Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Similar documents
Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

AppNote 6/2011. Determination of Pain Management Drugs using Automated Disposable Pipette Extraction and LC-MS/MS KEYWORDS ABSTRACT

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Improved Method for the Analysis of 31 Drugs of Abuse in Oral Fluid samples using the Thomson extreme FV by LC-MS/MS

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Opiates in Urine by SAMHSA GC/MS

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

What Does the Drug Test Tell Us

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Practical Aspects of Drug Testing in Human Hair

DUI in Southern Ohio MATT 2006

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

LC-MS for Pain Management Support. Gwen McMillin, PhD, DABCC(CC,TC) University of Utah ARUP Laboratories

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

LC-MS for Pain Management Support

AppNote 4/2014. Prep-and-Shoot : The Completely Automated Workfl ow for the Hydrolysis and Analysis of Urine Samples by LC/MS/MS.

Overview. Purpose. Methods. Results

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Toxicology CPT Code Changes for 2016

Cliquid ChemoView 3.0 Software Simple automated analysis, from sample to report

LC-MS/MS, the new reference method for mycotoxin analysis

LC-MS/MS for Chromatographers

Simultaneous Quantitation of 78 Drugs and Metabolites in Urine with a Dilute-And-Shoot LC MS-MS Assay

PtProtect Pain Medication Management Program Monitors Patient Compliance

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

Interagency Guideline on Opioid Dosing for Chronic Non-cancer Pain (CNCP)

Urine Drug Testing Methadone 101 Methadone for hospitalists

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Successful Sample Preparation Strategies for LC/MS/MS Analysis of Drugs in Complex Biological Matrices for Forensic Toxicology Applications

Indiana State Department of Toxicology 2012 Annual Report

The potential of oral fluid as a specimen in various drug testing programs

SIMULTANEOUS QUANTITATIVE DETERMINATION OF OPIOID DEPENDENCY TREATMENT DRUGS IN HUMAN URINE USING UPLC/MS/MS

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

FREQUENTLY ASKED QUESTIONS Oral Fluid Drug Testing with Oral-Eze

This is the written version of our Hot Topic video presentation available at: MayoMedicalLaboratories.com/hot-topics

A Streamlined Workflow for Untargeted Metabolomics

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Determination of Tapentadol and its Metabolite N

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

What Americans Believe. Grant Beardsley, MS, MT(ASCP) 10/12/2015. Interpreting: Urine Drug Test Results in Chronic Opioid Therapy and Drugs of Abuse

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

How To Test For Contamination In Large Volume Water

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *

Interlaboratory Studies on the Analysis of Hair for Drugs of Abuse: Results from the Fourth Exercise

Hillsborough Community College - Ybor City Campus 1025C Laboratory Exercise 9: Testing Urine for the Presence of Drugs Introduction

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Drug Utilization Is On The Rise

CUT-OFF CONCENTRATIONS FOR DRUGS OF ABUSE IN SALIVA FOR DUI, DWI OR OTHER DRIVING-RELATED CRIMES

Analysis of Drugs by using the Ultra Inert Inlet Liners with Wool

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Collection Instructions for ARUP Drug Screen Kit #49204

Confirmation by Triple Quadrupole LC/MS/MS for HHS-compliant Workplace Urine Drug Testing

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Innovative vs Traditional

Appropriate utilization of drug tests for pain management patients

SOLID PHASE EXTRACTION APPLICATIONS MANUAL

Drug Testing to Support Pain Management

Urine Drug Testing. Why drug test? Set the Standard!

LC Application Note.

FREQUENTLY ASKED QUESTIONS Hair Testing

CLEAN-UP PROCESS FOR MASS SPECTRAL STUDY OF AMPHETAMINES IN PUTREFIED BODY MATERIALS

Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS

Prevalence and risk of driving under influence of psychoactive substances: Results from epidemiological studies

Transcription:

