CQM1-SF200/CS1W-SF200



Similar documents
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

SPST-NO SPDT DPST-NO DPDT

Original instructions Tina 3A/Aps Adaptor unit

Safety Manual BT50(T) Safety relay / Expansion relay

Tina 2A/B Adaptor unit

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

Smile 11 AS-i Emergency stop with safe AS-i input node

General-purpose Relays

Phase-sequence Phase-loss Relay

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

Liquid Leakage Sensor Amplifier

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Type Terminal Coil Contact form Model

NX safety stand-alone

SPST-NO SPDT DPST-NO DPDT

WE70. FA Wireless LAN Unit. Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE a/b/g

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

Solid State Relays for Heaters

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Model Number Structure

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals

Machine Automation Controller NJ-series. Startup Guide. for Motion Control W514-E1-01

Model Number Structure

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Digital input modules

Ordering Information. Specifications. Electrode Holder Electrode Holders. Accessories (Order Separately)

Advantium 2 Plus Alarm

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

CompactLogix Power Supplies Specifications

Smart DeviceNet Remote I/O Terminals

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

Type: DILM32 10(24V50HZ) Article No.:

38 Series - Relay interface modules A

Multifunction Digital Timer

G6K-2F G6K-2F-Y G6KU-2F-Y

Type: DILM9 10(24VDC) Article No.:

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Solid-State Timer H3G

Relés e Contatores de Estado Sólido SIRIUS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Surface Mounting Relay

RM4TG20 three-phase network control relay RM4-T - range V

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

Type: DILM50(230V50HZ,240V60HZ) Article No.:

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Tab (#110) terminal Actuator

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Solid State Relays with Built-in Current Transformer

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

Absolute Rotary Encoder E6CP

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Electronic overload relay EF19 and EF45

Thermal-Magnetic Circuit Breaker M1-..

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

DLP-PU/E Instruction Manual

Capacitive Prox E2K-X

SKR - industry relay

38 Series - Relay interface modules A

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

48 SERIES Relay interface modules 10 A

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

ZC-24DO CANopen I/O Module: 24 Digital Outputs

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

EXTERNAL DIMENSIONS AND PARTS

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Proximity Sensor with All-stainless Housing

Safety automation solutions

General-purpose Relay

Knob Potentiometer with Switch

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

40 Series - Miniature PCB/Plug-in relays A. Features

How To Read A Pipe From A Sensor

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Electronic overload relay EF65, EF96 and EF146

Transcription:

Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and CS1-series s. Requires less installation space and wiring. Monitors power supply, output, and internal relays for safety circuits. Equipped with four general-purpose input terminals. Conforms to EN standards. (TÜV certification) Be sure to read the Safety Precautions on page 8. Model Number Structure Model Number Legend: CQM1-@@@@@ 1 2 3 4 CQM1: CQM1 I/O Unit Type CS1W-@@@@@ 1 2 3 4 CS1W: CS1 I/O Unit Type 1. Function SF: I/O Unit Type Emergency-stop Unit 2. Contact Configuration (Safety Output) 2: DPST-NO 3. Contact Configuration (OFF-delay Output) 0: None 4. Contact Configuration (Auxiliary Output) 0: None Ordering Information I/O Unit Type Emergency-stop Unit Main contact Rated voltage Auxiliary contact DPST-NO VDC None Number of input channels 1 channel or 2 channels possible Number of generalpurpose inputs 4 inputs Model CQM1-SF200 CS1W-SF200 1

