SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY 8d COMMON NAILS @ 6" O.C. EACH SIDE WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION Fig. 2
SIP WALL SUBFLOOR OR COMBINED SUBFLOOR AND UNDERLAYMENT DRAINED AND VENTILATED CLADDING FLOOR JOIST FIELD INSTALLED PANEL BOTTOM PLATE 8d COMMON NAILS @ 6" O.C. BOTH SIDES BE SURE OUTSIDE SKIN IS SUPPORTED BY SILL PLATE CONCRETE OR MASONRY FOUNDATION WALL 16d NAILS INTO SILL PLATE @ 16" O.C. TREATED SILL PLATE SILL SEALER TERMITE SHIELD EACH SIDE OF FRAMING TYP. AS MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS @ 6 FEET O.C. MAXIMUM FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL A Fig. 3
SIP WALL DRAINED AND VENTILATED CLADDING EACH SIDE OF FRAMING TYP. AS 8d COMMON NAILS @ 6" O.C. EACH SIDE CAPILLARY BREAK, MIN. 6 MIL POLY OR MIN. 3/4" PRESSURE- TREATED PLYWOOD UNDER SILL PLATE AND BOTH FACES TERMITE SHIELD FIELD INSTALLED TREATED BOTTOM PLATE MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS @ 6 FEET O.C. MAXIMUM CONCRETE OR MASONRY FOUNDATION WALL FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL B Fig. 4
SIP WALL DRAINED AND VENTILATED CLADDING FIELD INSTALLED TREATED BOTTOM PLATE 8d COMMON NAILS @ 6" O.C. EACH SIDE SUBFLOOR OR COMBINED SUBFLOOR AND UNDERLAYMENT, TYP. FLOOR JOIST 16d NAILS INTO FLOOR JOIST PLATE @ 16" O.C. WHEN USED AS BRACING (3) 16d @ 16 O.C. AT EACH SIDE OF FRAMING TYP. AS USE NAILS PER S RECOMMENDATIONS FOR SIZE AND SPACING CONCRETE OR MASONRY FOUNDATION WALL TREATED SILL PLATE CAPILLARY BREAK, MIN. 6 MIL POLY OR MIN. 3/4" PRESSURE-TREATED PLYWOOD UNDER SILL PLATE AND BOTH FACES ANCHOR BOLT AS REQUIRED BY CODE FOUNDATION CONNECTIONS FOUNDATION CONNECTION DETAIL C Fig. 5
FINISH ROOFING MATERIAL ROOFING FELT EACH SIDE OF FRAMING AND BOTH FACES AS RECOMMENDED BY 8d COMMON NAILS @ 6" O.C. BOTH SIDES FOAM RIDGE CAP SIP ROOF PANEL SEALANT AS SIPS SCREWS WITH 1" MIN. PENETRATION INTO STRUCTURAL SUPPORT @ 24" O.C. MINIMUM SIP TAPE AT RIDGE REQUIRED CONTINUOUS FIELD INSTALLED WOOD RIDGE SUPPORT BEAM SHOWN STRUCTURAL SUPPORT MEMBER WITH MIN. 1-1/2" BEARING FOR EACH SIDE OF PANELS ROOF-TO-ROOF PANEL CONNECTIONS FOAM RIDGE CAP DETAIL Fig. 6
FINISHED ROOFING MATERIAL ROOFING FELT MINIMUM 3/8" GAP FOR SEALANT AS BLOCKING AS REQUIRED BY STRUCTURAL CONDITIONS SIPS SCREWS W/ MINIMUM 1" PENETRATION INTO STRUCTURAL SUPPORT @ 24" O.C. MINIMUM SIP TAPE AT RIDGE REQUIRED RIDGE SUPPORT BEAM ROOF-TO-ROOF PANEL CONNECTIONS BEVELED SIP RIDGE DETAIL Fig. 7
PANEL SCREW FINISHED ROOFING MATERIAL ROOFING FELT SIP ROOF PANEL CONTINUOUS SEALANT EACH SIDE OF FRAMING AS RECOMMENDED BY, AND ROOF PANEL 2x JOINT 8d COMMON NAILS @ 6" O.C. EACH SIDE TOP PLATE SIP WALL PANEL DRAINED AND VENTILATED CLADDING ROOF-TO-WALL PANEL CONNECTIONS BEVELED SIP WALL Fig. 8
WEDGE INFILL PIECE PANEL SCREW FINISHED ROOFING MATERIAL ROOFING FELT SIP ROOF PANEL EACH SIDE OF FRAMING AS CONTINUOUS SEALANT EACH SIDE OF FRAMING, AND ROOF PANEL 2x JOINT TOP PLATE SIP WALL PANEL DRAINED AND VENTILATED CLADDING 8d COMMON NAILS @ 6" O.C. BOTH SIDES EACH SIDE OF FRAMING AS ROOF-TO-WALL PANEL CONNECTIONS WEDGE INFILL PIECE Fig. 10
8d COMMON NAILS 6" O.C. BOTH SIDES TYPICAL AS FINISHED ROOFING MATERIAL BOTH SIDES TYP. OF FRAMING AS RECOMMENDED BY 16d COMMON NAILS @ 16" O.C. ROOFING FELT SIP TAPE AT RIDGE REQUIRED ROOF-TO-ROOF PANEL CONNECTIONS RIDGE DETAIL AT CANTILEVER (LIMIT 2' OVERHANG) Fig. 11
SIP WALL PANEL SECOND FLOOR STANDARD WIRE CHASE 16d COMMON NAILS @ 16" O.C. WHEN USED AS BRACING (3) 16d COMMON NAILS @ 16" O.C. DRAINED AND VENTILATED CLADDING 2x BOTTOM PLATE 8d COMMON NAILS @ 6" O.C. BOTH SIDES EACH SIDE OF FRAMING TYP. AS 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND OVER TOP OF SIP WALL FLOOR JOISTS METAL STRAP AS REQUIRED OR LTP4 SIMPSON CLIP CAP PLATE EACH SIDE OF FRAMING TYP. AS TOP FLANGE METAL FLOOR JOIST HANGAR (BY OTHERS) FIRST FLOOR 2ND FLOOR CONNECTION DETAILS HANGING FLOOR Fig. 12
