Table of Contents. Scan acquisition and user interface basics. Dose modulation and reduction tools. Multi-Slice Detector Geometry
|
|
|
- Brittany Green
- 10 years ago
- Views:
Transcription
1 Table of Contents Scan acquisition and user interface basics Dose modulation and reduction tools Multi-Slice Detector Geometry Image Reconstruction and Display Contrast Media Tools Multi-planar formats and 3-D Processing Service and Application Tools Workflow
2 CT scan parameters: Translation of terms for different manufacturers Introduction For the CT technologist who operates multiple scanner models, perhaps from multiple manufacturers, the variability in names for important scan acquisition and reconstruction parameters can lead to confusion, reduced comfort and an increased potential for error. The intent of this CT terminology lexicon is to allow users to translate important CT acquisition and reconstruction terms between different manufacturers' systems. This represents a first step in the terminology standardization effort undertaken by this working group. Phase 2 of our work will: 1. Identify relevant terms from established standard lexicons (e.g. RadLex and DICOM) and other relevant literature and publish an expanded lexicon including these terms. 2. Form consensus recommendations on preferred terms. This website will be updated as the terminology standardization work progresses. The generic descriptions or terms in the first column are intended to orient the user to the relevant concepts; they are not consensus "preferred terms." The generic descriptions are not based on any single existing or pending terminology standard; however the references cited below were consulted in developing the generic descriptions. Future efforts of this Working Group include making recommendations for standardized terminology. A number of individuals and groups have advocated for terminology standardization in CT, including at a March 30-31, 2010 FDA public meeting entitled "Device Improvements to Reduce Unnecessary Radiation Exposure from Medical Imaging" (transcripts available at: see p ). Participants proposed a cooperative effort among professional organizations (AAPM, ASRT, ACR, etc.), industry, FDA, and standards organizations to accomplish this task, as is now being undertaken by this Working Group.
3 References IEC ed3.0 ( ) Medical electrical equipment Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography. Kalra, M. K. and S. Saini Standardized nomenclature and description of CT scanning techniques. Radiology 241, National Electrical Manufacturer's Organization Digital Imaging and Communications in Medicine (DICOM). (Downloadable from: ftp://medical.nema.org/medical/dicom/2009/) RadLex Tree Browser ( Weber, N. M., C. L. Siegle, J. E. Miller, M. K. Hudson, J. M. Kofler, M. R. Bruesewitz, and C. H. McCollough. How to be a "multi-lingual" CT technologist: understanding scan parameters from different manufacturer's equipment RSNA Annual Meeting poster ( Weigold, W.G., et al Standardized Medical Terminology for Cardiac Computed Tomography: A Report of the Society of Cardiovascular Computed Tomography. Journal of Cardiovascular Computed Tomography (downloadable from:
4 AAPM Working Group on Standardization of CT Nomenclature and Protocols Members: Additional contributors: AAPM: ACR: Cynthia McCollough (Chair) Dianna Cody (Co-chair) Dustin Gress James Kofler Michael McNitt-Gray Robert Pizzutiello Mark Armstrong Theresa Branham Priscilla Butler AAPM: GE: Hitachi: MITA: RadLex: Lifeng Yu Karen Procknow Catherine Neumann Stephen Vastagh Daniel Rubin ASRT: Virginia Lester DICOM: David Clunie Kevin O'Donnell FDA: Thalia Mills MITA: Gail Rodriguez GE: John Jaeckle Hitachi: Mark Silverman Philips: Mark Olszewski Siemens: Christianne Leidecker Toshiba: Richard Mather
5 1. Scan acquisition and user interface basics The portion of the user interface where scans are prescribed Exam Rx Scan Procedure Examination exam Plan Scan Protocol Other portions of the user interface, such as were reconstructed images are viewed Desktop Active viewer Various task cards, such as Viewing Active display Image Viewer CT localizer radiograph (i.e. the scanned projection radiograph, often acquired by the CT system to allow the user to prescribe the start and end locations of the scan range) Scout Surview Topogram Scanogram Scanogram Axial scan mode: Data acquisition while the patient table remains stationary; the table position may be incremented between x-ray exposures to collect data over a longer z axis range. Axial Axial Sequence Scan & View, Scan & Scan, Volume, Wide Volume (Aquilion One) Normal Helical or Spiral scan mode: Data acquisition while the patient table is continuously moving along the z axis. Helical Helical Spiral Helical Volume Dynamic scan mode - single detector width: Data acquisition at multiple time points over the same anatomic location(s) while the patient table remains stationary; x-ray exposure can be continuous or intermittent Cine or zero interval Axial CCT (Continuous CT) Dynamic (continuous) or Serio (intermittent); scan mode name: DynMulti or DynSerio. Dynamic (Continuous or Intermittent) Dynamic Dynamic scan mode - multiple detector widths: Data acquisition at multiple time points over the same anatomic location(s) while the patient table cycles back and forth between designated start and end locations in order image a region