5235 Single Phase Credit Meter

Similar documents
Polyphase kwh Electricity Meter

E350 series 2. Electricity Meters IEC/MID Residential. ZxF100Ax/Cx. User Manual

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter

Single Phase Magnetic Card Electricity Meter

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

Energy Management Energy Meter Type EM23 DIN

Elster Metering Systems. EC Directive 2004/22/EC

Solid state single phase meter User manual

MOUNTING AND OPERATING INSTRUCTIONS

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

A project to optimise quality and energy efficiency must include metering

3-phase, bidirectional energy meter

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Applications. diris_826_a_1_gb_cat

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

TMS TANK MANAGEMENT SYSTEM

CODE OF PRACTICE NINE

The multi-functional integrator Supercal 531

Quick Connect. quick - simple - efficient.

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

GTEC transfer switch open transition

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Maximum Demand Control

3-Phase Energy meter with serial S-Bus interface

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Emergency lighting units EM powerled

DLP-PU/E Instruction Manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Application/Connection Examples

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

R.C.C.B. s two-pole LEXIC

WD-AMX Water Detection Controllers

What is a multimeter?

Installation and operating instructions

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

HYDRUS ULTRASONIC METER

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Safety Manual BT50(T) Safety relay / Expansion relay

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Power Meter Series 700

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Talon and Talon SR User Manual

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Adjustment functions for both span and shift have been incorporated

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

MCR1900 Media Converter 19-Slot Chassis

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

UM-X Field display for continous level sensors

Instructions for Safe Use

Water Leak Detection System

Series 510 Submersible Level Transmitters

Manual Ranging MultiMeter

Wolflite Safety Handlamp H-251E

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Duct Humidity Transmitter

Ground Resistance Clamp On Tester

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Three-phase monitoring relay CM-PFE

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

T5000 T000 LCD Digital Fan Coil Thermostat

AC-115 Compact Networked Single Door Controller. Installation and User Manual

User's Guide. True RMS Industrial Multimeter

Flexible Counter Series in DIN size 24 x 48 mm

Cable Plug acc. to DIN EN , Form A

HERZ-Thermal Actuators

Installation guide H A. HSI hardwired system interface

WIRELESS MAGNETIC CONTACT

Current Probes. User Manual

Digital input modules

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Safety technique. Emergency stop module BO 5988 safemaster

B21 User Manual Document ID: 2CMC485004M0201 Revision: A

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

AutoRanging Digital MultiMeter

Problem / Solution. The problem:

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

GenStore Archive Cabinet

Safety automation solutions

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

THERMAL ENERGY METER MC 108/ET

Digital Keypad Use s Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

CURRENT TRANSFORMERS INSTALLATION GUIDE

Catalog. Arc Guard System TM TVOC-2

Transcription:

Electricity Meters Residential BS / IEC British Standard 5235 Single Phase Credit Meter User Manual & Technical Specification Date: 20/11/08 Filename: 5235 User Manual Q Pulse No:IB047 Landis+Gyr

Page 2 of 21 Issue: 4 5 Revision History Issue Date Comments 1. 10/10/04 New document 2. 10/01/05 Added section on the No power read and Appendix B. Added Document number. 3. 01/11/05 Added new amendments 4. 15/02/06 Added D-L version removed F version (reactive energy still needs adding) 5. 18/11/08 Revised manual to new branding guidelines and layout Copyright notice The material in this document is the property of Landis+Gyr. Our products are under continual improvement and we reserve the right to make changes without prior notice Landis+Gyr 1 Lysander Drive, Northfields Industrial Estate, Market Deeping, Peterborough PE6 8FB www.landisgyr.com Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

Table of Contents Issue: 4 Page 3 of 21 Table of Contents 1 Introduction 5 1.1 Purpose 5 1.2 Meter Overview 5 1.3 Model versions 5 1.4 Reference Standards 5 1.5 20 Year Certification Life 5 2 Safety Information 7 2.1 Responsibilities 7 2.2 Safety Regulations 7 3 Operational Functions 9 3.1 Measurement 9 3.2 Anti creep 9 3.3 Meter Memory 9 3.4 Reverse / Export Energy registration 9 4 User Interfaces 11 4.1 Register Displays 11 4.2 Pulsed Output (Option) 11 4.3 Switching inputs (D model) 11 5 Installation 13 5.1 Construction 13 5.2 Meter fixing 13 5.3 Wiring 13 6 Technical Summary 15 6.1 Technical Summary 15 6.2 Dimensions 16 7 Maintenance and Service 17 7.1 Meter Check 17 7.2 Meter Testing 17 7.3 Post Installation Configuration Changes 17 8 Measures in the Event of Faults 18 8.1 Operating Faults 18 8.2 Disconnecting the Meter 18 8.3 Repairing the Meter 18 9 Decommissioning and Disposal 20 10 Glossary of Terms and Standards 21 10.1 Acronyms 21 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr

