Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999



Similar documents
MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Purchasing a cardiac CT scanner: What the radiologist needs to know

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

Assessing Radiation Dose: How to Do It Right

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

How To Improve Your Ct Image Quality

The disclaimer on page 1 is an integral part of this document. Copyright February 23, 2016 by AAPM. All rights reserved.

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

Chest CT protocols. Mannudeep K. Kalra, MD, DNB. Dianna D. Cody, PhD. Massachusetts General Hospital Harvard Medical School

The disclaimer on page 1 is an integral part of this document. Copyright March 1, 2016 by AAPM. All rights reserved.

Cone Beam Reconstruction Jiang Hsieh, Ph.D.

Copyright March 1, 2016 by AAPM. All rights reserved.

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver /9/07) by M. Jensen and J. E.

Table of Contents. Scan acquisition and user interface basics. Dose modulation and reduction tools. Multi-Slice Detector Geometry

State-of-the-Art Technology in Cardiac CT

Low-dose CT for Pulmonary Embolism

Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation.

Cynthia H. McCollough b) and Michael R. Bruesewitz Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

SWABIK Project. Software Tools for DICOM Media Exchange in Clinical Research: the. SWABIK Project

Fundamentals of Cone-Beam CT Imaging

The disclaimer on page 1 is an integral part of this document. 1. Copyright December 14, 2015 by AAPM. All rights reserved.

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Techniques and Applications of Automatic Tube Current Modulation for CT 1

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Development of SCENARIA New Version Software MEDIX VOL. 62 P.32 P.35

Digital Breast Tomosynthesis QC Requirements

PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad.

GE Healthcare. DoseWatch. Gathering Radiation Dose Data

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

American College of Radiology CT Accreditation Program. Testing Instructions

The effect of pitch in multislice spiral/helical CT

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

Sistemas de reducción de dosis en CT para pediatría. Nuevos avances Ángela de Pinto Siemens CT Business Manager

3/12/2014. Disclosures. Understanding IAC CT Accreditation. Outline. Learning Objectives. Who is the IAC?

Computed Tomography Instrumentation. Ian A. Cunningham. Data-Acquisition Geometries. Ian A. Cunningham

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

Multislice Computed Tomography: Basic Principles and Clinical Applications

A d v a n c e d 1 2 8

5 Factors Affecting the Signal-to-Noise Ratio

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

Tumor. An Brief Introduction to 4D CT Scanning. Outline. Three Types of Motion Artifacts. CT Artifacts in Free Breathing 3D Scan

Data. microcat +SPECT

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Siemens Computed Tomography

GE Healthcare. Revolution EVO. More than just high tech. Higher purpose.

MEDICAL IMAGING 2nd Part Computed Tomography

Acknowledgement. Diagnostic X-Ray Shielding. Nomenclature for Radiation Design Criteria. Shielding Design Goal (Air Kerma):

Chest 1: Pulmonary Nodule Follow-up: Low-Dose Helical CT (Unenhanced) (Non-metastatic) Gantry Rotation Time. mas (Reg-Lg) 40-80

Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose

Image Analysis for Volumetric Industrial Inspection and Interaction

X-ray Imaging Systems

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Multi-slice Helical CT Scanning of the Chest

Mx8000 IDT 16 provides dose control methodologies like DoseRight ACS (Automatic Current Selection) and DoseRight DOM (dynamic dose modulation).

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems

A Three-Dimensional Correlation Method for Registration of Medical Images in Radiology

Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro.

Multi Detector Row CT Systems and Image- Reconstruction Techniques 1

Proton tracking for medical imaging and dosimetry

M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy

SITE IMAGING MANUAL ACRIN 6698

CT Image Reconstruction. Terry Peters Robarts Research Institute London Canada

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Protocol Management and Review Strategies The MD Anderson Experience

GE Healthcare. Great treasures in small places. BrightSpeed Elite

Brilliance CT 64-channel confi guration

Two years ANR Post Doctorate fellowship Mathematics and Numerics of Dynamic Cone Beam CT and ROI Reconstructions

