Reducing Arc Flash Risks with Electrical Maintenance Safety Devices

Similar documents
OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010

WHAT IS INFRARED (IR) THERMOGRAPHY

Roadmap to Compliance with NFPA 70E Arc Flash Requirements

I Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc.

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

Progress in Impacting Policy in Workplace Electrical Safety

SEE IT. SAVE IT. SHARE IT. Preventive maintenance simplified with Fluke Connect Assets.

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

Worldwide Thermography Headquarters

Electrical Predictive and Preventative Maintenance

Arc flash can kill. Arc flash can be considered as a short circuit through

2013WWOA Conference Technical Conference Program

How to Build a Safe and Effective Electrical Maintenance Program

Electrical Safety in the Workplace

SALISBURY ASSESSMENT SOLUTIONS

INTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

What s up with Arc Flash?

Predictive Maintenance

Part 1 System Modeling & Studies for Existing Systems

How to reduce exposure to arc flash hazards

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

2012 NFPA 70E. Ten Most Important Changes. John A. DeDad

Analyzing Electrical Hazards in the Workplace

Concerned about arc-flash and electric shock?

Vilter motor starter solutions The NEW industry standard in motor starter packages

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

Arc Flash Energy Mitigation Techniques

Understanding 2015 Changes to NFPA 70E Safety-related work practices and maintenance requirements mandate more robust electrical safety programs for

Understanding Arc Flash

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

2008 Eaton Corporation. All rights reserved.

misconceptions about arc-flash hazard assessments

Job Site Electrical Safety A Matter of Life and Death

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

Installation Instructions for Alarm Module Kit A043F059

INSPECTION AND TESTING OF EMERGENCY GENERATORS

ARC FLASH HAZARD MITIGATION. Industrial Tests, Inc. [indtests.com]

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

NFPA 70E Updates Affect Your Most Valuable Assets

Electrical Preventive Maintenance Pays Off! A case study on controlling risks to plant & profits

Choosing the Best Solution for Reducing Arc Energy

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

OPTIONAL INFORMATION ELECTRICAL SAFETY WORK PRACTICES SELF INSPECTION CHECKLIST

INFRARED WINDOWS APPLIED IN SWITCHGEAR ASSEMBLIES: TAKING ANOTHER LOOK

10 Things You Need To Know About Infrared Windows

90.2(A) Covered & 90.2(B) Not Covered 6/23/2015. Learning Objectives. 90.2(A) Covered & 90.2(B) Not Covered. Change Summary

100% Rule Alternate Method Arc Blast Arc Flash Approved Approved Equipment Authority Having Jurisdiction (AHJ) Authorized Work Bare Hand Work

The Costs and Risks Associated with Improper Service and Maintenance of Electrical Systems

Grounding and Bonding Against Static Electricity. Jon Koppari, CSP, MS Occupational Safety and Health Instructor OSHA Training Institute

The Three A s of Arc Flash

Arc Flash Mitigation. Executive summary. by Antony Parsons, Ph.D., P.E.

SALISBURY ASSESSMENT SOLUTIONS

The Other Hazard of Electricity. Larren Elliott Ph.D. Lindsay Polic, CSP, REHS

ETAP Arc Flash Analysis

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

PRESENTED AT THE 2011 IEEE IAS PULP & PAPER INDUSTRY TECHNICAL CONFERENCE, NASHVILLE, TN: IEEE PERSONAL USE OF THIS MATERIAL IS PERMITTED.

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

High Voltage Electrical Equipment Failure Diagnosis. Presented by: Spencer Tang & Terence Ng T&T Inspection & Engineering Sdn Bhd

Ultrasound Condition Monitoring

Midwest Healthcare Engineering Conference and Trade Show 2012 Indianapolis, Indiana

UL S RISK ASSESSMENT PROGRAM HELPING UNDERSTAND HAZARDS IN MACHINERY

Massachusetts FACE Occupational Fatality Report

Arc Flash Mitigation & Selective Co-ordination

employed to ensure the continuing reliability of critical systems.

Tune Up Your Condition Monitoring Program by Answering the Five W s

How to Develop an Effective Training Program (Training electrical maintenance employees to be qualified)

Hazard/Risk Identification and Control Procedure

ARC VIEW. Emerson Asset Optimization Business Breaks New Ground. Summary. A Business of Vital Strategic Importance.

Who sets the rules for electrical testing and safety?

3053 Electrical Safety Training Program Course Outline

For Predictive Maintenance Technologies

Electrical Safety Program

Low Voltage Switchgear

Advancements in the Practice of Electrical Safety

21 st Century Facilities

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

electrical services

Reducing Liability through Safety Labeling - Industrial Automation. Todd Fries

Preventative Maintenance & Statutory Testing

INFORMATION BULLETIN No. 145

! WARNING Arc Flash and Shock Hazard Appropriate PPE Required

Understanding Emergency Power Off (EPO)

Automation & Power World Improving safety Through arc resistant switchgear and arc reducing components. ABB Wednesday, 23 March 2011 Slide 1

MODULE 1 INTRODUCTION TO ELECTRICAL SAFETY

Electrical Distribution Services for Mining and Metals Industries

TRAINING INSTITUTE. Keeping people safe from electrical hazards Course Catalog. A Subsidiary of Megger

OSHA Training Guidelines (An Unofficial Summary)

