KDL/E cable entry system



Similar documents
Cable entry plate KDP

Accessories for cable entry systems and plates

08. SEK IDC CONNECTORS

Automation Solutions. LÜTZE LCOS empty housing for Industrial Automation

Cable Cubby 1200 and 1400 Installation Guide

Rack installation instructions

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

Mini USB and USB 2.0-IP67 Connector System

Intermat. Hinge technology of the highest order

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

ASKING FOR ASSISTANCE

How To Build A Powerline Box Powerline Generator

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

Original Assembly Guide

Rittal TopTherm fan-and-filter unit

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

I NTERFACE CABLE ADAPTER MODULE

Multi-talented. Valve and valve terminal series VG

Directory chapter 04

Simpler all over. Simpler all round. fully Ether. PoE+ shielded. MHz. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

HP 16/18-Port Cable Management Kit Installation Guide

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Terminal Boxes Series 8146

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

Triac Printed Circuit Board Replacement

Control Box Wiring For PRSstandard Tool

What ensures easy and fast wiring?

1 Introduction - Advice Conductor Rails Track Coupler Power feeds Air Gap Insulation Section... 6

CONEC SnapLock. 1 Introduction

Instrument panel. Volkswagen Touareg - Instrument panel. Special tools, testers and auxiliary items required. Release lever T10039

Description. Dimensions. Features. precision works better

Quick Reference Guide Euro Style Terminal Blocks

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Cabinets 101: Configuring A Network Or Server Cabinet

Edition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue

HARTING Ethernet Cabling 4-poles Overview

ASSEMBLY INSTRUCTIONS Residential Roof solutions

The range of rail-mounted terminal blocks. for a perfect electrical installation.

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

HARTING Ethernet Cabling 8-poles Overview

Mounting and operating instructions. Surface-mounted hands-free feature home station

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

gesis IP + Heavy Duty Class I, Zone 2

Copper Pre-terminated Assemblies

Installation and Assembly: Desktop Mount with Desk Clamp and Grommet for 19" - 30" LCD Screens

DIY Y6. Build Manual V.A 2014

Meeting Room Solutions

ODU MINI-SNAP. Miniature Cylindrical Connectors with Push-Pull-Locking Series F

INSTALLATION INSTRUCTIONS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Product Information. HMC 6 Hybrid Motor Cable

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

LIEBERT VNSA Installation Sheet

AutoDome Easy II. VEZ Series. Mounting Manual

The STRIKE Connector System

Contractors Guide Central Inverter System Installation

ALLROUNDER 420 C GOLDEN EDITION

Redundancy Module QUINT-DIODE/40

INSTALLATION INSTRUCTIONS

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

SECURITY SYSTEM SMART SIREN KIT

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

CoolWave r 2 Phase Control Board and Cable Replacement Kits

A&C Solutions: please contact us.

WINSTA The Pluggable Connection System A Complete Range of Connectors

Part Name/Description Part Number Quantity. Power Cable

4RU High Density Shelf Installation Instructions

GSM-EXT Cable Assembly Installation Guide

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

COB panel supports for multipole connectors

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

Installation instructions, accessories. Cruise control. Volvo Car Corporation Gothenburg, Sweden. Instruction No Version Part. No

Operating Instructions

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Universal MATE-N-LOK Connectors

CUSTOM AUXILIARY FORWARD LIGHTING KIT

Feed-through terminal blocks for high-current applications

Description ELGO PNO 1 SSI/ Profibus - Converter

DIRECTIONS FOR ASSEMBLING BASE & WALL CABINETS

Electro-pneumatic control valves

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Product and functional description

CELO5. User & Installation Manual.

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES TO 20 (4) A 250 V AC

Chapter 10 - Scaffolding Systems

Installing Cisco TelePresence MX200 G2 - Wheel Base

Linkeo 19" freestanding cabinets

RiMatrix S Make easy.

3-Component Measuring System

QM (1.78mm-.070") CONNECTORS-"MICRO 70"

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

Transcription:

2005 Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murrplastik.com

Advantages Safe and easy cable entry The KDL/E cable entry system substantially reduces assembly times for pre-assembled cables with diameters between 3 and 31 mm. The cable entry system can be configured with up to 20 cables. Cables with plugs no longer need to be dismantled. They can be routed into the housing directly and without interruption. Standardised cut-outs can be used (e.g. Harting, Wieland, Rittal). A clever latching system makes assembly, disassembly and subsequent configuration of the cable entry system intuitively easy. Grommets can be obtained in different sizes, for several cables, for cable protection conduits and for ASI cables. Advantages: Easy entry of pre-assembled cable connectors Huge time savings thanks to interruption-free cable guidance Rapid assembly Simple strain relief High degree of protection (IP 54) High packing density 2 Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murrplastik.com

