Langendorf Supply Company, Inc. St Louis Office: 4653 Crossroads Industrial Drive Bridgeton, MO 63044 Phone: 314-291-4892 Fax: 314-291-7815 Web Page: www.lsco-inc.com Email: lsco@lsco-inc.com Toll Free 866-489-4892 www.lindabusa.com Spiral Ductwork Gasket Self Sealing Fittings Grilles Drum Louvers www.lorencook.com Exhaust & Supply Fans Blowers & Ventilators Gravity Vents Energy Recovery Units www.titus-hvac.com Grilles, Registers and Diffusers Terminal Units Fan Coil Units www.ruskin.com Control Dampers Fire, Smoke and Fire/Smoke Dampers Louvers Duct Access Doors www.ductsox.com Fabric Air Dispersion System www.gripple.com Cable Support System for Duct and Equipment www.kees.com Security Bars & Grilles Kitchen Hoods www.fantech.net Orifice damper - Combination Flow Measuring & Balance In-line Centrifugal Duct Fan www.asicontrols.com Configurable System Controllers Pre-Programmed Package AC Controllers Variable Air Volume Controllers www.sbt.siemens.com HVAC Variable Frequency Drives www.thermalcoreinc.com Low Temperature Air Diffusers www.reliablehvac.com Grilles, Registers and Diffusers www.doncoair.com Diffusers Bar Grilles Square to Rounds www.qmarkmep.com Electric Heaters, Fans and Air Circulators www.dayus.com Plastic Grilles and Registers www.thermolec.com Electric Duct Heaters, SCR Control www.ajmfg.com Stainless Steel Grilles, Registers and Diffusers www.veco-ny.com Seismic Isolators www.marsair.com Air Doors and Curtains www.smcduct.com Spin-in Collars Airtites (EZ-Taps) www.flexibletechnologies.com Flex Duct & Accessories www.nordfab.com Quick-fit Duct Fitting Clamping System www.ruskinsound.com Sound Attenuators Transfer Ducts Sound Panels www.hartandcooley.com Grilles, Registers and Diffusers Baseboard Grilles www.herculesindustries.com High Efficiency Take-Offs www.lc-systems.com Air Units Kitchen Exhaust Hoods * Dampers wwwwww.flaktwoods.com Tunnel Fans Industrial Blowers www.seiho.com Spot Diffusers Round Registers Vents www.youngregulator.com Remote Cable Control Devices * Damper Controls www.dsp-monoxivent.com Dust, Vehicle & Fume Collection Equipment www.plastecvent.com Polypropylene Fans & Accessories www.tutco.com Electric Duct Heaters www.milcorinc.com Access Doors Heat/Smoke Vents Hatches www.spaceray.com Infrared Gas Heaters Ceramic Heaters www.poweredaire.com Air Doors/Curtains - Opt Heat: direct/ indirect heat, indirect gas, electric, steam and hot water www.rpscurbs.com Roof Curbs, Equipment Rails, Pipe Supports www.donaldson.com Dust & Fume Collection Equipment www.markserv.com Duct/Pipe/Equipment Markers Valve Tags Equipment Name Plates Signs www.continentalfan.com Iris Damper - Flow Measuring & Balancing Types In-line Centrifugal Duct Fans www.plasticair.com Fans & Exhauster (FRP & Polypropylene)
Langendorf Supply Co., Inc. Web Page: www.lsco-inc.com Email: lsco@lsco-inc.com St Louis Office 4653 Crossroads Industrial Dr Bridgeton, MO 63044 Phone: 314-291-4892 Fax: 314-291-7815 Toll Free: 866-489-4892 Name Ext Title Email Ken Arnsmeyer 305 Principal karnsmeyer@lsco-inc.com ACCOUNTING SALES TEAMS Name Ext Title Email Susan Schniepp 302 Accounting sschniepp@lsco-inc.com Kristi Schniepp 301 Accounting Assistant kschniepp@lsco-inc.com Laura Hufendick 330 Accounting Assistant lhufendick@lsco-inc.com Dawn Schmidt 300 Reception dschmidt@lsco-inc.com Name Ext Title Email Neil Gray 304 Sales ngray@lsco-inc.com Cheryl Meehan 318 Sales cmeehan@lsco-inc.com Kim Dickey 327 Sales Assistant /CSR kdickey@lsco-inc.com Name Ext Title Email Gary Smith 303 Sales smittie@lsco-inc.com Ryan Elley 319 Sales relley@lsco-inc.com Krista Arnsmeyer 333 Sales / Tech kla@lsco-inc.com Beth Jones 311 Sales Asistant / CSR bjones@lsco-inc.com Name Ext Title Email Jim Fahrenhorst 309 Sales jfahren@lsco-inc.com Ed Wort 310 Sales ewort@lsco-inc.om Becky Wilburn 308 Sales Assistant / CSR bwilburn@lsco-inc.com Name Ext Title Email Pat Olwig 313 Sales polwig@lsco-inc.com Aaron Schweiss 331 Sales aschweiss@lsco-inc.com Tom Finder 306 Sales tfi nder@lsco-inc.com Lisa Hurley Sales Asistant / CSR lhurley@lsco-inc.com ENGINEERING Name Ext Title Email Steve Liescheidt 317 Engineer, PE stevel@lsco-inc.com ESTIMATING WAREHOUSE NEXTEL ID# 37156 PH# 314-486-5717 Name Ext Title Email Doug Miles 328 Estimating dmiles@lsco-inc.com Jeff Casey Estimating jcasey@lsco-inc.com Name Ext Title Email Bryan Talley 312 Warehouse warehouse-stl@lsco-inc.com Lou Kranung 312 Warehouse warehouse-stl@lsco-inc.com
Langendorf Supply Co., Inc. Web Page: www.lsco-inc.com Email: lsco@lsco-inc.com Peoria Office 2000 West Pioneer Parkway Peoria, IL 61615 Phone: 309-693-0731 Fax: 309-693-0767 Name Ext Title Email Tom Mueller 2 Sales tmueller@lsco-inc.com Mike Lalumandier 3 Sales mlalumandier@lsco-inc.com Felicia Clingan 1 Inside Sales fclingan@lsco-inc.com Indianapolis Office 9208 East 33rd Street Indianapolis, IN 46235 Phone: 317-890-9601 Fax: 317-890-9612 Toll Free: 866-338-9601 Name Ext Title Email Steve Hannoy Sales shannoy@lsco-inc.com Denise Beyer Inside Sales dbeyer@lsco-inc.com
Table of Contents Titus Pages 1-11 GRD... Pages 1-5 HART & COOLEY Grille... Page 2 Dampers... Page 6 VAV Air Terminals... Page 8-10 Accessories... Page 11 ASI Control Page 12 Loren Cook Page 13-18 Roof Exhauster... Page 13 Accessories... Page 14 Gemini Fams... Page 15 Accessories... Page 16-18 Ruskin Page 19-21 Fire Dampers... Page 19-20 Access Doors... Page 21 Lindab Page 22-27 Elbows... Page 22 Reducers... Page 23 Saddle Taps... Page 24 Tees... Page 25 Couplings... Page 25 End Caps... Page 26 Take-offs... Page 26 Starting Collar... Page 26 Dampers... Page 27 Supply Registers... Page 27 Spiral Duct... Page 27 Thermaflex Page 28-29 Insulated FlexDuct... Page 28 Non-Insulated FlexDuct... Page 29 Stainless Steel Band... Page 29 Hercules Page 30 Take Offs... Page 30 Milcor Page 30 Access Doors... Page 30 Sheet Metal Connectors Page 31 Spin-In... Page 31 EZ Tap... Page 31 R & J Manufacturers Page 31 Square to Round... Page 31 Gripple Page 32 Intertape Anchor Duct Tape Page 32 Advanced Cable Ties Page 33 Panduit Page 33 Flanders Filters Page 34 Pre-Pleat Filters... Page 34 HD Industrial Fliters... Page 34 Shipping Information... Page 35 Common Formulas... Pages 36-37 Index... Page 38-39 Langendorf is Proud to Represent many UL, SMACNA, ADC and other Certified Products! www.ul.com www.smacna.org www.greenguard.org www.ashrae.org www.flexibleduct.org Disclaimers: Install products per manufacturer s installation instructions (usually found on manufacturer s website or call us for installation instructions) - Lindab s Leakage Guarentee Warrenty only valid if installed per Lindab s installation instructions All dimensions in catalog are in inches unless otherwise stated All Products shown as we stock them, call us for additional options and products Repair parts for many stocked items are also available in stock