wider than the detector Shuttle Jog Adaptive 4D Spiral; scan mode name: DynMulti4D or DynSerio4D (ECG triggered) N/A N/A Interventional CT - Intermittent x-ray exposures SmartStep Single CCT Model dependent: Biopsy or Intervention (i-sequence/i-spiral) Interventional CT - Continuous x-ray exposures SmartView Continuous CCT Model dependent: CARE Vision or Intervention (i- Fluoro) CT Fluoro (CTF) CT Fluoro (CTF) guideshot Not available Table increment (mm) per 360 degree rotation of the x-ray tube (axial scan mode) Interval Increment (mm) Feed (mm) Couch movement (mm) Table Feed (mm) Table feed per 360 degree rotation of the x-ray tube (helical scan mode) Speed (mm/rot) Table speed (mm/rot) Table Feed (mm/rot)* Couch speed (mm/rot) Table Speed (mm/rot) Acquisition field of view: Diameter of the circular region within the scan plane over which projection data are collected. Nominally equal to the diameter of the primary beam at isocenter in the axial plane. Scan Field of View (SFOV, cm) Not determined by tech; built into protocol Not determined by tech; built into protocol CFOV (Calibrated Field of View) Scan Field of View (SFOV, mm)
6 Scan acquisition and user interface basics, continued Tube current: Number of electrons accelerated across an x-ray tube per unit time, expressed in units of milliampere (ma) ma ma* ma* ma ma Tube current-time product: The product of tube current and exposure time per rotation, expressed in units of milliampere seconds (mas). In axial scan mode, this is equal to tube current (scan angle 360) rotation time. In helical scan mode, this is equal to tube current rotation time. Not used on this system mas mas mas Not used on this system Effective tube current-time product: In helical scan mode, this is the product of tube current and rotation time (expressed in units of milliampere seconds (mas) pitch) Not used on this system mas per slice (= mas/pitch) Effective mas (= mas/pitch) Effective mas (= mas/pitch) Not used on this system Tube potential: The electric potential applied across an x-ray tube to accelerate electrons towards a target material, expressed in units of kilovolts (kv) Pitch: Unitless parameter used to describe the table travel during helical CT; equal to table travel (mm) per gantry rotation total nominal beam width (mm) kv kvp kv kv kvp Pitch Pitch Pitch CT Pitch Factor Pitch Automated patient instructions AutoVoice Auto voice API (Automated Patient Instructions) Breath Control Auto Voice * Not able to be directly modified on the user interface. Value is calculated/determined by other settings.
7 2. Dose modulation and reduction tools Automatic exposure control (AEC): A scanner feature that automatically adapts the x-ray tube current to the overall patient size to achieve a specified level of image quality Available in AutomA and SmartmA Available in DoseRight Automatic Current Selection (ACS) Available in CARE Dose4D Available in SURE Exposure Available in IntelliEC Angular tube current modulation SmartScan (CT/i only) D-DOM (Dose Modulation) CARE Dose not available as a separate item Adaptive ma Longitudinal tube current modulation AutomA Z-DOM not available as a separate item SURE Exposure n/a Angular and longitudinal tube current modulation SmartmA (x, y, z) Work in progress CARE Dose4D SURE Exposure 3D (X, Y and Z Modulation) IntelliEC ECG-based tube current modulation ECG Modulated ma DoseRight Cardiac All features available in HeartView package (except (3), only available for SOMATOM Definition Flash) (1) Retrospective gated spiral mode: use Pulsing settings in Trigger card ECG Modulation ECG Dose Modulation (2) Prospective triggered sequence: use Adaptive Cardio Seq. and Pulsing settings in Trigger card. (3) Prospectively triggered spiral ( Flash mode) Image quality reference parameter for AEC Noise Index Reference image Quality reference mas Standard Deviation or standard, low-dose, or highquality Standard Deviation (% ) or standard, low-dose, or high-quality
8 3. Multi-Slice Detector Geometry Generic description GE PHILIPS SIEMENS TOSHIBA HITACHI Multi-slice detector array design Fixed Model dependent: Fixed or Asymmetric Model dependent: Adaptive or Fixed Fixed (32 row and above); Adaptive (16 row and below) Asymmetric-16 slice; Fixed-64 slice Detector configuration Detector Configuration Collimation N x T (mm) Detector Configuration or Aqu (Acquisition) on Exam Card Detector Configuration Detector Configuration
9 4. Image Reconstruction and Display Window width: Range of CT numbers (maximum - minimum) that are distributed over the viewable grey scale of the display device or film Window center: The CT number in the center of the viewable grey scale Window Width Window Width Window width Window width Window Width Window Level Window Center Window center Window level Window Level Reconstruction field of view: Width of the square region mapped to the reconstructed image matrix Display Field of View (DFOV) (cm) DFOV (mm) FoV (mm) DFOV (mm) DFOV (mm) Prescribing the reconstruction parameters prior to scan acquisition Prospective recon Recon and Additional Recons Recon Job Prospective recon Multi Recon Prescribing the reconstruction parameters after scan acquisition Retrospective recon Offline Recon or Re- Recon Recon Job Retrospective or Raw data recon Post Reconstruction Reconstruction property that determines sharpness or smoothness of image in the axial plane Algorithm