Advantages Interruption-free cable infeed Cables for data, control, bus and test signals as well as pre-assembled cables can be routed into the housing free of interruptions. Introduction of control and conduit cables with attached connectors providing for quick disconnection (system integrity remains valid). Fast and easy assembly The split grommet is positioned about the cable and simply inserted into the KDL/E frame. KDL/Es are configured entirely without tools. Strain relief For additional strain relief, cables can be secured with cable ties thanks to fixing lugs moulded to grommets. Click and bolt system There are two fastening versions for the KDL/E system. With the click system, the KDL/E is simply latched to the standard cut-out by two snap hooks. The snap hooks can be used for plate thickness of 0.06-0.08. Alternatively, the KDL/E can be fastened with four bolts in cases of extremely high mechanical stress. Vario grommet The Vario grommet has a flexible membrane. This membrane allows different cable diameters to be routed through a Vario grommet. Only 2 versions of the Vario grommet are required to route cables with a diameter ranging from 0.11 to 0.39. Adapted to standard cut-outs The fixing dimensions have been adapted to suit standard connector cut-outs for sizes 16 and 24 (e.g. Wieland, Harting and Rittal). High packing density The KDL/E system can route up to 20 cables into a control cabinet for a standard connector cut-out for size 24 connectors. An optimal use of space, indeed. Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murr 3

Cable entry system, type KDL/E 16 KDL/E cable entry system The KDL/E represents the ongoing further advancement of third generation Murrplastik cable entry systems. Even faster assembly of pre-assembled cables. Further reduced installation time of the entire KDL/E on standard cutouts for 16-pin connectors (e.g. Harting, Wieland and Rittal) by way of catch hooks. Screwing on is no longer absolutely necessary. Variable grommets with a larger clamping range (Vario grommets) translate into fewer grommet sizes required. KDL/E 16/x The KDL/AB discharge plate, in conjunction with the KDL/E, is suited for discharging interference which may occur on cable sheaths. The discharge plate is mounted on the inside of the control cabinet. KDL/AB 16/x-EMV Type Order no. Color No. of openings No. Installation height Pack small / large of discharges inch KDL/E 16/2 87121010 Black - / 2 0.61 1 KDL/E 16/5 87121012 Black 4 / 1 0.61 1 KDL/E 16/8 87121014 Black 8 / - 0.61 1 Catch hook (replcm. part) 8712102000 Black 1 Fitting marked label KS-KDL/E 86421090 White 100 EMC discharge plate KDL/AB 16/2-EMV 87252410 2 1 KDL/N-AB 16/5-EMV OT 87252420 3 1 KDL/N-AB 16/5-EMV UT 87252422 2 1 KDL/N-AB 16/8-EMV 87252424 4 1 4 Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murrplastik.com

Cable entry system, type KDL/E 24 The KDL/E represents the ongoing further advancement of third generation Murrplastik cable entry systems. Even faster assembly of pre-assembled cables. Further reduced installation time of the entire KDL/E on standard cutouts for 24-pin connectors (e.g. Harting, Wieland and Rittal) by way of catch hooks. Screwing on is no longer absolutely necessary. Variable grommets with a larger clamping range (Vario grommets) translate into fewer grommet sizes required. KDL/E 24/x The KDL/AB discharge plate, in conjunction with the KDL/E, is suited for discharging interference which may occur on cable sheaths. The discharge plate is mounted on the inside of the control cabinet. KDL/AB 24/x-EMV Type Order no. Color No. of openings No. Installation height Pack small / large of discharges inch KDL/E 24/4 87121016 Black 2 / 2 0.61 1 KDL/E 24/7 87121018 Black 6 / 1 0.61 1 KDL/E 24/10 87121020 Black 10 / - 0.61 1 Catch hook (replcm. part) 8712102000 Black 1 Fitting marked label KS-KDL/E 86421090 White 100 Fitting adapter plates KDP 24/AP/xx for the assembly of multiple KDL/E 24 in standardised cut-outs (Rittal/Lohmeier/Ensto) See cable entry and cable holding systems catalogue EMC discharge plate KDL/N-AB 24/4-EMV OT 87252426 3 1 KDL/N-AB 24/4-EMV UT 87252428 1 1 KDL/N-AB 24/7-EMV OT 87252430 4 1 KDL/N-AB 24/7-EMV UT 87252432 3 1 KDL/N-AB 24/10-EMV OT 87252434 5 1 KDL/N-AB 24/10-EMV UT 87252436 5 1 Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murr 5

