DAKTON µ BOX MANUAL µbox User Manual 1



Similar documents
AUDITVIEW USER INSTRUCTIONS

HomeSeer Technologies. HomeSeer Technologies LLC 35 Constitution Dr, Suite C Bedford NH,

Release Notes. R&S ZVH4/ZVH8 Cable and Antenna Analyzer

How do I configure the wireless printer using a USB or Ethernet cable and install the printer driver in Windows?

Bluetooth HC-06 with serial port module Easy guide

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

SAPIP GUI INSTALLATION. Table of Contents

UPS Monitoring and Management Software

WIFI OBD GPS Tracker T356 User Manual

Global Water Instrumentation, Inc.

AUDITVIEW USER INSTRUCTIONS

testo easyheat Configuration and Analysis software Instruction manual

Transmitter Interface Program

LT1 Tune Kit Quick Start Guide

Installation Instructions for 9555 USB Driver

MT3339 PC Tool Operation Manual

KI6501 Data Manager. Software User Manual

Bidirectional wireless communication using EmbedRF

User Manual Software for DSL Digital Speed Switch

The following pages will help you to solve issues linked to the installation and first use of the Wintech Manager software and Wintech USB computer.

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

STIM202 Evaluation Kit

Brady IP Printer Installation Instructions

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

DAS202Tools v1.0.0 for DAS202 Operating Manual

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

PDA Software Manual For the Windows CE and Mobile Operating Systems

TR-3 Channel Editor. Software Manual

Communication with BushingGard using computer USB port

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

MANUAL FOR RX700 LR and NR

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7

Iridium Extreme TM Satellite Phone. Data Services Manual

Comdial Network Management System User Instructions

5.4.8 Optional Lab: Managing System Files with Built-in Utilities in Windows 7

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

Software Utility VNA Frequency Converter Leveling Tool Getting Started

Rogue RE-CONN Utility

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Centurion PLUS CPC4 Download Guide

Colorfly Tablet Upgrade Guide

WeatherLink for Alarm Output. Introduction. Hardware Installation and Requirements. Addendum

This guide will show you how to configure a Windows Mobile 6 PDA for Bluetooth connection to the KBM Systems OBDKey Bluetooth device.

SA-9600 Surface Area Software Manual

UM0853 User manual. 1 Introduction. M24LRxx application software user guide

User Manual. Thermo Scientific Orion

Current Monitoring Kit

ROYAL REGISTERLINK USER'S GUIDE

1. Introduction Fixture exterior view Connecting the Robe Universal Interface Software update of the fixture...

475 Field Communicator and 375 Field Communicator. VERSION 3.x UPGRADE PROCEDURES

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Instructions for Installing and Using the FOCUS DL-15 Data Transfer Software

GX-2009 Data Logger Management Program Operator s Manual

Olson Electronics Remote Power Monitoring Meter

Model 288B Charge Plate Graphing Software Operators Guide

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

BioWin Network Installation

User Manual. AS-Interface Programmer

CashFlow Programming Module CPM

DSO138 oscilloscope program upgrade method

EC500 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC500 Setup Guide - Page 1

Hydras 3 LT Quick Start

Volvo Parts Corporation Volvo Trip Manager. Contents

Hi-Speed USB 2.0 Flash Disk. User s Manual

INSTRUCTION MANUAL MONITOR REDUCE SAVE ENERGY MANAGEMENT SOFTWARE ENERGY MANAGEMENT SOFTWARE

PM1122 INT DIGITAL INTERFACE REMOTE

c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem

CM400 High Speed Cable Modem User Manual

User s Manual. Management Software for Inverter

Configuration Software User Instruction

Bluetooth to Serial Adapter

EVAL-UFDC-1/UFDC-1M-16

ISK 200 Driver Installation

Autos Limited Ghana Vehicle Tracking Business Proposal

WeatherLink for Emergency Response Teams Addendum

because we care MS910 Wireless Barcode Scanner Quick Guide Full user s manual is available on the enclosed CD. Version G

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

DG-100 Data Logger User Manual. Version 1.2

Current Monitoring Kit QUICK START GUIDE

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Datalogger Graph Software Help

Troubleshooting and Diagnostics

How to read this guide

USER MANUAL. FLASH DUPLICATOR CopyKing II CPY220

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

Instruction manual. testo easyheat Configuration and Analysis software

Installation Instructions

Ultra Thin Client TC-401 TC-402. Users s Guide

PL-1, Pocket Logger B

iminiplus PDF User Guide Version 2.0

3465 Diablo Avenue, Hayward, CA U.S.A Fax:

PMAfob Home Automation Demo

SPC-1. Single Point Controller. Operation Manual

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

How To Use An Fsm1

HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide

User Guide Win7Zilla

Transcription:

