Royal Seal Gasketed Sewer Pipe



Similar documents
PVC Gasketed & Solvent Weld Pipe

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION POLYVINYL CHLORIDE (PVC) PIPE

ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

SECTION STORM DRAIN SYSTEM

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

DIVISION 4300 STORM DRAINAGE

INDEX. Sec. No. Items Page Nos.

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

PVC PIPE PERFORMANCE FACTORS

HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Gasketed PVC Sewer Pipe Durable, Flexible, Reliable Waterworks Products

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 21

Beacon Hill Sewer District Standard Specifications

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

Ultra-Rib PVC Storm Sewer Pipe 8" - 30"

SECTION STORM DRAINAGE TABLE OF CONTENTS

SECTION NONREINFORCED CONCRETE SEWER PIPE

Wastewater Capital Projects Management Standard Construction Specification

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

SANITARY SEWER SPECIFICATIONS

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

PREDICTING THE RESIDUAL LIFE OF PVC SEWER PIPES.

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

City of Edmonton Page 1 of 5 Foundation Drain Discharge Collection System Guideline November, 2005

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Section SEWER PIPE INSTALLATION AND TESTING

SECTION PRECAST CONCRETE UTILITY STRUCTURES

SECTION 5: SANITARY SEWER SYSTEM DESIGN

Gasketed Sewer Pipe and Fittings Installation Guide. Suitable for Gasketed Sewer Applications

Installation of Large Diameter Buried Pipes

Diamond LOK-21 Assembly Information

Pipes and Fittings for Gravity Sewer Mains. SewerMAX

CHAPTER 6 - SANITARY SEWER

Section 2100-Trenching and Tunneling

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Module 3: Sewer Material Lecture 3: Sewer Material

TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Module 3 : Sewer Material. Lecture 3 : Sewer Material

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

SECTION GRAVITY SANITARY SEWERS

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

725-R-599 PIPE LINING. (Revised ) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Drainage Solutions and Water Treatment / Single-wall corrugated drainage tubing is ideal for agricultural and. Durable Economical Wide range of sizes

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

Fabricated Drainage Products

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

MEMORANDUM: RECOMMENDATIONS FOR PIPE MATERIAL SELECTION

Green Thread Product Data

WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

September 2012 Brunswick County Engineering Department Revision 1.0. Technical Specification GRAVITY SANITARY SEWER SYSTEM

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

C. Section TESTING LABORATORY SERVICE.

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

TECHNICAL SPECIFICATION

TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

SPR PE Steel Reinforced Liner

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

Ridgistorm-XL - the latest innovative

Series 4000 Fiberglass Pipe and Fittings

ASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.

Flowtite Jacking Pipe

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Pipeline Replacement using Relining

pvc well casing & drop pipe

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Meets astm d3034 and astm f679. Building essentials for a better tomorrow

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

SECTION STORM DRAINAGE SYSTEM

Proposed Construction of Basement Flood Risk Assessment. 35 Edwardes Square London W8 6HH

AMERICAN Mechanical Joint Pipe For Water, Sewage or Other Liquids

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

OAR52 A-1 (September, 1981)

Exhibit A. Rules and Regulations for House Connections and Sewer Extensions

UNDERGROUND INFRASTRUCTURE SPECIALISTS TABLE OF CONTENTS

Section 402. STORM SEWERS

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

SECTION SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

Transcription:

Royal Seal Gasketed Sewer Pipe

Royal Seal Gasketed Sewer Pipe Royal Seal gasketed sewer pipe with our specially designed Double Seal Locked-In (DSLI ) gasket is an extremely durable pipe with a leak proof joint. The combination of chemical resistance, long term strength and high stiffness account for why PVC is the most popular pipe material for sanitary and storm sewer applications. Royal Seal gasketed sewer pipe can service the following applications: gravity storm and sanitary lines gravity industrial lines private drain connections Royal Seal gasketed sewer pipe proudly meets the following standards: certified to B182.2 D3034 F679 certified to CSA B182.2 OPS 1841 OPSD 806.040 NQ 3624-130 NQ 3624-135