TECHNICAL NOTE Toxicology Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications Introduction The resolving power of chromatography combined with the sensitivity and selectivity of mass spectrometry results in a an extremely useful analytical technique. GC/MS has long been the technique of choice for identification and quantification of analytes in complex mixtures. Because of its utility, extreme efforts are often employed in sample preparation to make difficult compounds amenable to GC/MS analysis. This sample preparation often includes liquid-liquid extraction (LLE), solid-phase extraction (SPE), and/or derivatization. Liquid chromatography interfaced to mass spectrometry was the natural progression of chromatographic/mass spectral techniques. However, early attempts at interfacing LC to mass spectrometry had very limited capabilities. The introduction of electrospray ionization helped LC/MS/MS develop from a research tool into a routine technique. Further developments in electronics and computers have resulted in the economical benchtop instruments that are present in a majority of analytical labs today. LC/MS/MS is a very complementary technique to GC/MS. Many of the compounds that are difficult to analyze by GC/MS such as amines and semi-volatile compounds are ideal candidates for LC/MS/MS. By switching assays from GC/MS to LC/MS/MS, many advantages can be realized. First of all, GC is most commonly interfaced to single quadrupole mass analyzers. By moving from single MS to tandem MS/MS, selectivity is greatly enhanced, and therefore improved detection and quantitation limits can be achieved. Secondly, two limitations with GC/MS are that the sample had to be in an organic injection solvent and derivatization is often necessary to improve peak shape, ionization, and/or volatility. LC/MS/MS typically does not have these two requirements, and therefore sample preparation can be greatly simplified. Although sample preparation can include solid-phase extraction (SPE) or liquid-liquid extraction (LLE), it can be as simple as direct injection, dilution, or protein precipitation. By minimizing the amount of sample handling required, savings of both time and money can be attained. Additionally, decreasing the number of preparation steps can minimize areas where errors or contamination TIC 15, 1, 5, Ion 371 (37.7 to 371.7): 213.D\data.ms 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 9. 9.5 THC THC 1, 5, 3, 2, 1, Ion 386 (385.7 to 386.7): 213.D\data.ms 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 9. 9.5 Ion 387 (386.7 to 387.7): 213.D\data.ms 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 9. 9.5 5, 3, 2, 1, Ion 473 (427.7 to 473.7): 213.D\data.ms 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 9. 9.5 Ion 474 (473.7 to 474.7): 213.D\data.ms 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 9. 9.5 Figure 1. Chromatogram of a low QC (1 ng/ml) analyzed using GC/MS. The total run time was 1 minutes.

