Spectrophotometer Water Quality Analysers

Similar documents
Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

73 Series Spectrophotometers

VWR SPECTROPHOTOMETERS

Agilent Cary 60 UV-Vis

Hellma. Where precision becomes an art. Calibration standards for spectrophotometers by Hellma

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Shimadzu UV-VIS User s Guide

instruments Analytical Instruments for Science

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

UV-Vis spectrophotometers

Appendix 5 Overview of requirements in English

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

UV-VISIBLE SPECTROPHOTOMETER

UV/VIS Spectrophotometer PG INSTRUMENTS LIMITED

OLIVÉR BÁNHIDI 1. Introduction

Supporting Information. The G-triplex DNA could function as a new variety of DNA peroxidase

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

GloMax Discover and Explorer. State-of-the-art multimode readers for luminescence, fluorescence and absorbance detection.

EDM SOFTWARE ENGINEERING DATA MANAGEMENT SOFTWARE

Thermo Scientific GENESYS 10S Series UV-Visible Spectrophotometers

SOLSPEC MEASUREMENT OF THE SOLAR ABSOLUTE SPECTRAL IRRADIANCE FROM 165 to 2900 nm ON BOARD THE INTERNATIONAL SPACE STATION

Spectroquant Pharo. No limits. The new spectrophotometer system to meet your individual needs

1/4 Specifications Hidex 300 SL automatic TDCR liquid scintillation counter

Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F)

Ces deux analyseurs permettent le contrôle de la qualité de l eau et des effluents.

MCAL Spectrophotometry. Spectrophotometry

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Experiment #5: Qualitative Absorption Spectroscopy

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

NanoPhotometer. Microvolume and Cuvette Spectroscopy

Mitos P-Pump. product datasheet

Table of contents TABLE OF CONTENTS... 2 ABOUT THIS MANUAL... 3 IMPORTANT NOTES... 3 PICO LOGGING APPLICATION... 5 ABOUT THE PICO LOGGING PC

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July Reprinted from Photonics Spectra, Laurin Publishing

Series. Laser air Leddura Lexinus Mensa. 70 inch. Smart innovation! When function matters.

Measuring Laser Power and Energy Output

Hidex Sense. Hidex Triathler Multi-technology Microplate Reader. Hidex AMG. Consumables. Hidex 300 SL.

SGS: Das Scanning Grating Spektrometer Ein kleines, günstiges Spektrometermodul auf Basis eines dispersiven Mikrosystems

INTERNATIONAL OLIVE COUNCIL

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Reaction of Blue Food Dye with Bleach

An Econocom Group company. Your partner in the transi4on towards Mobile IT

Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors

Preparing BD Systems for Data Migration. Summary of the Upgrade Process on page 6. Copying User Data Files onto an Upgraded System on page 7

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Thermo Scientific NanoDrop Products. Revolutionary technology. Elegant simplicity. Instruments for microvolume analysis of biomolecules

V6 AIRS Spectral Calibra2on

Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Enjoy easy, fast and versatile scanning

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

VeriSign PKI Client Government Edition v 1.5. VeriSign PKI Client Government. VeriSign PKI Client VeriSign, Inc. Government.

Navi-Radar 4000 and Navi-Sailor 4000 ECS for workboats and small crafts BIG SOLUTIONS FOR SMALL VESSELS

Quantifying Bacterial Concentration using a Calibrated Growth Curve

BUDGETARY QUOTATION AND TECHNICAL INFORMATION

SpecLine Offline Spectroscopy Analysis Software SPECLINE-P/SPECLINE-U. Installation and Operation Manual Document Number

Let Tecan care about your routine data calculation

Quick Start Guide Chromeleon 7.2

Introduction to Fourier Transform Infrared Spectrometry

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

Analyze IQ Spectra Manager Version 1.2

Test equipment for temperature and its reduction

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

How do I Check if My Computer is Compatible with Windows 7

Embest DSO2300 USB Oscilloscope

Turning HTE Agilent LC/MS Data to Knowledge in 1hr

Operating manual. innovaphone Fax. Version 10. Documents that are to be faxed are basically sent as an attachment.