0 EC V-,) 133 Lj9a

Cardiac CT for Calcium Scoring

DENTAL Cone beam 3D X-RAY SYSTEM with

32-Channel Head Coil Imaging at 3T

The power of Multislice CT Philips MX 6000 Dual

Automated Pose Determination for Unrestrained, Non-anesthetized Small Animal Micro-SPECT and Micro-CT Imaging

Practical exercise: Effective dose estimate in CT

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Development of High Speed Oblique X-ray CT System for Printed Circuit Board

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Industrial X-ray for Nondestructive Testing Unrestricted Siemens AG All rights reserved

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

IAEA HUMAN HEALTH SERIES

Optimization of image quality through online motion correction

Performance testing for Precision 500D Classical R/F System

DICOM Correction Item

Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

ADROTERAPIA A MEDAUSTRON

BIG data big problems big opportunities Rudolf Dimper Head of Technical Infrastructure Division ESRF

Multislice CT: Current Technology and Future Developments

High-accuracy ultrasound target localization for hand-eye calibration between optical tracking systems and three-dimensional ultrasound

kv-& MV-CBCT Imaging for Daily Localization: Commissioning, QA, Clinical Use, & Limitations

Transcription:

Spiral CT: Single and Multiple Detector Systems AAPM Refresher Course Nashville, TN July 28,1999 Mike McNitt-Gray, PhD, DABR Assistant Professor UCLA Radiological Sciences mmcnittgray@mednet.ucla.edu

X-Ray CT Systems All Use: Thinly Collimated X-Ray Beam Multiple Views Detectors to Collect X-Ray Photons Data Acquisition System Image Reconstruction Algorithm (Filtered Back Projection) Film/Monitors To Display Axial Slices

3rd generation rotate-rotate 4th generation rotate-stationary

Conventional CT Systems (GE Hi-Lite Advantage) : Tube Rotates Around Stationary Patient (Table is Incremented Between Acquisitions) All Views in a Slice are at Same Table Position Power to X-Ray Tube via Cord Scan CW and CCW to Wind/Unwind Cord Interscan Delays: 3.5 Seconds Between Slices

Spiral (Helical) CT Systems Kalender s 1990 article was titled : Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Differences from Conventional: Continuous Tube Rotation - No Interscan Delays (Power to X-ray Tube via Slip Ring) Continuous Table Motion as Tube Rotates Each View is at a DIFFERENT Table Position Form Images by Synthesizing Projection Data via Interpolation

Data Acquisition and Image Formation Some Data Acquisition Parameters Behave as Always (kvp, mas, Recon. Filter) Others (Collimation, Table Speed/Pitch, and Interpolation Algorithm) Interact to Influence Image Formation and Image Quality However, Image Formation has its own independent parameter- reconstruction interval

Data Acquisition Pitch = Table Movement per Rotation Slice Collimation (Essentially a measure of Relative Speed) Contiguous Spiral Pitch = 1 (10 mm / 10 mm) Extended (Non-Contiguous) Spiral Pitch = 2 (20 mm/ 10 mm) Overlapping Spiral Pitch = 1/2 ( 5 mm / 10 mm)

Pitch=1; Contiguous Spiral Width of Spiral Path (From Collimation) Center of Spiral Path Direction of Continuous Patient Transport 0 z, mm t, sec

Pitch=2; Extended Spiral Width of Spiral Path (From Collimation) Center of Spiral Path Direction of Continuous Patient Transport 0 z, mm t, sec

Image Formation Collect Projection Data These Data are NOT all at same table position, so: Synthesize a set of Planar Projection Data via Interpolation (interpolate between views taken at same projection angle, but different table positions), then Use Filtered Back Projection on Synthesized Planar Data Because a VOLUME of data has been acquired, IMAGE LOCATION IS ARBITRARY

Path of Continuously Rotating X-ray Tube (and Projection Data) Selected Image Plane (Arbitrary) Direction of Continuous Patient Transport 0 z, mm t, sec

Path of Continuously Rotating X-ray Tube (and Projection Data) Selected Image Plane (Arbitrary) Direction of Continuous Patient Transport 0 z, mm t, sec

