INFORMATION DOCUMENT



Similar documents
32/1/ /PVSE(Part-II) Ministry of New and Renewable Energy SPV Off Grid Division

Financial Analysis of Solar Photovoltaic Power plant in India

Ministry of New and Renewable Energy. Jawaharlal Nehru National Solar Mission SOLAR PHOTOVOLTAIC WATER PUMPING SYSTEMS ( )

POWER PURCHASE AGREEMENT FOR ROOFTOP SOLAR PV PLANTS WITH NET METERING ARRANGEMENT

TECHNICAL SPECIFICATIONS

Guidelines for Grid-connected Small Scale (Rooftop) Solar PV Systems for Tamil Nadu Version: April 2014

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Residential Solar Service Agreement (RSSA) Customer Sited Solar Photovoltaic Systems

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

MAHARASHTRA ELECTRICITY REGULATORY COMMISSION, MUMBAI

Introduction for Photovoltaic Power System Test in China. Zou Xinjing Institute of Electrical Engineering Chinese Academy of Sciences Nov.

Format - 17 GUIDELINES FOR ON-GRID SOLAR RTPV PROGRAMME (ON NET- METERING BASIS) FOR BESCOM OFFICERS

ABB central inverters PVS to 1000 kw

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

NASS Solar DC Pool Pumps

Unitil Energy Systems, Inc. Interconnection Standards For Inverters Sized Up To 100 kva

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Re-defining the utility-scale inverter

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Using the sun to generate electricity

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

Photovoltaic Solar Energy Unit EESFB

BB800 Off-Grid Solar System

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Section III Schedule of Requirements TECHNICAL SPECIFICATIONS OF THE REQUIRED SYSTEMS

Additional Solar System Information and Resources

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

NET METERING SUB-CODE. for Connecting Renewable Energy Generating Systems to the Distribution Network in Ghana

Thyristor-controlled power supplies and battery chargers

How To Use A Power Supply Unit (Upu)

Power Electronics Testings

SA Power Networks Planning for Solar PV? Customer information guide to network connected solar PV inverter systems

Stand Alone PV System Sizing Worksheet (example)

Manual. EN Appendix. Blue Solar PWM Pro setup and monitoring software

Solar Home System Kit Quality Standards

YSmart Technology Co.,Ltd

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

INVERTER SYSTEM PRODUCT BROCHURE

FIT TIER 2 Application

User s Manual Before using the inverter, you need to read and save the safety instructions.

CUTES Solar Power System

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Energy Communication Unit (ECU)

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

HYBRID POWER SYSTEMS for TELECOM applications

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

A. 5MWp SPV Plant at Khimsar, Rajasthan. B. 5MWp SPV Plant Installed Technologies. D. 5MWp SPV Plant Challenges. E. 5MWp SPV Plant - Performance

EXPRESSION OF INTEREST (EOI) 001/ DT

ADDENDUM #1(BID PACKAGE # 3)

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

KERALA STATE ELECTRICITY REGULATORY COMMISSION

File No. 5/22/ /RT Ministry of New and Renewable Energy Grid Connected Rooftop Solar Power Division *****

Romana Brentgens / photon-pictures.com (2)

Fronius IG Plus. The next generation grid-connected PV inverter

Corona Department of Water & Power (DWP) Solar Partnership Program Guidelines and Application

SOLAR ChARge CONTROLLeRS

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Model Renewable Energy Wheeling Agreement under Renewable Energy Certificate (REC) scheme

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

NBF. Electrical. WHY GO SOLAR? NBF ELECTRICAL EXPLAINS WHY

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

Your Sharp system will be supplied with one of the following sets of panels:

KERALA STATE ELECTRICITY REGULATORY COMMISSION

SECTION VARIABLE FREQUENCY DRIVES

Solar Rooftop Policy/ Guidelines

Application Information Improving Efficiency in Smart Grid Applications With Fully Integrated Current Sensing ICs

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

When Do Solar Electric & Utility Back-Up Systems Make Sense?