Reconstruction Filter Kernel Filter convolution (FC) Image Filter Helical interpolation options to achieve a wider or narrower section sensitivity profile Full (narrower) or Plus (wider) mode Slice width independent of pitch Slice width independent of pitch Slice width independent of pitch Slice width independent of pitch Nominal width of reconstructed image along the z axis Thickness (mm) Thickness (mm) Slice (mm) Image thickness Slice Thickness Distance between two consecutive reconstructed images Interval Increment Position increment Reconstruction interval Interval Fast but lower-quality reconstructed images for rapid review of entire exam QC Image Image Check Evolving reconstructions RT (Real-time reconstruction) SUREScan Real Time Reconstruction Off-center reconstruction coordinates are called RL Center; AP Center Center x, center y Center x, Center y Center Position; (Vari Area) Center x, y Flip or rotate the image orientation is called Flip/rotate Flip/rotate Mirroring (Flip in Viewing card) Rotate Rotate/Mirror Flip/Rotate Image modifications to alter sharpness or smoothness (done in image space without reconstructing images) Image Filters Image enhancement filter Evaluation > Image Manipulation (Viewing card) Filter, QDS Filter
10 5. Contrast Media Tools Generic description GE PHILIPS SIEMENS TOSHIBA HITACHI Bolus tracking: Scanner feature to automatically initiate a prescribed axial, helical or dynamic scan when a threshold level of contrast enhancement is reached at a specified region of interest Smart Prep Bolus Tracking CARE Bolus (includes Test Bolus and Bolus Tracking) SUREStart Predict Scan Test Bolus: Scan mode used to measure the contrast transit time using a small injection of contrast media Take axial scans at zero table feed and process with MIROI Time Lapse Test Bolus Dynamic study Not available Time-attenuation curve (TAC): Graph of the contrast enhancement versus time Smart Prep graph or MIROI graph Time Lapse graph Enhancement Curve Time Density Curve Monitoring Graph Threshold: CT number (HU) where bolus tracking tool will trigger the system to begin the scan Transition ROI Threshold Threshold Level Threshold ROI (HU) Threshold Scanner feature used to quantitatively evaluate the TAC MIROI (multiple image region of interest) Tracker ROI Tools DynEva (dynamic evaluation) Real Time Monitoring No special name Monitoring delay: Time from injection to the start of monitoring scans (Time 1 in figure below) Monitoring Delay Post Injection Delay Delay (on monitoring scan) Delay (on SUREStart) Scan Delay Monitoring interval: Time between consecutive monitoring scans to (Time 2 in figure below) Monitor ISD (InterScan Delay) Cycle time Cycle time Real time monitoring or pulsed monitoring (seconds) Monitoring Time Scan delay: Time from when threshold is reached and prescribed axial, helical or dynamic scan begins (Time 3 in figure below) Diagnostic delay Post Threshold Delay Delay (on scan) Delay (on helical) Scan Delay Copyright August 11, 2011 by AAPM. All rights reserved.
11 6. Multi-planar formats and 3-D Processing Reformatted image at an oblique plane (not an axial, coronal, or sagittal) Saving images at various viewing angles about a volume or surface rendered object Oblique reformat Oblique Oblique Oblique Oblique MPR Batch Loop Cine Radial Ranges Key Frame Movie Multi-Slice /Angle Saving images at various planes through a volume Batch Reformat Batch MPR Parallel Ranges Batch MPR Multi planar reformat Surface-rendered object 3D SSD 3D (Shaded Surface Display 3D) Shaded Surface Display (SSD) ShadedVol (Shaded volume rendering (SVR)) Shaded Surface Display (SSD) Volume-rendered object Volume Rendered image (VR) Volume Rendering Volume Rendering Technique (VRT) Shaded Vol Volume Rendering 7. Service and Application Tools X-ray tube warm up Tube Warm-up (tube warm up) Tube conditioning Check-up (calibrate and check values); Warm up Warm up Calibrate (part of Check-up, can be performed separately) Daily calibrations Fast Cals (done in daily prep) Not necessary to do daily calibrations Quality Daily Selectable air calibrations can be scheduled after warm-up Air cals built into Warm up Application information Learning Solutions or User Manual On-line Help On-line Help; CT Life (task card) E-Learning Center Sentinel (Remote Service) Application support assistance Insite or Ilinq Customer Care Solutions Center Uptime In Touch Center CT Applications Helpline
12 8. Workflow Scheduled (but not yet scanned) patient list is called Patient Schedule Scheduled (HIS-RIS) and Catalog- (manual list) Patient Browser Scheduler Modality Worklist Manager MWM-modality worklist management Already scanned patient list is called List/Select Archive Manager Patient Browser Local Database Directory Patient List User comments or text added to an image is called User annotation Label (series) and Annotate (image) Comment Annotation Comment Filming tools are called Auto/manual film composer Filming Film Sheet on Filming task card Filming Filming Data page summarizing scan parameters, CTDIvol and DLP Exam Text Page or Series Text Page Image Parameters Patient Protocol (series number 501) Summary and Exposure Record Text Page Sorting patient list Sort Click on sort field (name, date, etc.) In Patient Browser: select Sort or Filter functions in menu bar Click on sort field (name, date, etc.) Click on sort field (name, date, etc.)
