Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.



Similar documents
ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

Understanding Arc Flash

Part 1 System Modeling & Studies for Existing Systems

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

What s up with Arc Flash?

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

misconceptions about arc-flash hazard assessments

Arc Flash Energy Mitigation Techniques

A Guide to Performing An Arc Flash Hazard Assessment Using Power Analysis Software

How to reduce exposure to arc flash hazards

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

Introduction to Arc Flash

Analyzing Electrical Hazards in the Workplace

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Technical Guide. SKM Arc Flash Line Side vs. Load Side

2012 NFPA 70E. Ten Most Important Changes. John A. DeDad

2008 Eaton Corporation. All rights reserved.

Choosing the Best Solution for Reducing Arc Energy

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

The following components are common to most cubicles; this example is an ABB HK cubicle.

PRESENTED AT THE 2011 IEEE IAS PULP & PAPER INDUSTRY TECHNICAL CONFERENCE, NASHVILLE, TN: IEEE PERSONAL USE OF THIS MATERIAL IS PERMITTED.

Safety By Design. Strategies for Electrical Contractors

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc.

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

Roadmap to Compliance with NFPA 70E Arc Flash Requirements

Arc Flash Mitigation & Selective Co-ordination

2013WWOA Conference Technical Conference Program

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

! WARNING Arc Flash and Shock Hazard Appropriate PPE Required

INTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010

A Survey of Arc Flash Computation Methods and Mitigation Strategies By Dr. Carl J. Spezia

The Three A s of Arc Flash

4160: THE GREEN 480 MEDIUM VOLTAGE ELECTRICAL SYSTEMS

A USERS GUIDE TO ARC RESISTANT LOW VOLTAGE SWITCHGEAR & MOTOR CONTROL ANALYTICAL COMPARISON VS ARC FLASH TEST RESULTS

90.2(A) Covered & 90.2(B) Not Covered 6/23/2015. Learning Objectives. 90.2(A) Covered & 90.2(B) Not Covered. Change Summary

Implementation of arc flash mitigating solutions at industrial manufacturing facilities

ELECTRICAL SAFETY RISK ASSESSMENT

Demystifying arc flash hazard management

Electrical Distribution Services for Mining and Metals Industries

MEDIUM VOLTAGE. Michael Mosman, PE. CCG Facilities Integration Incorporated FACILITIES INTEGRATION INCORPORATED

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

NFPA 70E Updates Affect Your Most Valuable Assets

Low Voltage Switchgear

SAFE ELECTRICAL WORK PRACTICES & 2015 NFPA 70E

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

The Other Hazard of Electricity. Larren Elliott Ph.D. Lindsay Polic, CSP, REHS

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Electrical Safety in the Marine Environment

Electrical Safety in the Workplace

OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Enhancing Personnel Safety with Arc Resistant Equipment

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

ELECTRICAL & ARC FLASH SAFETY PROGRAM

Replacement Breakers & Retrofit Products

Midwest Healthcare Engineering Conference and Trade Show 2012 Indianapolis, Indiana

Arc Flash Mitigation. Executive summary. by Antony Parsons, Ph.D., P.E.

ARC FLASH HAZARD MITIGATION. Industrial Tests, Inc. [indtests.com]

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Low Voltage Circuit Breakers. Arc flash hazards

Bypass transfer switch mechanisms

Procedure Number Arc Flash Hazard Calculation and Required Protection Revision 5. TVA Safety Procedure Page 1 of

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Written Program ELECTRICAL SAFETY. Based on OSHA Subpart S and NFPA 70E Standards

Automation & Power World Improving safety Through arc resistant switchgear and arc reducing components. ABB Wednesday, 23 March 2011 Slide 1

UL Validated Testing of Arc-Resistant Motor Control Centers

100% Rule Alternate Method Arc Blast Arc Flash Approved Approved Equipment Authority Having Jurisdiction (AHJ) Authorized Work Bare Hand Work

Session Eleven: Development of Standards for MV Switchgear Rated for Arc Protection

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

Power-Zone 4 Arc Resistant Low Voltage Switchgear

OSHA Published First-Ever Arc Flash Protection Requirements for the Electric Power Industry Significant changes and unprecedented compliance