Generation Interconnection System Impact Study Report. For. PJM Generation Interconnection Request Queue Position X1-114.

PREMIUM CLASS PHOTOVOLTAICS

APPLICATION NOTE USING A MODEL 3060-MS SERIES AS A REGENERATIVE AC SOURCE FOR PV INVERTER TEST APPLICATIONS. Abstract.

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL

Satcon Solstice 100 kw System Solution

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

SOLAR PV INFORMATION. January, 2015

How To Make A Fronius Cl Power Inverter

Photovoltaic Incentive Program

13 Watt PORTABLE SOLAR POWER KIT

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

UPS Applications and VRLA Battery Sizing

12 Volt 30 Amp Digital Solar Charge Controller

SRS2025. Home & small Business. Energy Storage Solution

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Photovoltaic System Overcurrent Protection

Marketing Methodology of Solar PV Power Packs

Uninterruptible Power Supply

Solar Solutions and Large PV Power Plants. Oscar Araujo Business Development Director - Americas

Request for Quotation: Design, supply, delivery and installation of web based photovoltaic monitoring system for solar traffic lights.

Distribution Operations with High-penetration of Beyond the Meter Intermittent Renewables. Bob Yinger Southern California Edison April 15, 2014

Inverter / Charger Installation General Operations and AC and DC Connections

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

Technical Data. back-up time in minutes 100% load % load

SolarMax P series The power package for residential solar plants

Transcription:

INFORMATION DOCUMENT For Design, manufacture, supply, installation and commissioning of different capacity Roof top Solar PV Power projects under Net Metering policy in the state of Punjab. PUNJAB ENERGY DEVELOPMENT AGENCY SOLAR PASSIVE COMPLEX Plot no. 1&2 Sector 33-D CHANDIGARH 160 034, INDIA TELEPHONES: (91) 0172-2663328,26633802, 2600863 FAX : (91) 0172 2662865 WEBSITE : HTTP://PEDA.GOV.IN 1

CONTENTS S. No. Subject Page No. 1 Expression of Interest 3 2 Net Metering 4 3 Eligibility Criteria and other terms & conditions 5 & 6 4 Annexure I : (General Technical Specifications & Line Diagrams of Net Metering System) 7-13 5 Proforma I :- Format for forwarding letter 14 6 Proforma II :- Manufacturers' Authorization for supplier 15 7 Proforma III :- Turnover Record and profit certificate Form 16 8 Proforma IV :- Performa for submission of rates of different capacity roof top Solar PV Power Projects. 9 Proforma V :- Performa for submission of rates of different components of roof top Solar PV Power Projects 17 18 2

Punjab Energy Development Agency Plot No. 1 & 2, Sector 33-D, Chandigarh Ph.: 0172-2663328, 2600863 Fax : 0172-2662865 www.peda.gov.in, peda_spa@yahoo.co.in PEDA/NMP/EOI/2014-15/01 Promoting Clean Energy Through Solar Roof Tops Golden opportunity for EPC companies, manufacturers, suppliers &system integrators of Solar PV Power Projects for design, manufacture, supply, installation and commissioning of different capacity Roof Top Solar Power Projects. Punjab Government has approved Net Metering Policy under which Roof Top Solar PV Power Projects of capacities ranging from 1KW to 1000KW are to be installed on different categories of buildings i.e Homes, Institutions, Commercial/ Private / Govt. Buildings/ warehouses & Industries. In order to facilitate the public, Punjab Energy Development Agency, the state Nodal Agency is in the process of compiling information of rates of different capacity Roof Top solar power projects which are to be displayed on the website of PEDA for the information of the Public. EPC Companies desirous of getting their information displayed may submit the technical detail of their systems/ equipments and pricing in the Performa available at www.peda.gov.in. before 25th November 2014. Other details and technical specifications may please be seen in the information document available on PEDA website Chief Executive 3