White Finish (#26) Roll Formed Steel 3/4 Blade Spacing Double Deflection Individually Adjustable Blades Countersunk Screw Holes Front Blades Parallel to Short Dimension AG-15 Damper Included (Page 6 ) White Finish (#26) Roll Formed Steel 3/4 Blade Spacing 35 Degree Fixed Deflection Reinforced Corners Lay in Frame (No Screw Holes) Blades Parallel to Long Dimension Optional AG-15 Damper (Page 6) Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) White Finish (#26) Roll Formed Steel 3/4 Blade Spacing 35 Degree Fixed Deflection Reinforced Corners Countersunk Screw Holes (Surface Mount) Blades Parallel to Long Dimension Optional AG-15 Damper (Page 6) * Indicates that fitting damper is in stock Nominal Duct Size 8 x 4 20 x 8 10 x 4 24 x 8 12 x 4 30 x 8 6 x 6 36 x 8 8 x 6 10 x 10 10 x 6 12 x 10 12 x 6 14 x 10 14 x 6 16 x 10 16 x 6 18 x 10 18 x 6 20 x 10 20 x 6 24 x 10 24 x 6 30 x 10 30 x 6 36 x 10 36 x 6 12 x 12 8 x 8 14 x 12 10 x 8 16 x 12 12 x 8 18 x 12 14 x 8 24 x 12 16 x 8 30 x 12 18 x 8 36 x 12 14 x 14 Nominal Duct Size Module 22 x 6 24 x 8 22 x 8 24 x 10 22 x 10 24 x 12 22 x 12 24 x 14 22 x 22* 24 x 24 * Indicates that fitting damper is in stock Nominal Duct Size 8 x 4 12 x 10 10 x 4 14 x 10 6 x 6* 16 x 10 8 x 6 24 x 10 10 x 6 12 x 12* 12 x 6 14 x 12 14 x 6 18 x 12 16 x 6 24 x 12 20 x 6 30 x 12 32 x 6 36 x 12 8 x 8* 14 x 14* 10 x 8 16 x 16* 12 x 8 18 x 18* 14 x 8 24 x 18 16 x 8 30 x 18 18 x 8 24 x 24 24 x 8 30 x 24 10 x 10* 36 x 24 White Finish (#26) Aluminum Border 1/2 x 1/2 x 1/2 Aluminum Core High Free Area Core Minimized Pressure Drop Lay in Border Matches general appearance of parabolic lighting fixtures Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) Nominal Duct Size Module 22 x 10 24 x 12 22 x 22* 24 x 24 22 x 46 24 x 48
White Finish (#26) Aluminum Border and Filter Frame (1 inch) 1/2 x 1/2 x 1/2 Aluminum Core High Free Area Core Minimized Pressure Drop Lay in Border Hidden Screw Holes 1 Filter (optional) See Page 34 Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) Nominal Duct Size Module 20 x 20 24 x 24 White Finish (#26) Roll Formed Steel 3/4 Blade Spacing 35 Degree Fixed Deflection Lay in Border Blades Parallel to Long Dimension 1 Filter (optional) See Page 34 Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) Nominal Duct Size Module 20 x 20 24 x 24 Steel construction Lanced face design Flushed, removable face with concealed latches and hinges, can be installed in any direction Uses 1 thick disposable filters (not included) Bright White Finish Nominal Duct Size 20 x 20 2
Pattern Contollers (#22) Discharge Pattern is adjustable to vertical and 1, 2, 3, or 4-way horizontal Lay in Border Heavy Gauged Steel Backpan and Steel Panel Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) Nominal Duct Size Module Size 6 12 x 12 6 12 x 24 6 20 x 20 8 20 x 20 10 20 x 20 12 20 x 20 14 20 x 20 6 24 x 24 8 24 x 24 10 24 x 24 12 24 x 24 14 24 x 24 16 24 x 24 White Face w/ Black Backpan and Black Pattern Contollers (#22) Discharge Pattern is adjustable to vertical and 1, 2, 3, or 4-way horizontal Lay in Border Heavy Gauged Steel Backpan and Steel Panel Nominal Duct Size Module 6 24 x 24 8 24 x 24 10 24 x 24 12 24 x 24 14 24 x 24 16 24 x 24 Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) Nominal Duct Size Module Size 10 x 10 12 x 12 10 x 22 12 x 24 18 x 18 20 x 20 22 x 22 24 x 24 White Face w/ Black Backpan (#22) Lay in Border Heavy Gauged Steel Backpan and Steel Panel Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) White Face w/ Black Backpan (#22) Lay in Border Heavy Gauged Steel Backpan and Steel Panel Neck Size Module 22 x 22 24 x 24 Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) Lay in Border No Backpan Module 24 x 24 Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) 3
Surface Mount Nominal Duct Size Frame Pattern 6 x 6 9 x 9 12 x 12 15 x 15 18 x 18 Surface Mount Bevel Drop Face Lay-in Surface Mount Bevel Drop Face Lay-in Surface Mount Bevel Drop Face Lay-in Surface Mount Bevel Drop Face Lay-in Surface Mount Bevel Drop Face Lay-in 1 way 2 way Corner 2 way Opposite 3 way 4 way 1 way 2 way Corner 2 way Opposite 3 way 4 way 1 way 2 way Corner 2 way Opposite 3 way 4 way 1 way 2 way Corner 2 way Opposite 3 way 4 way 1 way 2 way Corner 2 way Opposite 3 way 4 way 1Way 2 Way Opposite 2 Way Corner Lay-in White Finish (#26) Fixed Discharge Optional square to round adapter (Page 31) Optional AG-95 Damper (Page 6) 4 Way 3Way White Finish (#26) Deliver supply air in a true 360 degree pattern excellent performance in VAV systems Optional D-100/AG-75 Damper (Page 6) Optional R-6 Molded Insulation (Page 7) Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) Nominal Duct Size Module 6 24 x 24 8 24 x 24 10 24 x 24 12 24 x 24 14 24 x 24 White Finish (#26) Fixed Discharge Pattern For Variable Air Volume systems (excellent turn down for VAV systems) Optional D-100/AG-75 Damper (Page 6) Optional R-6 Molded Insulation (Page 7) Optional TRM Rapid Mount Frame for Surface Mounting (Page 7) Nominal Duct Size Module 6 24 x 24 8 24 x 24 10 24 x 24 12 24 x 24 14 24 x 24 4
#26 White Tees, Black Pattern Controllers Project a uniform blanket of air that adheres to the ceiling even at low flow rates. Excellent for VAV Applications. Direction and Volume are adjustable by moving the pattern controllers Aluminum 1 Slot Border Style 2A Length Slots 48" 2 48" 3 48" 4 72" 2 72" 3 72" 4 White Tees w/ Black Pattern Controllers Lay in Border Non-insulated All Stocked have 1 Slots Optional PF Plaster Frame for Surface Mount(Page 7) TBD10 Aerodynamically Curved Blades High Capacity TBD80 Gasket Edge Blade (directional control) Airflow Direction is Adjustable through Face Dimensions Inlet Option Diffuser L W H Inlet A B Option No. Slots No. Tees TBD 10 24 2 8 6 6 1/4 5 1/4 1 1 1 TBD 10 24 4 8 6 6 1/4 5 1/4 5 2 2 TBD 10 24 4 8 8 9 3/8 5 1/4 3 2 3 TBD 10 24 4 8 8 9 3/8 5 1/4 5 2 2 TBD 10 48 2 8 6 6 1/4 5 1/4 1 1 1 TBD 10 48 4 8 8 9 3/8 5 1/4 3 2 3 TBD 10 48 4 8 8 9 3/8 5 1/4 5 2 2 TBD 10 48 4 8 10 12 1/2 5 1/4 3 2 3 TBD 10 48 4 8 10 12 1/2 5 1/4 5 2 2 TBD 10 48 4 8 12 15 9/16 5 1/4 5 2 2 TBD 80 48 6 8 10 12 1/2 5 1/4 3 3 4 TBD 80 48 8 8 12 15 9/16 5 1/4 3 4 5 5
