CGC s Hybrid System Loop Control



Similar documents
Condensing Boiler Efficiency


Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Commissioning - Construction Documents (Page 1 of 6)

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

HVAC Processes. Lecture 7

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

How Ground/Water Source Heat Pumps Work

How To Use A Water Source Heat Pump

STERILIZERS, LABORATORY DRYING OVENS

Design guidelines for hybrid boiler systems.

Technical Support Bulletin Nr. 20 Special AC Functions

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Impact of Control System Technologies on Industrial Energy Savings

WHITE PAPER #: CLIMATEMASTER KNOWLEDGE SERIES: HEAT PUMP DESIGN FOR 100% OUTSIDE AIR SYSTEMS THE SMART SOLUTION FOR ENERGY EFFICIENCY

REMOTE CONTROL MANUAL

Commercial Boiler Systems and Controls

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

General Information. Do programmable thermostats really save energy?

Bring the fresh in. Dedicated Outside Air Systems

Failure code manual. content

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Aerona Air Source Heat Pumps

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning

HP switch LP switch Discharge thermo Comp. Surface thermo

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Y-200 Multi-Stage Sequencer

Heating, cooling and irrigation system for a house. Control with two controllers TS-55T + 2 depending on the seasons. option 1 Functional scheme

Single Zone LCD Thermostat Operating Instructions

Daikin Altherma hybrid heat pump. The natural combination

for Plans Examiners and Building Inspectors

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

Case Study -Sandy Grove Middle School First Net Positive Energy P3 School In North Carolina

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Building Re-Tuning Training Guide: AHU Heating and Cooling Control

For installation guide see reverse of book

Heating Water by Direct Steam Injection

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Basic Technology Series

CONTROL STRATEGIES FOR HVAC SYSTEMS

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Fundamentals of HVAC Control Systems

PANASONIC TROUBLE SHOOTING GUIDE

Heat Pump Water Heater IOM Manual

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE

Benefits of. Air Flow Management. Data Center

How To Improve Energy Efficiency Through Raising Inlet Temperatures

newsletter engineers energy-saving strategies for Water-Source Heat Pump Systems volume 36 2 providing insights for today s hvac system designer

Heating, air-conditioning, cooling

ENERGY RETROFIT PROGRAM

Water cooled chiller plant (cp/vs)

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

Lesson 36 Selection Of Air Conditioning Systems

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

How To Save Energy With High Pressure Control

Contents. Introduction

UNIFIED FACILITIES GUIDE SPECIFICATIONS

European test facilities for solar combisystems and heat stores

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

The Benefits Really Add Up

Congratulations! Your unique solar monitor ID is located on your monitoring unit as seen on this page.

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Commercial Refrigeration Temperature and Defrost Controls

Nordic Heat Pump Product Guide

UNDERSTANDING CENTRAL HEATING SYSTEMS

SWIMMING POOL HEAT PUMP Owners Manual

INSTALLATION OPERATING & MAINTENANCE MANUAL

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Principals of Condensing Boiler System Design

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

ELECTRIC CENTRAL HEATING FLOW BOILER

Automation System TROVIS 5100 Ventilation Controller TROVIS 5177

Industrial Steam System Process Control Schemes

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

HCE80/HCC80/HCE80R/HCC80R

Features and Benefits

Denver International Airport Total Facility Optimization. Josh Foerschler Aurom Mahobian

Functional Profile: Heat Pump with Temperature Control

Installation Questions

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

presents Hydraulic Separation Beyond Primary / Secondary Piping

MP-4000 Alarm List (Software version or later)

Controller Automation, Model II+

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

Variable Air Volume - VAV

Instruction Sheet X Pump Block (XPB)

HEAT HEAT COOL HEAT PUMP COOL

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

ECOCIAT. Domestic hot water heat recovery unit

Transcription:

