STAATSKOERANT, 19 DESEMBER 2003 No. 25853 473 ASSESSMENT CWITERlON I 1, Conditions are assessed and safety measures implemented according to safe work procedures. ASSESSMENT CRjTERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENT CRITERION 2 2. Ensure that the affected section of the Medium / High Voltage network is isolated and permits obtained where necessary when working close proximity to live apparatus according to high voltage regulations. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENT CRITERION 3 3. The underground earth connections are exposed and cleaned as per job procedures. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENTCRITERION 4 4. Earth connections are bridged by means a of flexible earth lead prior to disconnecting as per safe work procedures. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENT CRITERION 5 5. The applicable test instruments are selected and testing carried out according to specific task requirements. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENTCRITERION 6 6. Safety precautions / procedures are followed before, during and after testing of earthing installation. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE ASSESSMENT CRITERION 7 7. Safety precautions / procedures are followed before, during and after inspection of earthing installation. ASSESSMENT CRITERION NOTES ASSESSMENT CRITERION RANGE 03/10/29 US ID: 1 13882 SAM: NLRD Report Unit Standard Detail Page 4
STAATSKOERANT, 19 DESEMBER 2003 No. 25853 477 SOUTH AFRICAN QUALIFICATIONS AUTHORITY SAQA US ID 113883 FIELD DESCRlPTlON UNIT STANDARD: 35 Install / replace high voltage equipment and hardware UNIT STANDARD TITLE Install / replace high voltage equipment and hardware SG8 NAME * SGB Electrical Engineering & Construction ABET BAND Undefined PROVIDER NAME SUBFIELD DESCRiPTlON Electrical Infrastructure Construction ' - Physical Planning and Construction UNIT STANDARD CODE IUNtT STANDARD TYPE INQF LEVEL ICREDITS L I I PPC-EIC-0-SGB ECC llevel4 IRegular (6 REGISTRATION I REGISTRATION END I REGISTRATION I SAQA DECISION NUMBER START DATE I DA TE I NUMBER I PURPOSE OF THE UNIT STANDARD This unit standard is for persons in the electrical distribution station environment. The person credited with this unit standard is capable of planning, installing & replacing, High Voltage equipment (current I voltage transformers, isolators, breakers, surge arrestors) according to statutory requirements to distribute and control electricity to electrical installations. This unit standard will contribute to the full development of the learner within the electrical engineering and construction environment by providing recognition, further mobility and transportability within the field of Physical Planning and Construction. The skills, knowledge and understanding demonstrated within this Unit standard are essential for social and economic transformation and upliftment within the electrical engineering and construction environment. LEARNING ASSUMED ro BE IN PLACE > Apply & maintain safety in an electrical environment (L2 Unit Standard). > Basic hand tools. > Portable power tools. > Introduction to industry. z Plan, install & terminate electrical cables & conductors. > Basic rigging skills. > Operating of Mobile crane. z Read and relate to drawings, circuits & diagrams. > Operating regulations for High Voltage systems - responsible person. UNIT STANDARD RANGE High Voltage equipment include, but are not limited to: > Structure mounted types > Above 33kV, up to and including 132kV High Voltage cables / conductor terminations include, but are not limited to: > Disconnecting & re-connecting cable glands / terminations > Disconnecting 8, reconnecting of droppers I jumpers > Disconnecting & re-connecting earth straps 03/10/29 US ID: 113883 SAW: NLRD "Unit Report Standard Detail" Page 1
.........
SSESS