Capacity Planning in the Modern Datacenter



Similar documents
Uptime is Revenue. ...the average datacenter outage costs about $7900/minute, or roughly $474K/hr. YOUR POWER STRATEGY EXPERTS

Operational Solution for Service Providers deploying Metro Ethernet, Carrier Ethernet or Wireless Ethernet Backhaul Applications.

Gain agility with remote management and reporting.

Data Center Power Distribution at the Cabinet Level: The top 12 questions you need to ask to improve data center energy effciency

Alternating Phase Power Distribution at the Data Center Rack PDU

Server Technology, Inc.

Server Technology Inc.

Server Technology, Inc.

Sentry Power SystemSM. More Intelligent. More Reliable. Easier to Manage.

Server Technology White Paper

One unbelievable solution for rack-level data center power management. Sentry Power Manager. Solutions for the Data Center Equipment Cabinet

Server Technology, Inc.

Who do the biggest names in servers, search, healthcare, cloud & financial services trust to provide power management solutions?

Data Center Infrastructure Management (DCIM) Demystified

(Examples of various colocation sites)

Power Distribution Considerations for Data Center Racks

Applying Data Center Infrastructure Management in Collocation Data Centers

THE KEY TO DATA CENTRE INFRASTRUCTURE

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Energy Management Solutions

Building a power monitoring and management strategy Selecting the software and services needed to keep critical power systems continuously available

What to Consider When Designing Next-Generation Data Centers

Server Technology Inc.

Data Center Infrastructure Management (DCIM)

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

Solutions to Make Your Data Center Energy Effi cient

Data Center Trend: Distributed Power in the White Space

Designing & Managing Reliable IT Services

CenterMind P+ Intelligent Power Management for your Data Center

Energy Savings in the Data Center Starts with Power Monitoring

Data Center Infrastructure Management: ERP for the Data Center Manager

WHITE PAPER Server Innovations: Examining DC Power as an Alternative for Increasing Data Center Efficiency and Reliability

Understanding the Promise of (DCIM)

Data Center of the Future. Is it possible to be Efficient, Reliable and Cost Effective?

Power & Environmental Monitoring

Integrated Wire-Free Solution for Monitoring Power and Environment with RF Code and Sentry Power Manager (SPM)

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

Cheat Sheets to Data Center Infrastructure Management

NIGERIA S PREMIUM DATA CENTRE

Server Technology Inc.

Microsoft Private Cloud Fast Track Reference Architecture

White paper. Control room convergence: Merging industrial monitoring and control systems with data center operations

White Paper. The Top 20 Tools Needed for Hybrid IT

Managing the Data Center One Rack at a Time

Data Centre Infrastructure Assessment

Datacenter Efficiency

How green is your data center?

Zen Internet Case Study

VMware vcloud Powered Services

Colocation and Cloud Hosting Solutions. Build a strong and efficient physical infrastructure that delivers service reliability and profitability

Green Computing: Datacentres

Application Briefs: Remote Office Environment

Case study: End-to-end data centre infrastructure management

Server Technology Intl.

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

Nominee: FieldView Solutions, Inc.

solution brief September 2011 Can You Effectively Plan For The Migration And Management of Systems And Applications on Vblock Platforms?

EX ECUT IV E ST RAT EG Y BR IE F. Server Design for Microsoft s Cloud Infrastructure. Cloud. Resources

Includes customer case study. February 28, 2013

Re Engineering to a "Green" Data Center, with Measurable ROI

Utilizing Temperature Monitoring to Increase Datacenter Cooling Efficiency

Five Reasons to Take Your Virtualization Environment to a New Level

The Benefits of Virtualizing Citrix XenApp with Citrix XenServer

TIA-942 Data Centre Standards Overview WHITE PAPER

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Colocation, Hot Seat Services, Disaster Recovery Services, Secure and Controlled Environment

Intelligent Power Distribution in the Data Center

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

Green Computing: Datacentres

Visualization, Management & Optimization Keys for an efficient Data Center Sergio Uribe - CommScope

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

GUIDELINE. on SERVER CONSOLIDATION and VIRTUALISATION. National Computer Board, 7th Floor Stratton Court, La Poudriere Street, Port Louis

StruxureWare TM Data Center Operation

1. Introduction Availability & types of colocation... 2

Colocation Selection Guide. Workspace Technology Ltd

Integrated Infrastructure Solutions. Building a Data Center for the Future

Data center management suite. Providing optimal control and efficiency to data center management.

