TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System



Similar documents
Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

T-100-R Installation Guide

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

UNDERFLOOR HEATING SYSTEMS DETAILS AND NOTES

A guide to becoming an Installer of Choice

Heating Controller. Building Technologies HVAC Products

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Wireless Thermostats 230v and Battery Operated Instruction Manual

Mode Switch. Fan Switch Menu button Program button

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

A Class Air Source Heat Pump User Guide

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

Digital timer thermosatat. isense. Installation and Service Manual AG

Heating and Hot Water Services Controls General Technical Specification

HEAT PUMP PROGRAMMABLE THERMOSTAT

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Installation Guide for Hive Active Heating

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

HERZ-Thermal Actuators

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

How To Set The Sensor On A Powerpoint 3.5 (Powerpoint) On A Blackberry 2.5A (Powerplant) On An Iphone Or Ipad (Powerplant) On The Blackberry 3.2 (

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Smile. The All-In-One Heating Controller

Electric Flow Boiler

ELECTRIC CENTRAL HEATING FLOW BOILER

RF 1. Contents: Connecting diagram. Detailed information:

Uponor Smatrix Wave PLUS R-167 INSTALLATION AND OPERATION MANUAL HELP AND TUTORIAL

Thermostat with display

Overview - Danfoss Link and living software versions

HCE80/HCC80/HCE80R/HCC80R

HEAT HEAT COOL HEAT PUMP COOL

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Nest Learning Thermostat Installation Guide. Installation step-by-step

Air Source Heat Pump Installation and Maintenance Manual

T5000 T000 LCD Digital Fan Coil Thermostat

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Drayton Digistat +2RF/+3RF

Table of Contents. 1 - Specifications Installation Wiring User controls...7

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

Floor Heating Warehouse.co.uk

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Homeowner Quick Start Guide. Version 2

F453. TiF453. User guide 10/11-01 PC

User Manual THR840DUK Digital Thermostat

Sales Bulletin #CT016a

it500 Internet Thermostat INSTALLER MANUAL

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Drayton Digistat +2RF

Aerona Air Source Heat Pumps

EK908FHL - Thermostat for floor heating

WHITE-RODGERS COMFORT-SET 90 SERIES

RRV934. Multi-controller. Synco living

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

User's Guide. Pinless Moisture Meter. Model MO257

Fully Pumped Systems

Features of your Air to water heat pump

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

For installation guide see reverse of book

Variable Air Volume - VAV

Install Guide 3M-50. Caution. Caution

Digital 2 Channel Time Clock EFFECTIVE: 1ST APRIL User Guide PB2CTC

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

USB-500 Series Stand-Alone, Low-Cost Data Loggers

evohome Wireless Radiator Zoning Kit Installation & User Guide

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Installer guide. Release 2.2

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Using Building Energy Management Systems (BEMS) Best Practice for Energy and Carbon Savings.

User Guide ecobee ecobee 250 University Ave Suite 400 Toronto Ontario M5H 3E5 Canada Toll free

Professional Contractor INSTALLATION GUIDE

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Nest Learning Thermostat Pro installation & configuration guide

Install Guide CT101. Caution. Caution

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE

SMART COMFORT & EASY EFFICIENCY HEATING CONTROLS

Electronic Control Devices The European Product Catalogue 2007

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

How To Control A Thermostat

Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T

Transcription:

TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling

TICS - Mid Range System Mid Range System

TICS Mid Range Install controls without the complicated wiring Application UFH Radiator DHW Scheduled Central Control Or Sensor Type 4.3 Touch Screen cc245 7 Touch Screen cc200 Bus Network Bus Network Star Network Digital (2 Ch) Bus Network And /Or Bead (2 Ch) Bus Network And /Or Plate (1 Ch) Star Network Complete Integration The system can interface with underfloor heating, radiators and hot water to ensure ideal comfort condition at minimum running cost.