Page 4 of 21 Issue: 4 5 Table of Contents 10.2 Measurement Units 21 Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

Introduction Issue: 4 5 Page 5 of 21 1 Introduction Introducing the 5235, single and multi-rate tariff options, Single Phase BS Standard Credit Meter 1.1 Purpose This document details the functions for the following variants of the 5235 Single Phase Credit Meters, active energy only. Single Rate, kwh meter Single Rate, kwh meter with class A pulse output Multi-rate Externally switched meter 1.2 Meter Overview 1.3 Model versions 1.4 Reference Standards The meter is a whole current static electricity meter capable of measuring kwh in single and two rate variants. An additional option to have a pulsed output is also available on the single rate version. The meter is approved to IEC62052 11: 2003 & IEC62053 21:2003 classes 1.0 and 2.0 and has been given a 20 year certification life by OFGEM. The meter is sealed for life by a liquid welding process and therefore does not carry an external wire seal. All meter types feature an optical port used for reprogramming. The metrology LED is incorporated into this port and pulses at a rate of 1000 impulses per kwh. All facia details are permanently laser etched directly onto the meter front. Options would normally include property details, serial numbering and various barcode options. Other details may be printed such as customer logo s and meter type codes etc. A character denotes meter version after the model number: A - Single rate only active only 1.5 20 Year Certification Life B - Single rate with pulsed output active only D - Externally switched two-rate active only The meter has been tested by OFGEM and has the following certification. IEC62052 11: 2003. IEC62053 21:2003. Alternating current static watt-hour meters for active energy (Classes 1 & 2). Other standards are in the technical summary. This meter has been given a certification life of 20 years by OFGEM the UK regulatory body. This has been achieved by proving the reliability of each of the components in the meter and by using mathematical models provided 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr

Page 6 of 21 Issue: 45 Introduction by OFGEM. This modelling has shown a reliability of better than 97% over twenty years. The OFGEM approval number for this meter is 986. OFGEM certificates and lifetime reports are available upon request. Please contact sales@landisgyr.com Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

Safety Information Issue: 4 5 Page 7 of 21 2 Safety Information Attention is drawn as follows in the individual chapters of this user manual with classified word symbols and pictographs to the relevant danger level, i.e. the severity and probability of any danger: Definition of Danger This symbol is used to indicate a possibly dangerous situation which could result in severe physical injury or a fatality. Definition of Warning This symbol is used to indicate a possibly dangerous situation which could result in minor physical injury or material damage. Definition of Note This symbol is used to indicate general details and other useful information. 2.1 Responsibilities 2.2 Safety Regulations In addition to the danger level, all safety information also describes the type and source of the danger, it s possible consequences and measures to counteract the danger. The owner of the meters normally the utility is responsible that all persons engaged on work with meters: Have read and understood the relevant sections of the user manual. Are sufficiently qualified for the work to be performed. Strictly observe the safety regulations (according to section 1.6) and the operating information in the individual chapters. In particular, the owner of the meters bears responsibility for the protection of persons, prevention of material damage and the training of personnel (Landis+Gyr. provides training courses for this purpose on specific equipment; please contact the relevant agent if interested). The following safety regulations must be observed at all times: This equipment does not contain a disconnection device. Means for disconnection from the supply must be provided as part of the building installation. Do not work on the equipment unless the 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr

Page 8 of 21 Issue: 45 Safety Information supply is disconnected. If disconnection is done by removal of fuses or other cut-outs, the removed disconnection devices must be kept secure from replacement while work is performed. If disconnection is provided by a switch, the switch shall conform to the requirements of IEC 947-1 and IEC 947-3 or equivalent. This equipment does not contain an overcurrent protection device. Overcurrent protection must be provided as part of the building installation. Maximum overcurrent device rating is 100 Amp at 415 Volts, conforming to the requirements of BS1361, or equivalent. The maximum rating of the meter is 100A and requires connecting conductors of 25mm 2. Failure to do so could result in irreparable damage to the meter. If smaller connecting conductors are used an appropriate mains fuse must be used. Only suitably trained and qualified personnel shall be allowed to work on the equipment. Local safety standards shall be observed and shall take precedence over these regulations in points of conflict. The meters must be held securely during installation. They can cause injuries if dropped. Meters that have fallen must not be installed, even if no damage is apparent, but must be returned for testing to the service and repair department responsible (or the manufacturer). Internal damage can result in functional disorders or short-circuits. The meters must on no account be cleaned with running water or with high-pressure devices. Water penetrating can cause shortcircuits. The meter terminal cover should be secured in place before any load is supplied. Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