Product Description Royal Seal gasketed sewer pipe is available in Standard Dimension Ratios (SDR) 28 and 35 in the following sizes: SDR 28 in 100-150mm (4-6"), SDR 35 in 100-675mm (4-27") and in 4 metre (13') lengths. The gasket is a Double Seal Locked-In (DSLI ) gasket that is installed during the manufacturing process. Royal Pipe Systems offers a complete line of fabricated and injection moulded fittings to complement our Royal Seal gasketed sewer pipe. There are many advantages for using our Royal Seal gasketed sewer pipe. Our pipe is corrosion resistant, durable and cost effective. Benefits Toughness and Durability Royal Seal gasketed sewer pipe is both tough and resilient, this pipe will not allow root penetration and will not be damaged by the impacts associated with normal field handling. Its resistance to abrasion, scouring and gouging is superior to that of other pipe materials. Royal Seal gasketed sewer pipe is corrosion resistant and not affected by sewer gasses, chemicals and hydrogen sulphide acids normally found in domestic sewer effluent or legally discharged industrial fluids. Smooth Interior Royal Seal gasketed sewer pipe has smooth interior walls with a Manning's coefficient "n" of 0.009 compared to 0.013 for concrete pipe. The resulting higher flow rates allow for the usage of small diameter pipe and flatter grades than would be possible with other pipe materials. System Integrity Royal Seal gasketed sewer pipe, when properly installed, helps to eliminate infiltration and leakage associated with the sewer system. Royal Seal gasketed sewer pipe joints are tested for joint tightness up to 345kPa (50psi) hydrostatic pressure. Our water tight joints help to eliminate costly extraneous flows entering the sewer system and contamination from leakage of the sewer systems. Biological Attack The performance of PVC pipe in severe environments has been studied since the 1930's. PVC pipe will not deteriorate or break down under biological attack from micro and macroorganisms. There has not been a single documented case in which buried PVC pipe products have suffered degradation or deterioration due to biological attack. Abrasion Based upon years of experience, PVC pipe has proven to have exceptional resistance to abrasion. Studies in Europe and North America have established PVC pipe's abrasion resistance. While the testing methods have varied substantially, the results have been consistent. The nature and resiliency of PVC pipe cause it to gradually erode over a broad area rather than develop the characteristic localized pitting and rapid failure of most other piping materials.

Product Quality The time and expense Royal Pipe Systems dedicates to product quality is part of our continuing commitment to providing our customers with the best products available. Royal Pipe Systems is recognized for its high quality products. Our state-of-the-art extrusion equipment and computerized material handling system ensure consistency. Our quality control testing guarantees that the pipe you install will outperform the application. In Royal's extrusion facilities, each operator is responsible for quality. Our operators check the wall thickness and outside diameter of every length of pipe produced. Every two hours, random samples are cut from the production line and sent to our quality control laboratory for testing in accordance with CSA and ASTM requirements. No pipe enters our yard without the seal of approval from our quality control team. PVC Material The PVC material used in the manufacture of our pipe meets the physical properties of PVC class 12454 as specified in ASTM D1784. DSLI GASKET SYSTEM Royal Pipe Systems uses the Double Seal Locked-In (DSLI ) Gasket System on our Royal Seal gasketed sewer pipe. This gasket joint is the most reliable in the marketplace. One of the most critical components of a sewer system is the integrity of the gasketed joint. For this reason, Royal Pipe Systems has chosen the highest quality gasket seal available. Our factory installed elastomeric gaskets create a joint that has a superior seal. There is no need to worry about the gasket twisting or flipping when the spigot end of the pipe is inserted. The patented Double Seal Locked-In (DSLI ) gasket provides two major benefits: 1. The Double Seal gasket increases joint tightness with an increase of pressure. 2. The patented steel reinforced Locked-In gasket provides an error-free installation preventing fall-out, rollover or fish mouthing, even when joining under adverse conditions. Nitrile gaskets available upon request.