Xerox Security Bulletin XRX13-006

Uses of Derivative Spectroscopy

UVBrewer. Martin Stanek Solar and Ozone Observatory of CHMI , Hradec Kralove, Czech Republic,

PROPALMS TSE 6.0 March 2008

X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

UV-VIS-NIR. Varian Cary 4000, 5000 and 6000i Spectrophotometers

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Wireless Data Logger Monitoring Systems

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

Microsoft Dynamics NAV

IKEA Light Sources Technical Information Update

UNICORN 7.0. Administration and Technical Manual

PRINT FLEET MANAGER USER MANUAL

Spectrum Scarcity and Free Space Op1cal Communica1ons. Mohamed- Slim Alouini KAUST January 2014

FREQUENTLY ASKED QUESTIONS (FAQs) 123Scan 2 Scanner Configuration Utility

Transcription:

Spectrophotometer Water Quality Analysers Provisional 5 June 2015

Measurements You Trust Photonic Measurements spectrophotometers for water quality measurements provides a rich user interface, that makes complex science simple. The opcal system gives an extended me before service. Preloaded with analycal methods from the leading suppliers, making it easy to upgrade from your current system. Custom methods are simple to program and extra methods can be added or shared via the internet or USB. To give you the spectrophotometer that s best for your applicaon we supply models from visible to UV-Visible, both single to dual beam technologies and solid-state soluons for high precision applicaons.. The analyser has unrivalled data storage with the system allowing results to be stored on board for the lifeme of the device. The Kepler produces PDF reports for archive and management review for calibraons quality control and sample results. The analyser is the smallest in it class, freeing up more bench space with a footprint of a shoebox. The mul-touch HD screen gives the operator a powerful and enjoyable user experience similar to that of modern mobile phone. With no moving opcal components each analyser can take a complete spectra scan in 100ms,.

Instant Mulple Measurements Simultaneous measurements giving mulple results, and our unique algorithms reduce problems of complex water matrices Runs Chemical Methods For Leading Brands The device runs chemical methods from all reagent manufacturers and allows the operator to create their own custom assays as well as import methods onto their system via USB or Wi-Fi Durable Design A device designed to last, with no internal moving parts and optional solid state solution in the visible models Custom Method Builder Allows you to create the tests you want with easy to add scans and mathematical interpretation of the results, so you can focus on the chemistry not the device Data Storage The Capacity to store over 1,000,000 results including every spectra taken, data point recorded and concentration calculated stored, and all at your fingertips with an electronic signature- User Experience An interface that is as easy to use as a mobile phone making complex chemistry simple, and extracting results a joy Device Connectivity Easily transfer data to USB pen drives, plug in off the shelf printers and easy and network access for storage of results. Data exportable to common formats such as excel compatible CSV files and Adobe PDF.

Powerful So7ware Features Measurements Measurements takes just a couple of clicks, select your method and the analyser will visually guide you through the procedure. In real me see the spectra along with the measurement result. Complex signal processing algorithms ensure that every reading is opmised to maximise accuracy, while effects on the peak posion such as from salinity or ph can be countered by using peak hunng algorithms. Quality control and self diagnosis To assure the quality of the analyser, performance of the chemistry and laboratory the analyser performs quality control and self-diagnosis. High, medium and low controls and standard measurements are recorded and analysed via Levy-Jennings plot. Westgard rules are applied to the data to give an in depth understanding of your data. The system runs self diagnosis and calibraon to warn of any system failures. The opcal detec- on system is connuously being analysed, and corrected for variaon Real traceability Every measurement, quality check, spectra and calibraon made is stored on the system, changes to the analyser made in so7ware is logged along with a full electronic signature of the operator, so you can prove the validity of your results. Calibra#on Calibraon is easy, simply enter data points, take measurements and choose the best curve type for your results and you are done! Results are plo9ed onscreen, and can be fi9ed with familiar curves including k-factor, log-logit, spline and polynomial. On compleon the calibraon is stored on the device and a reports can be exported to pdf, printed and the hard copy archived. Data transfer Results can be taken from the device via excel compable CSV files for further analysis using a simple USB or Wi-Fi. Detailed laboratory reports branded with your laboratory logo can be exported to PDF, or sent to your local or network printer. User methods Creaon of user methods is simple with our visual assay builder, and there is almost no limit to the amount of methods you can make and store.