Specifications CQM1-SF200/CS1W-SF200 Ratings (Safety Circuit Block) Power Input Item Model CQM1-SF200 CS1W-SF200 Power supply voltage Operating voltage range Power consumption Inputs Contacts VDC 85% to 110% of rated power supply voltage VDC: 1.7 W max. Item Model CQM1-SF200 CS1W-SF200 Input current Model 75 ma max. CQM1-SF200, CS1W-SF200 Item Load Resistive load Inductive load Rated load 250 VAC, 5 A 30 VDC, 5 A 15 VAC: 0 VAC, 2 A (cosφ=0.3) 13 VDC: VDC, 1 A (L/R=48 ms) Rated carry current 5 A 5 A Ratings (General-purpose Input Block) Item Model CQM1-SF200 CS1W-SF200 Power supply voltage Operating voltage range VDC 85% to 110% of rated power supply voltage Input impedance 4.0 kω 3.3 kω Input current 6 ma (typical) at VDC 7 ma (typical) at VDC Must-operate voltage/current Reset voltage/ current ON/OFF response time Number of circuits Simultaneous ON points Internal current consumption 8 ms max. (Settable in the range 1 to 128 ms in the Setup.) 14.4 VDC min./3 ma min. 5 VDC max./1 ma max. 4 inputs, 1 common All points 8 ms max. (Settable in the range 0 to 32 ms in the Setup.) 50 ma max. 100 ma max. 2

CQM1-SF200/CS1W-SF200 Characteristics Item Model CQM1-SF200 CS1W-SF200 Contact resistance *1 Operating time *2 Response time *3 Insulation resistance *4 Dielectric strength *4 Vibration resistance *4 Shock resistance *4 Durability Failure rate (P level) (reference value) *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. *2. Not including bounce time. *3. The response time is the time it takes for the main contact to turn OFF after the input is turned OFF. Includes bounce time. *4. Measured with the Unit mounted to the. Connections Mechanical Electrical 100 mω max. 300 ms max. 10 ms max. Between safety circuits and safety output: 20 MΩ min. (at 500 VDC) Between general-purpose inputs and safety output: 20 MΩ min. (at 500 VDC) Between different poles of safety output: 20 MΩ min. (at 500 VDC) Between safety circuits and general-purpose inputs: 20 MΩ min. (at 500 VDC) Between safety circuits and safety output: 2,500 VAC, 50/60 Hz for 1 min Between general-purpose inputs and safety output: 2,500 VAC, 50/60 Hz for 1 min Between different poles of safety output: 2,500 VAC, 50/60 Hz for 1 min Between safety circuits and general-purpose inputs: 500 VAC, 50/60 Hz for 1 min 10 to 57 Hz at 0.075-mm single amplitude, 57 to 150 Hz at 9.8 m/s 2 for 80 minutes each in X, Y, and Z directions (sweep time 8 minutes 10 = 80 minutes) Conforms to JIS C0040. 147 m/s 2, 3 times each in X, Y, and Z directions, Conforms to JIS C0041. 5,000,000 operations min. (at approx. 7,200 operations/h) 100,000 operations min. (at approx. 1,800 operations/h) 5 VDC, 1 ma Ambient operating temperature *4 0 to 55 C Ambient operating humidity *4 Ambient operating environment *4 10% to 90% (with no condensation) No corrosive gases Ambient storage temperature *4 20 to 75 C Structure Built into panel 10 to 57 Hz at 0.075-mm single amplitude, 57 to 150 Hz at 9.8 m/s 2 for 80 minutes each in X, Y, and Z directions (sweep time 8 minutes 10 = 80 minutes) (when mounted on DIN track: 2 to 55 Hz, 2.94 m/s 2 for 20 minutes each in X, Y, and Z directions) Conforms to JIS C0040. 147 m/s 2, 3 times each in X, Y, and Z directions, Conforms to JIS C0041. Weight Approx. 260 g Approx. 300 g Terminal Arrangement Internal Connections CQM1-SF200 CS1W-SF200 *1 NC A1 A2 T11 T12 PWR Safety circuit block B1 T21 T22 Y1 Internal circuit X1 13 14 General-purpose input block 4 7 COM 4.0 kω (3.3 kω) *2 0.01 μf 820Ω *2 (0.01 μf) *2 (470Ω) *1 NC Input indicator *1. The NC terminals are incorporated in the CS1W-SF200 only. *2. Values in parentheses are for the CS1W-SF200. 3