Mill Finish Galvanized Steel Uses Steel S-clips for easy Mounting and Removal Nominal Duct Size 6 x 6 8 x 8 10 x 10 12 x 12 14 x 14 16 x 16 18 x 18 22 x 22 Slot Operated For use with 300/350 Grilles and Registers Mill Finish Galvanized Steel Neck Mounted Operating Lever Accessibility Nominal Duct Size 6 x 6 9 x 9 12 x 12 15 x 15 18 x 18 22 x 22 Uses Sheet Metal Screws for Mounting For use with TDC Diffusers Opposed Blade (four sets) Mounted Directly into Hard Duct above Diffuser Neck Adjustable from face side of Diffuser Nominal Duct Size 14 16 For use with PAS, TMS, or OMNI Diffusers Gang operated radial blades Mounted Directly on the diffuser neck Used with Flex Duct or where height is limited Nominal Duct Size 6 8 10 12 14 6
Insulation is R-6 where blanket has most depth 1 clearance on each side of neck for insulated duct connection Fits TMS and OMNI, size 24 x 24 Size 24 x 24 Die cut for various neck sizes To convert lay-in diffusers to surface mount For installation in Plaster and Sheet Rock Ceilings Similar features as a T-bar installation Adjustable fastening clips Module Size 12 x 12 20 x 20 24 x 12 24 x 24 Access Door alternative for entry to the plenum space above the ceiling (by lifting lay-in air device) To convert lay-in plenum diffusers (TBD10/80) to surface mount For installation in Plaster and Sheet Rock Ceilings Similar features as a T-bar installation Adjustable fastening clips Length Slots 24 1 24 2 48 1 48 2 48 3 48 4 7
Standard Features Titus AeroCross multi-point, center averaging velocity sensor for accuracy 1/2 2lb matte face lining standard Beaded inlet collar for consistent roundness 22 gauge casing with slip and drive connections standard Pressure independent control TA1 Controller for all standard control strategies (see below) 24 Vac tri-state damper actuator Operates up to 3 stages of reheat Controls 0-10 Vdc proportional hot water valves Controls 24 Vac on/off auxiliary heat Optional Features Water Coils (Page 11) Thermostat (Page 11) Control Strategy Control Code Thermostat Additional Components Required Cooling Only AT31 102696-01 (CTE-5101) None Cooling With Electric Heat AT33 102696-04 (CTE-5104) None Cooling with Auxilary Heat AT33 102696-04 (CTE-5104) None Heating/Cooling Autochangeover AT34 102696-03 (CTE-5103) 103065-01 (Duct Thermistor) Cooling with Prop Hot Water Heat AT35 102696-04 (CTE-5104) None Cooling with Marning Warmup AT36 102696-01 (CTE-5101) 103065-01 (Duct Thermistor) Cooling with Morning Warmup* AT36-1 102696-01 (CTE-5101) 101618-01 (2 Pole Relay) * Requires External Signal Inlet Size cfm Range D G H L M W 6 0-500 5 7/8 7 3/8 8 15 1/2 3 3/8 12 8 0-900 7 7/8 7 3/8 10 15 1/2 3 3/8 12 10 0-1400 9 7/8 5 3/8 12 1/2 15 1/2 3 3/8 14 12 0-2000 11 7/8 5 3/8 15 15 1/2 3 3/8 16 14 0-3000 13 7/8 5 3/8 17 1/2 15 1/2 3 3/8 20 16 0-4000 15 7/8 5 3/8 18 15 1/2 3 3/8 24 8
Standard Features Aerocross Flow Sensor Titus II Controller Pneumatic Actuator Multiple Control Strategies 1/2 2lb Density Liner 22 Gauge Housing Right Hand Configuration Optional Features Water Coils (Page 11) Thermostat (Page 11) SteriLoc Liner (Rigid Foil Faced) Standard Optional Control Strategy Control Code Controller Thermostat Restrictor Tee High Pressure Selector Hot Water Valve Cooling Only DA/NO 00 Titus II CTC.1001-10 (DA) HFO-0010 ------------------------ DA/NC 00 Titus II CTC.1001-10 (DA) HFO-0010 ------------------------ RA/NO 00 Titus II CTC.1002-10 (RA) HFO-0010 ------------------------ RA/NC 00 Titus II CTC.1002-10 (RA) HFO-0010 ------------------------ Cooling (Hot Water Reheat) DA/NO 00 Titus II CTC.1001-10 (DA) HFO-0010 ------------------------ Normally Open DA/NC 00 Titus II CTC.1001-10 (DA) HFO-0010 ------------------------ Normally Open RA/NO 00 Titus II CTC.1002-10 (RA) HFO-0010 ------------------------ Normally Closed RA/NC 00 Titus II CTC.1002-10 (RA) HFO-0010 ------------------------ Normally Closed Cooliong (Electric Reheat) DA/NO 00 Titus II CTC.1001-10 (DA) HFO-0010 ------------------------ DA/NC 00 Titus II CTC.1001-10 (DA) HFO-0010 ------------------------ RA/NO 00 Titus II CTC.1002-10 (RA) HFO-0010 ------------------------ RA/NC 00 Titus II CTC.1002-10 (RA) HFO-0010 ------------------------ Cooling (Morning Warmup- Remote Signal) DA/NO 00 Titus II CTC.1001-10 (DA) HFO-0010 RCC-1008 DA/NC 00 Titus II CTC.1001-10 (DA) HFO-0010 RCC-1008 RA = Reverse Acting DA= Direct Acting NO= Normally Open NC=Normally Closed Inlet Size cfm Range D G H L M W 6 0-500 5 7/8 7 3/8 8 15 1/2 3 3/8 12 8 0-900 7 7/8 7 3/8 10 15 1/2 3 3/8 12 10 0-1400 9 7/8 5 3/8 12 1/2 15 1/2 3 3/8 14 12 0-2000 11 7/8 5 3/8 15 15 1/2 3 3/8 16 14 0-3000 13 7/8 5 3/8 17 1/2 15 1/2 3 3/8 20 16 0-4000 15 7/8 5 3/8 18 15 1/2 3 3/8 24 9
Standard Features Standard Box: without controls Aerocross Flow Sensor Control Enclosure (Field Mounted Controls) 1/2 2lb Density Liner 22 Gauge Housing Right Hand Configuration Optional Features Water Coils (Page 11) SteriLoc Liner (Rigid Foil Faced) TDI /ASI Digital Controls (Page 12) Optional Titus Control Strategies Control Strategy Control Code (Personality) Controller Standard Wall Sensor Cooling Only 1 ASIC/1-8055 WS-001 VAV w/ 1 Stage Electric ReHeat 2 ASIC/1-8055 WS-001 2 3 ASIC/1-8055 WS-001 3 4 ASIC/1-8055 WS-001 VAV w/ Hot Water ReHeat 5 ASIC/1-8055 WS-001 Additional Digital Components (Page 13) Inlet Size cfm Range D G H L M W 6 0-500 5 7/8 7 3/8 8 15 1/2 3 3/8 12 8 0-900 7 7/8 7 3/8 10 15 1/2 3 3/8 12 10 0-1400 9 7/8 5 3/8 12 1/2 15 1/2 3 3/8 14 12 0-2000 11 7/8 5 3/8 15 15 1/2 3 3/8 16 14 0-3000 13 7/8 5 3/8 17 1/2 15 1/2 3 3/8 20 16 0-4000 15 7/8 5 3/8 18 15 1/2 3 3/8 24 10