The disclaimer on page 1 is an integral part of this document. Copyright February 23, 2016 by AAPM. All rights reserved.
DISCLAIMER: TO THE EXTENT ALLOWED BY LOCAL LAW, THIS INFORMATION IS PROVIDED TO YOU BY THE AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE, A NON-PROFIT ORGANIZATION ORGANIZED TO PROMOTE THE APPLICATION
CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH
CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology
How To Improve Your Ct Image Quality
Translating Protocols Between Scanner Manufacturer and Model Cynthia H. McCollough, PhD, FACR, FAAPM Professor of Radiologic Physics Director, CT Clinical Innovation Center Department of Radiology Mayo
Moving Forward What does this mean for the Medical Physicist and the Imaging Community?
Moving Forward What does this mean for the Medical Physicist and the Imaging Community? John M. Boone, Ph.D., FAAPM, FACR Professor and Vice Chairman of Radiology University of California Davis Medical
The disclaimer on page 1 is an integral part of this document. Copyright March 1, 2016 by AAPM. All rights reserved.
DISCLAIMER: TO THE EXTENT ALLOWED BY LOCAL LAW, THIS INFORMATION IS PROVIDED TO YOU BY THE AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE, A NON-PROFIT ORGANIZATION ORGANIZED TO PROMOTE THE APPLICATION
CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions
CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions Frank N. Ranallo, Ph.D. Associate Professor of Medical Physics & Radiology University of Wisconsin School of
Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999
Spiral CT: Single and Multiple Detector Systems AAPM Refresher Course Nashville, TN July 28,1999 Mike McNitt-Gray, PhD, DABR Assistant Professor UCLA Radiological Sciences [email protected] X-Ray
Copyright March 1, 2016 by AAPM. All rights reserved.
DISCLAIMER: TO THE EXTENT ALLOWED BY LOCAL LAW, THIS INFORMATION IS PROVIDED TO YOU BY THE AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE, A NON-PROFIT ORGANIZATION ORGANIZED TO PROMOTE THE APPLICATION
Purchasing a cardiac CT scanner: What the radiologist needs to know
Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London [email protected] CT scanner development Slice wars 1998 Increased z-coverage
Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL
Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,
The disclaimer on page 1 is an integral part of this document. 1. Copyright December 14, 2015 by AAPM. All rights reserved.
DISCLAIMER: TO THE EXTENT ALLOWED BY LOCAL LAW, THIS INFORMATION IS PROVIDED TO YOU BY THE AMERICAN ASSOCIATION OF PHYSICISTS IN MEDICINE, A NON-PROFIT ORGANIZATION ORGANIZED TO PROMOTE THE APPLICATION
MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington
MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical
A d v a n c e d 1 2 8
Advanced 128 SCENARIA Advanced 128 Hitachi Innovation at Work for You. Continuing its commitment to the SCENARIA scalable CT platform, Hitachi introduces cutting-edge 128-slice technology with the SCENARIA
Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives
Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives Gilbert W. Beebe Symposium The National Academies Katharine Grant, PhD Staff Scientist 8 December 2011 For internal
Development of SCENARIA New Version Software MEDIX VOL. 62 P.32 P.35
Development of SCENAIA New Version Software Takayuki Kadomura Toshio Sakamoto Kana Tanaka Takatsugu Ito Yuuko Nishimura Naomi Maekawa MEDIX VOL. 62 P.32 P.35 Development of SCENAIA New Version Software
Assessing Radiation Dose: How to Do It Right
Assessing Radiation Dose: How to Do It Right Michael McNitt-Gray, PhD, DABR, FAAPM Professor, Department of Radiology Director, UCLA Biomedical Physics Graduate Program David Geffen School of Medicine
Cynthia H. McCollough b) and Michael R. Bruesewitz Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905
The phantom portion of the American College of Radiology ACR Computed Tomography CT accreditation program: Practical tips, artifact examples, and pitfalls to avoid a Cynthia H. McCollough b) and Michael
GE Healthcare. DoseWatch. Gathering Radiation Dose Data
GE Healthcare DoseWatch Gathering Radiation Dose Data Gathering Radiation Dose Data After your organization crosses the bridge of Why? for patient radiation dose management either due to regulation, risk
American College of Radiology CT Accreditation Program. Testing Instructions
American College of Radiology CT Accreditation Program Testing Instructions (Revised July 24, 2015) This guide provides all of the instructions necessary for clinical tests, phantom tests and general submission
Diagnostic Exposure Tracking in the Medical Record
Diagnostic Exposure Tracking in the Medical Record J.A. Seibert, Ph.D. Department of Radiology Sacramento, California USA Vancouver. British Columbia Relevant disclosures None Learning objectives Understand
