Software Features of Auto Gas Gas Analyzer Features HC, CO, CO2, Lambda, Air Fuel, NOx. Has optional RPM and Oil Temp.



Similar documents
Emission Testers. for Diesel, Gasoline and Gas Engines. Model: MET 6.3 MET 6.1 MET 6.2 Export MDO2 LON MGT5 DITEST SPEED 2000 RPM VC2

The testo 340 What makes it The Ultimate Combustion Tuner?

InfplusWin OPERATING MANUAL

Application for an Out-Of-State Inspection of a Delaware Registered Vehicle

PDA Software Manual For the Windows CE and Mobile Operating Systems

Global Water Instrumentation, Inc.

Fleet Management - Smart, Secure and Easy

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

USB 2.0 to 10/100Mbps Ethernet Adapter UE User Manual

Gas Analyzers: INFRAGAS-196 INFRAGAS-196 PC-Module (1 to 6 Gas Available)

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

SPC-1. Single Point Controller. Operation Manual

B Test and Adjustment Jobs Engines 104, 119, 120 LH-SFI

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

Questions and Answers

United States Air and Radiation EPA420-F Environmental Protection December 1995 Agency

Portable Exhaust Gas Analyzer Operators Manual

Current Monitoring Kit

Highly efficient flue gas analyzer

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

Manual Ranging MultiMeter

M O D U L E - 7 E Model CS-Caliprompter Operator s Manual

LT1 Tune Kit Quick Start Guide

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

New OBD Smart PC Tool User Manual

Diagnosing Hydraulic Problems

User Guide. Temperature and Humidity Datalogger. Model 42280

AUTOMOTIVE DYNAMOMETER HARDWARE AND SOFTWARE

SA-9600 Surface Area Software Manual

Harrison R&D Houston, TX. OBDScan Manual Version March 22, 2005

Quick Start Guide to computer control and robotics using LEGO MINDSTORMS for Schools

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Current Monitoring Kit QUICK START GUIDE

Xantrex Solar Monitor Widget. User Guide

Lockout Specification BW Clip Maintenance-free single gas detector

DUKANE Intelligent Assembly Solutions

Electric Utility Fleet Best Practices Survey

New thermometers and accessories to grow your business

AutoRanging Digital MultiMeter

Data Analysis Software

User Manual. SenseAir Alarm. Portable carbon dioxide sensor and alarm unit for personal safety with Real Time Clock

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Model SL355 Noise Dosimeter/Datalogger

CO Low CO High O 2 NO NO 2 NOx SO 2 H 2 S CxHy CO 2 LANCOM III

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Hygro-Thermometer + InfraRed Thermometer Model RH101

VEHICLE SERVICE DISPENSING SYSTEMS

February 2015 Dealer Service Instructions for: Customer Satisfaction Notification R01 Reprogram Transmission and Powertrain Control Modules

Online Infrared Flue Gas Analyzer Gasboard 3000

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

User's Guide. Integrating Sound Level Datalogger. Model Introduction

EXTENDED PREPAID PLANS PLANS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

How To Use A Powerpoint 3D (Powerpoint) With A Car (Powerstation) With An Mp3) (Powerplant) (Ppl) (Control) (Programme) (Computer) (Manual) (Aut

VeHiCle diagnostics the autocom way

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Lectric Enterprises 5905 Sprucepine Drive Winston Salem, NC Telephone

Hydras 3 LT Quick Start

GAS ANALYZER INFRAGAS INFRAGAS-205 INFRAGAS-209 INFRAGAS-305 INFRAGAS-309

Table Of Contents

ExStik TM ph Waterproof Meters

Kane Automotive. Gas Analyser Manual for models; Auto 2-2; 4-2 & 5-2; Auto 4-1 & 5-1