Electrical Safety Program

Arc Flash Safety in 400V Data Centers

Campus Safety Procedure Electrical Safety

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

ETAP Arc Flash Analysis

THE reliability, cost, and safety of electricity and industrial

3053 Electrical Safety Training Program Course Outline

How to Build a Safe and Effective Electrical Maintenance Program

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ARC Flash Boundary & NFPA-70E Requirements PPE Program

PROCEDURES FOR SAFE WORKING AND TESTING OF ENERGIZED ELECTRICAL EQUIPMENT

Hyperlinks are Inactive

Test Before Touch Easier Said Than Done. Ken Crawford, DuPont Kent Haggerty, Dupont

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Common Sense and Knowledge Approach to Electrical Safety

Progress in Impacting Policy in Workplace Electrical Safety

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Fusible Disconnect Switch

Fault Characteristics in Electrical Equipment

Design of electrical power system for a 1000MW nuclear power generating station

Medium voltage VCP-W MR2 (integral racking)

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Transcription:

Arc Flash Mitigation Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Distance is Safety We will discuss through examples of actual occurrences and possible scenarios the inherent dangers and best possible procedures for using Remote Racking/Switching and to mitigate damage during an arc flash or limit the occurrence. If procedures require the operation or racking of switchgear while energized these techniques and safety tools will limit exposure to arc flash and other dangers.

Arc Flash Basics An arc flash is measured is calories per cm 2. This value is referred to as the Incident Energy (E I ) Current industry standards require workers to wear PPE with a rating (ATPV) > than the E I This is a 480V arc flash set up in a cubic box to simulate an MCC bucket or breaker cell by PSE&G E I for this test was 51 cal/cm 2

Arc Flash Hazard There is no possible way to completely avoid arc flash hazards The preferred method for any electrical work is to de-energize the equipment you will be working on, in order to do this the equipment must be switched off, this action is considered an Arc flash hazard

Arc Flash Hazard 2009 NFPA 70E Definition: Arc Flash Hazard A dangerous condition associated with the possible release of energy caused by an electric arc FPN #1 An arc flash hazard may exist when energized electrical conductors or circuit parts are exposed or when they are within equipment in a guarded or enclosed condition, provided a person is interacting with the equipment in such a manner that could cause an electric arc.. FPN #2 See table 130.7 (C)(9) for examples of activities that could pose an arc flash hazard

2009 NFPA 70E Tables Task 2004 70E HRC 2009 70E HRC Insertion or removal (Racking) of CB s from cubicles, doors open (600V class switchgear) 3 4 Insertion or removal (Racking) of CB s from cubicles, doors closed (600V class switchgear) 2 4 Insertion or removal (Racking) of CB s from cubicles, doors open (Metal clad switchgear 1kV-38kV) Insertion or removal (Racking) of CB s from cubicles, doors closed (Metal clad switchgear 1kV-38kV) 4 4 2 4

NFPA 70E Tables Many companies decide to use the tables for PPE selection to save money and avoid doing an analysis. The tables can only be used if the available fault current and clearing times are known for the equipment to be worked on. The tables assume a maximum amp-cycle value. If these limits are not met an arc flash analysis is required. Example: 600V rated switchgear Note 4: Maximum of 35kA available short circuit current available, maximum of up to 30 cycle clearing time

Table Limitations Typical MV/LV substation Fuses on MV side will not react quickly to secondary fault Due to coordination issues the Main breaker usually does not employ INST trip ST delays can be 0.3 seconds or longer Arc Flash reduction switches or Maintenance switches can be effective