360 degree algorithm Arbitrarily selected planar section at position z d z 1 z z 1 + d Planar data for arbitrary positions are calculated from spiral data by interpolation

180 Degree Algorithm Arbitrarily selected planar section at position z d measured spiral calculated spiral z1 Planar data for arbitrary positions are calculated from spiral data by interpolation z z1+d/2

180 Degree Algorithm Arbitrarily selected planar section at position z d measured spiral calculated spiral z1 Planar data for arbitrary positions are calculated from spiral data by interpolation z z1+d/2

Image Formation Independent of IMAGE ACQUISITION PARAMETERS (Because a VOLUME of Data is Acquired and Interpolation is used) Images can be formed ANYWHERE --> Slice Location is Arbitrary Overlapping Images can be created FROM A SINGLE VOLUMETRIC SCAN (e.g. 10 mm thick, 5 mm apart). Effective Slice Thickness Is Determined by Acquisition Parameters (Collimation, Pitch) and Interpolation

Contiguous Reconstruction - No Overlap Width of Image (From Collimation) Center of Image Image Number 1 2 3 0 z, mm t, sec

Overlapping Reconstruction - 50% Overlap Image Number 1 2 3 0 z, mm t, sec

Contiguous reconstruction - object aligned with slices Image Number 1 2 3 4

Contiguous reconstruction - object aligned in between slices Image Number 1 2 3 4

Overlapping reconstruction - object aligned in between slices 2 4 6 8 Image Number 1 3 5 7 Note: Object is Volume Averaged in Slices 3 and 5, but contained completely within slice 4

Spiral CT - Differences From Axial Image Quality (Assuming 180 interp. algorithm): Effective Slice Thickness Increases with Pitch (~10% increase for pitch 1; ~ 30% for pitch 2; ~ 70% for pitch 3) Hence volume averaging increases with pitch Noise is > Conventional Axial under identical acquisition conditions, but does not change w/ pitch

Spiral CT - Differences From Axial Radiation Dose: For Pitch of 1 ~ Same as Comparable Contiguous Conventional Scans For Pitch 1.5 - Approximately 2/3 that of Contiguous Scans For Pitch 2 - Approximately 1/2 of Contiguous Scans Radiation Dose Proportional to 1/pitch

What s Next? Faster, Thinner Spirals with LOTS of Images Faster Tube Rotation Times Greater Heat Capacity Tubes More Detector Planes Faster Image Reconstruction

Faster Tube Rotation Times Most Major CT Mfrs now offer subsecond scanners between.5 -.8 s for a full rotation However, to get same photon statistics with shorter exposure time means tube current must increase need higher kw generators and higher Heat Capacity Tubes to sustain tube currents.

Tubes with Greater Heat Capacity Current Tubes are Typically 2-3 MHU (Axial Scanners used < 1 MHU) Top of Line NOW are > 6 MHU This allows longer spirals ( less tube cooling delays) Also allows increase in tube current to offset reduced scan times

More Detector Planes Elscint CT-Twin in 1994 had two adjacent detectors This allowed simultaneous acquisition of 2 images - 2 X coverage for same scan time Now GE, Siemens, Picker and Toshiba have, or have announced, Multidetector systems

Collect Multiple Slices Simultaneously to: Cover More Patient in the Same Time Cover Same Amount of Patient, but w/ Thinner Slices Scan a Volume at Arterial Phase, Venous Phase, Parenchymal Phase after Contrast Injection

GE- 4 Row Detector 16 rows of detectors, use 4 at a time Allows collection of 4x1.25 mm slices (or 4x2.5, or 4x5) SIMULTANEOUSLY Will go to 16 rows simultaneous when data transfer is quick enough

LightSpeed Matrix Detector HiLight Detector 852 channels in 49 o degree arc LightSpeed Matrix Detector 14,592 elements in 55 o degree arc 16 Rows x 912 Channels Each channel is 1 mm wide by 20 mm tall Each ELEMENT is 1 mm wide by 1.25 mm tall