Managing Cooling Capacity & Redundancy In Data Centers Today

Improve competiveness of IDC and enterprise data centers with DCIM

DATA CENTER INFRASTRUCTURE MANAGEMENT

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Why Choose VMware vsphere for Desktop Virtualization? WHITE PAPER

Revolutionizing Data Center Infrastructure Management

Veritas Storage Foundation High Availability for Windows by Symantec

Developing a dynamic, real-time IT infrastructure with Red Hat integrated virtualization

Virtualization in a Multipurpose Commercial Data Center

Solution Brief Availability and Recovery Options: Microsoft Exchange Solutions on VMware

In-Guest Monitoring With Microsoft System Center

Data center lifecycle and energy efficiency

APC APPLICATION NOTE #92

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Virtualizing Exchange

StruxureWare for Data Centers

BC43: Virtualization and the Green Factor. Ed Harnish

Power and Cooling Capacity Management for Data Centers

Data Center Power Distribution and Capacity Planning:

Future-Proof the Banking and Finance Data Center

WHITE PAPER: Egenera Cloud Suite for EMC VSPEX. The Proven Solution For Building Cloud Services

Using CFD for optimal thermal management and cooling design in data centers

Transcription:

in the Modern Datacenter SERVER TECHNOLOGY - INDUSTRY BRIEF -001 July 2015 Executive Overview Today s datacenter managers oversee more infrastructure than ever, with an exponential increase in complexity over prior years resulting from the ever changing mix of hardware and software deployed to address the rising demand for data, connectivity, analytics and support for the Internet of Things (IoT). The market forces driving the needs for flexibility, scalability, and efficiency in the datacenter require constant attention and vigilance on the part of the datacenter team to avoid obsolescence, unavailability, and unscheduled downtime. Servers and converged infrastructure are frequently tasked with running multiple virtual machines, loading them to eighty percent or more of their total capacity. Containers such as Docker hold the promise of running even more compute loads on a single server. Meanwhile, operating temperatures of the data center have been allowed to drift upwards of 30 degrees Celsius in the cold aisle, with the hot aisle exhaust temperatures reaching 50-60 degrees Celsius. In this mode of operation, the datacenter operator needs to be aware at all times how much available reserve compute capacity is present. Behind that, knowing how much power is available to support a surge in compute demand, or even where to install the next piece of hardware, is critical to maintaining an efficient, non-stop, mission critical computational environment. Capacity planning is a requirement for any datacenter to operate optimally. Capacity planning for the IT/datacenter industry has a variety of meanings depending on the context in which it is being discussed. When the conversation finally makes its way to power, who is in charge of the discussion Facilities? IT? Both? Your colocation provider? What is the potential demand for power in today s installation versus the actual demand? The frequency with which a datacenter performs capacity planning is determined by the amount of change present. The more frequently it is done, the more tools are needed to support and automate the task. A recent survey of PDU customers revealed that over 30% of PDUs were purchased with the express intent of facilitating the capacity planning process. This industry brief covers some of the challenges of capacity planning and how those challenges can be addressed through a combination of hardware and software tools. FIGURE 1 Results form customer survey question What was your primary reason for purchasing an intelligent PDU.