SIP WALL PANEL SECOND FLOOR STANDARD WIRE CHASE DRAINED AND VENTILATED CLADDING 16d COMMON NAILS @ 16" O.C. WHEN USED AS BRACING (3) 16d COMMON NAILS @ 16" O.C. 2x BOTTOM PLATE 8d COMMON NAILS @ 6" O.C. BOTH SIDES INSULATION 3/4" T&G FLOOR SHEATHING (GLUED & NAILED) TO EXTEND OVER TOP OF SIP WALL FLOOR JOISTS (I-JOIST SHOWN) METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD RIM BOARD METAL LATERAL TIE PLATE NAILED TO BOTTOM OR SHIM PLATES AND RIM BOARD 8d COMMON NAILS @ 6" O.C. BOTH SIDES FIRST FLOOR EACH SIDE OF FRAMING TYP. AS CAP PLATE AS REQUIRED BY EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY 2ND FLOOR CONNECTION DETAILS RIM BOARD Fig. 13
SIP ROOF PANEL ROOFING FELT FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA. CONTINUOUS SEALANT EACH SIDE OF FRAMING TYP. AS AS DRIP EDGE FLASHING ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE FASCIA SOFFIT BOARD EAVES DETAILING EAVES DETAIL A Fig. 14
SIP ROOF PANEL ROOFING FELT AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FINISHED ROOFING MATERIAL DRIP EDGE FLASHING AS 2X BLOCKING TO SUPPORT FASCIA BOARD ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE 8d COMMON NAILS @ 6" O.C. BOTH SIDES FASCIA 2x FRAMING MEMBER SOFFIT BOARD SIP SCREW EAVES DETAILING EAVES DETAIL B Fig. 15
ROOFING FELT SIP ROOF PANEL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA. FINISHED ROOFING MATERIAL EACH SIDE OF FRAMING TYP. DRIP EDGE 2x FRAMING MEMBER USE NAILS PER 'S RECOMMENDATIONS FOR SIZE AND SPACING. 2x FRAMING MEMBER FASCIA SOFFIT BOARD 8d COMMON NAILS @ 6" O.C. BOTH SIDES SIP SCREW EAVES DETAILING EAVES DETAIL C Fig. 16
AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA EACH SIDE OF FRAMING TYP. AS ROOFING FELT SIP ROOF PANEL FINISHED ROOFING MATERIAL DRIP EDGE FLASHING BEVELED BLOCKING TO SUPPORT FASCIA BOARD 8d COMMON NAILS @ 6" O.C. BOTH SIDES AS ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE FASCIA SOFFIT BOARD USE NAILS PER 'S RECOMMENDATIONS FOR SIZE AND SPACING. EAVES DETAILING EAVES DETAIL D Fig. 17
FINISHED ROOFING MATERIAL AS REQUIRED, EXTEND ICE AND WATER SHIELD FROM FASCIA EACH SIDE OF FRAMING TYP. AS ROOFING FELT SIP ROOF PANEL DRIP EDGE 8d COMMON NAILS @ 6" O.C. BOTH SIDES AS ROOF-TO-WALL PANEL CONNECTION DETAIL SHOWN ELSEWHERE FASCIA SOFFIT BOARD USE NAILS PER 'S RECOMMENDATIONS FOR SIZE AND SPACING. EAVES DETAILING EAVES DETAIL E Fig. 18
EACH SIDE OF FRAMING TYP. AS SIP PANEL EXPANSION GAP 1/8" 8d COMMON NAILS @ 6" O.C. EACH STRIP AND EACH SIDE SEALANT AS RECOMMENDED BY CHASE FOR EXPANDED FOAM SEALANT WALL-TO-WALL VERTICAL PANEL CONNECTIONS SURFACE SPLINE FOR VERTICAL SPLICE Fig. 19
2x FRAMING AROUND WINDOWS AND DOOR OPENINGS DOOR AND WINDOW FRAMING Fig. 21
(2) ROWS 16d COMMON NAILS@ 16" O.C. MINIMUM SIP PANEL EXPANSION GAP 1/8" 8d COMMON NAILS @ 6" O.C. EACH PANEL AND EACH SIDE EACH SIDE OF FRAMING TYP. AS WALL-TO-WALL VERTICAL PANEL CONNECTIONS DIMENSIONAL LUMBER SPLINE Fig. 20
EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY VALLEY FLASHING DOUBLE 2x SPLINE BEVEL CUT SIP ROOF PANEL 16d COMMON NAILS @ 16" O.C. MINIMUM 8d COMMON NAILS @ 6" O.C. EACH PANEL AND EACH SIDE EACH SIDE OF FRAMING TYP. AS AT SUPPORT MEMBERS SIPS SCREW W/ MINIMUM 1" PENETRATION INTO STRUCTURAL SUPPORT STRUCTURAL SUPPORT SIP TAPE ROOF-TO-ROOF PANEL CONNECTIONS VALLEY DETAIL Fig. 22
SIP PANEL EXPANSION GAP 1/8" 8d COMMON NAILS @ 6" O.C. EACH PANEL AND EACH SIDE EACH SIDE OF FRAMING TYP. AS BLOCK SPLINE WALL-TO-WALL VERTICAL PANEL CONNECTIONS BLOCK SPLINE Fig. 23