Main Menu Familiar to anyone who has used a modern mobile phone Guided Method The Kepler leads you through every step from sample preparaon to result Measurement Get the detail of your measurement and the outline of the rest of the sample Calibra#on Real me plo=ng of your data, with stascal analysis Quality Control Levey Jennings plot with full Westgard rules implementaon

Kepler Tri-lamp UV-Vis Dual Beam Kepler UV-Vis Dual Beam Opera#ng Mode Source Lamp LEDs (Visible range) Tungsten (Visible -Near IR) Deuterium (UV range) Tungsten (Visible-Near IR) Deuterium (UV range) Wavelength Range 200 1000nm 200 1000nm Wavelength Accuracy TBA TBA Wavelength Reproducibility ± 0nm ± 0nm Wavelength Resolu#on 0.3nm 0.3nm Spectral Bandwidth 1.5nm 1.5nm Scanning Speed 100 msecs 100 msecs Photometric Measuring Range ± 3 Abs ± 3 Abs Photometric Accuracy TBA TBA Photometric Linearity TBA TBA Stray Light <1% <1% Display Data storage Preprogramed Methods Up to 1,000 methods including Hach, Merck, CHEMetrics, Palintest, methods. Up to 1,000 methods including Hach, Merck, CHEMetrics, Palintest, methods. User Programs 20,000 20,000 Sample Cell Compa#bility Rectangle:10,20,50,30,100mm Round: 13mm,16mm,1inch Rectangle:10,20,50,30,100mm Round: 13mm,16mm,1inch Dimensions (H x W x D) 200 x 270 x 390 mm 200x270x390mm Weight <4kg <4kg Storage Condi#ons Enclosure Ra#ng* IP20 with closed lid IP20 with closed lid Interfaces Power Requirement Input Warranty 2 Years 2 Years

Kepler UV-Vis Single Beam Kepler Vis Dual Beam Kepler Vis Single Beam Tungsten (Visible-Near IR) Deuterium (UV range) Solid State Solid State 200 1000nm 350 1000m 350 1000m TBA TBA TBA ± 0nm ± 0nm ± 0nm 0.3nm 0.16nm 0.16nm 1.5nm 0.7nm 0.7nm 100 msecs 100 msecs 100 msecs ± 3 Abs ± 3 Abs ± 3 Abs TBA TBA TBA TBA TBA TBA <1% <1% <1% Up to 1,000 methods Up to 1,000 methods including Hach, Merck, including Hach, Merck, CHEMetrics, Palintest, methods. CHEMetrics, Palintest, methods. Up to 1,000 methods including Hach, Merck, CHEMetrics, Palintest, methods. 20,000 20,000 20,000 Rectangle:10,20,50,30,100mm Rectangle:10,20,50,30,100mm Rectangle:10,20,50,30,100mm Round: 13mm,16mm,1inch Round: 13mm,16mm,1inch Round: 13mm,16mm,1inch 200x270x390mm 200x270x390mm 200x270x390mm <4kg <4kg <4kg IP20 with closed lid IP20 with closed lid IP20 with closed lid 2 Years 2 Years 2 Years * Self Cerfied

Photonic Measurements 5K Weavers Court Belfast BT12 5GH N.Ireland www.photonicmeasurements.com Sales Email: sales@photonicmeasurements.com Tel: +44 (0) 7967650604 Informa#on Email: info@photonicmeasurements.com Tel: +44 (0) 770695477 Photonic Measurements Limited is a company incorporated in N.Ireland (NI622996) and VAT registered in the UK (GB192976846)