can be introduced. Several assays were transferred from GC/MS to LC/ MS/MS and the methods and data compared and contrasted. Unless otherwise stated, all data were collected using an Applied Biosystems/ MDS Analytical Technologies API 32 LC/MS/MS system. THC in Blood Cannabis is one of the most commonly used drugs in the world and is illegal in most countries. The active ingredient is Δ9-THC, which is the target analyte along with its major metabolite, 11-nor-9-carboxy-Δ9- tetrahydrocannabinol (). An LC/MS/MS method for analysis of THC and in blood was developed to replace an existing GC/MS method. For GC/MS, sample preparation consisted of solid-phase extraction followed by derivatization and sample concentration. Use of LC/MS/MS allowed omission of the derivatization step. Representative GC/MS and LC/MS/MS data from a low QC (1 ng/ml) are shown in Figures 1 and 2, respectively. Note the reduction in run times: 1 minutes for the GC/MS analysis and 4.5 minutes for the LC/MS/MS analysis. The long GC/MS run time was necessary to bake out the GC column of excess derivatizing reagent. The LLOQ for LC/MS/MS was also better at.5 ng/ml, versus 2 ng/ml observed for GC/MS analysis. By switching the analysis of THC and its metabolite from GC/MS to LC/MS/MS, sample preparation was simplified and run times shortened, resulting in significant time savings. Furthermore, the LLOQ improved by a factor of 4x. Opiates in Urine Opiates are a class of drugs frequently prescribed for pain relief. However, these drugs are often illegally obtained and abused. Because of the high prevalence of illicit use, frequent testing may be required. This method analyzes urine for the presence of morphine, oxymorphone, hydromorphone, codeine, oxycodone, hydrocodone, and 6-monoacetylmorphine (6-MAM). TIC: from Sample 5 (1. std) of 18.wiff (Turbo Spray) 2.5e5 2.e5 1.5e5 1.e5 5.e4. 8.6e4 8.e4 7.e4 6.e4 5.e4 4.e4 3.e4 2.e4 1.e4. 1 ml urine sample 1.65 2.6 2.96.5 1. 1.5 2. 2.5 3. 3.5 4. 3 6 89 119 147 177 26 236 XIC of +MRM (4 pairs): Period 2, 315.2/193.2 amu from Sample 5 (1. std) of 18.wiff (Turbo Spray) 5824 5 4 3 2 1 2.62 Vortex and incubate for 12 min at 6 C; cool to room temp. Vortex and centrifuge Max. 2.6e5 cps..2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 13 25 36 48 6 72 83 95 17 119 13 2.6 Max. 8.6e4 cps. 2.4 2.5 2.6 2.7 2.8 2.9 3. 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4. 4.1 4.2 4.3 4.4 6 12 18 24 3 36 42 48 53 59.3 65 71 77 83 89 95 11 17 112 118 124 XIC of -MRM (4 pairs): Period 1, 343.1/299.3 amu from Sample 5 (1. std) of 18.wiff (Turbo Spray) TIC THC Max. 5824. cps. Figure 2. Chromatogram of a low QC (1 ng/ml) analyzed using LC/MS/MS. The total run time was 4.5 minutes, which is less than half the time required for GC/MS analysis. 1.65 2.7 A comparison of the sample preparation protocols for GC/MS and LC/MS/MS is shown in Figure 3. For GC/MS, sample preparation consisted of hydrolysis, derivatization, and an extensive SPE cleanup procedure. The steps highlighted in blue were omitted for LC/MS/MS analysis and sample preparation was reduced to hydrolysis, centrifugation, and sample dilution. Also note that GC/MS required a sample volume of 1 ml that was subsequently concentrated 1x for analysis. For LC/MS/MS, the sample volume was reduced to.25 ml with a dilution factor of approximately 5x, demonstrating the improved selectivity and sensitivity of LC with tandem mass spectral detection. By eliminating SPE clean-up, significant reductions in both time and consumable costs were achieved. Add 1 μl IS Add 1 μl β-glucuronidase (1, units/ml) Add 2 ml.1 M sodium acetate buffer (ph 4.) 25 μl urine sample Add 75μL IS Add 175 μl of 5% HCl and 125 μl of 1% methoxyamine HCl Vortex Add 21 μl of NaOH Vortex and incubate for 12 min at 6 C; cool to room temp. Add 85 μl of DI water 13-step SPE Process Evaporate to dryness under N 2 at 3 C Reconstitute in 1 μl EtOAc Inject Time savings were not limited to the front-end sample preparation, but also to the instrumental analysis. Total run time was reduced by 4%, dropping from 1 minutes for the GC/MS method to 6 minutes for the LC/MS/MS method. Also, due to the sensitivity and derivatization requirements, 6-MAM was a separate, dedicated GC/MS method. However, all opiates, including 6-MAM, were included in the LC/MS/MS extraction and analytical method. Figure 4 shows a representative chromatogram at 5 ng/ml, which was the working LLOQ for this method. Add 5 μl.1 M sodium acetate buffer (ph 4.) Add 2 μl β-glucuronidase (1, units/ml) Vortex and centrifuge Figure 3. Sample preparation for analysis of opiates in urine. (Top) GC/MS sample preparation protocol. The steps highlighted in blue could be omitted when LC/MS/MS analysis was used. (Bottom) Sample preparation protocol for LC/MS/MS analysis uses a smaller sample volume and is much simpler than the GC/MS preparation. Inject