1/2 O.D. copper tubes, 0.016 thick wall Aluminum plate fins, 10 per inch 20 Gauge galvanized steel casing Copper male solder connections Connection is slip and drive to duct work down stream of terminal Leak tested to 300 PSIG Max working pressure: 240 PSIG Max 200 degree F water Model VAV Box Inlet Size Rows Height (H) Width (W) Length (L) A B C D WC-SD1 6 1 8 12 5 3 6 1/4 0 1/2 WC-SD1 8 1 10 12 5 3 8 3/4 0 1/2 WC-SD1 10 1 12 1/2 14 5 4 1/4 10 7/8 1 1/4 7/8 WC-SD1 12 1 15 16 5 4 1/4 13 3/8 1 1/4 7/8 WC-SD1 14 1 17 1/2 20 7 1/2 4 1/4 15 7/8 1 1/4 7/8 WC-SD1 16 1 18 24 7 1/2 4 1/4 15 7/8 1 1/4 7/8 WC-SD2 6 2 8 12 5 4 1/4 6 7/8 0 7/8 WC-SD2 8 2 10 12 5 4 1/4 9 1 1/8 7/8 WC-SD2 10 2 12 1/2 14 5 4 1/4 11 1/2 1 1/8 7/8 WC-SD2 12 2 15 16 5 4 1/4 14 1 1/8 7/8 WC-SD2 14 2 17 1/2 20 7 1/2 4 1/4 16 1/2 1 1/8 7/8 WC-SD2 16 2 18 24 7 1/2 4 1/4 16 1/2 1 1/8 7/8 Designed for Proportional Control of Value & Damper Actuators Throttling Range is Factory set to 3 F but is Field Adjustable up to 12 F Dirct & Reverse Acting Models available External Restrictor required on Single Pipe Models Available Options Include Vertical Scale Plates, C Scale Plates and Metal Covers Model Description Action Set Point Range Color Restrictor Tee Drywall Mounting Kit 2 x 4 Almond Back Plate (For Mounting in 2 x 4 Electric Box) CTC-1611 One Pipe Pneumatic Direct Acting 55 F-85 F Almond HFO-0010 HMO-0023 HMO-5024 CTC-1612 One Pipe Pneumatic Reverse Acting 55 F-85 F Almond HFO-0010 HMO-0023 HMO-5024 CTC-1621 Two Pipe Pneumatic Direct Acting 55 F-85 F Almond --------- HMO-0023 HMO-5024 CTC-1622 Two Pipe Pneumatic Reverse Acting 55 F-85 F Almond --------- HMO-0023 HMO-5024 11
ASIC/2-8040 Configurable System Controllers ASIC/2-7040 Model Universal Inputs Binary Relay Outputs Analog Outputs Binary Triac Outputs 10 Year Hardware Clock ASIC/2-7040 16 12 8 --------------------- Yes ASIC/2-8040 8 3 4 5 Yes Pre-Programmed Packaged AC Controller ASIC/1-8655 Model Sequences Binary Relay Outputs Analog Outputs Additional Standard Features ASIC/1-8655 1 & 2 Stage Heat Pumps 1 & 2 Stage Air Conditioner 8 2 0-10 Vdc Modulating Economized CO2 Demand Ventilation Auxilary Heating/Cooling Lighting Control Variable Air Volume Controller ASIC/1-8055 Model Sequences Binary Triac Outputs ASIC/1-8055 Cooling Only Hot Water or Electric Heat Intermittant or Constant Fan Dual Duct 8 8 On Board Universal Binary/ Analog Inputs Air Flow Sensor Additional Standard Features Auto-Changeover Lighting Control Variable User Adjust After Hours Override ASI Controls Accessories Model Description Functionality SINC/1-1030 Portable System Interface Provides communication between a PC or laptop and the ASI Network SINC/3-3000 Multi-Port System Interface Provides communication between a host computer/modem and the ASI Network Etherlink TCP/IP System Interface Provides communication between a host computer and the ASI Network via a corperate LAN or WAN using TCP/IP ASI Expert Configuration Software Windows based graphical configuration software 12
Downblast Centrifugal Exhaust Ventilator Roof Mounted Optional Damper (Page 14) Optional Roof Curb (Page 14) Optional Fan Speed Control (Page 117) Optional Disconnect (Page 14) ACED Direct Drive ACEB Belt Drive Less Motor and Drive Fans will be Set to your CFM, Horsepower, and Voltage Specifications Specications Capacity (CFM) Size A B C G T Sq. Roof Opening Mtr HP @ 1/8 SP @ 1/4 SP @ 3/8 SP @ 1/2 SP 70ACEB 2 7/8 23 9/16 21 1/8 2 18 13 1/2 x 13 1/2 1/6, 1/4 96-402 70-379 63-356 95-331 80ACEB 2 7/8 23 9/16 21 1/8 2 18 13 1/2 x 13 1/2 1/6, 1/4 221-842 102-750 356-704 394-650 100 ACEB 2 7/8 23 9/16 21 1/8 2 18 13 1/2 x 13 1/2 1/6, 1/4 293-1093 497-1050 564-1011 389-973 120ACEB 1 13/16 28 7/16 26 7/8 2 20 15 1/2 x 15 1/2 1/6, 1/4, 1/3 709-1729 515-1668 720-1606 937-1541 135ACEB 2 3/16 28 7/16 27 1/4 2 20 15 1/2 x 15 1/2 1/6, 1/4, 1/3, 1/2 1128-2330 983-2258 640-2184 960-2108 150ACEB 3 1/16 32 7/8 28 7/8 2 24 19 1/2 x 19 1/2 1/6, 1/4, 1/3, 1/2, 3/4 1460-3096 1288-3014 1024-2930 1224-2844 165ACEB 3 9/16 32 7/8 29 3/8 2 24 19 1/2 x 19 1/2 1/6, 1/4, 1/3, 1/2, 3/4 1682-3504 1464-3397 1356-3288 1525-3175 180ACEB 3 15/16 37 11/16 34 1/2 3 30 25 1/2 x 25 1/2 1/6, 1/4, 1/3, 1/2, 3/4, 1, 1-1/2, 2 2123-5419 1875-5326 1539-5229 1759-5131 Specications Capacities Size A B C G T Sq. Roof Opening Mtr HP @ 1/8 SP @ 1/4 SP @ 3/8 SP @ 1/2 SP 70C10DH 1 3/4 13 5/8 13 13/16 2 18 13 1/2 x 13 1/2 1/25 121 --- --- --- 70C15DH 1 3/4 13 5/8 13 13/16 2 18 13 1/2 x 13 1/2 1/20 249 194 135 --- 90C10DH 2 1/2 18 3/4 16 13/16 2 18 13 1/2 x 13 1/2 1/25 417 232 --- --- 90C15DH 2 1/2 18 3/4 16 13/16 2 18 13 1/2 x 13 1/2 1/8 758 649 509 411 100C10DH 2 1/2 18 3/4 16 13/16 2 18 13 1/2 x 13 1/2 1/25 510 354 191 --- 100C15DH 2 1/2 18 3/4 16 13/16 2 18 13 1/2 x 13 1/2 1/8 855 766 667 552 13
Extruded Aluminum Frame, Aluminum Blades and Hinge Pins w/ Brass Bushings For Use with ACED and ACEB Model ACE Units Size BD-12 60 70 80 90 100 11 3/4 x 11 3/4 BD-14 120 135 13 3/4 x 13 3/4 BD-18 150 165 17 3/4 x 17 3/4 BD-24 180 195 210 225 245 23 3/4 x 23 3/4 Treated Wood Nailer Continuously Welded Corners 18 Gauge Galvanized Steel 1 1/2-3lbs Density Thermal and Acoustical Insulation 13 1/2 High Size AC Unit Sizes Roof Opening 16 60 70 80 90 100 13 1/2 18 120 135 15 1/2 22 150 165 19 1/2 28 180 195 210 225 245 25 1/2 34 270 300 31 1/2 40 330 365 37 1/2 Damper shelf Shipped Loose for Field Mounting Certifications: UL/CSA Commercial Grade, Heavy Duty Model Type *Vendor * Vendor Model Voltage Phase Capacity Range Enclosure Disc 115-1/2 Single Pole Toggle Leviton CS115-2 115 1 Up Thru 1/2 HP 2 x 4 Galvanized Handy Box Disc 115-3/4 Single Pole Toggle Carling Switch 2GA94-73 115 1 3/4 HP 2 x 4 Galvanized Handy Box Disc 115-1/2 Single Pole Toggle Leviton 1222-S 115 1 1 HP 2 x 4 Galvanized Handy Box Disc 230-1 Single Pole Toggle Carling Switch 2GA94-73 208-230 1 Up Thru 1 HP 2 x 4 Galvanized Handy Box Disc 480-2 Three Pole Toggle Carling Switch HK274-73 208-480 3 Up Thru 2 HP 4 x 4 Galvanized Handy Box or equivalent from another manufacturer 14