Challenges The challenges for the datacenter operator are too numerous and too varied for an exhaustive discussion here. The scope of this brief is limited to identifying those challenges associated with capacity planning and the process used to identify where power is available in the datacenter to accommodate additional infrastructure deployment. Here are a few of the power related questions most IT and facilities team are asking themselves on a daily basis: Where is power available to support the installation of additional hardware? How to minimize total power consumption? How do I get the most computation for the least amount of energy? How to get notified when problems occur and automate as much of the corrective response as possible? Is there enough power available to support failover conditions through power path redundancy? How to accommodate daily and seasonal utilization surges? What software tools are available to predict where and when problems are going to occur? These challenges can be summarized in an article published by nlyte, a DCIM tool vendor. For instance, moving a workload to a server that has plenty of CPU but is in a row that doesn t have additional power is worthless. CPU cycles and available watts (and cooling) must exist at the same location for dynamic workload management to be possible. IT professionals are painfully aware that the data center assets change all the time. A conservative estimate of the amount of change may be 25% of all data center mounted devices per year (based on financing, service and warranty schedules). 1 Put simply, datacenter capacity planning ensures that there is sufficient power available to accommodate an average work load with sufficient headroom to meet peak demands. Datacenters are limited in floor space, power, and cooling capacity. A good capacity planning tool provides the operator the ability to quickly identify where power is available to support changing workload and changing hardware deployment. IT teams that are trying to accommodate users capable of cloud scaling and cloud bursting see tremendous swings in hardware and power utilization of nearly 100%, for example. To perform power capacity planning, the IT team must know the following: As-configured potential demand Current actual demand As-configured potential supply Current actual supply 2 Gathering the raw data of power consumption from one or more datacenters and turning that into actionable intelligence is no small feat. Yet this is the very problem that most datacenter operators are routinely faced with managing. This requires a data source (either intelligent power supplies, or intelligent PDUs), a database, an analytics engine, and some form of graphical presentation layer that 1 Mark Harris, nlyte, 2013: http://www.networkworld.com/article/2170953/tech-primers/data-center-infrastructure-management-tools-monitor-everything-and-ease-capacity-planni.html 2 APC White Paper, Neil Rasmussen

YOUR POWER STRATEGY EXPERTS can rapidly present the data in a highly condensed format. The data going into that database and management tool needs to be both historical (for trending purposes) as well as instantaneous, providing a real time view into the status of the datacenter. In the graphic below, the blue circle represents a datacenter where the CDUs are averaging under 40% of their rated capacity. The green dots represent datacenters where the CDUs are operating at 40-60% of capacity. The gray dots represent datacenters that are either offline or in an unknown state. Figure 2 SPM Datacenter view of CDU/PDU Capacity Solutions The steps for performing capacity planning are as follows3 : determine your service level agreements (SLA) analyze current capacity plan for the future On the server and virtual server management side, tools such as vrealize and vsphere from VMware, virt-manager (open source), and Virtual Machine Manager (VMM) from Microsoft, provide the software tools necessary for managing the compute load and server utilization to the highest, most efficient levels possible. 3 http://www.teamquest.com/pdfs/whitepaper/tqeb01.pdf

For power management and power capacity planning, there are a range of tools that provide native support to the various hardware components of the datacenter that are involved in the power supply chain such as the UPS, the busway, and the rack level power distribution unit (PDU). is the leading provider of intelligent PDU products to the datacenter industry, with the broadest array of solutions for the multitude of combinations of voltage, current, outlets, input connectors, and management features that can be requested for any given datacenter. Intelligent PDUS provide a wealth of information, such as input power, outlet status, temperature, and humidity readings. When faced with a datacenter of 25 or more racks full of IT loads, the task of gathering and managing that data can be difficult unless the PDUS are automatically feeding their data into a database and analytics tool. Sentry Power Manager (SPM) from provides a comprehensive look at the state of power usage on the datacenter floor. With its ability to pull in data from thousands of PDUS spread across multiple datacenters, SPM provides the datacenter administrator with the ability to see at a glance the high level instantaneous situation, as well as providing the detailed reporting necessary to develop a forward look at capacity requirements. Figure 3 SPM View of Cabinet Capacity and Redundancy

