055 are made directly to the Module Box width 13-1/2" (343 mm) 11-1/2" (292 mm) Box depth = 3-5/16" (84 mm) Module Door shown for reference, 13-3/4" square (349 mm) 11-7/8" (302 mm) Earth detection module 13-1/2" (343 mm) Wiring connection terminal blocks Removable mounting plate Cable input area NOTE: Only use bottom for conduit entrance; knockouts are located at arrows 5 S4190-0018-3 3/2012

TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Tyco Fire Protection Products Westminster, MA 01441-0001 USA S4190-0018-3 3/2012 www.simplexgrinnell.com 2012 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.