XIC of +MRM (21 pairs): 3./199.2 Da from Sample 1 (5ng/ml) of 586-8_pos.wiff (Turbo Spray), Smoothed Max. 245. cps. 24 22 2 18 16 14 12 1 8 6 4 2 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3. 3.1 3.2 3.3 3.4 3.5 3.6 Figure 4. Representative chromatogram for opiates in urine. Data shown are from a 5 ng/ml calibrator, which is the LLOQ for this assay. The linear range was 5 1, ng/ml. 3.1 3.2 6-MAM When results from the LC/MS/MS method were compared with the validated GC/MS method, there was a correlation of 9%. The interand intra-day CVs were <1% for both the high and low QCs. The data quality was also greatly improved, as measured by a reduction in the sample re-run rate, which dropped from an average of 5 samples per batch of 3 samples to 1 sample per batch of 3. By transferring the analysis of opiates in urine to an LC/MS/MS method, significant advantages were realized while maintaining and even improving data quality, which greatly reduced the number of samples requiring repeat analysis. Previous use of GC/MS required two runs and long, extensive sample preparation protocols for complete panel analysis. When analyzed using LC/MS/MS, sample size was reduced, sample preparation simplified, run time shortened, and only one run was necessary. These benefits of LC/MS/MS resulted not only in time savings but also significant reductions in consumable and labor costs. Benzodiazepines in Urine Benzodiazepines are frequently prescribed for sleep disorders, anxiety, stress, and several other conditions. Because of the high prevalence of these drugs, they are often involved in illicit use and forensic cases. Traditionally, benzodiazepine screening has been performed utilizing immunoassay with GC/MS confirmation and quantification. GC/MS analysis of benzodiazepines requires hydrolysis followed by extensive SPE clean-up and derivatization in order to detect the low concentrations, similar to the sample preparation for opiates. Figure 5. Total ion chromatogram for GC/MS analysis of ten benzodiazepines. Total run time was 12 minutes per sample. XIC of +MRM (39 pairs): 286.1/121.1 Da from Sample 4 (STD URINE 5 ng/ml) of 28927_Curves.wiff (Turbo Spray), Smoothed Max. 1.6e4 cps. 1.6e4 1.5e4 1.4e4 1.3e4 1.2e4 1.1e4 1.e4 9. 8. 7. 6. 5. 4. 3. 2. 1.. 7 - Aminoclonazepam 1.97 7 - Aminoflunitrazepam Midazolam Flurazepam.62.78 2.37.42 1.59 1.76 1.33 2.76 3.12 3.32 1.13 2.58 3.54 3.77.29 3.84 4.19 4.49 5.74 5.87 4. 4.5 6..5 1. 1.5 2. 2.5 3. 3.5 5. 5.5 Figure 6. Extracted ion chromatograms for analysis of 14 benzodiazepines using LC/MS/MS. Not all analytes are labeled in the figure. Data shown were obtained from a 5 ng/ml calibrator, and the LLOQ for all analytes was 1 ng/ml or better. Total run time for this analysis, including column equilibration, was about 8 minutes. Oxazepam Clonazepam Flunitrazepam Temazepam Diazepam Alprazolam For GC/MS analysis of benzodiazepines, 1 ml of urine was hydrolyzed, cleaned up using a multi-step SPE procedure, derivatized, and reconstituted in.1 ml (a 1x concentration) prior to analysis. Sample preparation for LC/MS/MS analysis started with.5 ml of urine and consisted of hydrolysis, centrifugation, and 1x dilution, similar to the preparation procedure outline in Figure 3. Total analytical run time was again significantly reduced, as illustrated in Figures 5 and 6, which show chromatograms from GC/MS and LC/MS/MS analyses, respectively. When GC/MS analysis is utilized, total analytical run time is about 12 minutes, versus 8 minutes using LC/MS/MS. As with the opiate analysis, transferring the method from GC/MS to LC/MS/MS resulted in several advantages: simplified sample preparation, including omission of time-consuming SPE and derivatization steps, and shorter analytical run time. Analysis Across Drug Classes One of the most significant advantages of being able to use a simple, relatively generic sample preparation is that it allows analysis of drugs across multiple compound classes in a single method. An example of this multi-class drug analysis is demonstrated in Figure 7, which shows analysis of 9 opiates and 1 benzodiazepines in 6 minutes. Sample preparation was the same as depicted in Figure 3. The ability to analyze across drug classes can be extended to confirmation panels or comprehensive drug screening. Figure 8 shows a representative chromatogram of a confirmation panel for 3 commonly abused illicit and prescription drugs. Even with a high number of analytes, precision and accuracy can be maintained by proper method setup and use of appropriate internal standards (Figure 9). Although Figure 9 presents statistics for morphine, statistics for other compounds were of similar quality. Figure 1 shows a multi-