IntelliSpace PACS 4.4. Image Enabled EMR Workflow and Enterprise Overview. Learning Objectives
IntelliSpace PACS 4.4 Image Enabled EMR Workflow and Enterprise Overview Learning Objectives Use the Cerner EMR to view images and reports via IntelliSpace PACS: Image Launch Workflow (SUBI Image Viewer)
The power of Multislice CT Philips MX 6000 Dual
The power of Multislice CT Philips MX 6000 Dual Philips MX systems bring new levels of quality, simplicity and reliability to CT imaging. Designed by the same people that brought the world Philips CT,
Chest CT protocols. Mannudeep K. Kalra, MD, DNB. Dianna D. Cody, PhD. Massachusetts General Hospital Harvard Medical School
Chest CT protocols Mannudeep K. Kalra, MD, DNB Dianna D. Cody, PhD Massachusetts General Hospital Harvard Medical School M.D. Anderson Cancer Center Specific principles Routine chest CT Lung nodule follow
CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements
CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index Keith J. Strauss, MSc, FAAPM, FACR Clinical Imaging Physicist Cincinnati Children s Hospital University of Cincinnati College of
SITE IMAGING MANUAL ACRIN 6698
SITE IMAGING MANUAL ACRIN 6698 Diffusion Weighted MR Imaging Biomarkers for Assessment of Breast Cancer Response to Neoadjuvant Treatment: A sub-study of the I-SPY 2 TRIAL Version: 1.0 Date: May 28, 2012
3/12/2014. Disclosures. Understanding IAC CT Accreditation. Outline. Learning Objectives. Who is the IAC?
Disclosures Understanding IAC CT Accreditation Serve as one of two AAPM representatives to IAC CT Board of Directors, Serve as IAC representative to AAPM for focus group on accreditations Provide 3-hour
Mx8000 IDT 16 provides dose control methodologies like DoseRight ACS (Automatic Current Selection) and DoseRight DOM (dynamic dose modulation).
Philips Mx8000 IDT 16 CT Scanner Philips Medical systems Mx8000 IDT 16 delivers 16 simultaneous slices at sub-millimeter collimator, high resolution and isotropic imaging. New large area detectors allow
GE Healthcare. Revolution EVO. More than just high tech. Higher purpose.
GE Healthcare Revolution EVO More than just high tech. Higher purpose. Revolution EVO. Designed with purpose. Today s healthcare environment is about creating new solutions to pressing needs. It s about
Protocol Management and Review Strategies The MD Anderson Experience
Protocol Management and Review Strategies The MD Anderson Experience Dianna Cody, Ph.D. Professor Dept. of Imaging Physics Univ. of Texas M.D. Anderson Cancer Center Objectives Setting up a policy for
Brilliance CT 64-channel confi guration
Brilliance CT 64-channel confi guration with Essence technology The Brilliance CT 64-channel confi guration is designed to help you conduct the most advanced multislice CT studies possible. These systems
REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22
REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 New Jersey Department of Environmental Protection Bureau of Radiological Health PO Box 415 Trenton NJ
Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose
Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose ipatient is an advanced platform that delivers focused innovations to facilitate patient-centered
PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X
DIGITAL X-RAY SYSTEM with ceiling mounted tube support Universal Digital Radiographic System Conventional system, full DR components Best-in-class image quality Flexible connectivity to PACS systems General
Imaging of Thoracic Endovascular Stent-Grafts
Imaging of Thoracic Endovascular Stent-Grafts Tariq Hameed, M.D. Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, Indiana Disclosures: No relevant financial
AAPM Medical Physics Practice Guideline 1.a: CT Protocol Management and Review Practice Guideline
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 14, NUMBER 5, 2013 AAPM Medical Physics Practice Guideline 1.a: CT Protocol Management and Review Practice Guideline The American Association of Physicists
An Overview of Digital Imaging Systems for Radiography and Fluoroscopy
An Overview of Digital Imaging Systems for Radiography and Fluoroscopy Michael Yester, Ph.D. University of Alabama at Birmingham Outline Introduction Imaging Considerations Receptor Properties General
Siemens Computed Tomography
Siemens Computed Tomography Innovation Leader. The Cosmopolitan Information Topic Waltraud Winter Siemens Copyright Siemens AG 2011. All rights reserved. Page 1 October 2012 Waltraud Winter An Innovation
Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)
Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Excelart Vantage Magnet Configuration: Ultra-short-bore Strength (or W x H): 1.5 T Homogeneity, ppm V-RMS: Dimensions of maximum
Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad.