Net Metering Net metering is a process through which a solar power project is installed on the roof top of the building. During day time sun rays fall on solar panels and generate electricity. The generated power is used in the building for running electrical appliances and the surplus power is fed in to the grid of PSPCL and power from the grid of PSPCL utility is consumed in the building at night or when the solar power generation is less than the requirements during day time. A bi-directional meter is installed in the supply line to register import and export of power. The reading of import and export of power is taken and sets off for net consumption of units. The bill is prepared for net consumption of units at the rates applicable under that specified electricity tariff slab. Net metering arrangements, thus, combine elements of captive consumption and exchange of power with the utility. During power cut from PSPCL, the Rooftop Solar PV System will continue to supply the power. Energy Flow Diagram under net Metering 4

1. Eligibility Criteria and other terms & conditions : 1.1 This invitation open to all EPC companies, manufacturers, suppliers &system integrators of Solar PV Power Projects who have not been debarred/black listed by any Govt. organization for design, manufacture, supply, installation and commissioning of different capacity Roof Top Solar Power Projects. 1.2 The company or authorized supplier shall have minimum 2 years experience in installation of Solar power projects as on 31.03.2014. 1.3 The minimum annual turnover of the company should be Rs.50 Lac during any one financial year out of the last three financial years i.e.2011-12,2012-13&-14. 1.4 The company / supplier should be in profit for at least two financial years out of the last three financial years i.e. 2011-12, 2012-13&-14. 1.5 The offers shall be accompanied with a set of complete technical literature, operation and maintenance manual of the product in English Language. 1.6 Material shall be strictly as per laid down specifications and If there is any left out specification, in the Information Document the same shall be considered as per the latest MNRE specifications and guidelines. 1.7 The SPV modules shall be warranted for 25 years and complete SPV systems including batteries would be warranted by the manufacturer for five years, from the date of commissioning of the Project. After Installation & Commissioning Solar roof top power project shall be jointly visited by a committee of supplier, user and District Officer of PEDA. 1.8 The companies should have their secure network in Punjab and shall provide address of service centers in a separate sheet All disputes relating to this work shall be subject to the jurisdiction of the place of installation of the project. 2 Scope of Supply: The SPV power plants should be supplied & installed by the companies as per specifications given in Annexure I which comply to the MNRE,GOI Guidelines. Following parts for each SPV projects are mainly required to be supplied: 1. SPV Module of capacity ranging from 100Wp and above 2. Batteries of appropriate capacity 3. Power conditioning Unit (PCU) 1KW and above 4. PVC insulated Copper cables as per BIS Codes for AC & DC inter connections. 5. Junction Boxes with surge arrestors and MCB. 6. Structure for solar PV project, MS Galvanized / Aluminum. 7. O&M manual and warranty card in English Language Any other part as per site requirement. 5

3. WARRANTY i. The Solar power projects including the battery shall be warranted for five years after the date of commissioning of the project for replacement in case of any manufacturing, operation failure, non performance as per design standards. ii. The PV module(s) shall be warranted for a minimum period of 25 years from the date of commissioning of the project. The PV modules must be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten (10) years and 80% at the end of Twenty five (25) years. iii. The Warranty Card to be supplied with the system must contain the details of the system. 4. Maintenance during Warrantee period of five years: a. Schedule visit of the supplier s engineer to the site on quarterly basis for maintenance/ assessing the maintenance requirements. b. Visit to the site on call basis to provide maintenance services within three days of lodging of complaint. c. Corrective & remedial maintenance services to set right the malfunction of the SPV-projects include supply and replacement of all damaged parts/ components including electronics/ charge controller, Inter connected cables/ parts and fuse etc. with new parts. 5. OPERATION & MAINTENANCE MANUAL An Operation, Instruction and Maintenance Manual, in English & Punjab Languages should be provided with the Solar PV projects. The following minimum details must be provided in the Manual: Basic principles of Photovoltaic. A small write-up (with a block diagram) on the Solar PV project - its components, PV module, battery, electronics and luminary and expected performance shall be provided. Type, Model number, Voltage & capacity of the battery, used in the system. The make, model number, country of origin and technical characteristics of all the component are required to be provided. Clear instructions on regular maintenance and trouble shooting of the Solar PV Projects. DO's and DONT's. Name and address of the contact person for repair and maintenance, in case of non-functionality of the SPV Projects. 6