TICS Mid Range Central Control: The control s design enables all elements of the underfloor heating, Radiators and hot water to be managed centrally via a simple to use Touch Screen Interface. Total Flexibility At the console select Zone Type Underfloor Heating Radiators Select any Sensor Type Digital (2 Ch) Bus Network Bead (2 Ch) Bus Network Plate (1 Ch) Star Network Hot Water Mix and match to suit your application System will automatically assign the zones numbering Energy Efficient: Time and temperature control for each zone, combined with auto optimisation capabilities, which automatically learns the thermal inertia of each zone, including hot water hysteresis. This system results in high comfort levels and impressive energy savings capabilities. Reliability All control devices are individually tested prior to despatch which dramatically reduces failure rates and consequently improves on-site product reliability. User Friendly Time, effort and expertise have been invested to develop an intuitive, easy-to-use, touch screen interface which enables the end user centrally control of the all elements of the system at the touch of a key.

TICS Reliability Reliability 100% Product Function Testing Reliability All control devices are individually tested prior to despatch which dramatically reduces failure rates and consequently improves on-site product reliability. Extensive Diagnostics Embedded diagnostic facilities quickly identify typical installation and service issues. Pump Exercising Routine Ensure pumps are kept operational during periods of inactivity. 12v Operation No Batteries - No Replacing, No Recurring Cost, No Leaking No RF issues - 100% reliability All products are CE approved Health & Safety Significantly reduces the amount of 220v cable installed thought out the building

TICS Simple To Operate Central Console Touch Screen Console Simple user friendly icons Room Sensors 3 Button Warmer Cooler Override User Friendly Time, effort and expertise have been invested to develop an intuitive, easy-touse, sensor and touch screen interface Zone Labelling Zone designations are clearly labelled. View Room Settings Enables the user to view and edit every zone setting. Stop Facility Ideal for rooms which are not in use. Lockout Disable zone sensor buttons. Control at your finger tips

TICS Energy Efficient Mid Range & Advance System See Module Options 32 Zones individual Temperature & Scheduling Individual time & temperature control of each zone. Boost Heat Take advantage of low cost energy tariff periods. Hot Water Management Time & Temperature, Hysteresis & Legionella Boost functions Zone Settings Set back Tracking ensure heat-up time are not over stretched Outstanding Energy efficient features

TICS Comfort Features Zone Temperature Independent temperature control per zone E.g. Bedrooms 20 C, Baby Bedroom 24 C. Programmable Timer Individual zone scheduling to homeowner personal settings. Hot Water Boost HW boost activates the DHW for 2 hours. Optimisation Optimisation is a mechanism that ensures zone temperatures are reached at the scheduled times, including an automatic learning mode. Frost Protection The system protects against frost even when a zone is not in use.

TICS - Total Integrated Control Strategy TICS: Mid Range - Home Owner Central Control: All elements of the heating, & hot water managed Up to 32 zones All rooms can be managed individually to reduce running costs. Touch Screen 4.3 - CC245 Time & Temperature Control Temp (SP/SB/BH) / Timer 7 day inc 4 x SP per day Simple To operate Typical user operations require one or two keystrokes. Edit Zone Labeling Zone label edit capability Relay Board R10i8s2 4 Modes All Off / All On / Manual / Timed. Holiday Select dates of an upcoming Holiday. Sensor Lock Out Ability to disable the use of room sensor button. View Room Settings View & edit each room setting./ View all zones status Sensor Options Digital (2 Ch) (Bus) Bead (2 Ch) (Bus) Plate (1 Ch) (Star) Hot Water Boost Scheduling / Boost / Hysteresis /Legionella Purge Whole House Status View status of all zones at a glance. Optimization 4 Setting including an automatic learning mode. The control s design enables all elements of the underfloor heating, radiators and hot water to be managed centrally via a simple to use Touch Screen Interface.