5000V Graphical Megohmmeter Model 5070

1. SAFETY INFORMATION

Point of view HDMI Smart TV dongle Mini RF Keyboard

A-Series Data Loggers PRODUCT MANUAL

UNITED STATES AND U.S. TERRITORIES AND POSSESSIONS EXCEPT PUERTO RICO 2016 / WARRANTY & MAINTENANCE MANUAL

Aeroqual Connect and Cloud

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

User s Manual C R Y S T A L. engineering corporation

Autos Limited Ghana Vehicle Tracking Business Proposal

Marine after-treatment from STT Emtec AB

Installing USB Drivers With Microsoft Windows XP

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TECHANGLE November 30, 2005 TECHNICAL PAGE

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

Fleet Technician I Fleet Technician II Fleet Technician III

OPERATION MANUAL INFRARED THERMOMETER

Emission Control Systems Warranties

Instruction Manual Dräger MSI ALV

Parts List. Navigation

Multifunction HVAC and IAQ Meter

The PACE5000 Modular Pressure Controller/Indicator

Welch Allyn Vital Signs Monitor 300 Series

Laptop USB KVM Switch USER MANUAL CS661

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Measurement Solutions for Refrigeration Technology.

1. SAFETY PRECAUTIONS AND WARNINGS

Part 1 Product introduction 2. Part 2 Features 3. Part 3 Safety notes 4. Part 4 Quick user s guide 5. Part 5 Operation notes 7

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Medical Air Systems: Scroll

Speedlink software will run on Windows NT, Windows 7, and Windows 8; it will run on both 32 byte and 64 byte versions of Windows.

HomeSeer Technologies. HomeSeer Technologies LLC 35 Constitution Dr, Suite C Bedford NH,

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Transcription:

Auto Gas Ultimate Model Shown Above Software Features of Auto Gas Gas Analyzer Features HC, CO, CO2, Lambda, Air Fuel, NOx. Has optional RPM and Oil Temp. Durable high strength aluminum case with all of the connections on the inside of the case. With this unique design, all of the connections are protected from accidental droppage. User friendly design to make it easy to use without extensive computer knowledge. Automatic water removal to remove water from the vehicle's exhaust as the analyzer runs. Some systems require you to shake out the water out of the filter. Pocket Gas does this automatically. The water is removed continuously as the system is operated to eliminate frequent purging. Unique float system to prevent damage to analyzer if exhaust sample probe lands in water. Zero air port which helps guaranty accurate emissions readings and allows the gas analyzer to zero without removing the sample probe from the vehicles exhaust pipe. Accurate system meets and exceeds accuracy specifications of ASM/BAR 97, OIML, BAR90, etc. Autologic's 48 hour service guaranty. If your unit requires service, we will repair the unit in 48 hours at our factory. If we cannot repair it in 48 hours, we provide a loaner until service can be completed. Universal Power supply for 90-230 VAC, 50-60 Hz. 12 Volt Cigarette lighter plug and 12 volts battery clamps included. 25 foot sampling hose and probe included outfitted with quick disconnects. High strength armor cloth carrying case for storage of all components. Use with any Laptop PC running Windows or with PC desktop configuration. Fast 2 minute warmup. Page 4

Large digital meters with pull-down lists for easy viewing of gases from any distance. One touch click for data recording. Record data over long profiles second by second or change interval for tests like engine brake in. International software with English and Metric units. Built in language translation allows software to be translated without programming knowledge. (Includes most languages. Consult AutoLogic for more details.) Data saved in industry standard relational database format. Great for research and development facilities who wish to record emissions data. Great for fleets testing with many cars. Often a technician may start work on one vehicle and move to the next vehicle before finishing the first. This database stores an almost unlimited amount of data from many vehicles so that one technician may work on many vehicles or many technicians may work on many vehicles simultaneously. All emissions are tied to the customer and vehicle allowing for recall later on for comparison purposes. Two speed idle (TSI) test in addition to digital readout of emissions. This enables easy comparison to state inspection test results. This also provides garage owners and technicians with an easy way to assure that everyone is testing the vehicle the same way before and after repairs. Data is collected automatically and the technician is guided through the test with clear on screen prompts. Page 5