Centrifugal Exhaust Fan Direct Drive Ceiling Mounted Plastic Frame Provided Optional Accessories Roof Cap/Relief Vent (Page 16) Roof Jack (Page 16) Wall Cap (Page 17) Fan Speed Control (Page 17) Gemini Isolator Kit (Page 18) Brick Vent (Page 18) Used in Clean Air Exhaust Applications requiring Capacity Ranges of 50 to 251 CFM Static Pressure Capacity Ranges from free air -.875 in. of WG Uses Single Speed Motors Easily Converted from Ceiling to Inline by Installing a Single Panel in Place of Grille and Removing Back Plate Capacities Model Max Watts/ BHP RPM A B @ 0 SP @ 1/8 SP @ 1/4 SP @ 1/2 SP GC-120 35 1200 13 1/4 14 3/4 92 74 50 --- GC-140 70 1500 13 1/4 14 3/4 110 109 109 106 GC-160 113 1500 13 1/4 14 3/4 154 168 173 166 GC-180 192 1500 13 1/4 14 3/4 253 249 245 235 Centrifugal Exhaust Fan Direct Drive Ceiling Mounted Used in Clean Air Exhaust Applications requiring Capacity Ranges 74 to 852 CFM (GC220-740) 680-1807 CFM (GC-820-960) Optional Accessories Roof Cap/Relief Vent (Page 16) Roof Jack (Page 16) Wall Cap (Page 17) Fan Speed Control (Page 17) Gemini Isolator Kit (Page 18) Brick Vent (Page 18) Static Pressure Capacity Ranges from free air -.875 in. of WG (GC220-740) free air -.625 in. of WG (GC-820-960) Uses One or Two Speed Motors (GC220-740) Three Speed Motor (GC-820-960) Easily Convertible from Ceiling to Inline by Relocating One Panel Single Scroll Fan (GC220-740) or Double Scroll Fan (GC-820-960) Housing Outlet Steel Grille Capacities Model Max Watts/ BHP RPM L W H A B J K @ 0 SP @ 1/8 SP @ 1/4 SP @ 1/2 SP GC-220 41 1050 12 3/8 9 3/4 9 3/4 8 6 12 5/16 9 11/16 120 104 73 --- GC-320 75 1365 12 3/8 10 3/4 10 3/4 8 6 12 5/16 10 11/16 217 202 182 --- GC-420 170 1145 17 11 7/8 11 7/8 8 6 16 15/16 11 15/16 327 287 260 202 GC-520 172 1205 17 11 7/8 11 7/8 8 6 16 15/16 11 15/16 356 344 332 301 GC-620 233 960 17 11 7/8 11 7/8 10 1/2 4 3/4 16 15/16 11 15/16 451 428 400 297 GC-720 301 1375 17 11 7/8 11 7/8 10 1/2 4 3/4 16 15/16 11 15/16 709 682 653 578 GC-820 287/.162 780 27 14 11/16 14 11/16 20 6 27 14 1/2 944 925 904 830 GC-920 430/.282 925 31 14 11/16 14 11/16 24 1/4 6 31 14 1/2 1471 1415 1356 1190 15
Flat Plate Base Continuously Welded Corners All Aluminum Construction 1 1/2-3lbs Density Thernal and Acoustical Insulation Anti-backdraft Flange Birdscreen Curb Cap Base Gravity Application Temperature Difference 10 10 20 20 Wind Speed 5 10 5 10 Stack Height 10 20 30 40 10 20 30 40 10 20 30 40 10 20 30 40 Size Throat CFM CFM CFM CFM 8 0.394 96 104 111 118 178 182 187 191 104 118 131 143 182 191 200 208 Exhaust Application Pressure Drop (in WG) Size Throat 0.050 0.100 0.125 0.150 0.200 0.250 0.300 0.375 0.500 CFM 8 0.394 212 299 334 366 423 473 518 579 669 Model Gemini Units Throat Dia. Type PR8 120-520 8 19/32 Curb Mount PR8F 120-520 8 19/32 Flat Base Corrosion Resistant Galvanized Steel Black Baked Enamel Finish 1/2 Birdscreen Round Throat (RJR100) or Rectangle (RJ200) 14 1/2 x 18 3/4 Base 6 1/2 Tall Model Gemini Units Throat Size RJR100 120-180 6 Dia RJ200 220-520 10 1/4 X 10 3/4 16
WCG WCG are Galvanized Steel WCG have 1/2 Birdscreen Corrosion Resistant Model Gemini Units A Sq B C Dia D WCG-2 220-520 10 5/16 7 3/16 6 3/8 8 5/16 WCG-6 620-740 12 13/16 6 5 10 13/16 WCG-8 820-860 22 5/16 7 3/16 6 3/16 20 5/16 WCG-9 920-960 26 9/16 7 15/16 6 15/16 24 9/16 WCR WCR (round w/ damper) are Aluminum Model Gemini Units A Sq B C Dia D E WCR6 120-340 8 7 6 8 1/2 12 3/4 WCR8 220-520 10 9 8 8 1/2 14 1/4 Available 5 AMP (GC 100-800) and 10 AMP (GC 900) Available only on 115V and 230V Shaded Pole or Permanent Split Capacitor Motors Allows operation of AC Units from 100% of capacity to 50% Excellent Energy Conservation and Lower Sound Levels when 100% operation is not needed Available only on 115V and 230V shaded pole or permanent split capacitor motors Not available on 1140 RPM and 1725 RPM motors 17
Used for Gemini ceiling and inline units 120-740 Bushings are made of resilient thermoplastic Bushing and eyelets are sized to be used with common 1/4 X 20 tpi all thread Standard Gemini brackets easily accomadate isolator bushings Flanged nuts eliminate the need for additional washers and provide simplified field assembly Model Fits Gemini Series A BV1 120-180 4 3/4 BV5 520-720 7 3/4.100 minimum wall thickness Frame depth is 4 1/8 mortar ribs on top and bottom of frame (adds 1/4 to nominal height) Blades: 6063T5 extruded aluminum, 45 angles, overlap for optimum visual screening 18 x 16 mesh aluminum insect screen Actual Size, not Undersized Grease capture and containment system to Prevent Accumulation on the roof Attaches to Lowest Point on Fan Biodegradable UV Protected Non Woven Fibers Retrofit Kits Available 18
Model Size Frame Depth CFDR3.5 6 6 1/2 CFDR3.5 8 6 1/2 CFDR3.5 10 6 1/2 CFDR2 12 8 1/2 CFDR2 14 8 1/2 CFDR2 16 11 1/2 20 gage galvanized steel blades UL Classified insulation (as required) 20 gage galvanized steel frame Mill Finish Actual Size to fit over Diffuser Neck 20 gage galvanized steel blades UL Classified insulation (as required) 20 gage galvanized steel frame Model Size Frame Depth CFD2 22 x 22 3 Mill Finish Actual Size to fit over Diffuser Neck Thermal Blanket Also in 3 extension piece Size 24 x 24 Neck to be Field Cut 19
UL555 1-1/2 Hour Rated Classified Curtain Type Fire Damper Galvanized steel construction Frame: 20 gage galvanized steel channel Blades: 24 gage galvanized curtain type in air stream Closure Springs: 301 stainless steel constant force type Fusible Link: 165 (standard) Both Horizontal and Vertical Mounting Dampers fabricated approximately 1/4 less than given duct size Nominal Duct Size 6 x 6 16 x 10 8 x 6 18 x 10 10 x 6 24 x 10 12 x 6 12 x 12 8 x 8 14 x 12 10 x 8 16 x 12 12 x 8 18 x 12 14 x 8 20 x 12 16 x 8 24 x 12 10 x 10 14 x 14 12 x 10 16 x 16 14 x 10 24 x 24 Nominal Duct Size 6 x 6 16 x 10 8 x 6 18 x 10 10 x 6 24 x 10 12 x 6 12 x 12 8 x 8 14 x 12 10 x 8 16 x 12 12 x 8 18 x 12 14 x 8 20 x 12 16 x 8 24 x 12 10 x 10 14 x 14 12 x 10 16 x 16 14 x 10 24 x 24 UL555 Classified 1-1/2 Hour Rated Static Curtain Type Fire Damper Integral 12, 20 gage galvanized steel sleeve Includes 1-1/2 Fast Angle, one side Galvanized steel construction Frame: 20 gage galvanized steel channel Blades: 24 gage galvanized curtain type in air stream Closure Springs: 301 stainless steel constant force type Fusible Link: 165 (standard) Both Horizontal and Vertical Mounting Dampers fabricated approximately 1/4 less than given duct size D = Nominal Duct Size Width = D + 2 H = Height 6 8 8 3/4 8 10 10 3/4 10 12 12 3/4 12 14 15 3/4 14 16 17 3/4 16 18 19 3/4 UL555 1-1/2 Hour Rated Classified Curtain Type Fire Damper Sealed round transitions for medium pressure systems Galvanized steel construction Frame: 20 gage galvanized steel channel Blades: 24 gage galvanized curtain type out of air stream Closure Springs: 301 stainless steel constant force type Fusible Link: 165 (standard) Both Horizontal and Vertical Mounting Dampers fabricated approximately 1/8 less than given duct size UL555 Classified 1-1/2 Hour Rated Static Curtain Type Fire Damper Sealed round transitions for medium pressure systems Integral 12, 20 gage galvanized steel sleeve Includes 1-1/2 Fast Angle, one side Galvanized steel construction Frame: 20 gage galvanized steel channel Blades: 24 gage galvanized curtain type out of air stream Closure Springs: 301 stainless steel constant force type Fusible Link: 165 (standard) Both Horizontal and Vertical Mounting Dampers fabricated approximately 1/8 less than given duct size D = Nominal Duct Size Width = D + 2 H = Height 6 8 8 3/4 8 10 10 3/4 10 12 12 3/4 12 14 15 3/4 14 16 17 3/4 16 18 19 3/4 20