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

Dielectric Withstand Testing in a Production Environment

FACILITY SAFETY SIGNAGE GUIDE: 10 SIGNS TO SPOT DURING A PLANT WALKTHROUGH

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Transcription:

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices By: Martin Robinson, CEO of IRISS Group and Level III Thermographer Abstract Electrical accidents, such as arc flashes, happen daily; however, there are ways companies and individuals can reduce the occurrence of these accidents and protect everybody concerned from the physical, financial, and statutory consequences. The National Fire Protection Association (NFPA) regulation 70E provides a reference for facilities to meet the requirements of electrical workplace safety while regulation 70B outlines the best practices for setting up and maintaining and Electrical Preventive Maintenance (EPM) program. 18-1030-0007 Rev. A

VALUE OF NFPA At the heart of NFPA 70E and OSHA initiatives is the hierarchy of control. This concept attempts to mitigate arc flash risk wherever possible. In order of preference, the hierarchy of control prioritizes: 1. Risk Elimination 2. Substitution (with lower risk) 3. Engineering Controls (such as arc resistant switchgear) 4. Safe Work Practices 5. PPE NFPA 70E and OSHA state that electrical equipment should be de-energized prior to opening. Some maintenance tasks have to be completed while the switchgear is loaded and energized, rapidly causing electrical maintenance safety devices (EMSDs) to be a hot topic. Their popularity is growing as companies strive to improve profitability, uptime and safety. Those who are implementing EMSD based programs are reaping significant benefits in terms of efficiency gains, cost control and fire prevention. Because lower PPE levels are required, inspections are quicker. IRISS offers courses that train on content from NFPA 70E standards. EMSDs in Action One of the tasks that need to be completed on electrical equipment whilst it is energized and under load is infrared (IR) scanning. IR cameras can only measure what they can see and cannot see through glass or plastic viewing windows commonly fitted in switchgear. To allow the inspections to be completed under load, we use an IR window, an EMSD, that allows an IR camera to see the energized loaded connections through a special lens materials in the IR windows. Allowing switchgear to remain closed and in a safe and guarded condition thus ensuring that the inspector is never exposed to the dangers of arc flash or electrocution. Much of the recent acceptance of IR windows has coincided with the increase

in level of awareness regarding electrical safety, risk reduction and arc flash. Organizations such as the IEEE have been at the vanguard of this movement with its Safer by Design campaign. In response, switchgear manufacturers are increasingly installing IR window at the point of manufacture. With IRISS IR windows, inspectors are never exposed to the dangers of arc flash. Other tasks where EMSDs are used to eliminate a potential arc flash include: Airborne Ultrasound (EMSD - Ultrasound Ports) Voltage Detection (EMSD - External Voltage detection ports) Motor Current Analysis (EMSD Voltage Tap Off Connections) Other EMSD strategies include the use of online monitoring systems that transmit data back directly to the client utilizing either wired or wireless sensor systems. These systems include: Temperature measurement (Contact and non-contact systems) Vibration Analysis (Rotating UPS and generator Systems) Power Quality (Online and fixed data collection systems) Partial Discharge (Online and fixed data collection systems) Benefits of EMSDs The benefit of using ESMDs is that they standardize the inspection routes as they become data collection points for the test equipment. They also ensure that all the inspection parameters are fixed and that all collected data is standardized ensuring that any trend analysis data is accurate. Other benefits include: Maintain switchgear in an enclosed and guarded condition Remove risk of electrocution and possible triggers of an arc flash incident Removal of high risk behaviors

Conduct valuable, fully loaded online inspections Access Inaccessible equipment Because there is no panel removal required: o inspections require less manpower o inspections require lower Personal Protection Equipment (PPE) levels o inspections are faster and more efficient o More inspections are completed due to ease of operation IRISS windows allow for fully loaded online inspections. Summary It is significant that most electrical maintenance and safety standards value the use of Condition Based Maintenance (CBM) inspections such as IR surveys, ultrasound inspections, vibration analysis, MCA, and partial discharge testing as a critical part of an electrical preventative maintenance program (EPM). EMSDs, such as IR windows, have now provided a way for companies to comply with the recommendations for inspection processes, while complying with the mandate for arc flash avoidance. Most if not all of these organizations agree that electrical equipment should not be opened unless it is de-energized. EMSDs provide a way for companies to comply with recommendations for inspection and safety standards/guidelines while protecting personnel, equipment and profits. ABOUT THE AUTHOR For over 30 years, Martin Robinson has been a pioneer in the field of maintenance technology. Robinson, an innovator and pioneer of Infrared (IR) Thermography has consulted with international maintenance and reliability leaders on electrical preventive maintenance and electrical safety standards of NFPA and OSHA. A recognized authority in the field of IR Thermography, Robinson has designed CBM programs to include IR, Nondestructive Testing (NDT) and implementation of green energy initiatives and energy management strategies. He is Level III Certified IR Thermographer, Certified Maintenance

and Reliability Professional (CMRP) through the Society for Maintenance and Reliability Professionals (SMRP), member of IEEE, NFPA and is a standing member on the technical committee CSA Z463 guidelines on maintenance of electrical systems and IEEE P1854 - Electrical System Design to Improve Electrical Safety. 10 Things You Need to Know about Infrared Windows contains more information on the benefits of IR windows. To get your free digital copy, Click Here. Interested in IRISS IR Window Solutions? Click Here