Surveyors name P/O No. U-71-1168 System Owner COA Pipeline Segment Reference 936 1614 Shape Circular H Rim to Invert RCP Sewer Category Grade to Invert Ln. Method Pre-Cleaning No PreCleaning Group/ Descriptor. ACB.. 6.6 9. 9. 1.1 1.1..8 4. 4. 47.3. 4.9 4.9 MWL OBZ LL MGO OBZ OBZ MGO TB TB LL ISSRL LR MMC MSC RPR JO MSA Modifier/ severity S/M/L Inches 1st nd S1 Use of Sewer Stormwater Sheet Joint Image Ref. At / From To 1 9 7 1 % Locality Grade to Invert Year Laid Rim to Grade Flow Control Year Rehabilitated Height Tape / Media Number 1-449_8 beginning inspection 4 of pipe 936 from inlet heading downstream to an unknown inlet named 1-449_UKGI_1 Circumferential Location Value Continuous defect Rim to Invert Rim to Grade Pipe Joint Length 8 Cleaned Code Distance (Feet) Location (Street Name and number) Upstream Manhole Number Manhole Number 1-449_UKGI_1 Drainage Area 1 1:6 Further Location details 119 Brazos St Width Survey Customer Struct. O&M Grade Grade Remarks beginning inspection 4 from ACB heading downstream to alley behind 11 Congress Ave grated inlet ACB1. Will relabel identifications. Pipe exits to the North. Will stop at 7' preset 4 continuing on from a 9' preset due to 9 degree turn. F1 7 7 new connections A A 9 3 9 1 1 1 S J L mastic pipe changes to non reinforced concrete pipe changes size from repair pipe is replaces with tube to repair causing offset joint pipe is offset at RPR abandoning inspection 8 due to failing patch repair Generated on Tuesday, 6/19/1 at 4:1 PM by the PipeTech TV inspection system.
Surveyors name P/O No. U-71-1168 System Owner COA Pipeline Segment Reference 936 1614 H Shape Circular Rim to Invert RCP Sewer Category Grade to Invert Ln. Method Pre-Cleaning No PreCleaning S/M/L Joint Image Ref. At / From % Year Laid Flow Control Year Rehabilitated Height Tape / Media Number 1-449_8 beginning inspection 4 of pipe 936 from inlet heading downstream to an unknown inlet named 1-449_UKGI_1 Circumferential Location Inches 1st nd Rim to Grade Struct. O&M Grade Grade To Remarks Segment Grade Rating Quick Index Grade 1 Grade Grade 3 Grade 4 Grade Rating Quick Index Grade 1 Grade Grade 3 Grade 4 Grade Rating Quick Index Overall Grade 4 O&M Grade 3 Structural Grade Modifier/ severity Use of Sewer Stormwater Grade to Invert Grade 1 Group/ Descriptor Value Continuous defect Sheet Locality Rim to Invert Rim to Grade Pipe Joint Length 8 Cleaned Code Distance (Feet) Location (Street Name and number) Upstream Manhole Number Manhole Number 1-449_UKGI_1 Drainage Area 1:6 Further Location details 119 Brazos St Width Survey Customer 1-449_8 1. 8 4 14 414. 1 4 16 41. Generated on Tuesday, 6/19/1 at 4:1 PM by the PipeTech TV inspection system.