16 gage galvanized steel door Synthetic knob with threaded metal inserts 1/2 x 3/8 neoprene gasket Mill galvanized finish Duct Size Diameter Hole Size Door Size 6 7 x 3 8 x 4 8 7 x 3 8 x 4 10 11 x 7 12 x 8 12 11 x 7 12 x 8 14 11 x 7 12 x 8 16 11 x 7 12 x 8 18 11 x 7 12 x 8 20 11 x 7 12 x 8 24 15 x 11 16 x 12 28 15 x 11 16 x 12 32 15 x 11 16 x 12 36 15 x 11 16 x 12 SMACNA Standard Access Doors Removable Double Cam Fastening Double Skin Door 2 cam locks (16 & under) 4 cam locks (over 16 ) SMACNA Standard: Water Pressure Through 12 x 12 : 3 wg Above 12 x 12 : 2 wg Size (w x h) 6 x 6 8 x 8 10 x 10 12 x 12 14 x 14 16 x 16 18 x 18 24 x 24 1 (25) fiberglass insulation SMACNA Standard Access Doors Hinged (Continuous Piano Type) Double Skin Door 1 cam locks (16 & under) 2 cam locks (over 16 ) SMACNA Standard: Water Pressure Through 12 x 12 : 3 wg Above 12 x 12 : 2 wg Size (w x h) 6 x 6 8 x 8 10 x 10 12 x 12 14 x 14 16 x 16 18 x 18 24 x 24 1 (25) fiberglass insulation Foam Gasket Seals 21
Diameter 14 16 18 20 22 24 26 28 30 32 45 elbow 3 gore standing seam Gore locked and internally sealed Single-wall galvanized Centerline Radius = 1.5 x Diameter 90 elbow 5 gore standing seam Gore locked and internally sealed Single-wall galvanized Centerline Radius = 1.5 x Diameter Diameter 14 16 18 20 22 24 26 28 30 32 Diameter 4 5 6 7 8 9 10 12 45 elbow Die Stamped Continuously stitch welded Rolled Edges Single-wall galvanized Centerline Radius = 1.5 x Diameter 90 elbow Die Stamped Continuously stitch welded Rolled Edges Single-wall galvanized Centerline Radius = 1.5 x Diameter Diameter 3 4 5 6 7 8 9 10 12 22
Die Stamped Concentric Reducer Single-wall galvanized d 1 d 2 L (length) 5 4 7/8 6 4 1 1/4 6 5 3/4 7 5 1 1/2 7 6 1 8 4 2 1/4 8 5 1 5/8 8 6 1 1/4 8 7 3/4 10 6 2 1/4 10 8 1 1/8 10 9 5/8 12 8 2 1/8 * Fabricated. Others Die Stamped Fabricated Concentric Reducer Single-wall galvanized d 1 d 2 L (length) 12 5 10 1/4 12 6 8 7/8 14 6 12 1/8 16 6 14 3/8 18 10 11 5/8 18 12 8 7/8 18 14 6 1/8 18 16 3 5/8 20 10 14 1/4 20 12 11 1/2 20 14 8 3/4 20 16 6 1/4 20 18 3 3/4 22 12 15 1/4 22 14 12 1/2 22 16 10 22 18 7 1/4 22 20 4 3/8 24 14 14 1/8 d 1 d 2 L (length) 24 16 11 1/2 24 18 8 7/8 24 20 6 24 22 3 1/4 26 18 10 5/8 26 20 8 26 22 5 26 24 3 7/8 28 18 15 3/8 28 22 9 7/8 28 24 7 1/8 28 26 4 3/8 30 20 14 3/4 30 24 12 30 26 9 1/4 30 28 6 5/8 32 22 14 1/8 32 24 11 3/8 32 28 6 1/8 23
Die Stamped Saddle Tap Radiused Entry Single-wall galvanized Fits Duct Size D = Branch Dia 4 4 6 4 8/7 4 8/7 6 10 5 10 10 10/9 4 10/9 6 10/9 8 12 6 12 8 12 10 12 12 14 10 14 12 14 14 16 12 16 14 16 16 16/14 4 16/14 8 18 14 Fits Duct Size D = Branch Dia 18 18 18/14 6 20 14 20 18 20 20 20/16 10 20/18 8 20/18 16 22 14 22 18 22 20 22 22 22/18 12 24 12 24 14 24 18 24 20 24 22 24 24 24/18 12 24/22 8 24/22 10 24/22 16 45 Degree Fabricated Lateral Saddle Tap Single-wall galvanized Fits Duct Size D = Branch Dia 4 4 6 4 6 8 4 6 8 10 6 8 10 12 5 6 8 10 12 14 5 6 8 10 12 14 16 6 8 10 12 14 16 18 6 8 10 12 14 16 18 20 6 8 10 12 14 16 18 22 6 8 10 12 14 16 18 20 24 6 8 10 12 14 16 18 20 22 24
Assembled Tee With Fabricated or Die Stamped PSU Single-wall Galvanized d 1 d 2 L H 4 4 6 2 5/8 6 6 9 4 1/8 8 8 11 5 10 10 13 3/4 6 12 12 15 3/8 7 1/8 14 14 19 8 16 16 22 1/2 8 7/8 18 18 24 1/2 9 7/8 20 20 26 1/2 10 7/8 22 22 28 1/2 12 7/8 24 24 30 1/2 12 7/8 Used for Joining Fittings (Fitting to Fitting Coupling) Single-wall Galvanized Diameter Length 3 3 5/8 4 3 5/8 5 3 5/8 6 3 5/8 7 3 5/8 8 3 5/8 9 3 5/8 10 5 1/8 12 5 1/8 14 5 1/8 16 6 5/8 18 6 5/8 20 6 5/8 22 6 3/4 24 6 3/4 26 6 3/4 28 8 5/8 30 8 5/8 32 8 5/8 Used for Joining Spiral Ducts Single-wall Galvanized Diameter Length 3 3/8 4 3/8 5 3/8 6 3/8 7 3/8 8 3/8 9 3/8 10 3/8 12 3/8 14 3/8 16 3/8 18 3/8 20 3/8 22 1/2 24 1/2 26 1/2 28 5/8 30 5/8 32 5/8 25
End Cap for Spiral Duct Single-wall galvanized Diameter Length 3* 3/8 4 3/8 5 3/8 6 3/8 7 3/8 8 3/8 10 3/8 12 3/8 14* 3/8 16* 3/8 18* 3/8 20* 3/8 22* 1/2 24* 1/2 26* 1/2 28* 5/8 30* 5/8 32* 5/8 * Fabricated. Others Die Stamped Radiused Bellmouth Take-off To be installed on flat side i.e. rectangular duct or plenum Single-wall galvanized Diameter Length = radius 4 5/8 5 3/4 6 7/8 7 1 8 1 9 1 10 1 12 1 14 1 16 1 Take-off/ Starting Collar To be installed on flat side i.e. rectangular duct or plenum Single-wall galvanized Diameter 18 20 22 24 26 28 30 32 26
Balancing Damper For use in systems where a complete shutoff of air flow is not required Gasketed, shaft-mounted load bearing bushings Integral shaft-blade assembly 2 sheet metal insulation stand-off Locking blade quadrant w/ damper position indicator Gasketed shaft penetrations to minimize leakage Full fitting body assembly with bead stop Single-wall galvanized Diameter 4 5 6 8 9 10 12 14 16 18 20 22 24 26 28 30 32 Register Only Supply/ Return register Adjustable Double Deflection Blades Volume Damper designed specifically for direct mounting on spiral duct Rectangular reigster taps are not required for installation Galvanized Steel Length 13 x 3 13 x 6 17 x 3 17 x 6 17 x 9 21 x 3 21 x 6 21 x 9 25 x 3 25 x 6 33 x 3 33 x 6 33 x 9 41 x 6 49 x 3 49 x 6 49 x 9 Spiral lockseam duct Flat seam Evenly spaced integral seam locking feature Double corrugations on all SPIROduct 14 diameter and larger Single-wall galvanized Stocked in 10 lengths Diameter 3 4 5 6 7 8 9 10 11 12 14 16 18 20 22 24 26 28 30 32 27