1 12/9/2008 Page 1 Master s Program in Medical Physics Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III Chair in Faculty of Medicine Mannheim University of Heidelberg Theodor-Kutzer-Ufer
Performance testing for Precision 500D Classical R/F System
Performance testing for Precision 500D Classical R/F System John M. Boudry, Ph.D. Image Quality Systems Engineer GE Healthcare Technologies Outline System background Image Quality Signature Test (IQST)
Techniques and Applications of Automatic Tube Current Modulation for CT 1
Review Radiology Mannudeep K. Kalra, MD, DNB Michael M. Maher, MD, FFR (RCSI), FRCR Thomas L. Toth, DSc Bernhard Schmidt, PhD Bryan L. Westerman, PhD Hugh T. Morgan, PhD Sanjay Saini, MD Index terms: Computed
Chest 1: Pulmonary Nodule Follow-up: Low-Dose Helical CT (Unenhanced) (Non-metastatic) Gantry Rotation Time. mas (Reg-Lg) 40-80
Revisions Effective January 2012 Chest 1: Pulmonary Nodule Follow-up: Low-Dose Helical CT (Unenhanced) (Non-metastatic) Technologist Instructions Patient must cough several times prior to scan to clear
Twelve. Figure 12.1: 3D Curved MPR Viewer Window
Twelve The 3D Curved MPR Viewer This Chapter describes how to visualize and reformat a 3D dataset in a Curved MPR plane: Curved Planar Reformation (CPR). The 3D Curved MPR Viewer is a window opened from
DICOM Correction Item
Correction Number DICOM Correction Item CP-626 Log Summary: Type of Modification Clarification Rationale for Correction Name of Standard PS 3.3 2004 + Sup 83 The description of pixel spacing related attributes
multimodality image processing workstation Visualizing your SPECT-CT-PET-MRI images
multimodality image processing workstation Visualizing your SPECT-CT-PET-MRI images InterView FUSION InterView FUSION is a new visualization and evaluation software developed by Mediso built on state of
Patient Dose Tracking for Imaging Studies. David E. Hintenlang, Ph.D., DABR University of Florida
Patient Dose Tracking for Imaging Studies David E. Hintenlang, Ph.D., DABR University of Florida Conflict of Interest Statement No affiliation or financial interests in any of the commercial products or
Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme
Medical Exposure Directive 97/43 Euratom Quality Assurance Ministry of Health, Radiation Protection Department, Luxembourg Alexandra Schreiner Medical Physicist Quality Assurance (QA): All those planned
QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET
Centers for Quantitative Imaging Excellence (CQIE) LEARNING MODULE QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET American College of Radiology Clinical Research Center v.1 Centers for Quantitative
Cone Beam Reconstruction Jiang Hsieh, Ph.D.
Cone Beam Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced acquisition
Understanding Digital Modalities: System Integration and Use
Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI [email protected] Dicom Digital Imaging and Communications in Medicine Part 3: Information
3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage
3D SCANNERTM 3D Scanning Comes Full Circle Relative 3D Dosimetry offering the easiest setup, most objectivity, and best consistency available The 3D SCANNER Advantage Advanced Design Ring and diameter
ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.
ParaVision 6 The Next Generation of MR Acquisition and Processing for Preclinical and Material Research Innovation with Integrity Preclinical MRI A new standard in Preclinical Imaging ParaVision sets a
Gestión global de la dosis en TC. Sistema de registro y gestión
Gestión global de la dosis en TC. Sistema de registro y gestión IV Jornada de Protección Radiológica Hospitalaria SARH FEA Radiofísica Hospital Virgen de las Nieves. Granada [email protected] 22
International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters
www.led-professional.com ISSN 1993-890X Trends & Technologies for Future Lighting Solutions ReviewJan/Feb 2015 Issue LpR 47 International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in
Image Acquisition and Diagnostics
en examion aqs software examion aqs software Image Acquisition and Diagnostics Professional Image Acquisition and Diagnostic Workstation examion aqs software is the universal image acquisition software
A PACS-Aware DICOM Image Object
Designing and Implementing A PACS-Aware DICOM Image Object For Digital X-ray, Mammography and Intraoral Applications David A. Clunie Quintiles Intelligent Imaging Clear Vision for the Healthcare Industry
Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners
Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners Background The lateral response artifact (LRA) in radiochromic film images from flatbed scanners was first pointed
resource Osirix as a Introduction
as a osirix-viewer.com/snapshots.html by Tonya Limberg 2008, MS, Biomedical Visualization, University of Illinois at Chicago Introduction is a freeware program available to the public on the Apple Inc.
