VIA RAID configurations



Similar documents
VT8237 SATA RAID User Manual

English. Configuring SATA Hard Drive(s)

Intel ESB2 SATA RAID Setup Guidelines

Guide to SATA Hard Disks Installation and RAID Configuration

Guide to SATA Hard Disks Installation and RAID Configuration

NVIDIA RAID Installation Guide

Table of Contents. Configuring IDE RAID Hard Drive(s) (Controller GigaRAID (IT8212))... 2

RAID configuration and driver installation guide

VIA / JMicron RAID Installation Guide

Guide to SATA Hard Disks Installation and RAID Configuration

RAID installation guide for ITE8212F

Guide to SATA Hard Disks Installation and RAID Configuration

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

VIA RAID Installation Guide

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Guide to SATA Hard Disks Installation and RAID Configuration

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

How To Set Up Your Motherboard With A Power Supply And Power Supply On A Microtower 2.2 (Ios) With A Hard Disk Drive On A Mini Usb 2.3 (I386) With An External Hard Disk (I2)

How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (

SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3

AMD RAID Installation Guide

AMD RAID Installation Guide

PCI SATA + PATA Raid Card

Guide to SATA Hard Disks Installation and RAID Configuration

Serial ATA RAID PCI. User's Manual

Serial ATA ( ULi M1573)... 2

Ultra ATA 133 RAID PCI Pro

LSI Software RAID Configuration Utility

RAID installation guide for Silicon Image SiI3114

User manual Ver: 2.0. SATA Channel PCI RAID Card

ITE RAID Controller USER MANUAL

Encore SATA2 RAID PCIe Card


AMD RAID Installation Guide

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

SATA II 4 Port PCI RAID Card RC217 User Manual

Promise FastTrak 100-Lite RAID Controller

PCI ATA 133 RAID Controller Card. User Manual

Low Profile Ultra ATA-133 RAID PCI Host

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

The motherboard supports the following SATA RAID solutions:

Serial ATA RAID PCI Card

ESATA PCI CARD. User s Manual

Hard Disk Drives and RAID

GigaRAID (IT8212) ATA RAID Controller USER S MANUAL

ForceWare Software NVIDIA RAID User s Guide. Version 2.0 A

EX Port SATA3 RAID/HyperDuo PCIe(x2) Card

Serial ATA 4-Channel RAID Quick Installation Guide

Intel Matrix Storage Manager 8.x

VAIO Computer Recovery Options Guide

VIA Fedora Linux Core 8 (x86&x86_64) VT8237R/VT8237A/VT8237S/VT8251/CX700/VX800 V-RAID V3.10 Driver Installation Guide

Using ATI Array Management Software (WebPAM)

6-Port SATA II 150 PCI Host Card w/raid

4+1 SATA II 300 IDE/PATA PCI-E. Combo Host Card w/ RAID & Port. Multiplier

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

RocketRAID User's Manual. Revision: 1.0 Date: Mar HighPoint Technologies, Inc.

RAID Option Installation

Table of Contents 1. INTRODUCTION TO THE DC-200 RAID CARD... 3

ForceWare Software MediaShield User s Guide. Version 5.0

4-1-4 Serial ATA SATA. A. Intel ICH8R (1) SATA (1) SATA (2) BIOS SATA (3) RAID BIOS RAID (4) SATA (5) SATA

Addonics. 4-Port External SATA II PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-E) User s Guide Revision 1.1 T E C H N O L O G I E S