Cable entry grommets, type KDT/xE KDL/E cable entry system In conjunction with the KDL/E cable entry system, the KDT/xE cable entry grommet can be used to easily route pre-assembled cables e.g. in control cabinets. The grommet is 2-pce. and is positioned about the cable. The grommets are equipped with catch hooks which anchor themselves in the KDL/E when positioning. Strain relief for type KDT/ZE is achieved using a simple cable tie. Type KDT/VE is a Vario grommet without strain relief which covers a larger clamping range. Standard grommets Special grommets Type Order no. Color For Ø For entry Pack inch small / large KDT/ZE 03 87121210 Black 0.11-0.15 / - 10 KDT/ZE 04 87121212 Black 0.15-0.19 / - 10 KDT/ZE 05 87121214 Black 0.19-0.23 / - 10 KDT/ZE 06 87121216 Black 0.23-0.27 / - 10 KDT/ZE 07 87121218 Black 0.27-0.31 / - 10 KDT/ZE 08 87121220 Black 0.31-0.35 / - 10 KDT/ZE 09 87121222 Black 0.35-0.39 / - 10 KDT/ZE 10 87121224 Black 0.39-0.43 / - 10 KDT/ZE 11 87121226 Black 0.43-0.47 / - 10 KDT/ZE 12 87121228 Black 0.47-0.51 / - 10 KDT/ZE 13 87121230 Black 0.51-0.55 / - 10 KDT/ZE 14 87121232 Black 0.55-0.59 / - 10 KDT/ZE 15 87121234 Black 0.59-0.62 / - 10 KDT/ZE 16 87121236 Black 0.62-0.66 - / 10 KDT/ZE 17 87121238 Black 0.66-0.70 - / 10 KDT/ZE 18 87121240 Black 0.70-0.74 - / 10 KDT/ZE 19 87121242 Black 0.74-0.78 - / 10 KDT/ZE 20 87121244 Black 0.78-0.82 - / 10 KDT/ZE 21 87121246 Black 0.82-0.86 - / 10 KDT/ZE 22 87121248 Black 0.86-0.90 - / 10 KDT/ZE 23 87121250 Black 0.90-0.94 - / 10 KDT/ZE 24 87121252 Black 0.94-0.98 - / 10 KDT/ZE 25 87121254 Black 0.98-1.02 - / 10 KDT/ZE 26 87121256 Black 1.02-1.06 - / 10 KDT/ZE 27 87121258 Black 1.06-1.10 - / 10 KDT/ZE 28 87121260 Black 1.10-1.14 - / 10 6 Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murrplastik.com

Cable entry grommets, type KDT/xE Type Order no. Color For Ø For entry Pack inch small / large KDT/ZE 29 87121262 Black 1.14-1.18 - / 10 KDT/ZE 30 87121264 Black 1.18-1.22 - / 10 Variable cable grommet KDT/VE 3-8 87121272 Black 0.11-0.31 / - 10 KDT/VE 7-10 87121274 Black 0.27-0.39 / - 10 Double cable grommet KDT/ZE 2x4 87121284 Black 2 x 0.15 / - 10 KDT/ZE 2x5 87121286 Black 2 x 0.19 / - 10 KDT/ZE 2x6 87121288 Black 2 x 0.23 / - 10 ASI grommet KDT/ZE 2xASI 87121280 Black ASI cable / - 10 KDT/ZE ASI 87121282 Black ASI cable / - 10 Adapter grommet ATG/E 87121268 Black Adapter for small grommet - / Conduit grommet SDT/ZE 07 87174250 Black / - 10 SDT/ZE 09 87174252 Black / - 10 SDT/ZE 11 87174254 Black / - 10 SDT/ZE 16 87174256 Black - / 10 SDT/ZE 21 87174258 Black - / 10 SDT/ZE EWT 10 87174220 Black / - 10 SDT/ZE EWT 14 87174222 Black - / 10 SDT/ZE EWT 20 87174224 Black - / 10 Dummy grommet BTK/E 87121266 Black Dummy grommet, small / - 10 BTG/E 87121270 Black Dummy grommet, large - / 10 Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murr 7

Blanking plate, type BP/x BP/N KDL/E cable entry system The BP/N blanking plate is used for sealing prepared but unused standard cut-outs for 24-pin connectors (e.g. Harting, Wieland and Rittal). For clip action fastening or screwing in place. IP 65 protection rating as per DIN 60529. The BP/H blanking plate also is used for sealing prepared but unused standard cut-outs for 24-pin connectors (e.g. Harting, Wieland and Rittal). Assembly is via clip action. IP 42 protection rating as per DIN 60529. BP/H Type Order no. Color Installation height Pack inch BP/N 24 87171624 Black 0.61 1 BP/H 24 87171626 Black 0.19 1 8 Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murrplastik.com