PACP Inspection Report MH 1-449_UKGI_1 U-71-1168 119 Brazos St 1614 1:6 beginning inspection 4 of pipe 936 from inlet heading downstream to an unknown inlet named 1-449_UKGI_1 Ftg. Code Description. ACB Access Point - Catch Basin Position Comment beginning inspection 4 from ACB heading downstream to alley behind 11 Congress Ave grated inlet ACB1. Will relabel identifications. Pipe exits to the North. Will stop at 7' preset. MWL Water Level. OBZ Obstacle - Other Objects 6.6 LL Line - Left to 7 9. MGO General Observation 9. OBZ continuing on from a 9' preset due to 9 degree turn. Obstacle - Other Objects to 7 1.1 OBZ Obstacle - Other Objects 1.1 MGO General Observation to 7..8 TBA TBA 4. LL new connections Tap, Break-in / Hammer: Active Tap, Break-in / Hammer: Active Line - Left 4. ISSRL Intruding Seal - Sealing Ring: Loose/Poorly Fitting 47.3 LR 9 3 9 to 1 mastic Line - Right. MMC Change pipe changes to non reinforced concrete 4.9 MSC Dimension/Shape Change 4.9 RPR Point Repair - Pipe Replaced pipe changes size from repair pipe is replaces with tube to repair causing offset joint pipe is offset at RPR abandoning inspection 8 due to failing patch repair JOL Joint Offset (displaced): Large MSA Survey Abandoned Generated on Tuesday, 6/19/1 at 4:1 PM by the PipeTech TV inspection system.
MH 1-449_UKGI_1 U-71-1168 119 Brazos St 1614 1:6 beginning inspection 4 of pipe 936 from inlet heading downstream to an unknown inlet named 1-449_UKGI_1 ACB - Access Point - Catch Basin @. ft. beginning inspection 4 from ACB heading downstream to alley behind 11 Congress Ave grated inlet ACB1. Will relabel identifications. Pipe exits to the North. Will stop at 7' preset OBZ - Obstacle - Other Objects @. ft. MWL - Water Level @. ft. LL - Line - Left @ 6.6 ft. Generated on Tuesday, 6/19/1 at 4:1 PM by the PipeTech TV inspection system.
MH 1-449_UKGI_1 U-71-1168 119 Brazos St 1614 1:6 beginning inspection 4 of pipe 936 from inlet heading downstream to an unknown inlet named 1-449_UKGI_1 MGO - General Observation @ 9. ft. continuing on from a 9' preset due to 9 degree turn. OBZ - Obstacle - Other Objects @ 1.1 ft. OBZ - Obstacle - Other Objects @ 9. ft. MGO - General Observation @ 1.1 ft. new connections Generated on Tuesday, 6/19/1 at 4:1 PM by the PipeTech TV inspection system.
MH 1-449_UKGI_1 U-71-1168 119 Brazos St 1614 1:6 beginning inspection 4 of pipe 936 from inlet heading downstream to an unknown inlet named 1-449_UKGI_1 TBA - Tap, Break-in / Hammer: Active @. ft. TBA - Tap, Break-in / Hammer: Active @.8 ft. LL - Line - Left @ 4. ft. ISSRL - Intruding Seal - Sealing Ring: Loose/Poorly Fitting @ 4. ft. mastic Generated on Tuesday, 6/19/1 at 4:1 PM by the PipeTech TV inspection system.
MH 1-449_UKGI_1 U-71-1168 119 Brazos St 1614 1:6 beginning inspection 4 of pipe 936 from inlet heading downstream to an unknown inlet named 1-449_UKGI_1 LR - Line - Right @ 47.3 ft. MMC - Change @. ft. pipe changes to non reinforced concrete MSC - Dimension/Shape Change @ 4.9 ft. pipe changes size from repair RPR - Point Repair - Pipe Replaced @ 4.9 ft. pipe is replaces with tube to repair causing offset joint Generated on Tuesday, 6/19/1 at 4:1 PM by the PipeTech TV inspection system.
MH 1-449_UKGI_1 U-71-1168 119 Brazos St 1614 1:6 beginning inspection 4 of pipe 936 from inlet heading downstream to an unknown inlet named 1-449_UKGI_1 JOL - Joint Offset (displaced): Large @ ft. pipe is offset at RPR MSA - Survey Abandoned @ ft. abandoning inspection 8 due to failing patch repair Generated on Tuesday, 6/19/1 at 4:1 PM by the PipeTech TV inspection system.