- + - + - + Operation s CQM1-SF200/CS1W-SF200 Color status Operating status Meaning RDY (CQM1-SF200 only) PWR and Green Lit Normal --- Not lit No power supply Green Orange 4, 5, 6, 7 Orange The Unit is recognized by the CQM1H or CQM1 after power is turned ON. Power has not been supplied to the CQM1. The Unit is waiting for initialization. The Unit is being reset. Lit The safety block is turned ON. Power is supplied to the safety block. Not lit The safety block is not turned ON. Power is not supplied to the safety block. Lit The and relays are ON. The and relays are ON. Not lit The and relays are OFF. The and relays are OFF. Lit Input signals are ON. s are ON. Not lit Input signals are OFF. s are OFF. Dimensions (Unit: mm) CQM1-SF200 110 4 5 6 7 T11 Y1 B1 X1 T22 T21 COM T12 A1 A2 14 13 110 DCV 6mA SF200 32 107 3.7 CS1W-SF200 130 35 126 4

Application Examples CQM1-SF200/CS1W-SF200 Two Channels of Emergency Stop Switch Input/Manual Reset (Common to CQM1-SF200 and CS1W-SF200) S1 11 12 21 22 A1 input output A2 T11 T12 PWR S2 B1 T21 Internal circuit Output Unit T22 Y1 X1 13 M 14 Timing Chart Emergency stop switch S1 Reset switch S2 (NC) (NO) and (NC) S1: Emergency stop switch S2: Reset switch (momentary operation switch) and : Magnetic Contactor : G3J Solid-state Contactor M: 3-phase motor Note: This circuit conforms to category 4. and (NO) and (NC) and (NO) input 5

CQM1-SF200/CS1W-SF200 Two Channels of Limit Switch Input/Manual Reset (Common to CQM1-SF200 and CS1W-SF200) S1 S2 11 12 A1 input output open A2 T11 T12 PWR S3 B1 T21 Internal circuit Output Unit T22 Y1 X1 13 M 14 Timing Chart Limit switches S1 and S2 Reset switch S3 (NC) (NO) and (NC) and (NO) and (NC) and (NO) input S1: Limit switch (NO) S2: Safety Limit switch with direct opening mechanism (NC) (D4B-N, D4N, D4F) S3: Reset switch (momentary operation switch) and : Magnetic Contactor : G3J Solid-state Contactor M3: 3-phase motor Note: This circuit conforms to category 4. 6

CQM1-SF200/CS1W-SF200 Two Channels of Limit Switch Input with Auto-reset (Common to CQM1-SF200 and CS1W-SF200) S1 11 12 S2 11 12 A1 input output open A2 T11 T12 PWR B1 T21 Internal circuit Output Unit T22 Y1 X1 13 M 14 Timing Chart Limit switches S1 and S2 (NC) Limit switches S1 and S2 (NO) (NC) (NO) and (NC) and (NO) and (NC) S1: Limit switch (NO) S2: Safety Limit switch with direct opening mechanism (D4B-N, D4N, D4F) and : Magnetic Contactor : G3J Solid-state Contactor M3: 3-phase motor Note: This circuit conforms to category 4. and (NO) input 7

