Spectrophotometer Water Quality Analysers Provisional 5 June 2015
Measurements You Trust Photonic Measurements spectrophotometers for water quality measurements provides a rich user interface, that makes complex science simple. The opcal system gives an extended me before service. Preloaded with analycal methods from the leading suppliers, making it easy to upgrade from your current system. Custom methods are simple to program and extra methods can be added or shared via the internet or USB. To give you the spectrophotometer that s best for your applicaon we supply models from visible to UV-Visible, both single to dual beam technologies and solid-state soluons for high precision applicaons.. The analyser has unrivalled data storage with the system allowing results to be stored on board for the lifeme of the device. The Kepler produces PDF reports for archive and management review for calibraons quality control and sample results. The analyser is the smallest in it class, freeing up more bench space with a footprint of a shoebox. The mul-touch HD screen gives the operator a powerful and enjoyable user experience similar to that of modern mobile phone. With no moving opcal components each analyser can take a complete spectra scan in 100ms,.
Instant Mulple Measurements Simultaneous measurements giving mulple results, and our unique algorithms reduce problems of complex water matrices Runs Chemical Methods For Leading Brands The device runs chemical methods from all reagent manufacturers and allows the operator to create their own custom assays as well as import methods onto their system via USB or Wi-Fi Durable Design A device designed to last, with no internal moving parts and optional solid state solution in the visible models Custom Method Builder Allows you to create the tests you want with easy to add scans and mathematical interpretation of the results, so you can focus on the chemistry not the device Data Storage The Capacity to store over 1,000,000 results including every spectra taken, data point recorded and concentration calculated stored, and all at your fingertips with an electronic signature- User Experience An interface that is as easy to use as a mobile phone making complex chemistry simple, and extracting results a joy Device Connectivity Easily transfer data to USB pen drives, plug in off the shelf printers and easy and network access for storage of results. Data exportable to common formats such as excel compatible CSV files and Adobe PDF.
Powerful So7ware Features Measurements Measurements takes just a couple of clicks, select your method and the analyser will visually guide you through the procedure. In real me see the spectra along with the measurement result. Complex signal processing algorithms ensure that every reading is opmised to maximise accuracy, while effects on the peak posion such as from salinity or ph can be countered by using peak hunng algorithms. Quality control and self diagnosis To assure the quality of the analyser, performance of the chemistry and laboratory the analyser performs quality control and self-diagnosis. High, medium and low controls and standard measurements are recorded and analysed via Levy-Jennings plot. Westgard rules are applied to the data to give an in depth understanding of your data. The system runs self diagnosis and calibraon to warn of any system failures. The opcal detec- on system is connuously being analysed, and corrected for variaon Real traceability Every measurement, quality check, spectra and calibraon made is stored on the system, changes to the analyser made in so7ware is logged along with a full electronic signature of the operator, so you can prove the validity of your results. Calibra#on Calibraon is easy, simply enter data points, take measurements and choose the best curve type for your results and you are done! Results are plo9ed onscreen, and can be fi9ed with familiar curves including k-factor, log-logit, spline and polynomial. On compleon the calibraon is stored on the device and a reports can be exported to pdf, printed and the hard copy archived. Data transfer Results can be taken from the device via excel compable CSV files for further analysis using a simple USB or Wi-Fi. Detailed laboratory reports branded with your laboratory logo can be exported to PDF, or sent to your local or network printer. User methods Creaon of user methods is simple with our visual assay builder, and there is almost no limit to the amount of methods you can make and store.
Main Menu Familiar to anyone who has used a modern mobile phone Guided Method The Kepler leads you through every step from sample preparaon to result Measurement Get the detail of your measurement and the outline of the rest of the sample Calibra#on Real me plo=ng of your data, with stascal analysis Quality Control Levey Jennings plot with full Westgard rules implementaon
Kepler Tri-lamp UV-Vis Dual Beam Kepler UV-Vis Dual Beam Opera#ng Mode Source Lamp LEDs (Visible range) Tungsten (Visible -Near IR) Deuterium (UV range) Tungsten (Visible-Near IR) Deuterium (UV range) Wavelength Range 200 1000nm 200 1000nm Wavelength Accuracy TBA TBA Wavelength Reproducibility ± 0nm ± 0nm Wavelength Resolu#on 0.3nm 0.3nm Spectral Bandwidth 1.5nm 1.5nm Scanning Speed 100 msecs 100 msecs Photometric Measuring Range ± 3 Abs ± 3 Abs Photometric Accuracy TBA TBA Photometric Linearity TBA TBA Stray Light <1% <1% Display Data storage Preprogramed Methods Up to 1,000 methods including Hach, Merck, CHEMetrics, Palintest, methods. Up to 1,000 methods including Hach, Merck, CHEMetrics, Palintest, methods. User Programs 20,000 20,000 Sample Cell Compa#bility Rectangle:10,20,50,30,100mm Round: 13mm,16mm,1inch Rectangle:10,20,50,30,100mm Round: 13mm,16mm,1inch Dimensions (H x W x D) 200 x 270 x 390 mm 200x270x390mm Weight <4kg <4kg Storage Condi#ons Enclosure Ra#ng* IP20 with closed lid IP20 with closed lid Interfaces Power Requirement Input Warranty 2 Years 2 Years
Kepler UV-Vis Single Beam Kepler Vis Dual Beam Kepler Vis Single Beam Tungsten (Visible-Near IR) Deuterium (UV range) Solid State Solid State 200 1000nm 350 1000m 350 1000m TBA TBA TBA ± 0nm ± 0nm ± 0nm 0.3nm 0.16nm 0.16nm 1.5nm 0.7nm 0.7nm 100 msecs 100 msecs 100 msecs ± 3 Abs ± 3 Abs ± 3 Abs TBA TBA TBA TBA TBA TBA <1% <1% <1% Up to 1,000 methods Up to 1,000 methods including Hach, Merck, including Hach, Merck, CHEMetrics, Palintest, methods. CHEMetrics, Palintest, methods. Up to 1,000 methods including Hach, Merck, CHEMetrics, Palintest, methods. 20,000 20,000 20,000 Rectangle:10,20,50,30,100mm Rectangle:10,20,50,30,100mm Rectangle:10,20,50,30,100mm Round: 13mm,16mm,1inch Round: 13mm,16mm,1inch Round: 13mm,16mm,1inch 200x270x390mm 200x270x390mm 200x270x390mm <4kg <4kg <4kg IP20 with closed lid IP20 with closed lid IP20 with closed lid 2 Years 2 Years 2 Years * Self Cerfied
Photonic Measurements 5K Weavers Court Belfast BT12 5GH N.Ireland www.photonicmeasurements.com Sales Email: sales@photonicmeasurements.com Tel: +44 (0) 7967650604 Informa#on Email: info@photonicmeasurements.com Tel: +44 (0) 770695477 Photonic Measurements Limited is a company incorporated in N.Ireland (NI622996) and VAT registered in the UK (GB192976846)