User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams



Similar documents
Series 1400 Pulsatile Blood Pumps User's Manual

Model SRMD Setra Remote Monitoring Display

Advantium 2 Plus Alarm

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

INSTRUCTION MANUAL MODEL PCD-88

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

3M Wrist Strap and Footwear Tester 740. User s Guide

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

AXIS T81B22 DC 30W Midspan

HVA200 High Voltage Amplifier

Amplified High Speed Fiber Photodetectors

Instructions A Amp AC/DC Current Probe

BroadBand PowerShield. User Manual

aseries A13B Mini Bullet Camera User Manual

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

APG-XT APG-HPD. Operating Manual. Internal APG (Analog Programming) Interface for XT/HPD Series Programmable DC Power Supply

INSTRUCTION MANUAL T1 TO RS422 INTERFACE

i410/i1010 AC/DC Current Clamp

Coax Mapping Tester User's Guide.

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Seven function digital multimeter

Experiment 5. Strain Gage Measurements

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Nest Learning Thermostat Installation Guide. Installation step-by-step

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

External Hard Drive esata & USB 2.0 Combo. User Guide English

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

±15 V Current-Limited Power Supply

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Periodic Verification System Model 775PVS


DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

700/732 SERIES. 5mm HOUR METERS & COUNTERS. CURTIS INSTRUMENTS, INC. 200 Kisco Avenue, Mt. Kisco, NY Tel. (914) FAX (914)

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Series 1400 Pulsatile Blood Pumps User's Manual

Owner s Manual & Safety Instructions

Table of Contents. HDMI to 3G/HD/SD SDI Converter Box DVC 3GTx Manual. Introduction 3. System 5. Instruction 6. Dimensions 8. Mounting (Optional) 8

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

Installation and Operation Guide for PD4100 Series Power Control Centers

Owner s Manual & Safety Instructions

Hot Water Urns. all models. Helpline. v3.0

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

HIH-4000 Series Humidity Sensors

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

3 WATT LED SPOTLIGHT Model No. SLM

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Global Water Instrumentation, Inc.

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

MACTek Corporation. USB HART Interface. Users Manual

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

Replacing the vacuum tube

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

PagePac PAGEPAL V

Leak Detection System

TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

TWO/FIFTY/TWO STEREO POWER AMPLIFIER

INSTALLER S & OWNER S MANUAL

AR-721U/721K/661U User s Guide

CONTROL SWITCHER User s Manual (Preliminary)

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

How To Install A Power Supply (Uplast) With A Battery Pack

Architect/Contractor Information Package

User Manual. CFG253 3 MHz Function Generator

2-Disk RAID USB and esata External Hard Drive. User Guide English

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

IR Repeater. Operation Manual P8620

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Weather Radio Alarm Clock

How To Use A Cdm250 Digital Multimeter

User Manual (English)

Installation and Operation Guide for PD4000 Series Power Control Center

Alarm Clock USER GUIDE

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Zetron Desktop Microphone Manual F

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Installation and Operation Guide for PD5100 Automatic Transfer Switch

AVerMedia AVerKey imicro User s Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Sip/Puff Switch User Guide

AXIS 291 1U Video Server Rack Installation Guide

Unattended Answering Device Instruction Manual

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Installation and Operating Manual

Research RF Sputtering Packages

SMART Board 8055i and 8055i-SMP

Transcription:

Research Isometric Transducer 0 to 5 grams and 0 to 50 grams User's Manual Research Isometric Transducer 0 to 5 g and 0 to 50 g, 110 VAC/60 Hz MA1 72-4481 Research Isometric Transducer 0 to 5 g and 0 to 50 g, 220 VAC/50 Hz MA1 72-4484