Safety Precautions CQM1-SF200/CS1W-SF200 Refer to the Precautions for All Relays and Precautions for All Relays with Forcibly Guided Contacts. Refer to the CQM1H Catalog (Cat. No. P050) and the CS1-series Catalog (Cat. No. P047) for common performance specifications and precautions.!caution Turn OFF the CQM1-SF200 or CS1W-SF2000 before wiring the Unit. Do not touch the terminals of the Unit while the power is turned ON, because the terminals are charged and may cause an electric shock. Precautions for Correct Use Wiring Use the following to wire the Unit. Stranded wire: 0.75 to 1.5 mm 2 Solid wire: 1.0 to 1.5 mm 2 Tighten each screw to a torque of 0.78 to 1.18 N m, or the Unit may malfunction or generate heat. External inputs connected to T11 and T12, or T21 and T22 of the Relay unit must be no-voltage contact inputs. CS1W-SF200 Addresses are allocated to Basic I/O Units according to the order in which they are mounted on the CPU Block. Addresses (bits) are allocated in word (16-bit) units starting from the left (the position farthest from the ) beginning with word 0000. Note: The 1 to 16-point Units are allocated 16 bits and 17 to 32-point Units are allocated 32 bits. For example, 8-point DC Input Units are allocated bits 00 to 15. CS1W-SF200 is allocated 16 points. 0000 CH Number of slots: 2, 3, 5, 8, or 10 Power Supply Unit Durability of Contact Outputs Relay with Forcibly Guided Contact durability depends greatly on the switching condition. Confirm the actual conditions of operation in which the Relay will be used in order to make sure the permissible number of switching operations. When the accumulated number of operation exceeds its permissible range, it can cause failure of reset of safety control circuit. In such case, please replace the Relay immediately. If the Relay is used continuously without replacing, then it can lead to loss of safety function. Address Allocations CQM1-SF200 Addresses are allocated to Basic I/O Units according to the order in which they are mounted in the CPU Block. Addresses (bits) are allocated in word (16-bit) units starting from the left (the position nearest to the ) beginning with word 0000. Note: The 1 to 16-point Units are allocated 16 bits and 17 to 32-point Units are allocated 32 bits. For example, 8-point DC Input Units are allocated bits 00 to 07. CQM1-SF200 is allocated 16 points. Supply Example Power Supply Unit Slot 0 8-point DC Input Unit 00 01 02 03 04 05 06 07 Address (bit) 000000 000001 000002 000003 000004 000005 000006 000007 Slot 1 Safety Relay Unit 4 5 6 7 Number of slots: 2, 3, 5, 8, or 10 0000 CH 0 1 2 3 4 8 input points Safety Relay Unit 0000 0001 Address (bit) 000100 000101 000102 000103 000104 000105 000106 000107 32 8 32 input output output points points points 0002 to 0003 0100 0101 to 0102 Safety circuit output status monitor Safety circuit power supply status monitor relay operating status monitor relay operating status monitor Example 0 1 2 3 4 8 input points Safety Relay Unit 0000 0001 64 input points Slot 0 8-point DC Input Unit 00 01 02 03 04 05 06 07 0002 to 0005 8 32 output output points points Address (bit) 000000 000001 000002 000003 000004 000005 000006 000007 0006 0007 to 0008 Slot 1 Safety Relay Unit 4 5 6 7 Address (bit) 000100 000101 000102 000103 000104 000105 000106 000107 Power Supply Unit Safety circuit output status monitor Safety circuit power supply status monitor relay operating status monitor relay operating status monitor Applicable Safety Category (EN954-1) CQM1-SF200, CS1W-SF200 meet the requirements of Safety Category 4 of the EN954-1 standards when it is used as shown in the examples provided by OMRON. The Relays may not meet the standards in some operating conditions. The applicable safety category is determined from the whole safety control system. Make sure that the whole safety control system meets EN954-1 requirements. Certified Standards The CQM1-SF200 and CS1W-SF200 conform to the following standards. EN standards, certified by TÜV Product Service EN954-1 EN60204-1 Conformance to EMC (Electromagnetic Compatibility), certified by TÜV Product Service: EMI (Emission): EN55011 Group 1 Class A EMS (Immunity): EN61000-6-2 UL standards: UL508 (Industrial Control Equipment) CSA standards: CSA C22.2 No. 14 (Industrial Control Equipment) 8

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2008.11 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2008 All Right Reserved.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: CQM1-SF200