TICS: Mid Range - Integration Console Central Control of all elements (UFH / Rad / DHW) Zoning Individual Time & Temperature Control via Discrete Plate Sensors or Digital Sensors Hot Water Time & Temperature Control via Cylinder Stat Simple Setup Mechanical Manage all Actuators /Valves /Pump/Boiler Demand. Schedule Schedule element such as Garden Sprinklers

TICS: Time & Cycling Relays Timers Individually Assigned Time ON Delays (1-99 Min) Individually Assigned Time Off Overrun (1-99 Min) Solves noise issues Pump Exercising Routine Assign Cycle Interval (Hrs) e.g. 336 (2 weeks) Assign Cycle Duration (1-30 Min) Solves noise issues

TICS - Installation Cabling 1 st Fix 1 st Fix Cabling (Sensors) All Low Voltage Plates - Star (2 wire) Digital - Bus (4 wire) Cabling Single cable bus network design reduces installation time and costs. Reduce electrical cost approx 50%-60% No Containment Duct or Conduits 12v safer for the end user

TICS - Installation Cabling 2 nd Fix TICS manages all interlocks!!! Traditional Controls TICS Controls Install controls without the complicated wiring 2 nd Fix Cabling (Mechanical) Single Point wiring Manage all Zone Valves, Pump & Boiler Demand. Impressive M&E Savings System manages interlock!!! Time Delay & Pump Exercising Configurable Time On Delay, Overrun & Pump Exercising Simple No on site complex wiring No Phone Calls Eliminate electrical phone calls No Interlock Wiring

TICS : Commissioning Mid Range Configurable (R10i8 Board) Tailored Tailor the system to suit project requirements Sensors: Digital (2Ch)/ Bead (2Ch)/ Plate (1Ch) Manage: UFH/ Rad/ DHW/ Scheduled (Lights, sprinklers etc) Control: All Pumps, Valve & Boiler Demands Effortless Commissioning Pump Aufh (All UFH zones) Pump MF (Only UFH this MF) Easy Drop-Down List Selection Pump Ht (UFH & Rad) Pump DHW (All DHW zone) Pump Rad (All Rad zones) Boiler (UFH/Rads/DHW) Controls built to suit a changing world

TICS - Total Integrated Control Strategy TICS: Mid Range - Optional Modules Optional Modules Touch Screen 4.3 - CC245 M M M M M M Remote Access Broadband Router with Wifi Required (Hardware & Software) DHW Priority Automatically override heating zones Basic Cooling (R8) Override Boiler & active a single whole house cooling device Extend Drop Down List Extend Install Basic Installation / Commissioning Drop Down List Input config - Modes System Mode Inputs-Trigger Seasons & Master Modes) Alarms Via Inputs Display -Front Screen System Options O O O Touch Screen 4.3 or 7 Options & 8/16/24/32 Zones Sensors Digital (2ch) (Bus )(Dual) /Bead (2ch) (Bus) (Dual) /Plate (1ch) (Star) Screed Screed Max & Min override Select which Module and System Options suit your project requirements

TICS - Total Integrated Control Strategy Sample Layout 1 Equipment 4.3 Touch Screen Digital Sensors (2ch) (Air & Screed Probe or Dual Zone) Bus Wiring Bead Sensors (2ch) (Air & Screed Probe or Dual Zone) Bus Wiring DHW Probe

TICS - Total Integrated Control Strategy Sample Layout 2 Equipment 4.3 Touch Screen Plate Sensors DHW Probe (1ch) (Air ) Star Wiring

TICS - Total Integrated Control Strategy Sample Layout 3 Equipment 4.3 Touch Screen Digital Sensors (2ch) (Air & Screed Probe or Dual Zone) Bus Wiring Bead Sensors (2ch) (Air & Screed Probe or Dual Zone) Bus Wiring Plate Sensor (1ch) (Air ) Star Wiring DHW Probe

TICS - Total Integrated Control Strategy Sample Layout 5 Equipment 7 Touch Screen Digital Sensors (2ch) (Air & Screed Probe or Dual Zone) Bus Wiring Bead Sensors (2ch) (Air & Screed Probe or Dual Zone) Bus Wiring Plate Sensor (1ch) (Air & Screed Probe or Dual Zone) Star Wiring DHW Probe