Acknowledgement. Diagnostic X-Ray Shielding. Nomenclature for Radiation Design Criteria. Shielding Design Goal (Air Kerma):
Diagnostic X-Ray Shielding Multi-Slice CT Scanners Using NCRP 47 Methodology Melissa C. Martin, M.S., FAAPM, FACR Therapy Physics Inc., Bellflower, CA AAPM Annual Meeting, Orlando, FL Refresher Course
Manual for simulation of EB processing. Software ModeRTL
1 Manual for simulation of EB processing Software ModeRTL How to get results. Software ModeRTL. Software ModeRTL consists of five thematic modules and service blocks. (See Fig.1). Analytic module is intended
Workstation, Server Hosted
Workstation, Server Hosted With so many PACS out there, Why just make another? So, we didn't. Distribute, Burn, Print, Import, Archive The Internet DICOM Eye Web Web Viewer PACStoGo DICOM Distribution
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM
Data. microcat +SPECT
Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for
DENTAL Cone beam 3D X-RAY SYSTEM with
VERSATILE INTUITIVE efficient DENTAL Cone beam 3D X-RAY SYSTEM with dedicated panoramic imaging With thirty years of experience in designing and manufacturing state-of-the-art dental panoramic and tomographic
SWABIK Project. Software Tools for DICOM Media Exchange in Clinical Research: the. SWABIK Project
Software Tools for DICOM Media Exchange in Clinical Research: the SWABIK Project Software Tools for DICOM Media Exchange in Clinical Research: the SWABIK Project O. ElGazzar 1, M. Onken 1, M. Eichelberg
Imaging Viewing Imaging Viewing Mammography Mammography
INTUITIVE PC-BASED DICOM VIEWING AND ROUTING SOLUTIONS that provide unmatched functionality, flexibility and superior data management even in the most demanding production environments. Enterprise Grade
SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS
Note: This is a courtesy copy and is not the official version of this rule. The official, legally effective version of this rule is available through www.lexisnexic.com/bookstore (Phone: (800) 223-1940).
CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E.
1 Overview CT scanning By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU (Ver. 1.2 4/9/07) 2002-2007 by M. Jensen and J. E. Wilhjelm) As it can be imagined, planar X-ray imaging has
OPTIMIZING PATIENT EXPOSURE TO IONIZING RADIATION (OPEIR) MEASURES GROUP OVERVIEW 2015 PQRS OPTIONS FOR MEASURES GROUPS:
OPTIMIZING PATIENT EXPOSURE TO IONIZING RADIATION (OPEIR) MEASURES GROUP OVERVIEW 2015 PQRS OPTIONS F MEASURES GROUPS: 2015 PQRS MEASURES IN OPTIMIZING PATIENT EXPOSURE TO IONIZING RADIATION (OPEIR) MEASURES
Patient sample criteria for the OPEIR Measures Group are all patients regardless of age, that have a specific CT procedure performed:
OPTIMIZING PATIENT EXPOSURE TO IONIZING RADIATION (OPEIR) MEASURES GROUP OVERVIEW 2016 PQRS OPTIONS F MEASURES GROUPS: 2016 PQRS MEASURES IN OPTIMIZING PATIENT EXPOSURE TO IONIZING RADIATION (OPEIR) MEASURES
R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.
R/F Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening Department of Radiology, National Cancer Center Hospital East Kaoru Shimizu Ms. Kaoru Shimizu 1. Introduction
State-of-the-Art Technology in Cardiac CT
1 2 Next Step Evolution or Revolution? State-of-the-Art Technology in Cardiac CT Stefan Ulzheimer, PhD Global Director of Collaborations CT Siemens Medical Solutions Major Innovations in CT Head The 80
Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals
Rb 82 Cardiac PET Scanning Protocols and Dosimetry Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals Overview Rb 82 myocardial perfusion imaging protocols Acquisition Reconstruction
Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro.