Stocked in 25 ft lengths Strong Poylester film laminated and encapsulating a heavy corrosion resistant steel wire helix Wire helix suppoorts a thick blanket of fiberglass insulation over a fiberglass scrim Outer vapor barrier is durable black polyethylene Smooth air tight innercore of polyester is designed for low-medium pressure systems UL 181 listed Class 1 Air Duct Diameter 4 5 6 7 8 9 10 12 14 16 Pressure Rating (WG) Positive: 10 in (4-16 ID) 6 in (18-20 ID) Negative:1 in (4-16 ID) 1/2 in (14-20 ) Velocity: 5000 FPM Temp Range: -20 F - 250 F continuous R Value: R-4.2 Stocked in 25 ft lengths Strong Poylester film laminated and encapsulating a heavy corrosion resistant steel wire helix Wire helix suppoorts a thick blanket of fiberglass insulation over a fiberglass scrim Bi-directional reinforced metalized vapor barrier which will not unravel Smooth air tight innercore of polyester is designed for low-medium pressure systems UL 181 listed Class 1 Air Duct Diameter 4 5 6 7 8 9 10 12 14 16 Pressure Rating (WG) Positive: 10 in (4-16 ID) 6 in (18-20 ID) Negative:1 in (4-16 ID) 1/2 in (14-20 ) Velocity: 5000 FPM Temp Range: -20 F - 250 F continuous R Value: R-4.2 Pressure Rating (WG) Positive: 16 in (4-11 ID) 10 in (12-16 ID) Negative:2 in (4-16 ID) Velocity: 6000 FPM Temp Range: -20 F - 250 F continuous R Value: R-4.2 Diameter 4 5 6 7 8 9 10 12 14 16 18 20 Stocked in 25 ft lengths Strong woven fiberglass fabric, with flame resistent coating and permanently bonded to a coated steel wire helix Wire helix suppoorts a thick blanket of insulation and provides a double air seal Bi-directional reinforced metalized vapor barrier which will not unravel High pressure flexible duct for use in low-high pressure heating and cooling systems UL 181 listed Class 1 Air Duct The first Greenguard Certified flexible duct in HVAC history 28
Pressure Rating (WG) Positive: 10 in (2-14 ID) Negative:1 in (2-14 ID) Velocity: 5000 FPM Temp Range: -20 F - 250 F continuous Diameter 3 4 5 6 7 8 9 10 12 14 Stocked in 25 ft lengths Non-insulated air connector Strong woven fiberglass fabric, with flame retardant coating, permanently bonded to a corrosion resistant steel wire helix For use in low-medium pressure heating and cooling systems (alternative in applications where insulated duct is not required or cannot be used) UL 181 listed Air Duct Connector Pressure Rating (WG) Positive: 16 in (2-10 ID) 10 in (12-20 ID) Negative:1 in (2-20 ID) Velocity: 6000 FPM Temp Range: -20 F - 250 F continuous Diameter 16 18 20 Stocked in 15 ft lengths Non-insulated Class 1 flexible air duct Strong woven fiberglass cloth fabric, with permanently bonded to a corrosion resistant coated spring steel wire helix For use in low-high pressure heating and cooling systems (alternative in applications where insulated duct is not required or cannot be used) UL 181 listed Class 1 Air Duct Snaplock Stainless steel band Cadmium plated Hex head bolt to attach Thermaflex to metal fittings Fits Flexduct 8 12 29
14 gauge steel frame and door panel Standard for the industry Provides a 100% clear opening with superior strength, rigidity, and true squareness Door panel is mounted to the frame on concealed spring hinges that open to 175 degrees for complete access without allowing the door to impact the wall Door Size Opening No. Cams 8 x 8 8 1/4 x 8 1/4 1 10 x 10 10 1/4 x 10 1/4 1 12 x 12 12 1/4 x 12 1/4 1 14 x 14 14 1/4 x 14 1/4 1 16 x 16 16 1/4 x 16 1/4 1 18 x 18 18 1/4 x 18 1/4 1 24 x 24 24 1/4 x 24 1/4 4 14 gauge frame 20 gauge door panel 2 mineral fiber insulation between inner and outdoor panel Fire-Rated - carries the UL 1 1/2 hour class B fire rating Door Size Wall/Ceiling Opening Locks 12 x 12 12 3/8 x 12 3/8 1 16 x 16 16 3/8 x 16 3/8 1 18 x 18 18 3/8 x 18 3/8 1 24 x 24 24 3/8 x 24 3/8 1 Continuous type, steel hinge with stainless steel pin Self latching lock An adhesive coated gasket that hold the fitting securely in position during installation and assures a tight seal 1 wide flange allows for easy installation 45 angle design allows for optimum air flow A = Diameter B C D Cut Hole 7 11 1/2 9 1/4 13 7 x 10 8 11 1/2 10 1/4 14 8 x 11 9 11 1/2 11 1/4 15 9 x 12 10 11 1/2 12 15 10 x 12 12 11 1/2 14 17 12 x 14 14 11 1/2 16 19 14 x 16 30
Used for making round take off connections to rectangular sheet metal duct locking grove is die formed and notched for easy installation Damper is assembled using a spring loaded retractable bearing and positive locking hardware Diameter Length Cut Hole Gauge 4 5 3/4 3 7/8 2 6 5 5 3/4 4 7/8 2 6 6 5 3/4 5 7/8 2 6 7 5 3/4 6 7/8 2 6 8 7 1/2 7 7/8 2 6 9 7 1/2 8 7/8 2 6 10 9 1/2 9 7/8 2 6 12 9 1/2 11 7/8 2 6 14 13 5/8 13 7/8 2 4 16 13 5/8 15 7/8 2 4 18 17 5/8 17 7/8 2 4 20 17 5/8 19 7/8 2 4 Double Quadrant on sizes 8 or Larger On inch flanged turn out, adding rigidity to the collar Double-faced gasket applied to the flange guarantees a tight seal Self-sealing Takeoff - Peel, stick and fasten with sheet metal screws Diameter Overall Length Gauge 6 5 1/2 26 8 5 1/2 26 10 5 1/2 26 12 7 26 14 11 24 16 13 1/2 24 18 18 24 20 18 24 Double Quadrant on sizes 8 or Larger 28 gauge galvanized steel Riveted construction 3 high square with 2 1/2 high collar Square Dimensions Diameter 6 x 6 6 8 x 8 6 8 x 8 8 9 x 9 6 9 x 9 8 10 x 10 8 10 x 10 10 12 x 12 8 12 x 12 10 12 x 12 12 15 x 15 12 15 x 15 14 18 x 18 14 18 x 18 16 18 x 18 18 31
Achor AC57 is the first UL-Listed HVAC Cloth Duct Tape for Flexible Duct Printed Cloth Tape AC57 Polyethylene Coated with Scientifically Designed Adhesive to meet the stringent requirements of the HVAC contractor 2 Inches Wide Tensile strength of 50.7 lbs per inch width of tape Holds 100g load w/o slipping for 24 hours in a shear adhesion test after exposure of 150 F for 60 days Resitance to flame spread and smoke generation Resistance to mold growth and humidity Resistance to the effects of high temperatures (shows no advers affects after exposure of 212 F for 60 days) AC45 For Applications where High Shear and Low Residue Characteristics are desired 48 MM Wide www.intertapepolymer.com Model Size Color UL Rating AC45S 2 x 60 yrds Silver UL 181 B AC57B 2 x 60 yrds Black UL 181 B-FX Gripple Self-locking Wire Rope Grip Model Size Cable Length HF0205 HF0210 HF0215 HF0230 HF0305 HF0310 HF0315 HF0330 No.2 Working Load Limit 100 lbs LOOP SYTLE No.2 Working Load Limit 200 lbs LOOP SYTLE 5 ft 10 ft 15 ft 30 ft 5 ft 10 ft 15 ft 30 ft The strength of high tensile steel cable All ferrules are made from aluminum All No. 1 and 2 are pull tested to twice the working load limit ALSO NOTE: Non-standard lengths manufactured and quoted on request Toggle and Stud Styles are available with a two weeks lead time CORNERS AND CABLE CUTTERS ARE ALSO STOCKED UL Listed 32