Central Control: The control s design enables all elements of the heating, and hot water managed centrally via a simple to use Touch Screen Interface. 32 zones All rooms can be managed individually to reduce running costs. Temperature Control Individual Set Point on each zone Set Point & Set Back 7 Day Programmable Timer Individual Timer for each Zone. Simple To operate Typical user operations require one or two keystrokes. Edit Zone Labeling Zone label edit capability TICS 4.3 Touch Screen CC245 Whole House Status View status of all zones at a glance. Copy Schedule Helpful copy function between zones. Edit Zone Labeling Zone label edit capability Optimization 4 Setting including an automatic learning mode. Time change Summer /Winter automatic change over. 4 Modes All Off / All On / Manual / Timed. Holiday Select dates of an upcoming holidays. Sensor Lock Out Ability to disable the use of room sensor button. View Room Settings Enables the user to view and edit each room setting. Hot Water Boost The HW key turns the Immersion on for 2 hours. Hysteresis Stop Boiler Cycling Legionella DHW 70 C 1/2hr Scheduled Boost Legibility 4.3 inch Touch Screen 480*272 pixels Property Value Excellent controls - property resale value increases. Environment Efficient Control Technology results in reduced gas emissions. that harm the environment.

TICS Sensors Types/ Finishes Digital Slim Line 2 Channel 4 Wire Bus Network Colour: White Model: CCT764WHI Colour: Brushed Stainless Steel Model: CCT764BSS Colour: Mirrored Chrome Model: CCT764MC Bead Sensor 2 Channel 4 Wire Bus Network Colour: Legrand Special Model: CCB765 Legrand Colour: Brushed Stainless Steel Model: CCB765BSS Colour: Mirrored Chrome Model: CCT765MC Colour: Legrand Special Model: CCB765 Legrand Plate Sensor 1 Channel 2 Wire Star Network Colour: White (ABS) Model: CCP767WHI) Colour: Brushed Stainless Steel Model: CCB767BSS Colour: Mirrored Chrome Model: CCB767MC

Zone Sensors SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use. BH - Boost heat Utilize low cost electricity. 7 day & 5/2 Programmable Timer * Independent Temperature control for each Zone E.g. Bed Rooms 20 C, Baby Bed Room 24 C. PI - Optimization* Optimization is a mechanism of ensuring zone temperatures are achieved according to the programmed schedule. Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time. Stop Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back. Lockout* Solves the problem of children interfering with the room temp or thermostats located public areas. Frost Protection Mode - Disable * Ensure all plumbing is protected against frost. Floor surface Protection * Max floor temps setting, ensures floor surface are protected. Min Screed Temp: Floor Surface Warming * Ideal for wet rooms, where occupant wishes to step onto a warm floor even if the air temp has been satisfied. TICS Digital Sensor CC764 Features Screen Screen: LCD Displays Actual & Set Point Temp Backlight : Blue Backlight with timeout. Calibration Calibration and address functions (Via Console) Calibration Ch 1 & Ch 2 Central Override at the Console * All sensor can be centrally overridden by the main console. Centralized Clock No need to enter date & time on each thermostat. Installation Simple to install, significantly reduce electrical costs. 12v Operation Low voltage for Heath & Safety issues. No Batteries Eliminates dying & replacing old batteries No RF issues- 100% reliability. Set Back Tracking Ensure the Set Back always follows the Set Point. Network All sensors are network capable. Dual Sensing channels All sensors are capable accurately measuring both the air and an auxiliary probe. Ideal to set a maximum safety limit for screed temperatures. Aux (Type 01) Configurable Aux Channel External / Flow / Retune / Ref Temp Dual Zone (Type 02) Single Digital sensor with Probe, can manage 2 zones Accuracy Accuracy of 0.5 C * Centrally set & control led at the console