ANNEXURE-I General Technical specifications 1. SPV Modules : (i) Indigenously manufactured PV modules should be used. (ii) The PV module should have crystalline silicon solar cells and must have a certificate of testing conforming to IEC 61215 Edition II / BIS 14286 from an NABL or IECQ accredited Laboratory. (iii) The power output of the module(s) under STC should be a minimum of 100 Wp at a load voltage* of 16.4 ± 0.2 V. V nom 12V. (iv) The open circuit voltage* of the PV modules under STC should be at least 21.0 Volts. (v) The module efficiency should not be less than 14 %. (vi) The terminal box on the module should have provision for opening to replace the cable, if required. (vii) PV modules must be warranted for their output peak watt capacity which should not be less than 90 % at the end of 10 years and 80% at the end of 25 years. (viii) Identification and Traceability Each PV module used in any solar power project must use a RF identification tag. The following information must be mentioned in the RFID used on each module (This should be inside the laminate and must be able to withstand harsh environmental conditions.) a) Name of the Manufacturer of PV module b) Name of the manufacturer of Solar Cells. c) Month and year of the manufacture (separately for solar cells and module). d) Country of origin (separately for solar cells and module). e) I-V curve for the module. f) Peak wattage, Im,Vm and FF for the module. g) Unique serial no and model no of the module. h) Date and year of obtaining IEC PV module qualification certificate. i) Name of test lab issuing IEC certificate j) Other relevant information on traceability of solar cells and module as per ISO 9000 series. 2. BATTERY i. Tubular Lead Acid battery having minimum rating of 2 V 200Ah &12V, 150 Ah & higher capacities at C/10 discharge rate. ii. 75% of the rated capacity of the battery should be between fully charged and load cut off conditions. iii. Battery should conform to the latest BIS/ International standards. 3. Balance of system (BOS) a. Cables should confirm to applicable standards i,e IEC 60189, IS 694/ IS1554, IS/IEC 69947. 7

b. Switches / Circuit Breakers / Connector should confirm to IS/IEC 60947 part I,II,III, EN 50521 standards. c. Junction Boxes should confirm to IP 65 for outdoor / IP 21 for indoor use and IEC 62208 standards. d. SPV system design should confirm to IEC 62124 standards e. Installation of systems should confirm to IEC 60364-7-712 standards 4. Power Conditioning Unit (PCU) The PCU should convert DC power produced by SPV modules, in to AC power and adjust the voltage & frequency levels to suit the local grid conditions. The inverter shall interconnect and feed power to the LT power supply of the building and also shall have the provision to power critical loads. Common Technical Specification : Control Type : Voltage source, microprocessor assisted, output regulation Out put voltage : Single Phase, 230 V ac ( +12.5 %, - 20 % V ac) : 3, 415 V ac ( +12.5 %, - 20 % V ac) Frequency : 50 Hz ( +3 Hz, -3 Hz) Total Harmonic Distortion : less than 3% Operating temperature Range : 0 to 55 deg C Inverter standards : Inverter should comply with IEC 61683/IS 61683 for efficiency and Measurements and should comply IEC 60068-2 (1, 2, 14, 30) / Equivalent BIS Standard for environmental testing. Inverter should supervise the grid condition continuously and in the event of grid failure (or) under voltage (or) over voltage, Solar System should be disconnected by the circuit Breaker / Auto switch provided in the inverter. Power Control : MPPT Other important Features/Protections required in the INVERTER Automatic morning wake-up and nightly shutdown Mains (Grid) over-under voltage and frequency protection Fool proof protection against ISLANDING. Included authentic tracking of the solar array s maximum power operation voltage (MPPT). Array ground fault detection. 8