Produced with high quality nylon 6/6 Angled Tail features finger grips and a stay-tab for easy handling --allows the tie to be partially closed without engaging the pawl The one piece design, transition rails and teeth provide a low insertion force while maintaining a high tensile strength UL 181B-C Rated for Air Handling Spaces Complies with New & Future Builiding Codes Meets Air Diffusion Council Installation Instruction Insures consistent material, smooth edges and 0% mold growth Model Color Length Width Thickness Tie Tensile Diameter Per Bag AL-48-175-8-L Gray 48.5.340.090 175 lbs 14.5 50 AL-36-175-9-L Natural/White 37.1.340.090 175 lbs 11 50 Heavy Duty Tension Tool 120lb to 175lb Duct Straps Manual Tension Control Neatly cuts off Straps Metal Construction Used for making round take off connections to rectangular sheet metal duct locking grove is die formed and notched for easy installation Damper is assembled using a spring loaded retractable bearing and positive locking hardware 33
General Ventilation Air Quality Method CFM = People x Outdoor Air Requirments (CFM/Person) where People = Occupancy x Floor Area (ft 2 ) 1000 Air Change Method BLDG Volume (ft 3 ) CFM = Air Change Frequency Heat Removal Method CFM = Space btu Heat Removal Hr 1.10 x Temp Diff Suggested Air Quality Outdoor Air Required (CFM/person) Occupancy (people/1000 sq ft) Auditoriums 15 150 Ballrooms/Discos 25 100 Bars 30 100 Beauty Shops 25 25 Classrooms 15 50 Conference Rooms 20 50 Correctional Facility Cells 20 20 Dormitory Sleeping Rooms 15 20 Dry Cleaners 30 30 Gambling Casinos 30 120 Game Rooms 25 70 Hardware Stores 15 8 Hospital Operating Rooms 30 20 Hospital Patient Rooms 25 10 Laboratories 20 30 Libraries 15 20 Medical Procedure Rooms 15 20 Office Spaces 20 7 Pharmacies 15 20 Photo Studios 15 10 Physical Therapy 15 20 Resturant Dining Areas 20 70 Retail Facilities 15 20 Smoking Lounges 60 70 Sporting Spectator Areas 15 150 Supermarkets 15 8 Theaters 15 150 Circle Formulas π d A = 4 C = π d 2 Where: A = Area C = Circumference d = diameter Suggested Air Changes Type of Space Air Change Frequency(mins) Assembly Halls 3-10 Auditoriums 4-15 Bakeries 1-3 Boiler Rooms 2-4 Bowling Alleys 2-8 Dry Cleaners 1-5 Engine Rooms 1-1.5 Factories 1-5 Forges 1-2 Foundries 1-4 Garages 2-10 Generating Rooms 2-5 Glass Plants 1-2 Gymnasiums 2-10 Heat Treat Rooms 0.5-1 Kitchens 1-3 Laundries 2-5 Locker Rooms 2-5 Machine Shops 3-5 Mills (Paper) 2-3 Mills (Textile) 5-15 Packing Houses 2-15 Recreation Rooms 2-8 Residences 2-5 Resturants 5-10 Retail Stores 3-10 Shops (General) 3-10 Theaters 3-8 Toilets 2-5 Transformer Rooms 1-5 Turbine Rooms 2-6 Warehouses 2-10 Duct Design Typical Design Velocities for HVAC Components Intake Louvers Velocity (FPM) 7000 CFM and Greater 400 Exhaust Louvers 5000 CFM and Greater 500 Filters - Pleated Low Efficiency 350 Medium Efficiency 500 High Efficiency 500 HEPA 250 Common Formulas Electrical Ohm s Law Volts Ohms = Amperes R = E I Amperes = Volts Ohms I = E R Volts = Amperes x Ohms E = IR A-C Circuit 746 x ( Horsepower) Three Phase Amperes = 1. 732 x Volts x Eff x Power Factor Single Phase Amperes = DC Circuits Watts = Volts x Amperes Amps = Watts I = w Volts E HP = Fan Laws CFM CFM 1 2 Volts x Amperes x Eff 746 RPM1 SP1 RPM1 = = RPM2 SP2 RPM2 V Belt Length Formula 2 ( D d) L= 2c+ 1. 57( D+ d) + 4c where L = Pitch Length of Belt c = Center Distance of Sheaves D = Picth Diameter of Large Sheave d = Pitch Diameter of Small Sheave Full Load Current Single Phase Motor HP 115V 200V 230V 1/6 4.4 2.5 2.2 1/4 5.8 3.3 2.9 1/3 7.2 4.1 3.6 1/2 9.8 5.6 4.9 3/4 13.8 7.9 6.9 1 16 9.2 8 1 1/2 20 11.5 10 2 24 13.8 12 3 34 19.6 17 5 56 32.2 28 7 1/2 80 46 40 10 100 57.5 50 ( ) ( ) ( ) 746 x ( Horsepower) ( Volts ) x ( Eff ) x ( Power Factor) w = EI 2 HP HP 1 2 RPM1 = RPM2 Motor and Drive Basics Full Load Current Three Phase Motor HP 115V 200V 230V 460V 575V 2300V 4000V 1/2 4 2.3 2 1.8 3/4 5.6 3.2 2.8 1.4 1.1 1 7.2 4.15 3.6 1.8 1.4 1 1/2 10.4 6 5.2 2.6 2.1 2 13.6 7.8 6.8 3.4 2.7 3 11 9.6 4.8 3.9 5 17.5 15.2 7.6 6.1 7 1/2 25 22 11 9 10 32 28 14 11 15 48 42 21 17 20 62 54 27 22 25 78 68 34 27 30 92 80 40 32 40 120 104 52 41 50 150 130 65 52 60 177 154 77 62 15.4 8.8 75 221 192 96 77 19.2 11 100 285 248 124 99 24.8 14.3 125 358 312 156 125 31.2 18 150 415 360 180 144 36 20.7 200 550 480 240 192 48 27.6 Over 200 HP Approx. Amps/HP 2.75 2.4 1.2.96.24.14 3
CFM.01.02.03.04.06.08.1.2.3.4.6.8 1 2 3 4 6 8 10 100,000 80,000 60,000 40,000 30,000 20,000 10,000 8,000 6,000 4,000 3,000 2,000 1,000 800 600 400 300 200 100 80 60 40 30 20 1200 7 6 80 9 8 70 60 55 50 45 40 36 30 32 24 2628 22 20 18 14 12 10 4 5 1400 1600 1800 In. Duct Diameter 200 2000 2200 Fpm Velocity 2400 2600 300 2800 3000 3200 3600 400 4000 500 10.01.02.03.04.06.08 1.2.3.4.6.8 1 2 3 4 6 8 10 4500 Fpm Velocity Friction in Inches of Water per 100 Feet Friction of Air in Straight Duct 5000 600 5500 6000 700 6500 7000 7500 8000 9000 10 000 In. Duct Diameter 800 900 1000 1200 12 000 1400 1600 32 26 2830 24 22 20 14 12 10 9 8 7 6 4 2 18 5 3 1-1/2 1800 Multiply Area By To Obtain acres x 4047.0 = Square meters acres x.4047 = Hectares acres x 43560.0 = Square feet acres x 4840.0 = Square yards circular mils x 7.854x10-7 = Square inches circular mils x.7854 = Square mils hectares x 2.471 = Acres hectares x 1.076 x 10 5 = Square feet square centimeters x.155 = Square inches square feet x 144.0 = Square inches square feet x.0929 = Square meters square inches x 6.452 = Square cm. square meters x 1.196 = Square yards square meters x 2.471 x 10-4 = Acres square miles x 640.0 = Acres square mils x 1.273 = Circular mils square yards x.8361 = Square meters Multiply Length By To Obtain centimeters x.3937 = Inches fathoms x 6.0 = Feet feet x 12.0 = Inches feet x.3048 = Meters inches x 2.54 = Centimeters kilometers x.6214 = Miles meters x 3.281 = Feet meters x 39.37 = Inches meters x 1.094 = Yards miles x 5280.0 = Feet miles x 1.609 = Kilometers rods x 5.5 = Yards yards x.9144 = Meters
Visit Us Welcome to Langendorf Supply Co., Inc