Operational Functions Issue: 4 5 Page 9 of 21 3 Operational Functions 3.1 Measurement The standard operational functions of the 5235 The Meter is a 120V or 220-240Vac, 50Hz or 60Hz, 5 to 100A Single Phase Credit Meter. It contains a measuring element capable of measuring active energy (kwh). The meter measures and registers kwh up to class 1.0. accuracy. The metrology LED is incorporated into the optical port and pulses at a rate of 1,000 impulses per kwh for energy registration. All variants offer a test mode, which shows 3 decimal places and is reset when voltage is removed. 3.2 Anti-creep Below starting current, the meter enters into an anti-creep mode. In this state the metrology LED is permanently lit and the registers do not increment. The LED remains lit until the meter current is increased in a forward direction beyond the starting current. The starting current is shown in the technical summary. 3.3 Meter Memory All the meters data is to be recorded in a Ferroelectric Random Access Memory (FRAM) under the control of the microprocessor. All the kwh registers are stored in the FRAM and will be updated periodically and on power-fail. The FRAM is able to be re-written throughout the life of the meter and will hold the information, if required for over twenty years. 3.4 Reverse / Export Energy registration Three factory configurable reverse energy modes can be set as follows: Export Energy Registration A reverse / export energy register stores the value of kwh recorded by the meter in a reverse direction. The register may be configured as part of the display cycle of the meter. Alternately the register is held in memory and can be read from the meter via the IEC 1107 port. The Reverse energy register can be displayed with 0, 1 or 2 decimal places. Export energy will be recorded in the same way as forward (Import) flowing energy using identical starting currents etc. A F B E C D Total Reverse Reverse Energy Detection A configurable option within the meter will alternate a warning message on the display should a fraud attempt be made by running current backwards 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr

Page 10 of 21 Issue: 45 Operational Functions through the meter. The reverse energy warning message is triggered when the reverse power exceeds a programmable threshold level of between 1-10 Amps for a period of 10Wh. Once this level is reached the message below will be displayed which can only be reset via the IEC 1107 port. Whilst in this mode the LED will remain lit whilst there is reverse energy detected. Reverse Energy Detection Message Unidirectional Register An optional requirement is to accumulate both import and export energy into the same register. Basically this will be the sum of adding both forward and reverse energy resisters. The register would be shown as the normal kwh display as below: A F B E C D Total Display No Power Read (option) This allows the user to take meter readings when there is no mains electricity supply. This is achieved by installing a battery supply board that powers the meter. The user applies a magnet to the outside of the meter case and the meter powers up for 20 to 30 seconds. During this time the meter displays the sign on and then displays the energy registers. Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

User Interfaces Issue: 4 5 Page 11 of 21 4 User Interfaces 4.1 Register Displays The inputs and outputs of the 5235 Single rate version -versions A & B Single rate meters display the total kwh reading only. The display is configurable to show either whole numbers, 1 or 2 decimal places. The meter is also factory configurable to display either 5 or 6 digits with roll over to zero at 99999 or 999999. Two-rate meter (external time switch) - D version only kwh are recorded at a particular rate and displayed using the rate enunciators on the left hand side of the display. The rate registers are displayed between 0 and a maximum of 2 decimal places unless configured to 3 decimal places of testing purposes via the optical port. The rate register range is 00000.00 99999.99 kwh unless factory configured to six digits. The diagram shows a display sequence for a fourrate meter and total register below. In the two rate variant the meter may be configured to operate between 1 and 2 rates via the Optical port. Rate 1 display. Flashing enunciator indicates active rate A F B E C D Rate 2 Display 4.2 Pulsed Output (Option) 4.3 Switching inputs (D model) The type B meter has an optically isolated, voltage free open collector Pulse Output that is configurable to between 1 and 1000 pulses per kwh. To maximise operation with external monitoring devises, the pulse width can also be configured to between 20 and 260 ms in 20 ms steps. Configuration is made through the IEC 1107 port. The output meets IEC62053-31: 1998 Class B, Maximum voltage 15Vdc. The configuration is factory set allowing the meter to operate as a single or two rate meter. Rate switching is achieved by switching neutral or live to the input terminal. See wiring diagram for the D model. 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr

Page 12 of 21 Issue: 45 User Interfaces 5235D-L Live switching model 5235D-N Neutral switching model Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

Installation Issue: 4 5 Page 13 of 21 5 Installation 5.1 Construction Construction, Mounting and wiring of the 5235 The Credit Meter case meets the requirements of BS5685 and is manufactured from following materials: - Meter Base: Meter Top: Terminal Cover: Terminals: Flame Retardant and UV stabilised Polycarbonate Flame Retardant and UV Stabilised Polycarbonate Flame Retardant and UV Stabilised Polycarbonate Solid Brass extrusion, 8.3mm diameter with 2 screws 5.2 Meter fixing 5.3 Wiring The meter is mounted using the two fixing holes found either side of the terminal housing. To aid terminal cover sealing, the screw boss has four raised indicators that should be aligned against the indicator on the cover. Terminal arrangement conforms to BS5685, Part1, 1979. Wiring diagrams can be put onto the terminal covers of the meters. Meter Element L Supply N Meter type 5235 A and F L Load N Wh Meter Element L Supply N Meter type 5235 B L Load N 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr

Page 14 of 21 Issue: 45 Installation Meter Element Time switch L Supply N Meter type 5235 D - N L Load N Meter Element Time switch L Supply N Meter type 5235 D L L Load N Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

Technical Summary Issue: 4 5 Page 15 of 21 6 Technical Summary 6.1 Technical Summary The technical specifications of the 5235 System Voltage Single element meters 240Vac Phase to Neutral 230Vac Phase to Neutral 220Vac Phase to Neutral 210Vac Phase to Neutral Supply variation +15% to -20% Voltage withstand 415V continuous 10kV impulse @105J Current (Base) Direct connection Ib 5A, 10A, or 20A Current (Max) Imax 40A, 60A, 80A or 100A Starting Current (IEC) 0.4% of Ib Max measuring range 20mA up to 100A Measuring Accuracy IEC 62053-21 Class 1 and 2 Burdens Voltage Circuit @ 230Vac 0.9W 7.7VA Current Circuit @ Ib 0.1VA Supply Frequency Nominal 50Hz or 60Hz Frequency Variation +/- 5% Temperature Range Limit operating ranges -20 C to 55 C Storage range -25 C to 70 C Meter Constant 1000 imp/kwh Pulse output The output meets IEC62053-31: 1998 Class B, Maximum voltage 15Vdc Display Type 7 character, 7segment LCD Character size 83.5 mm. Quality Manufactured to: ISO 9001:1994 Ofgem approval number 986 Certificated life 20 years Reference standards IEC62052 11: 2003 & IEC62053 21:2003 Alternating current static watt-hour meters for active energy. (Classes 1 & 2) BS5685: 1979: Part 1:Specification class 0.5, 1.0 and 2.0 Single phase and Polyphase, single rate and multi-rate watt-hour meters. IEC62056 21: 2002.Data Exchange for Meter Reading, Tariff and Load Control. Direct Local Exchange. SI1566: 2003The Meters (Certification) Regulations 1990. Construction Flame Retardant and UV Stabilised Polycarbonate Terminal arrangement BS5685 Terminal size 8.3 mm diameter. Weight Standard Terminal Cover 304g Extended Terminal Cover 338g Dimensions (mm) Standard Terminal Cover H 80 x W 125 x D 36 Extended Terminal Cover H 113 x W 126 x D 41 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr

Page 16 of 21 Issue: 45 Technical Summary 6.2 Dimensions Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

Maintenance and Service Issue: 4 5 Page 17 of 21 7 Maintenance and Service 7.1 Meter Check 7.2 Meter Testing While it isn t necessary, under normal circumstances, to perform any maintenance on the installed meter, the following are check points that should be observed during scheduled periodic meter visits. Is the meter dry and clean, particularly the LCD display and the optical interface? Does the meter display a legible and sensible display? i.e. does the meter appear in a serviceable condition. Check all factory fitted and company fitted seals are in place secure and intact. Observe display for any error messages or notifications Confirm that the energy registers have changed to a reasonable degree since the last visit. If irregularities are found, continue as in section 8. The testing of meters, either random sample or on all meters, should be carried out periodically according to national regulations. The meter must be removed as described in section 8.3 and replaced with a meter of similar type for the duration of the tests. 7.3 Post Installation Configuration Changes With the aid of a laptop computer or other suitable hand held device a flag probe and Landis+Gyr specific software, it is possible to amend the factory configured options of the meter. It is beyond the scope of this manual to describe in any further detail the procedure. Landis+Gyr sales team would be happy to discuss specific requirements. 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr

Page 18 of 21 Issue: 45 Measures in the Event of Faults 8 Measures in the Event of Faults 8.1 Operating Faults 8.2 Disconnecting the Meter If the LCD window is illegible or the data readout does not function, the following points should be checked. Is the mains voltage present? Are the preliminary fuses intact? Has the minimum or maximum recommended ambient temperature been exceeded? Is the LCD window clear of all debris? Not misted over, painted over or soiled in any way. If none of the above are causing the fault the meter should be disconnected as per section 8.2, replaced if required as detailed in section 5 and returned to Landis+Gyr as described in section 8.3. Remove preliminary fuses before continuing The connecting conductors should not be Live when removing the meter. Electrically Live parts are a life threatening hazard. Preliminary fuses should be removed and kept in a safe place until all work is complete, where they cannot be replaced by anyone unnoticed. 8.3 Repairing the Meter Proceed as follows: Remove the company seal on the terminal cover (if fitted). Release the two terminal cover screws and remove terminal cover. Check with a suitable voltage testing device that the phase connections are not live. If they are live then remove the preliminary fuses and keep in a safe place until all work is complete, where they cannot be replaced by anyone unnoticed. Remove the signal inputs and outputs by releasing the auxiliary terminal screws. Remove the phase connections by releasing the main terminal screws. If required fit a suitable replacement meter as described in section 5. There are no user serviceable parts inside the meter. Breaking factory calibration seals will invalidate the calibration status of the meter. In the event of a meter requiring repair, proceed as follows. Remove the meter from the installation as detailed in section 8.2. Attach a label, which describes the fault as accurately as possible, to the meter and include name and contact details of person responsible in case of inquiries. Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

Measures in the Event of Faults Issue: 4 5 Page 19 of 21 Package the meter to ensure no further damage can occur during transit. Send the meter back to Landis+Gyr. 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr

Page 20 of 21 Issue: 45 Decommissioning and Disposal 9 Decommissioning and Disposal The procedure for the safe removal of the meter from the installation is described in section 8.3. Please ensure that ALL SAFETY PRECAUTIONS are met before proceeding. Based on the environmental certificate ISO 14001, the components used to manufacture the meter can, in the main, be broken down into constituent parts and sent for suitable recycling or disposal. The following are general guidelines and should NOT take priority over local disposal and environmental policies which should be adhered to without compromise. Component Parts Printed Circuit Boards LCD Display Metal Components Plastic Components Disposal Treated as per disposal of Electronic Equipment Sorted and delivered to collective recycling point Sorted and delivered for re-granulation if at all possible Landis+Gyr 5235 Single Phase Credit Meter User Manual & Technical Specification

Glossary of Terms and Standards Issue: 4 5 Page 21 of 21 10 Glossary of Terms and Standards 10.1 Acronyms Acronym BS DFS DIN ECD EEPROM IEC ISO LCD LED MD MID NPR OFGEM PTR RED Definition British Standard Direct Field Sensor Deutsches Institut für Normung (German Institute For Standardisation) External Connection Diagram Electrically Erasable Programmable Read Only Memory (E2) International Electrotechnical Commission International Standards Organisation Liquid Crystal Display Light Emitting Diode Maximum Demand Metering Industry Directive No Power Read The Office of Gas and Electricity Markets Photo-transistor Reverse Energy Detected 10.2 Measurement Units A Hz Iref Kg kvah kvarh kwh mm mo ms Nm o C UN UT V Ampere (unit of current) Hertz (unit of frequency) MID reference current Kilogramme (unit of weight) Kilo Volt Ampere hour kilo Volt Amps reactive hour kilo Watt-hour millimetre (unit of distance) milliohm (unit of resistance) millisecond Newton meter (unit of torque) Degree Celsius (unit of temperature) Rated supply voltage of meter Rated external switch voltage Volt 5235 Single Phase Credit Meter User Manual & Technical Specification Landis+Gyr