NFPA eq. B - 5.2 E Flash MB = 1038.7 x D Hazard Analysis -1.4738 B x t A x (.0093 x F 2 -.3453 x F + 5.9675) E MB = maximum 20 in. cubic box incident energy ANSWER 10.3220 cal/cm 2 NFPA eq. B- 2-1 B- 2-2 B-2-3.2 D B = distance from arc electrodes, inches (for distances 18 in. and greater) t B = arc duration, seconds (cycles / 60 cycles) F = bolted fault short circuit current, in ka (for the range of 16 to 50kA) Arc Flash Protection (bolted fault) Boundary MVA bf = bolted fault MVA at point involved V = volts % Z = percent impedance based on transformer MVA t = time of arc exposure in seconds, (cycles / 60 cycles) I SC = {{[MVA Base x 10 6 ] / [1.732 x V]} x 100 / % Z} 18 0.1 40 2 480 5 2 I SC = Short Circuit Current ANSWER 48,114 Amps P = 1.732 x V x I sc 10-6 x 0.707 2 P = Maximum Power (in MW) in a 3-phase arc 19.994 D c = [ 2.65 x MVA bf x t ] 1/2 D c = Curable Burn Distance ANSWER 14.56 Ft D c = Curable Burn Distance ANSWER ANSWER 174.72 inches seconds ka MVA volts % Z seconds MW inches Excel program using NFPA 70E Equations Example: 2000kVA 480V transformer 2 second clearing time Arc Flash Protection (transformer) Boundary NFPA eq. B-2-3.3 MVA = rating of transformer 2 MVA V % t = Z time volts = percent of arc exposure impedance in based seconds, transformer (cycles / 60 MVA cycles) 2 volts % seconds Z IP SC = = 1.732 Short x Circuit V x I 10 Current x 0.707 2 ANSWER Amps D c = [ 53 x MVA x t ] 1/2 D c = Curable Burn Distance ANSWER 14.56 Ft D c = Curable Burn Distance ANSWER 174.72 inches D C =14.56 ft

Flash Protection boundary The flash protection boundary determines at what distance from exposed live parts flash protection must be worn Distance is usually based on not exceeding 1.2 cal/cm 2 of heat energy on a persons skin 1.2 cal/cm 2 will cause a 2 nd degree burn of exposed skin in 0.1 second

Flash Hazard Analysis THE INFORMATION IS PROVIDED WITH NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. NO USE SHOULD BE MADE OF THE INFORMATION EXCEPT BY FULLY QUALIFIED PROFESSIONALS HAVING FORMED THEIR OWN EVALUATION OF THE INFORMATION FOR THEIR OWN PURPOSES AND APPLICATIONS. INFORMATION BASED ON NFPA 70E. (SS Ver. 13) NFPA eq. B - 5.1 Equation for Arc in Open Air D A = distance from arc electrodes, inches (for distances 18 in. and greater) t A = arc duration, seconds (cycles / 60 cycles) F = bolted fault short circuit current, in ka (for the range of 16 to 50kA) E MA = 5271 x D A -1.9593 x t A x (0.0016 x F 2-0.0076 x F + 0.8938) 36 2 48 39.673 inches seconds E MA = maximum open arc incident energy ANSWER cal/cm 2 ka A 48 ka fault with a 2 second clearing time at 36 E I will be: NFPA eq. B - 5.2 Equation for Arc in a Cubic Box D B = distance from arc electrodes, inches (for distances 18 in. and greater) t B = arc duration, seconds (cycles / 60 cycles) F = bolted fault short circuit current, in ka (for the range of 16 to 50kA) E MB = 1038.7 x D -1.4738 B x t A x (.0093 x F 2 -.3453 x F + 5.9675) E MB = maximum 20 in. cubic box incident energy ANSWER 36 2 48 114.3091 inches seconds ka cal/cm 2 39 Cal/cm 2 in open air 114 Cal/cm 2 in a cubic box Arc Flash Protection (bolted fault) Boundary NFPA eq. MVA bf = bolted fault MVA at point involved V = volts 3 480 MVA volts

PPE Limitations No way to re-test or verify the ATPV rating Expensive to purchase and maintain Little protection from arc blast pressures, not recommended for >40cal/cm 2 exposure Cumbersome, vision and mobility is limited

Mitigation Arc resistant switchgear is available that redirects the arc away from the operator using a system of channels and flaps Existing switchgear may also be modified to be arc resistant Must meet the requirements of IEEE C37.20.7

Mitigation 2 basic concepts for arc flash mitigation: Reduce the total amp-cycles of the arcing fault Increase the distance from the arc to the worker Limiting fault current seems to be a simple solution Keep in mind that reducing the fault current may increase the clearing time of the OCPD and may actually increase the hazard Current limiting fuses are only effective if the arcing current is in the current limiting range