target drug screen for over 7 drugs using an Applied Biosystems/ MDS Analytical Technologies 32 QTRAP instrument. The method takes advantage of the hybrid triple quadrupole/linear ion trap capabilities of the instrument by using the selective MRM mode to detect the target compounds, and the sensitive full-scan capabilities of the ion trap to obtain full-scan MS/MS spectra of the analytes. These spectra can be searched against a library for compound identification and confirmation. A representative report showing library confirmation for temazepam is presented in Figure 11. Summary Many toxicological analyses are being transferred from GC/MS to LC/MS/MS to take advantage of: reduced sample preparation and handling; improved detection limits; and faster analytical run times. This reduction in sample handling, consumables, and time helps reduce costs and minimize potential for errors or contamination. Furthermore, because the sample preparation protocols are relatively generic, it is easy to analyze drugs across multiple classes, resulting in even greater time savings. LC/MS/MS can be utilized to analyze multiple drug classes in a single assay for quantitation/confirmation, as well as comprehensive drug screening. Because of these advantages, as well as the versatility of hybrid instruments, the use of LC/MS/MS is rapidly increasing in the forensics toxicology field and is quickly becoming the analytical technique of choice. XIC of +MRM (71 pairs): 278.2/234.2 amu Expected RT: 4.4 ID: EDDP 1 from Sample 9 (Calib 3: dil 5x) of Test Pos Stock A smrm_sept... 3.e5 2.8e5 2.6e5 2.4e5 2.2e5 2.e5 1.8e5 1.6e5 1.4e5 1.2e5 1.e5 8.e4 6.e4 4.e4 2.e4 Morphine Hydromorphone Benzoylecgonine Methamphetamine MDMA Norfentanyl Max. 3.1e5 cps.. 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8 3. 3.2 3.4 3.6 3.8 4. 4.2 4.4 4.6 4.8 5. 5.2 5.4 Figure 8. Analysis of a 5 ng/ml calibrator for 3 illicit and prescription drugs in urine. Total run time was 6.5 minutes. Not all drugs are labeled in this figure. Tramadol Cocaine Fentanly EDDP 4.47 Methadone Acknowledgments The author would like to thank Albert Elian, Massachussetts State Police; Timothy D. Dahn, AIT Laboratories; and Sumandeep Rana, Redwood Toxicology for their contribution of data and/or samples. XIC of +MRM (57 pairs): 233.1/84.1 amu Expected RT: 1.9 ID: Norfentanyl 1 from Sample 16 (5 ng/ml, rep 1) of 8 Cal Curve 1.wiff Max. 5.e4 cps 5.e4 1.93 4.5e4 Norfentanyl 4.e4 3.5e4 3.e4 2.5e4 2.e4 1.5e4 1.e4 5. Morphine Oxymorphone Hydromorphone Codeine 6-MAM Hydrocodone 7-Aminoclonazepam Fentanyl Oxazepam Desalkylflurazolam Temazepam Diazepam Figure 9. Data quality for a multi-analyte panel was maintained as supported by the precision, accuracy, and linearity. Results for morphine are displayed, and similar results were obtained for other analytes, though the upper limit of quantification was lower than 5, ng/ml for some compounds...5 1. 1.5 2. 2.5 3. 3.5 Figure 7. Combined benzodiazepine and opiate analysis. Nine opiates and ten benzodiazepines were analyzed in a single method. Data shown are from a 1 ng/ml calibrator (1 ng/ml for fentanyl), and total run time was 6 minutes. The LC conditions used for this analysis are different from the conditions used for the benzodiazepine and opiate analyses previously discussed.

Figure 1. Multi-target LC/MS/MS screening for >7 drugs. MRM mode was combined with dependent full-scan MS/MS spectral acquisition. The MS/MS spectra were searched against a library for compound identification and confirmation. Figure 11. Identification of temazepam from a urine sample analyzed using the 7-compound multi-target LC/MS/MS screening method. The MS/MS spectrum from the unknown sample is on top and the library spectrum is on the bottom. For Research Use Only. Not for use in diagnostic procedures. The trademarks mentioned herein are the property of either Life Technologies Corporation, Applied Biosystems/MDS Analytical Technologies or otherwise, their respective owners. 29 Applied Biosystems LLC and MDS Inc. Joint Owners. All Rights Reserved. Information subject to change without notice. Printed in the USA. 1/29 Publication 114AP19-1 B-8921 Headquarters 85 Lincoln Centre Drive Foster City, CA 9444 USA Phone 65.638.58 Toll Free 8.327.32 www.appliedbiosystems.com International Sales For our office locations please call the division headquarters or refer to our website at www.appliedbiosystems.com/about/offices.cfm