LCD and piezoelectric keypad operator interface Menu driven Automatic fault conditions reset for all parameters like voltage, frequency and/or black out. Surge arresters on AC and DC terminals for over voltage protection from lightning-induced surges. INVERTER should be rated to operate at 0 55 deg. Centigrade unless provision for air conditioning is included in INVERTER All parameters should be accessible through an industry standard communication link. Overload capacity (for 10 sec) should be 150 % of continuous rating Harmonics Standard : As per the standard of IEEE 519, the permissible individual harmonics level shall be less than 3% (for both voltage and current harmonics) and Total Harmonics Distortion (THD) for both voltage and current harmonics of the system shall be less than 5%. Technical and interconnection requirements Overall conditions of service State Distribution/Supply Code State Distribution/Supply Code Overall Grid Central Electricity Central Electricity Standards Authority (Grid Standard) Authority (Grid Standard) Regulations 2010 Regulations 2010 Equipment BIS / IEC / IEEE BIS / IEC / IEEE Meters Central Electricity Central Electricity authority (Installation & authority (Installation & operation of meters) operation of meters) Regulation 2006 as Regulation 2006 as amended time to time amended time to time Safety and supply Harmonic Requiremen ts Harmonic Current Central Electricity Authority(measures of safety and electricity supply) Regulations, 2010 IEEE 519 CEA (Technical Standards for 9 Central Electricity Authority(measures of safety and electricity supply) Regulations, 2010 IEEE 519 CEA (Technical Standards for

Synchronization Voltage IEEE 519 CEA (Technical Standards for IEEE 519 CEA (Technical Standards for Flicker IEEE 519 CEA (Technical Standards for Photovoltaic system must be equipped with a grid frequency synchronization device. Every time the generating station is synchronized to the electricity system. It shall not cause voltage fluctuation greater than +/- 5% at point of connection. The voltage-operating window should minimize nuisance tripping and should be under operating range of 80% to 110% of the nominal connected voltage. Beyond a clearing time of 2 second, the photovoltaic system must isolate itself from the grid. Operation of Photovoltaic system should not cause Frequency DC injection IEEE 519 CEA (Technical Standards for IEEE 519 CEA (Technical Standards for When the Distribution system frequency deviates outside the specified conditions (50.5 Hz on upper side and 47.5 Hz on lower side), There should be over and under frequency trip functions with a clearing time of 0.2 seconds. Photovoltaic system should not inject DC power more than 0.5% of full rated output at the interconnection point or 1% of rated inverter output current into distribution system under any operating conditions. 10

Power Factor Islanding and Disconnection Overload and Overheat Paralleling Device IEEE 519 CEA (Technical Standards for IEEE 519 CEA (Technical Standards for IEEE 519 CEA (Technical Standards for IEEE 519 CEA (Technical Standards for While the output of the inverter is greater than 50%, a lagging power factor of greater than 0.9 should operate. The photovoltaic system in the event of fault, voltage or frequency variations must island/disconnect itself within IEC standard on stipulated period. The inverter should have the facility to automatically switch off in case of overload or overheating and should restart when normal conditions are restored. Paralleling device of photovoltaic system shall be capable of withstanding 220% of the normal voltage at the interconnection point. Meter Configuration options The metering system for rooftop solar system, under net-metering arrangement, shall be as elaborated below which should be applicable till such time the Central Electricity Authority notifies the standards in this matter. a) Two Meter Configuration without Storage The metering protocol for Grid connected rooftop solar PV system without storage and location of solar meter and consumer meter shall be in accordance with the schematic below:- 11

12

C:\Users\admin\Desktop\net mtrg\dnit NMP.doc The utility meter (Net-meter) has to be bi-directional meter to register both import grid electricity amount as well as export solar electricity amount. Two Meter Configuration with Storage The metering protocol for Grid connected rooftop solar PV system with storage and location of Solar Meter (SM) and Utility Meter (UM) shall be in accordance with the schematic below:- The utility meter (Net-meter) has to be bi-directional meter to register both import grid electricity amount as well as export solar electricity amount. 13