Comparison of KDL/N to KDL/E The KDL/N cable entry system and related accessories will be replaced by the new KDL/E series. Using the following list, you can transfer the KDL/N components over to the new KDL/E components. KDL/N frame Article number KDL/E frame Article number KDL/N 16/2 87173008 KDL/E 16/2 87121010 KDL/N 16/4 87173010 KDL/E 16/5 + BTG/E 87121012 + 87121270 KDL/N 16/5 87173012 KDL/E 16/5 87121012 KDL/N 16/8 87173013 KDL/E 16/8 87121014 KDL/N 24/4 87173014 KDL/E 24/4 87121016 KDL/N 24/5 87173015 KDL/E 24/10 + 5 pcs. BTK/E 87121016 + 5 pcs. 87121266 KDL/N 24/7 87173016 KDL/E 24/7 87121018 KDL/N 24/10 87173018 KDL/E 24/10 87121020 KDL/N 16/4-EMV 87173020 KDL/E 16/5 + BTG/E + discharge plates KDL/N-AB 16/5-EMV OT and UT 87121012 + 87121270 + 87252420 + 87252422 KDL/N 16/5-EMV 87173022 KDL/E 16/5 + discharge plates KDL/N-AB 16/5-EMV OT and UT 87121012 + 87252420 + 87252423 KDL/N 16/8-EMV 87173023 KDL/E 16/8 + 2 pcs. discharge plates KDL/N-AB 16/8-EMV 87121014 + 2 pcs. 87252424 KDL/N 24/4-EMV 87173024 KDL/E 24/4 + discharge plates KDL/N-AB 24/4-EMV OT and UT 87121016 + 87252426 + 87252428 KDL/N 24/5-EMV 87173025 KDL/E 24/10 + 5 pcs. BTK/E + discharge plates KDL/N-AB 24/10-EMV OT 87121016 + 5 pcs. 87121266 + 87252434 KDL/N 24/7-EMV 87173026 KDL/E 24/7 + discharge plates KDL/N-AB 24/7-EMV OT and UT 87121018 + 87252430 + 87252432 KDL/N 24/10-EMV 87173028 KDL/E 24/10 + discharge plates KDL/N-AB 24/10-EMV OT and UT 87121020 + 87252434 + 87252436 KDL/N small grommets Article number KDL/E small grommets Article number KDT/ZN 03 87172612 KDT/ZE 03 87121210 KDT/ZN 04 87172614 KDT/ZE 04 87121212 KDT/ZN 05 87172616 KDT/ZE 05 87121214 KDT/ZN 06 87172618 KDT/ZE 06 87121216 KDT/ZN 07 87172620 KDT/ZE 07 87121218 KDT/ZN 08 87172622 KDT/ZE 08 87121220 KDT/ZN 09 87172624 KDT/ZE 09 87121222 KDT/ZN 10 87172626 KDT/ZE 10 87121224 KDT/ZN 11 87172628 KDT/ZE 11 87121226 KDT/ZN 12 87172630 KDT/ZE 12 87121228 KDT/ZN 13 87172632 KDT/ZE 13 87121230 KDT/ZN 14 87172634 KDT/ZE 14 87121232 KDT/ZN 15 K 87172636 KDT/ZE 15 87121234 BTK/N (dummy grommet) 87172610 BTK/E (dummy grommet) 87121266 KDT/VE 3-8 Vario grommet 87121272 KDT/VE 7-10 Vario grommet 87121274 KDT/ZN 2x4,0 87175431 KDT/ZE 2x4,0 double grommet 87121284 KDT/ZN 2x5,0 87175438 KDT/ZE 2x5,0 double grommet 87121286 KDT/ZN 2x6,0 87175432 KDT/ZE 2x6,0 double grommet 87121288 KDT/ZN 2xASI 87175430 KDT/ZE 2xASI 87121280 KDT/ZN ASI 87175434 KDT/ZE ASI 87121282 SDT/ZN EWT10 87175470 SDT/ZE EWT10 87174220 SDT/ZN 07 87175450 SDT/ZE 07 87174250 SDT/ZN 09 87175452 SDT/ZE 09 87174252 SDT/ZN 11 87175454 SDT/ZE 11 87174254 KDL/N large grommets Article number KDL/E large grommets Article number KDT/ZN 16 87172812 KDT/ZE 16 87121236 KDT/ZN 17 87172814 KDT/ZE 17 87121238 KDT/ZN 18 87172816 KDT/ZE 18 87121240 KDT/ZN 19 87172818 KDT/ZE 19 87121242 KDT/ZN 20 87172820 KDT/ZE 20 87121244 KDT/ZN 21 87172822 KDT/ZE 21 87121246 KDT/ZN 22 87172824 KDT/ZE 22 87121248 KDT/ZN 23 87172826 KDT/ZE 23 87121250 KDT/ZN 24 87172828 KDT/ZE 24 87121252 KDT/ZN 25 87172830 KDT/ZE 25 87121254 KDT/ZN 26 87172832 KDT/ZE 26 87121256 KDT/ZN 27 87172834 KDT/ZE 27 87121258 KDT/ZN 28 87172836 KDT/ZE 28 87121260 KDT/ZN 29 87172838 KDT/ZE 29 87121262 KDT/ZN 30 87172840 KDT/ZE 30 87121264 BTG/N32 (dummy grommet) 87172810 BTG/E (dummy grommet) 87121270 ATG/N (adapter grommet) 87175436 ATG/E (adapter grommet) 87121268 SDT/ZN EWT14 87175472 SDT/ZE EWT14 87174222 SDT/ZN EWT20 87175474 SDT/ZE EWT20 87172224 SDT/ZN 16 87175456 SDT/ZE 16 87174256 SDT/ZN 21 87175458 SDT/ZE 21 87174258 There is no direct comparison type available for all KDL/N series articles not listed here. If you have any questions, please feel free to contact our support staff by e-mail at kdle@murrplastik.de. Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murr 9