www.neurologica.com Critical Care Clinic Operating Room Radiology ED Trauma OR Neuro/Spine Pediatric Plastics Thoracic General Interventional Radiology ENT ED Trauma Trauma Stroke Critical Care Neuro Pediatric
GE Healthcare. Great treasures in small places. BrightSpeed Elite
GE Healthcare Great treasures in small places BrightSpeed Elite The BrightSpeed Elite brings you multi-detector CT capabilities with maximum convenience in an ultra-compact design. Built with LightSpeed
Automated EMR Dose History Extraction and Monitoring
Automated EMR Dose History Extraction and Monitoring Aaron Sodickson MD, PhD Section Chief, Emergency Radiology Medical Director of CT, Brigham Radiology Network Brigham and Women s Hospital Harvard Medical
Voxar 3D TM. A suite of advanced visualization and analysis software tools
Voxar 3D TM A suite of advanced visualization and analysis software tools The power to deliver advanced visualization throughout the enterprise To effectively manage the rapid growth of large volumetric
QAV-PET: A Free Software for Quantitative Analysis and Visualization of PET Images
QAV-PET: A Free Software for Quantitative Analysis and Visualization of PET Images Brent Foster, Ulas Bagci, and Daniel J. Mollura 1 Getting Started 1.1 What is QAV-PET used for? Quantitative Analysis
IAEA HUMAN HEALTH SERIES
IAEA HUMAN HEALTH SERIES No. 19 Quality Assurance Programme for Computed Tomography: Diagnostic and Therapy Applications IAEA HUMAN HEALTH SERIES PUBLICATIONS The mandate of the IAEA human health programme
Prepublication Requirements
Issued Prepublication Requirements The Joint Commission has approved the following revisions for prepublication. While revised requirements are published in the semiannual updates to the print manuals
CT QC Under the ACR QC Manual. What? There s a Manual?? Learning Objectives 8/6/12! ! YES!!! Almost. ! Doesn t have a pretty cover yet
CT QC Under the ACR QC Manual Douglas Pfeiffer, MS, DABR Boulder Community Hospital What? There s a Manual??! YES!!! Almost! Doesn t have a pretty cover yet! Should be out by RSNA! Really seriously I mean
AN INNOVATIVE & CUTTING-EDGE DIGITAL RADIOGRAPHY SYSTEM
SAMSUNG SMART DIGITAL RADIOGRAPHY 2012 Samsung Electronics All rights reserved. Samsung Electronics reserves the right to modify the design, packaging, specifications and features shown herein, without
Multi Detector Row CT Systems and Image- Reconstruction Techniques 1
Special Review Radiology Thomas G. Flohr, PhD Stefan Schaller, PhD Karl Stierstorfer, PhD Herbert Bruder, PhD Bernd M. Ohnesorge, PhD U. Joseph Schoepf, MD Published online before print 10.1148/radiol.2353040037
Configuration and Use of the MR Knee Dot Engine
Configuration and Use of the MR Knee Dot Engine Kai Reiter (RT); Sebastian Auer (RT) Radiology Herne, Herne, Germany 1 42 MAGNETOM Flash 3/2011 www.siemens.com/magnetom-world We are a radiological joint
Fast mobile reading on the go November 2013. syngo.via WebViewer. Unrestricted Siemens AG 2013 All rights reserved.
Fast mobile reading on the go November 2013 syngo.via WebViewer Answers for life. syngo.via WebViewer The mobile extension of syngo.via syngo.via WebViewer 1, enables mobile reading of images with brilliant
The Challenge of CT Dose Records
The Challenge of CT Dose Records Kimberly Applegate, MD, MS, FACR Professor of Radiology and Pediatrics Emory University *financial disclosures: -Springer Textbook contracts -AIM advisory board for patient
X-ray Imaging Systems
Principles of Imaging Science I (RAD 119) X-ray Tube & Equipment X-ray Imaging Systems Medical X-ray Equipment Classified by purpose or energy/current levels kvp, ma Radiographic Non-dynamic procedures
A full-featured online DICOM archive built on the same SQL platform as our powerful enterprise grade PACS database. Enterprise Grade DICOM Engine
DICOM A full-featured online DICOM archive built on the same SQL platform as our powerful enterprise grade PACS database. SQL Database Enterprise Grade DICOM Engine Flexible Archiving Solutions Internet
The Exposure Index and Its Standardization
The Exposure Index and Its Standardization Ulrich Neitzel Philips Medical Systems Clinical Science Hamburg, Germany [email protected] Content The Exposure Index (EI) What is it? What is it good
PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors
Quality Control in PET PET/CT QC/QA Magnus Dahlbom, Ph.D. Division of Nuclear Medicine Ahmanson Biochemical Imaging Clinic David Geffen School of Medicine at UCLA Los Angeles Verify the operational integrity
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer
INTRODUCTION. A. Purpose
New York State Department of Health Bureau of Environmental Radiation Protection Guide for Radiation Safety/Quality Assurance Programs Computed Radiography INTRODUCTION A. Purpose This guide describes
0 EC2 92011 V-,) 133 Lj9a
0 EC2 92011 V-,) 133 Lj9a Section 5: 5 1 0(k) Summar 5 10(K) SUMMARY FOR SOMATOM DEFINITION Flash (with Stellar Detector) Submitted by: Siemens Medical Solutions USA, Inc. 51 Valley Stream Parkway Malvern,
COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS
COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS DRive is a digital imaging DR hardware & Software solution designed for General Radiography of anatomy. It is intended to replace film/screen
M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy
M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy Katja Langen, PhD Research supported by TomoTherapy Inc. Today s Lecture Introduction to helical
Avizo Inspect New software for industrial inspection and materials R&D
Avizo Inspect New software for industrial inspection and materials R&D Reduce your design cycle, inspection times, and meet higher-level quality standards at a lower cost. Avizo Inspect software streamlines