RAID installation guide

4 Port PCI SATA RAID Controller Adapter Card

PCI SATA Controller Card Model: SY-PCI40010

SATARAID5 Serial ATA RAID5 Management Software

Intel Rapid Storage Technology

SATA II PCIe RAID Quick Installation Guide

Intel ICH5R Serial ATA RAID. Quick User s Guide

Serial-ATA IDE Card. Version 1.0

Configuring ThinkServer RAID 100 on the TS140 and TS440

SATA RAID SIL 3112 CONTROLLER USER S MANUAL

46xx_47xx_1546_1547 RAID Recovery/Set Up Instructions

Intel PCH RAID Configuration Utility

Promise RAID Function

IDE2410 ATA-100 IDE RAID Card. Version 1.0

SATA 150 RAID. user. Model MAN UM

Intel ICH7R/ICH9R HostRAID Setup Guidelines

RAID Utility for Windows

ATA-133 IDE RAID Card. Version 1.1

RAID OPTION ROM USER MANUAL. Version 1.6

SATA II PCIe RAID Quick Installation Guide

Serial ATA 2 Ports PCI Host

SATARAID5 Serial ATA RAID5 Management Software. Users Manual

RocketRAID User, s Manual. Revision: 1.0 Date: Sept HighPoint Technologies, Inc.

SBI-7125B-T1 Blade Module RAID Setup Procedure

SATA RAID Function. (Only For Chipset Sil 3112 /Sil 3512 Used) USER S MANUAL 12M E-SI

UltraATA 100 PCI RAID TM

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Advanced Host Controller Interface (AHCI) and Redundant Array of Independent Disks (RAID) on HP Compaq dc5850 Business PCs

Marvell SATA3 RAID Installation Guide

Configuring ThinkServer RAID 100 on the Lenovo TS130

Setting up SATA RAID on the HP xw4600, xw6600, and xw8600 Workstations

Transcription:

VIA RAID configurations The motherboard includes a high performance IDE RAID controller integrated in the VIA VT8237R southbridge chipset. It supports RAID 0, RAID 1 and JBOD with two independent Serial ATA channels. RAID 0 (called Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup. RAID 1 (called Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive. JBOD (Spanning) stands for Just a Bunch of Disks and refers to hard disk drives that are not yet configured as a RAID set. This configuration stores the same data redundantly on multiple disks that appear as a single disk on the operating system. Spanning does not deliver any advantage over using separate disks independently and does not provide fault tolerance or other RAID performance benefits. If you use either Windows XP or Windows 2000 operating system (OS), copy first the RAID driver from the support CD to a floppy disk before creating RAID configurations. 1 Installing hard disks The motherboard supports Ultra DMA 133/100/66/33 and Serial ATA hard disk drives. For optimal performance, install identical drives of the same model and capacity when creating a disk array. Installing Serial ATA (SATA) hard disks To install the SATA hard disks for a RAID configuration: 1. Install the SATA hard disks into the drive bays. 2. Connect the SATA signal cables. 3. Connect a SATA power cable to the power connector on each drive.

2 VIA RAID configurations The motherboard includes a high performance IDE RAID controller integrated in the VIA VT8237R PLUS southbridge chipset. It supports RAID 0 and RAID 1 with two independent Serial ATA channels. Setting the BIOS RAID items After installing the hard disk drives, make sure to set the necessary RAID items in the BIOS before setting your RAID configuration. To set the BIOS RAID items: 1. Boot the system and press <Del> during the Power-On Self-Test (POST) to enter the BIOS Setup Utility. 2. From the Integrated Peripherals > OnChip Device Function, then Set the SATA Operation Mode item as Enabled (or select RAID Mode). 3. Save your changes and exit Setup. Entering the VIA Tech RAID BIOS Utility 1. Boot up your computer. 2. During POST, press <Tab> to enter VIA RAID configuration utility. The following menu options will appear. Create Array The RAID BIOS setup screens shown in this section are for reference only, and may not exactly match the items on your screen. From the VIA RAID BIOS utility main menu, select Create Array then press <Enter>. The main menu items on the upper-left corner of the screen are replaced with create array menu options. VIA Tech. VT8237 Series SATA RAID BIOS Ver x.xx Auto Setup For Data Security Array Mode RAID 1 (Mirroring) Select Disk Drives Start Create Process Create a RAID array with the hard disks attached to VIA RAID controller F1 : View Array/Disk Status, : Move to next item Enter : Confirm the selection ESC : Exit Channel Drive Name Array Name Mode Size(GB) Status Serial_Ch0 Master XXXXXXXXXXX ARRAY 0 SATA 999.99 XXXXXXX Serial_Ch1 Master XXXXXXXXXXX ARRAY 0 SATA 999.99 XXXXXXX Motherboard