TICS Bead Sensor CC765 Features Calibration Calibration and address functions (Via Console) Calibration Ch 1 & Ch 2 Zone Sensors SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use. BH - Boost heat Utilize low cost electricity. 7 day & 5/2 Programmable Timer * Independent Temperature control for each Zone E.g. Bed Rooms 20 C, Baby Bed Room 24 C. PI - Optimization* Optimization is a mechanism of ensuring zone temperatures are achieved according to the programmed schedule. Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time. Stop Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back. Frost Protection Mode - Disable * Ensure all plumbing is protected against frost. Floor surface Protection * Max floor temps setting, ensures floor surface are protected. Min Screed Temp: Floor Surface Warming * Ideal for wet rooms, where occupant wishes to step onto a warm floor even if the air temp has been satisfied. Accuracy Accuracy of 0.5 C Central Override at the Console * All sensor can be centrally overridden by the main console. Centralized Clock No need to enter date & time on each thermostat. Installation Simple to install, significantly reduce electrical costs. 12v Operation Low voltage for Heath & Safety issues. No Batteries Eliminates dying & replacing old batteries No RF issues- 100% reliability. Set Back Tracking Ensure the Set Back always follows the Set Point. Network All sensors are network capable. Dual Sensing channels All sensors are capable accurately measuring both the air and an auxiliary probe. Ideal to set a maximum safety limit for screed temperatures. Aux (Type 01) Configurable Aux Channel External / Flow / Retune / Ref Temp Dual Zone (Type 02) Single Digital sensor with Probe, can manage 2 zones * Centrally set & control led at the console Model: CCP765WHI CCP765MC CCP765BSS Colour: MK White (ABS) Mirrored Chrome Brushed Stainless Steel

TICS Plate Sensor CC767 Wiring 2 Wire Star Network 12v Operation Low voltage for Heath & Safety issues. No Batteries Eliminates replacing old batteries No RF issues- 100% reliability. Installation Simple to install, significantly reduce electrical costs. Accuracy Accuracy of 1 C Model: CCP767WHI CCP767MC CCP767BSS Colour: White (ABS) Mirrored Chrome Brushed Stainless Steel * Central control via the console * Central Override at the Console * All sensor can be centrally overridden by the main console. * Zone Sensors SP - Set Point Ambient Room Temp. SB - Set Back Room not in Use. BH Boost heat Utilize low cost electricity. * 7 day & 5/2 Programmable Timer * Independent Temperature control for each Zone E.g. Bed Rooms 20 C, Baby Bed Room 24 C. * PI - Optimization Optimization is a mechanism of ensuring zone temperatures are achieved according to the programmed schedule. Auto: This setting will self-learn the thermal inertia of the room and adjust the start time from memory to deliver the required temperature at the scheduled time. * Stop Ideal for rooms which are not in use. Ignores timer schedule, moves to Set Back. * Frost Protection Mode - Disable * Ensure all plumbing is protected against frost. * Set Back Tracking Ensure the Set Back always follows the Set Point. *

TICS Wiring Centre I/O Model: R10/i8 OUTPUTS Outputs (R10) 8 x 230v Powered Outputs Zones 1 x 230v Powered Outputs Manifold Pump 1 x S/L Output Boiler (Switch live output can be jumpered to serve as a powered output) Led indication Each relay has a LED indicating the output status at a glance Terminals 3 Connector terminals per relay. (A single relay can activate up to 3 actuators) Fuse Rate Relay 1-5 (Qty 1) 4Amp Relay 6-8 & ufh pump (Qty 1) 4Amp Relay 6 Boiler (Qty 1) 4Amp 230v Input Supply (Qty 1) 1Amp Slow Blow INPUTS Inputs Temperature Input 1-8 2 wire Temperature Input Operate with temp probe OR mechanical cylinder stat Interface with Thimble or Plate Sensors BUS NETWORK Network Terminal Bus network Connection ABGV Network with Console & Digital Sensors Bus network Connection ABG Network between I/O boards Max Network Overall Cable length 1200meter Addressing Dip switch address Up to 8 boards can be connected in a system Configurable: Tailored to suit your project SUMMARY Reduce Electrical Installation Error & Cost Centralised All connections in one location Reduce Wiring Single drop connect each device Powered Individually Powered Outputs Termination All connection via screw terminal Layout Clear & accessible layout Diagnostics View Comms Status Switch Input Qty 2 Use with Optional Modules e.g. Back Boiler SUPPLY Supply Single 220v spur required at I/O Module Fuse Rating : 1Amp Slow Blow