C:\Users\admin\Desktop\net mtrg\dnit NMP.doc PROFORMA-I Format for forwarding letter (To be submitted by Companies on the official letter head of the company) No. Dated:- To The Director Punjab Energy Development Agency Plot No 1 &2, Sector 33D, Chandigarh Subject:- Design, manufacture, supply, installation and commissioning of different capacity Roof top Solar PV projects under Net Metering policy in the state of Punjab. Sir, We here by submit our offer in compliance with terms and conditions of the Net metering document PEDA/NMP/EOI/2014-15/01. As specified, the offer has been submitted a) That we are submitting this offer under the above mentioned notice after having fully read and understood the nature of the work and having carefully noted all the specifications, terms and conditions laid down in the Net metering document. b) That we have never been debarred from executing similar type of work by any central/state/public sector undertaking/department. c) That we shall execute the work as per specifications, terms and conditions of the net metering document. d) That our offer shall remain valid for placement of purchase order/ orders for one year after finalization rates. e) We are not involved in any major litigation that may have an impact on the delivery installation & commissioning of the project under this document f) I have read and accepted all the terms and conditions of this document. Yours faithfully, Proprietor (..) Name, Seal &Signature (Authorized Signatory) 14

C:\Users\admin\Desktop\net mtrg\dnit NMP.doc PROFORMA-II (To be submitted on Stamp Paper of Rs.100/- ) MANUFACTURERS' AUTHORIZATION FOR SUPPLIER To No. dated Net metering document. PEDA/ NMP/EOI/2014-15/01 Dear Sir: We who are established and reputable manufacturers of (name & descriptions of goods offered) having factories at (address of factory) do hereby authorize M/s (Name and address of authorized supplier ) to submit the offer for the goods manufactured by us against the above document. We hereby extend our full guarantee and warrantee of 5 years for the goods and services offered for supply by the M/s against this Project in the state of Punjab. Yours faithfully, (Name) (Name of manufacturer) Note: This letter of authority should be on the Stamp paper and should be signed by a person competent and having the power of attorney to legally bind the manufacturer. 15

C:\Users\admin\Desktop\net mtrg\dnit NMP.doc PROFORMA-III TURNOVER RECORD FORM To be certified by Chartered Accountant Name of Company:- Annual turnover data for past three years Sr. No. Year Turnover (Rs. In Lacs) Profit Loss 1 2 3 4 5 1. 2011-12 2. 2012-13 3. -14 Signature with seal of the company Signature with seal of the Chartered Accountant 16

C:\Users\admin\Desktop\net mtrg\dnit NMP.doc PROFORMA-IV Performa for submission of rates of different capacity roof top Solar PV Power Projects under Net Metering Policy of Punjab. Name of company :- Description Make Capacity 1 2 3 5 10 15 20 30 50 80 100 200 300 400 500 Rooftop solar PV power project (in KWp) price (In Rs.) Signature & Stamp of Rep. of company 17

C:\Users\admin\Desktop\net mtrg\dnit NMP.doc PROFORMA- V Performa for submission of rates of different components of roof top Solar PV Power Projects under Net Metering Policy of Punjab. Sr. No Name of company :- Description of Devices Make Capacity & Rate 1. Solar Panels Capacity (Wp) 100 150 200 250 300 Rate (Rs.) 2. PCU Capacity (KVA) 1 2 3 5 10 15 20 30 50 80 100 Single Single Single Single Three Three Three Three Three Three Three Rate (Rs.) 3. Battery (Tubular Lead Acid) Capacity (Ah) Rate (Rs.) 12V 150 Ah 12V 180 Ah 12V 200 Ah 12V 250 Ah 2V 200 Ah 2V 500 Ah 2V 800 Ah 2V 1000 Ah 2V 1500 Ah 2V 2000 Ah 2V 2500 Ah 18 Signature & Stamp of Rep. of company