RAID 0 for performance 1. From the create array menu, select Array Mode, then press <Enter>. The supported RAID configurations appear on a pop-up menu. RAID 0 for performance RAID SPAN for capacity 2. Select RAID 0 for performance then press <Enter>. From this point, you may choose to auto-configure the RAID array by selecting Auto Setup for Performance or manually configure the RAID array for stripped sets. If you want to auto-configure, proceed to the next step, otherwise, skip to step 5. 3. Select Auto Setup for Performance and press <Enter>. The following confirmation message appears. Auto create array will destroy all data on disks, Continue? (Y/N) 4. Press <Y> to confirm or <N> to return to the configuration options. If you selected <Y>, proceed to step 9. 5. Select Disk Drives, then press <Enter>. Use arrow keys to select disk drive, then press <Enter> to mark selected drive. An asterisk appears before a selected drive. 6. Select Block Size, then press <Enter> to set array block size. A list of valid array block sizes are displayed on a pop-up menu. 4K 8K 16K 32K 64K TIP: For server systems, use of a lower array block size is recommended. For multimedia computer systems used mainly for audio and video editing, a higher array block size is recommended for optimum performance. Use arrow keys to move selection bar on items and press <Enter> to select. 7. Select Start Create Process and press <Enter> to set up hard disk for RAID system. The following confirmation message appears: The data on the selected disks will be destroyed. Continue? (Y/N) 8. Press <Y> to confirm or <N> to return to the configuration options. 9. Press <Esc> to go back to main menu.

1. From the create array menu, select Array Mode, then press <Enter>. The supported RAID configurations appear on a pop-up menu. RAID 0 for performance RAID SPAN for capacity 2. Select then press <Enter>. 3. From this point, you can auto-configure the RAID array by selecting Auto Setup for Data Security or manually configure the RAID array for mirrored sets. If you want to auto-configure, proceed to the next step, otherwise, skip to step 6. 4. Select Auto Setup for Data Security and press <Enter>. The following confirmation message appears. Auto create array will destroy all data on disks, Continue? (Y/N) 5. Press <Y> to confirm or <N> to return to the configuration options. If you selected <Y>, proceed to step 11. 6. Select Select Disk Drives, then press <Enter>. Use arrow keys to select disk drive/s, then press <Enter>. An asterisk appears before a selected drive. 7. Select Start Create Process and press <Enter> to setup hard disk for RAID system. The following inquiry appears: Save the data on source disk to mirror after creation? (Y/N) 8. If you select <Y> the utility will duplicate your data. Press <Y> anytime if you want to exit the duplication process. Duplicating... Press CTRL+E to Escape 9. If you select <N>, the following confirmation message appears. The data on the selected disks will be destroyed. Continue? (Y/N) 10. Press <Y> to confirm or <N> to return to the configuration options. 11. Press <Esc> to go back to main menu. Motherboard

Creating a RAID driver disk A floppy disk with the RAID driver is required when installing Windows 2000/XP operating system on a hard disk drive that is included in a RAID set. You can create a RAID driver disk using your motherboard support CD. To create a RAID driver disk: 1. Insert the motherboard support CD into the CD-ROM drive. 2. When the Drivers menu appears, click RAID Driver Disk to creat a VIA 8237 RAID PLUS Driver Disk. 3. Insert floppy disk to floppy disk drive. 4. Follow succeeding screen information to complete process. 5. Write-protect the floppy disk to avoid computer virus infection. To install the RAID driver: 1. During the OS installation, the system prompts you to press the F6 key to install third-party SCSI or RAID driver. 2. Press <F6> then insert the floppy disk with RAID driver into the floppy disk drive. 3. Follow the succeeding screen instructions to complete the installation. 3