Real time graphing of emission data allows for viewing of trends and quick comparison of signals. Runs on any PC running Windows 95, Windows 98, Windows NT, Windows ME, Windows 2000 and Windows XP with one available com port. Gas Measurement Ranges Range Resolution HC 0-30000ppm 1ppm CO 0-15% 0.001 vol% CO2 0-20% 0.01 vol% O2 0-25% 0.01 vol% NOx 0-5000ppm 1ppm Temperature: 0-50 degrees C oper., -20 to 70 deg. C storage Humidity: Up to 95% non-condensing Altitude -300 to 2,500 m Vibration 1.5 G sinusoidal 5-1000 Hz. Shock 1.22m drop to concrete floor (gas analyzer) Response time 0-90% <= 8 seconds for NDIR measurements Optional Tachometer, Gasoline, RPM probe, Oil Temperature AutoLogic s Digital Tachometer (available for Auto Gas Model only) measures vehicle engine RPM and engine temperature, conveniently and easily through non-contact or contact measuring systems. Tachometer instrument made of high impact ABS plastic. Interfaces with your desktop or laptop PC to display readings on your PC screen. SPECIFICATIONS RPM Sensor Temperature Sensor RPM Measuring Ranges Temperature Measuring Ranges #1 Probe RTB Probe 0 5000 RPM 0-150 Degrees C Page 6

Display for RPM & Temperature Non-Contact Measuring System Contact Measuring System RPM Accuracy Temperature Accuracy Warranty Displays Readings on your PC screen Battery Cables Spark Plug Connector Adapters + 10 RPMs in all ranges + 2 degrees in all ranges Instrument: 1 years Probes & Hoses: 90 days Software Feataures of Pocket Gas TM Measures HC, CO, CO2, O2, NOx (5 gas version), Air Fuel, Lambda Meets or exceeds BAR 97, ASM, OIML Class 1, and BAR90 Adjustable time between readings for driving profiles and detailed diagnostics Powered from power supply, vehicle battery or cigarette lighter Robust touch screen software design keeps hands on steering wheel while emissions data is recorded Detachable display allows easy viewing at all angles Advanced technology Windows CE design Contact manager gives quick storage and retrieval of customer s names and phone numbers Large amount of emissions and customer data is stored. Look up the readings days later after testing for diagnostics or comparison. *To do list software tracks important daily tasks Full BAR97 specification database to enable easy comparison of test results to pass / fail limits Scheduling software included to track daily work schedules, reminders, and jobs to do Easy to use menus and buttons make operation simple Uses easily end user maintainable parts to eliminate expensive service requirements Light weight, easy to transport (less than 6 lbs) Professional Report Printing Via Infrared port with optional full size mobile printer Page 7

Pocket Gas contains an BAR97 / EPA recommended pass fail specifications database to tell you what a certain make and model of vehicle should have for emissions standards. Pocket Gas contains real time graphing of gases so trends in gas data can be easily seen. Pocket Gas features automatic water removal to remove water from the vehicle's exhaust as the analyzer runs. Some systems require you to shake out the water out of the filter. Pocket Gas does this automatically. The water is removed continuously as the system is operated to eliminate frequent purging. Pocket Gas has a unique float system to prevent damage to the analyzer if the exhaust sample probe lands in water. Pocket Gas has a zero air port which helps guaranty accurate emissions readings and allows the gas analyzer to zero without removing the sample probe from the vehicles exhaust pipe. Pocket Gas has a durable high strength aluminum case with all of the connections on the inside of the case. With this unique design, all of the connections are protected from accidental droppage or exposure to the elements. Pocket Gas has an extensive customer and vehicle database. Readings can be recorded to a particular customer and vehicle with a very large amount of storage. Technicians can go back days, weeks, months and years later and see the results from vehicles by CUSTOMER NAME AND VEHICLE LICENSE. Pocket Gas has built in demo / training mode for training Technicians The Pocket PC allows you to easily add Pocket OBD without buying another display so you have a superior combination of OBD for 1996 and newer vehicles and portable gas testing for 1995 and older vehicles. This is a superior tool for fixing I/M failures. Universal Power supply for 90-230 VAC, 50-60 Hz. 12 Volt Cigarette lighter plug and 12 volts battery clamps included. 25 foot sampling hose and probe included outfitted with quick disconnects. High strength armor cloth carrying case for storage of all components.. Page 8