Quality Control & Assurance Royal Seal gasketed sewer pipe undergoes extensive testing and inspection in our manufacturing facilities. The following testing assures outstanding product quality. Impact Resistance Test Samples of pipe to be tested for low temperature impact resistance are conditioned at 0 C (±2 C) for a period of at least 16 hours. After conditioning, five samples are tested in accordance with the values shown in the table below. There shall be no evidence of shattering, cracking or splitting of the wall when the pipe is tested in accordance to CSA B182.2. Joint Tightness Test Elastomeric gasket joints made with pipe and fittings or with bell end of pipe meet the requirements of ASTM D3212, except that the internal hydrostatic pressure shall be 100kPa (15psi) which exceeds the internal hydrostatic pressure of 74kPa (11psi) as stated in the ASTM D3212 Standard. Nominal Pipe Size Impact Force J (ft lb) 100 (4) 135 (100) 135 (5) 150 (111) 150 (6) 165 (122) 200 (8) 175 (129) 250 (10) 190 (140) 300 (12) 205 (151) 375 (15) 230 (170) 450 (18) 275 (203) 525 (21) 300 (221) 600 (24) 300 (221) 675 (27) 300 (221) Compression Test Three specimens of the pipe, each about 50mm (2") long are flattened between parallel plates in a suitable press until the distance between the plates is 40% of the original outside diameter of the pipe. The rate of loading is uniform and the compression is completed within 2 to 5 minutes. Upon removal of the load, the specimens are examined for evidence of splitting, cracking or breaking. This test methodology is in accordance with CSA B182.2. Extrusion Quality Test Specimens shall be tested in accordance with ASTM D2152. The pipe will not flake or disintegrate after being immersed in anhydrous acetone for 20 minutes. Pipe Stiffness The minimum pipe stiffness for SDR 28 pipe shall be 625kPa (90psi) and for SDR 35 pipe 320kPa (46psi), when tested at 5% deflection in accordance with ASTM D2412.

Installation Royal Seal gasketed sewer pipe weighs a fraction of the weight of traditional pipe products, therefore handling and installation costs are reduced substantially. Our pipe can be easily cut in the field and the joint assembly can be handled in the trench without using heavy equipment. Joining Both bell and spigot shall be clean of all debris. Lubricant must be applied to the spigot end of the pipe (do not lubricate the gasket). The pipes are then placed in straight alignment, push the spigot into the bell to the insertion line marked on the pipe. Pipe assembly can be completed by hand using a bar and block, lever pullers or hydraulic jacks. Royal's factoryinstalled gaskets eliminate the problems of rolling or fish mouthing. Care should be taken to avoid over insertion into the pipe bell beyond the spigot insertion line. Fittings Royal Pipe Systems carries a complete line of fabricated and injection moulded fittings to complement our Royal Seal gasketed sewer pipe. Our fabricated fittings are third-party certified to the CSA B182.2 Standard and our injection moulded fittings are certified to CSA B182.1. Lubricant Royal Seal gasketed sewer pipe must be assembled with Royal non-toxic, water-soluble lubricant which is listed by the National Sanitation Foundation (NSF). Colour Coding Royal Seal SDR 35 gasketed sewer pipe is colour coded green. Royal Seal SDR 28 gasketed sewer pipe is available in green and white. Fabricated fittings are green and injection moulded fittings are white. Royal Pipe Systems provides an INSTALLATION GUIDE with detailed recommendations on pipe handling, assembly and testing of Royal Seal gasketed sewer pipe and fittings. Ask your sales representative or distributor for a copy.