verview The CGC Group Hybrid Heat Pump System does NT operate with the same fluid loop temperatures as a conventional reversing Water Source Heat Pump system. The CGC system differs from a WSHP system in that it does not operate the compressor in the heating mode. Instead, each CGC unit has a hot water heating coil to provide heating. As with most hydronic heating systems, the supply fluid temperatures are increased as the outside ambient conditions get colder. The Hybrid loop temperature is maintained at 85 F (29.4 C) when ambient conditions are above 55 F(13 C ). This will allow any CGC unit to deliver a minimum of 30% of its rated heating capacity. As ambient conditions fall below 55 F (13 C),the fluid loop temperatures are increased. The standard rate of increase is 1 F rise in fluid loop temperature for every 2 F drop in ambient temperature. At this rate, the fluid loop temperature would be 108.5 F (42.5 C) at 8 F (-13 C) ambient conditions. ne of the advantages of the CGC system is that the heating output can be scheduled to the actual load. For example, in intermediate seasons, when full heating output is not required, the fluid loop temperature will be scheduled to only deliver the required amount of heat output. This is different than a reversing WSHP that provides full compressor heat regardless of how much heat output is actually required. The CGC Group offers a prepackaged system controller that is custom programmed to accommodate most system arrangements. The CGC system controller is BACnet based and can be integrated into most BAS. Controls by thers Should a third party controller be selected, it must be programmed to provide the functions required by the system. These functions include maintaining both adequate flow rates and the scheduled loop temperatures. We recommend the following algorithms be included. Pumping Architecturally, CGC strongly recommends that the system pumps have full standby. n smaller systems, CGC recommends that two pumps each sized to provide 100% flow be installed. n larger systems, a three pump arrangement each of 50% capacity could be considered, with two pumps operating at all times. With a two pump arrangement we recommend that one operate for the first ½ of the month, and the second be used for last half of the month. Similarly, on a three pump installation, each pump be shut down for a period of 10 days per month. n pump rotation allow a 10 second delay before starting up new pump. Variable flow systems can also be utilized with the addition of unit mounted flow controls, but this is discussed in an additional bulletin. Pump flow shall be monitored by the control panel. CGC recommends that Pressure Differential switches be utilized to provide flow monitoring rather than paddle type flow switches. PD switches are more reliable, do not require system drainage for repair, and are not affected by turbulent flow. A two pump system will require one pressure differential switch installed across the supply and return headers. The three pump arrangement will require three pressure differential switches, which must be installed across each individual pump. The control panel shall command one or more pumps N in accordance with the above schedule. However, should the flow monitor detect a flow failure that exceeds 15 seconds, the panel shall shut down the malfunctioning pump and immediately start up the standby pump. This pump shall be operated continuously whether or not the flow sensor is satisfied, until the algorithm is manually reset. Simultaneously a flow failure alarm shall be sounded. Temperature Control (Set Point) In order to optimize the performance of the FreeHeat system, the temperature of the fluids supplied to the units must be accurately controlled. CGC has developed a series of control algorithms that best satisfy the needs of the system. Three accurate temperature sensors are required. The outside air sensor must be mounted outdoors on a surface that is not ever exposed to the sun. This sensor must be located where it will not be influenced by heat transmission through the walls, exhaust air streams, or nearby heat producing equipment. System return fluid and supply fluid sensors must be installed on the piping where they will not be compromised by cold outdoor air, boiler vents, unit heaters, etc.

Temperature Control (utput) Reversing WSHP systems commonly control the operation of the fluid coolers and boilers from the discharge fluid temperature. This control system however may cause excessive cycling.for staged controlled systems, CGC recommends that the system be controlled from the return fluid temperature sensor in order to maintain system stability. The standard system control algorithms are PID based and arranged as follows: - Primary control is from the return sensor monitoring fluid temperatures returning from the heat pump units. - PID inputs for primary control are Set Point and Return Fluid Temperature TR, is the process variable. - utput for primary control is 0% to 100% over a 20 F change in temperature (or equivalent) - PID integral reset value 10% of offset per minute - 1 st stage of Heat Injection is enabled at 25% PID output, 2 nd stage and beyond are spread out between 25% and 0%. Each stage is disabled at 10% higher value. ie: 1 st stage disabled at 35% - 1 st stage of Heat Rejection is enabled at 75% PID output, 2 nd stage and beyond are spread out between 75% and 100%. Each stage is disabled at 10% lower value. ie: 1 st stage disabled at 65% - 5 Minute inter stage delays should be incorporated into the N staging only.

FREE HEAT 301 Heat Pump Loop Control Panel Mechanical heating capacity. Room: Style 44 The reset rate is adjusted to maximize performance.lower reset rates increase cooling efficiency but reduces the Loop Temp [ F] vs utside Air Temp [ F] 130 Max Loop Temp = 125 [ F] 120 Loop Temperature [ F] 110 100 90 SLPE 1.0 0.9 0.8 Assisted Living 0.7 } 0.6 } 0.5 0.4 0.3 } Hotels ffices Min Loop Temp = 85 [ F] 80-20 -10 0 10 20 30 40 50 60 70 utdoor Air Temperature [ F] The system fluid set point is similar to that for a hot water heating system with the following control logic: - Ambient 55 F (13 C) and above - hold 85 F (29.4 C) fluid temperatures. - Ambient below 55 F (13 C) The fluid set point will be reset upward by the following equation. 85 F + [Reset rate X no. degrees below 55 F] i.e. ambient of 32 F (0 C) and rest rate of 0.5. Fluid set point= 85 F +[ 0.5(55-32) ]= 96.5 F - Nominal reset range.25 to.75 - Maximum fluid setpoint temperature 125 F (52 C)

Advanced Features Modulating equipment such as valves or modulating boilers are best controlled from discharge temperature Ts. Systems with both step control and modulating control should be controlled via the same primary PID output control for the staged outputs with TR as the variable input; but with the addition of a second PID control algorithm that is enabled as a step from the primary PID. This secondary PID will use the same setpoint as the primary PID, but the temperature input variable will be from the discharge fluid temperature sensor Ts. With this arrangement the discharge temperature control will only function when enabled by the primary PID control. vershooting and cycling will be prevented. However, if staging is not required for either heat injection or heat rejection (no steps on heat input or heat rejection), the primary control sensor should be switched to the supply fluid temperature sensor Ts and the second PID algorithm will not be required.