PRO2 from SPM is the tool to use whenever you need to know: How much power is available in a rack versus how much is being utilized - Figure 3 Is there power remaining on a circuit to accommodate an additional cabinet What is my average historical power consumption in a particular facility What is the trend of power consumption is it going up - Figure 4 How power consumption by the compute load is impacting temperature in the datacenter - Figure 5 Figure 4 Power Trending Figure 5 Temperature Trending

Why? When used for capacity planning, Sentry Power Manager can help a typical server consolidation effort. Server consolidation can result in increased efficiency by: Reducing complexity Reducing capital outlay and asset depreciation Reducing physical infrastructure Increasing manageability Increasing stability/availability Why for is the foremost provider to the datacenter industry of high density, high power intelligent power distribution products. With the best initial quality products provide uncompromising reliability and value for the datacenter. As a leader in product innovation, holds many of the key patents for providing power in a zero-u PDU configuration compatible with today s racks and dense compute infrastructure requirements. For over 30 years, has been recognized as the global leader of innovative, intelligent power distribution products and solutions for data centers, telecommunications operations and branch offices. Over 60,000 customers around the world rely on s cabinet power distribution units (cabinet PDUs, also called CDUs) and power management and measurement solutions to help reduce downtime, improve energy utilization and efficiency. Sentry Power Manager is an award winning software tool from that provides tightly coupled integration with the entire power distribution product line, whether that is AC or DC power. To learn more visit www.servertech.com/spm Getting the most functionality for the dollar spent takes effort. Time spent planning and configuring the power solutions with results in better data, better utilization, and better uptime. - Matthew Adelman, Manager, Global Data Center Operation for Cisco-WebEx (STI) has the most patents in the PDU industry with 48 patents awarded and another 54 pending. Our best in breed PDU s, award winning power management solution, and dedicated customer support are why 97% of our customers buy from us again and again. Your Power Strategy Experts.

Learn More Learn More www.servertech.com See STI White Paper: Advances in Power and Environmental Monitoring for Increasing Efficiency in the Data Center See STI App Note: How do I leverage cabinet PDU information to help plan for growth? Citations & References: 1 Mark Harris, nlyte, 2013: http://www.networkworld.com/article/2170953/tech-primers/data-center-infrastructure-management-tools-monitor-everything-a nd-ease-capacity-planni.html 2 APC White Paper, Neil Rasmussen 3 http://www.teamquest.com/pdfs/whitepaper/tqeb01.pdf Interested in learning more about s solutions? Visit us online at: www.servertech.com/products/ Stay Powered Be Supported Get Ahead From Your Power Strategy Experts HEADQUARTERS NORTH AMERICA 1040 Sandhill Drive Reno, NV 89521 United States Tel: +1.775.284.2000 Fax: +1.775.284.2065 sales@servertech.com www.servertech.com www.servertechblog.com WESTERN EUROPE, MIDDLE EAST & AFRICA Fountain Court 2 Victoria Square Victoria Street St. Albans, AL1 3TF United Kingdom Tel: +44 (0) 1727 884676 Fax: +44 (0) 1727 220815 salesint@servertech.com CENTRAL EUROPE, EASTERN EUROPE & RUSSIA NIEDERLASSUNG DEUTSCHLAND 42119 Wuppertal Germany Tel: +49 202 693917 x0 Fax: +49 202 693917-10 salesint@servertech.com APAC Room 2301, 23/F, Future Plaza 111-113 How Ming Street, Kwun Tong, Hong Kong Tel: +852 3916 2048 Fax: +852 3916 2002 salesint@servertech.com 2015, Inc. Version 7/6/15. Sentry and are registered trademarks of Incorporated. Information is subject to change without notice. Printed in USA. offers a wide range of products for North America and Global markets. For more information visit our website at www.servertech.com