Dimensions Standard Dimension Ratio (SDR) SDR 28 SDR 35 Nominal Size Average Inside Diameter Average Wall Thickness Average Outside Diameter 100 (4) 99 (3.899) 4 (0.158) 107 (4.215) 135 (5) 133 (5.218) 5 (0.211) 143 (5.640) 150 (6) 147 (5.799) 6 (0.238) 159 (6.275) 100 (4) 101 (3.957) 3 (0.129) 107 (4.215) 135 (5) 135 (5.298) 4 (0.171) 143 (5.640) 150 (6) 149 (5.893) 5 (0.191) 159 (6.275) 200 (8) 201 (7.894) 6 (0.253) 213 (8.400) 250 (10) 251 (9.866) 8 (0.317) 267 (10.500) 300 (12) 298 (11.740) 10 (0.380) 318 (12.500) 375 (15) 365 (14.378) 12 (0.461) 389 (15.300) 450 (18) 447 (17.573) 14 (0.564) 475 (18.701) 525 (21) 526 (20.713) 17 (0.667) 560 (22.047) 600 (24) 592 (23.303) 19 (0.750) 630 (24.803) 675 (27) 668 (26.263) 21 (0.845) 710 (27.953) Specification Royal Seal gasketed sewer pipe shall be manufactured with a nominal size of 100mm (4 ) to 675mm (27 ) and with Standard Dimension Ratios (SDR) 28 or 35, and shall be certified to CSA B182.2 (PVC Sewer Pipe and Fittings (PSM Type)) and conform to all the requirements of ASTM D3034 (Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings) and F679 (Poly (Vinyl Chloride) (PVC) Large-Diameter Plastic Gravity Sewer Pipe and Fittings). Fabricated fittings shall be manufactured with a nominal size of 100mm (4") to 675mm (27") from SDR 35 pipe and shall be thirdparty certified to CSA B182.2 and conform to the requirements of ASTM F1336 (Poly (VInyl Chloride) (PVC) Gasketed Sewer Fittings). Injection moulded fittings shall be certified to CSA B182.1 (Plastic Drain and Sewer Pipe and Pipe Fittings) and conform to the requirements of ASTM F1336. Long Term T Deflection (%) ASTM Embedment Material Classification Class I - Manufactured Granular Angular Class II - Clean Sand & Gravel Class III - Sand and Gravel with Fines Class IV - Silt and Clay Proctor Density (AASHTO T-99) 0.9 (3.0) 1.5 (5.0) 2.4 (8.0) 3.0 (10.0) 3.7 (12.0) Height of Cover m (ft) 4.3 (14.0) 4.9 (16.0) 5.5 (18.0) 6.1 (20.0) 6.7 (22.0) 7.3 (24.0) 7.9 (26.0) 8.5 (28.0) 90% 0.2 0.3 0.4 0.5 0.6 0.7 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 9.1 (30.0) 90% 0.2 0.3 0.5 0.7 0.8 0.9 1.1 1.2 1.3 1.4 1.6 1.7 1.8 2.0 80% 0.9 1.4 2.3 3.2 3.6 4.1 5.0 5.5 6.0 6.4 7.3 7.7 8.2 9.1 90% 0.2 0.4 0.6 0.8 0.9 1.1 1.2 1.4 1.6 1.7 1.9 2.1 2.2 2.3 85% 0.7 0.9 1.7 2.2 2.6 3.0 3.5 3.9 4.3 4.8 5.2 5.6 6.0 6.5 75% 1.1 1.8 2.9 3.8 4.5 5.5 6.8 8.5 9.9 11.3 12.7 14.1 15.5 16.8 65% 1.3 2.4 3.6 4.7 5.5 6.8 8.5 9.6 11.4 13.0 14.5 16.0 17.3 18.0 85% 0.7 0.9 1.7 2.2 2.6 3.0 3.5 3.9 4.3 4.8 5.2 5.6 6.0 6.5 75% 1.3 2.3 3.3 4.3 5.0 6.5 7.8 9.5 10.6 12.2 13.5 15.0 16.3 17.0 65% 1.3 2.4 3.6 4.7 5.5 8.0 10.5 12.5 15.0 17.6 20.0 22.0 24.0 26.0 Soil conditions are acceptable for this height of cover. Soil conditions are not recommended for this height of cover. Notes: 1. Test data indicates no pipe installed under conditions specified will deflect more than is indicated; the pipe will deflect less than the amount indicated if specified density is obtained. 2. Bedding classifications are in accordance with ASTM D2321. 3. For burial depths not shown, please contact Royal Pipe Systems Technical Services department.

Surrey, BC 12511-82nd Avenue Surrey, BC V3W 3E8 Tel: (604) 591-8274 1-800-663-0696 Fax: (604) 591-2051 Calgary, AB 9225-40th Street SE Calgary, AB T2C 4Z5 Tel: (403) 201-8752 Fax: (403) 201-8753 copyright Royal Pipe Systems 2004. All rights reserved. Winnipeg, MB 1201 Sargent Avenue Winnipeg, MB R3E 3P7 Tel: (204) 783-2924 Fax: (204) 783-2964 Email: info.rpipe@royplas.com Website: www.royalpipe.com Woodbridge, ON 131 Regalcrest Court Woodbridge, ON L4L 8P3 Tel: (905) 856-7550 1-800-263-2353 Fax: (905) 856-4367 Laval, QC 5000 Autoroute 440 West Laval, QC H7T 2Z8 Tel: (450) 688-6069 1-800-465-9754 Fax: (450) 688-6624 Printed 02/2004 - Canada Disclaimer: The information contained herein is believed to be reliable, however Royal Pipe Systems does not warrant the information.