µbo User Manual 1

DAKTON µ BO: compact data logger and sensor µ BO is a sensor and a data logger together. It records data processed by DAKTON DASHBOARD with the addition of lateral and longitudinal accelerations. Together with data analysis software DATAVIEW it offers a very compact and simple way of monitoring performance of your engine, chassis and driver. µ BO CHARACTERISTICS: -Max sample frequency: 50 Hz with High rate setting, 10Hz with Low rate setting -Data memory: 4Mb -Max recording duration: > 5 hours with High rate setting -Powered through RKS DASH unit battery for more than 30 hours battery life -Data offload through PC USB and Bluetooth -Size: 35 x 35 x 15 mm -Weight: 35g -IP 67 rated SETTING UP YOUR µ-bo: There is very little to do for setting up your µ-bo as all the channels to log are automatically recognized. However you will still need to specify the following: -Circuit Name -Driver Name -Logging rate (High or Low) This information is required for the following reasons: -Directory structure for saving data is: c:\dakton\dataview\data\year\circuit\day\driver\runs data where Year is the year setup in your PC date at the time of your data offload Circuit is the circuit name specified in the µ-bo Driver is the driver name specified in the µ-bo 2

Runs data are the run data files named with progressive numbers This data saving structure is important in order to store data in the specific order. Important is also to make sure your PC date is always correct as it s used to define the directory name. Read guidelines on how to install the USB cable (Installation and setup USB cables UK.pdf) that you will find C:\DAKTON\DATAVIEW\HELP once DATAVIEW will have been installed from the enclosed CD. To connect to u-bo once USB cable fitted Following window will appear if connection established µ-bo serial number µ-bo firmware RESET button to clear run count manually µ-bo data memory status µ-bo logging rate Total accumulated run number Number of runs still to be offloaded File Comment window to add notes before offloading the specific run OFFLOAD button Longitudinal and Lateral accelerometers values. Double click on each window to zero the sensors. 3

Important to know: -When your PC date changes as a result of using the computer the day after you set up your µ-bo you will be asked if you want to update µ-bo date. If you choose YES your run count will be reset as the µ-bo assumes you are starting a new day of data collection. If your µ-bo has still got data stored from previous day to be offloaded and you want to save these data then you need to answer NO, offload the remaining data that will be stored in the old date directory. Once this is completed you should connect again to your µ-bo and this time answer YES. For a detailed explication on how to use DATAVIEW for data analysis please refer to the specific manual. HOW TO INSTALL YOUR µ-bo: As your µ-bo contains accelerometers it s very important to fit it correctly on your chassis. DAKTON provide a specific bracket to help positioning the device correctly. Ideally your µ-bo should be fitted horizontally to the ground, with the offload connector forward and µ-bo logo facing upward. A suitable position is shown below: Y Please consider that if you fit your µ-bo with a different orientation you may affect the possibility to be able to plot your circuit correctly. The minimum requirement is to make sure the lateral accelerometer is oriented along the Y axis shown above. You can still fit the box upside-down with the offload connector facing forward but in this case you will have to invert Ay while plotting your circuit. 4

Requires zeroing Requires zeroing and Lateral Acceleration sign inversion BLUETOOTH CONNECTIVITY WITH µ-bo Bluetooth connectivity is available in addition to the USB cable one. In this case the µ-bo will include a class 2 Bluetooth module that allows your PC to discover the device as µbo. Bluetooth connection range can vary from few meters up to 30 depending on positions and obstacles between your PC and your µ-bo. Make sure each Bluetooth µ-bo you have has been setup as COM port in your PC. Within DATAVIEW System Setup create a connection for each port (or for the ones you want to use) and name each connection differently (for example you can assign to it its driver name). In order to be able to connect to your µ-bo through Bluetooth: -Make sure the DASHBOARD at which the µ-bo is connected is powered. (µ- BO will not respond if the DASHBOARD is switched off). -Make sure to be in a strong Bluetooth signal range -Access Connection to Logger and select the Connection Name related to that µ-bo within the list of available connections. If while PC is connected to your µ-bo the DASHBOARD powers down, once you will exit the connection the µ-bo will stay powered for further 20 seconds. This helps avoiding having to power on the DASHBOARD in case you want to connect again. Once connected DATAVIEW will behave exactly the same as in the case of a cable connection. 5

Due to the variability of an RF connection compared to a cable one we have implemented different levels of data checks to avoid corrupted data to be offloaded and saved (see list of error messages below). LIST OF MAIN ERROR MESSAGES: NO ANSWER FROM LOGGER: your PC cannot connect to your µ-bo either due to Bluetooth COM not being configured correctly or RF coverage issues. CHECK ID ERROR: While you have been able to connect to your µ-bo, the offload command has not been correctly received due to coverage issues. CHECKSUM ERROR ABORTED OFFLOAD: While offloading a checksum error has occurred as a result of received data being corrupted. This is likely due to connection issues. Try to offload again while moving closer to your µ-bo N BYTES ERROR: Missing part of offloaded data. Try to offload again. IMPOSSIBLE TO OFFLOAD, RUN WILL BE DELETED: After 5 consecutive retries of offload without disconnecting from your µ-bo the data run will be cancelled to allow proceeding with the following. NO REFRESH PARAMS: Either while programming new settings or after offloading data the parameters could not be updated due to connections issues between PC and µ-bo. Retry offloading or repeat parameter setting. RESET ERROR: An error has occurred while resetting your µ-bo either following a new day update or following a manual reset. 6