How Is It Used? Off Active Off 4 x 1.25 mm Mode 5 mm per rotation 4 x 2.5 mm Mode 10 mm per rotation 3 Rows = One DAS Channel Off Active Off 4 x 3.75 mm Mode 15 mm per rotation 4 x 5 mm Mode 20 mm per rotation

Helical Imaging Modes Detector Configurations 4 x 1.25 mm 4 x 2.5 mm 4 x 3.75 mm 4 x 5 mm Image Thicknesses 1.25, 2.5 mm 2.5, 3.75, 5.0 mm 3.75*, 5.0, 7.5 mm 5.0, 7.5, 10.0 mm Table Travel Per Rotation HQ 3.75 mm 7.5 mm 11.25 mm 15 mm HS 7.5 mm 15 mm 22.5 mm 30 mm Note: * 3.75 mm thickness not available at 22.5 mm/rot

Acquisition & Reconstruction Matrix Detector 4 x 2.5 mm Mode Multiple Row Recon Algorithms 4 x 2.5 mm Images 2 x 5 mm Images Multiple Row Data Acquisition 1 x 10 mm Image More Complex Than Single-Slice

4:1 Pitch Significant Data Overlap w/o IQ gain 3:1 Pitch 0 o 180 o 0 o 180 o 360 o 360 o Limited Overlap Optimum IQ Choice Of Of Pitch Critical to to IQ IQ

Faster Reconstructions Currently about 2-3 seconds per image In some commercial packages (options) ~ 1 second Faster Computers and Dedicated Processors will reduce this < 1 sec/image

What will the Current/Near Future System Look Like? Fast Tube/Gantry Rotation (.5 second) Tube Heat Capacity > 6 MHU MultiDetector System (4 now with pathways to 16 and up to 34 depending on manufacturer) Faster Reconstruction Times (subsecond) Hundreds (Thousands?) of Images Possible How to review all these?

What Will You Be Able to Do? Single Breath Thoracic Scan - Cover 35 cm w/ 1.25 mm slices <10 s

What Will You Be Able to Do? Two Phase Liver with Contrast - Cover 12 cm w/1.25 mm slices 2X (up and back) in <(8s + scan delay of ~5s)

What Will You Be Able to Do? ER Trauma Case Cover 180 cm (head to toe) in a single 48 s scan with 5mm (soon with 1.25mm)

Basic CT Physics Overview References Newton TH and Potts DG, eds, Radiology of the Skull and Brain: Technical Aspects of Computed Tomography, The C.V. Mosby Co., St. Louis, 1981. Principles of Spiral CT Kalender WA; Seissler W; Klotz E; Vock P. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology, 1990 Jul, 176(1):181-3. Crawford CR, King KF. Computed Tomography Scanning with simultaneous patient translation. Medical Physics 1990, 17:967-982. Remy-Jardin M, Remy J, eds. Spiral CT of the Chest, Springer, Berlin, 1996. Chapter 1- Principles of Spiral CT by M.W. Vannier and G. Wang.

References Physics of Spiral CT Kalender WA; Polacin A. Physical performance characteristics of spiral CT scanning. Medical Physics, 1991 Sep-Oct, 18(5):910-5. Polacin A; Kalender WA; Marchal G. Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology, 1992 Oct, 185(1):29-35. Polacin A; Kalender WA; Brink J; Vannier MA. Measurement of slice sensitivity profiles in spiral CT. Medical Physics, 1994 Jan, 21(1):133-40.

References Physics of Spiral CT (cont d) Wang G; Vannier MW. Stair-step artifacts in threedimensional helical CT: an experimental study. Radiology, 1994 Apr, 191(1):79-83. Wang G; Vannier MW. Longitudinal resolution in volumetric X-ray computerized tomography--analytical comparison between conventional and helical computerized tomography. Medical Physics, 1994 Mar, 21(3):429-33. Kasales CJ; Hopper KD; Ariola DN; TenHave TR; Meilstrup JW; Mahraj RP; Van Hook D; Westacott S; Sefczek RJ; Barr JD. Reconstructed helical CT scans: improvement in z-axis resolution compared with overlapped and nonoverlapped conventional CT scans. AJR. American Journal of Roentgenology, 1995 May, 164(5):1281-4.