Validity of Arc Flash Analysis The results of the arc flash analysis, or the HRC from the tables assume the OCPD will clear the fault within the manufactures published TCC A failed OCPD, or even a slow one, will result in higher Incident Energies than the workers PPE is rated for New 2009 70E Article 205.3 General Maintenance Requirements OCPD s shall be maintained IAW the manufactures instructions or industry standards FPN: Refer to NFPA 70B or ANSI/NETA MTS for guidance on maintenance frequency, methods, and tests

Validity of Arc Flash Analysis Over 30% of low and medium voltage power circuit breakers tested that have been in service for more than 24 months in industrial applications will not perform to specification when as found trip tests are performed. After exercise and operation, cleaning and proper lubrication this is reduced to less than 12 %. This data comes from a cross reference of Group CBS company results compiled over 2000 breakers.

Validity of Arc Flash Analysis Assume a worker is racking out a 600V feeder breaker for the purpose of LOTO. Arc Flash label requires the worker to wear 40 cal/cm 2 flash suit THE INFORMATION IS PROVIDED WITH NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. NO USE SHOULD BE MADE OF THE INFORMATION EXCEPT BY FULLY QUALIFIED PROFESSIONALS HAVING FORMED THEIR OWN EVALUATION OF THE INFORMATION FOR THEIR OWN PURPOSES AND APPLICATIONS. INFORMATION BASED ON NFPA 70E. (SS Ver. 13) NFPA eq. B - 5.1 NFPA eq. B - 5.2 Equation for Arc in Open Air D A = distance from arc electrodes, inches (for distances 18 in. and greater) t A = arc duration, seconds (cycles / 60 cycles) F = bolted fault short circuit current, in ka (for the range of 16 to 50kA) E MA = 5271 x D -1.9593 A x t A x (0.0016 x F 2-0.0076 x F + 0.8938) E MA = maximum open arc incident energy ANSWER 14.028 cal/cm 2 Equation for Arc in a Cubic Box D B = distance from arc electrodes, inches (for distances 18 in. and greater) t B = arc duration, seconds (cycles / 60 cycles) F = bolted fault short circuit current, in ka (for the range of 16 to 50kA) E MB = 1038.7 x D B -1.4738 x t A x (.0093 x F 2 -.3453 x F + 5.9675) E MB = maximum 20 in. cubic box incident energy ANSWER 24 0.5 36 24 0.5 36 26.8335 Arc Flash Protection (bolted fault) Boundary inches seconds ka inches seconds ka cal/cm 2 NFPA eq. B- 2-1 MVA bf = bolted fault MVA at point involved V = volts % Z = percent impedance based on transformer MVA t = time of arc exposure in seconds, (cycles / 60 cycles) I SC = {{[MVA Base x 10 6 ] / [1.732 x V]} x 100 / % Z} 3 480 5 0.1 MVA volts % Z seconds

Validity of Arc Flash Analysis Main breaker fails to trip Worker may be exposed to 107 cal/cm 2, the 40 cal/cm 2 flash suit will fail The worker did nothing wrong, who is at fault? THE INFORMATION IS PROVIDED WITH NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. NO USE SHOULD BE MADE OF THE INFORMATION EXCEPT BY FULLY QUALIFIED PROFESSIONALS HAVING FORMED THEIR OWN EVALUATION OF THE INFORMATION FOR THEIR OWN PURPOSES AND APPLICATIONS. INFORMATION BASED ON NFPA 70E. (SS Ver. 13) NFPA eq. B - 5.1 NFPA eq. B - 5.2 Equation for Arc in Open Air D A = distance from arc electrodes, inches (for distances 18 in. and greater) t A = arc duration, seconds (cycles / 60 cycles) F = bolted fault short circuit current, in ka (for the range of 16 to 50kA) E MA = 5271 x D -1.9593 A x t A x (0.0016 x F 2-0.0076 x F + 0.8938) E MA = maximum open arc incident energy ANSWER 56.110 cal/cm 2 Equation for Arc in a Cubic Box D B = distance from arc electrodes, inches (for distances 18 in. and greater) t B = arc duration, seconds (cycles / 60 cycles) F = bolted fault short circuit current, in ka (for the range of 16 to 50kA) E MB = 1038.7 x D B -1.4738 x t A x (.0093 x F 2 -.3453 x F + 5.9675) E MB = maximum 20 in. cubic box incident energy ANSWER 24 2 36 24 2 36 107.3341 Arc Flash Protection (bolted fault) Boundary inches seconds ka inches seconds ka cal/cm 2 NFPA eq. B- 2-1 MVA bf = bolted fault MVA at point involved V = volts % Z = percent impedance based on transformer MVA t = time of arc exposure in seconds, (cycles / 60 cycles) I SC = {{[MVA Base x 10 6 ] / [1.732 x V]} x 100 / % Z} 3 480 5 0.1 MVA volts % Z seconds