Snap-on mount assembly instructions (for plate thickness 0.06-0.08 ) Pierce two square membranes with a screwdriver. Connect the snap hooks included in the scope of delivery to the plate. Connect fully configured frame to the snap hooks. Ideally, open frame side in the direction of the cables to be routed. Pry up the snap hooks with a screwdriver until an audible click can be heard. Quickly press on grommets. Screw fastening assembly instructions (for plate thickness < 1.5 mm/> 2.0 mm) Pierce four round membranes with a screwdriver. Secure fully configured frame with 4 screws (M5). Press on grommets at the marked position. Ideally, open frame side in the direction of the cables to be routed. 10 Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murrplastik.com

Grommet assembly Route cable, close grommet and attach a cable tie around the strain relief lug if necessary. When connecting the grommets, ensure that the sealing lip is at the correct position. A fully configured KDL/E must have a continuous seal. Disassembly of frame/grommets Remove screws and detach KDL/E. Remove grommets only after detaching the KDL/E. Press catch hooks outward by hand and detach KDL/E. Remove grommets only after detaching the KDL/E. Loosen grommets out of their anchoring on both sides with a screwdriver. Remove grommets from the unit by hand. Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 215-822-7625 215-822-7626 cablemgmt@murrplastik.com www.murr 11

Head Office Germany Switzerland Murrplastik AG Ratihard 40 8253 Willisdorf Phone: +41 52 646 06 46 Fax: +41 52 646 06 40 www.murrplastik.ch info@murrplastik.ch France Murrtechnic S.à.r.l Zone industrielle Sud, 6 rue Manurhin B.P. 62, 68120 Richwiller Phone: +33 389 570 01 0 Fax: +33 389 530 96 6 www.murrtechinc.fr murrtechnic@murrtechnic.fr Austria Murrplastik Systemtechnik GmbH Phone: +43 732 660 870 Fax: +43 732 660 872 www.murrplastik.at info@murrplastik.at Murrplastik Systemtechnik GmbH Postfach 1143 D- 71567 Oppenweiler Phone: +49 7191 4820 Fax: +49 7191 482 280 www.murrplastik.de info@murrplastik.de Spain Murrplastik S.L. Paseo Ubarburu, 76 Pabellón 34, polígono 27 20014 San Sebastián Phone: +34 943 472 22 5 Fax: +34 943 472 89 5 www.murrplastik.es info@murrplastik.es USA Murrplastik Systems Inc. 2367 North Penn Road Suite 200 Hatfield, PA 19440 Phone: +1 215 822 7625 Fax: +1 215 822 7626 www.murrplastik.com cablemgmt@murrplastik.com China murrplastik Asia Co., Ltd. 1003 Rm. no. 1 Fuxing zhong Rd. 200021 Shanghai Phone: +86 21 6390-0501 Fax: +86 21 6390-0508 www.murrplastik.com.cn info@murrplastik.com.cn 89 03 87 4005 / 07-2005