Case Study 1 - Overview This accident occurred on Jan 5, 1993 at Gulf States Electric Utilities in Beaumont, TX When company and contract electricians forced a 5 kv Federal Pacific circuit breaker from the cell after it became lodged in the structure, the resulting arc flash killed 2 employees and severely burned 3 others. All of the technicians that were killed and badly burned were wearing arc flash PPE. This arc blast was un-survivable with any known PPE. Increasing the working distance through the use of remote racking and switching devices would have saved these people from injury.

Case Study 1 - Details The 5 kv breaker was moved from a switchboard in an adjacent unit that was down. The switchboard it was installed in that day was several years newer but the same type, however, the MOC operator was located at a different height. When the breaker was given a close command it tried to close but was jammed half way through the close cycle. The day shift went home and left the instructions for contract electricians to get the breaker out and locate the issue. When they removed it, the breaker continued the close command and a tremendous arc flash occurred.

Case Study 1 - Prevention This accident could have been avoided with proper training and operational know how. When any obstruction is encountered the first step is to schedule a shutdown and investigate the problem in an off line scenario. Never trouble shoot this type of blocked operation mechanical failure online. Remote devices should always be used when a problem is suspect to take the equipment offline

ArcSafe Solutions RRS2 RRS-2 Installation and Removal

Case Study 2 - Overview March 4, 2009, at the Jubail Project in Riyadh, Saudi Arabia Three workers were removing a 480-volt, molded-case circuit breaker from the bucket of an energized Motor Control Center (MCC) when an electrical arc flash occurred, severely injuring them.

Case Study 2 - Details All three sustained first- and seconddegree burns and were hospitalized following the accident. Myth: Switchgear is designed with arc flash containment in mind MCC Arc Flash

Case Study 2 - Prevention The system should have been deenergized to perform this task If de-energizing was not feasible the bucket could have been extracted remotely

Case Study 2 - Prevention Remote switching actuators could have opened the molded case breaker. RSA-37 Siemens MCC

Case Study 2 - Prevention Remote Racking Bucket Extractor could have removed the MCC bucket safely RRS-2 Bucket Extractor

Case Study 3 - Overview On May 23 rd, 2009 a power plant in the Midwest experienced a severe arc flash incident The incident occurred while racking in a closed Siemens 15 kv GMI breaker with a faulty interlock When the (closed) breaker contacted the bus, a large arc flash occurred

Case Study 3 - Details The breaker was being racked in remotely (Wireless), the operators were in another room and there were NO injuries of any kind. The RRS-1 was used after the arc flash incident to remove the damaged GMI from the cell for evaluation. Plant personnel that were present are convinced that lives were saved that day

Case Study 3 - Solution RRS-1 with camera and light

Lesson Learned This Siemens GMI 15 kv Vacuum Breaker has a broken push rod, the breaker shows open however on pole is closed This was concealed from our technicians behind the faceplate GCBS procedure is to open the mains and work from a dead buss when possible. This procedure saved our technician from a possible injury from the arc flash that would have occurred.

Summary Each year, over 2,000 arc flash victims are sent to burn centers It is rarely one thing that will defeat the system but often a series of events that lead to a failure of systems and procedures. These are often not considered, or determined to be so remote that they are not planned for. Broken components, safety interlocks and foreign matter can stack the cards against you.

Summary People make mistakes, that s why we call them accidents OCPD s can fail, PPE can fail, enclosures can fail Increasing working distance is the best, safest, most fool proof, and in many cases the most cost effective mitigation method

Conclusion Routine circuit breaker maintenance can help prevent failures and ensure the accuracy of the arc flash study When dealing with an actual Arc Flash incident mitigation is distance Distance is Truly Safety Q&A