WEEE/RoHS Compliance Statement EU Directives WEEE and RoHS To Our Valued Customers: We are committed to being a good corporate citizen. As part of that commitment, we strive to maintain an environmentally conscious manufacturing operation. The European Union (EU) has enacted two Directives, the first on product recycling (Waste Electrical and Electronic Equipment, WEEE) and the second limiting the use of certain substances (Restriction on the use of Hazardous Substances, RoHS). Over time, these Directives will be implemented in the national laws of each EU Member State. Once the final national regulations have been put into place, recycling will be offered for our products which are within the scope of the WEEE Directive. Products falling under the scope of the WEEE Directive available for sale after August 13, 2005 will be identified with a wheelie bin symbol. Two Categories of products covered by the WEEE Directive are currently exempt from the RoHS Directive Category 8, medical devices (with the exception of implanted or infected products) and Category 9, monitoring and control instruments. Most of our products fall into either Category 8 or 9 and are currently exempt from the RoHS Directive. We will continue to monitor the application of the RoHS Directive to its products and will comply with any changes as they apply. Do Not Dispose Product with Municipal Waste Special Collection/Disposal Required

1 Table of Contents SUBJECT PAGE NO. Warranty and Repair Information...2 Theory of Operation...3 Operation: Transducer Mounting...4 Positioning the Muscle Sample...4 Splash Shield...4 General Information: Amplifier/Power Supply...5 Front Panel Controls: Range Selector Switch...5 Offset...5 Internal Controls and Adjustments...6 Electrical Output...6 Maintenance and Storage...6 Serial Number...6 Transducer Diagram...7

2 Warranty and Repair Information Serial Numbers All inquires concerning our product should refer to the serial number of the unit(s). Wa rr a n t y Harvard Apparatus warranties the instrument(s) for a period of two years from date of purchase.at its option, Harvard Apparatus will repair or replace the unit(s) if it is found to be defective as to workmanship or material. This warranty does not extend to damage resulting from misuse, neglect or abuse,normal wear and tear, or accident. This warranty extends only to the original customer purchaser. IN NO EVENT SHALL HARVARD APPARATUS BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you. THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR USE, OR OF ANY OTHER NATURE. Some states do not allow this limitation on an implied warranty, so the above limitation may not apply to you. If a defect arises within the two-year warranty period, promptly contact Harvard Apparatus, Inc. 84 October Hill Road, Holliston, Massachusetts 01746-1371 using our U.S. only toll free number 1-800-272-2775 or dial (508) 893-8999. Goods will not be accepted for return unless an RMA (returned materials authorization) number has been issued by our customer service department.the customer is responsible for shipping charges. Please allow a reasonable period of time for completion of repairs, replacement and return. If the unit is replaced, the replacement unit is covered only for the remainder of the original warranty period dating from the purchase of the original device. This warranty gives you specific rights, and you may also have other rights which vary from state to state. Repair Facilities and Part s Harvard Apparatus stocks replacement and repair parts. When ordering, please describe parts as completely as possible, preferably using our part numbers. If practical, enclose a sample or drawing.we offer a complete reconditioning service. CAUTION: Not for clinical use on human patients.

3 Theory of Operation This transducer operates on the principle of converting picofarad capacitance changes into an amplified DC output voltage by means of a patented circuit (U.S. Patent Number 412144). The transducer consists of a stiff beam suspended between two capacitor plates. This forms a differential capacitor. Using this principal,the beam can be exceptionally stiff, approaching the ideal of measuring force without motion. As an example, for a force of 1 gram, the beam deflection is a maximum of only 10 microns in either the 5.0 or 50 gram range mode. The linearity is within ±1% with a high DC voltage output and freedom from drift.

4 Operation Transducer Mounting The transducer comes with an integral short, rigid mounting handle. (See Fig. 1 and 2) To obtain maximum advantage of stiff beam characteristics of the transducer, it should be positioned and held in place with hardware that is as rigid as possible such that all the muscle forces are recorded (i.e. captured) and none are lost in extraneous deflections of the mounting hardware. The 55-0640 Harvard Research Support Stand is the mounting hardware of choice. Its massive,durable construction will not deflect under load. The transducer itself should be positioned such that the output cable at the rear of the transducer ends up on the bottom. (See Fig. 1 and 2) Positioning the Muscle Sample The transducer has a short shaft/rod with a groove that projects from the front. See Figure 1 below. One end of the non-stretching string must be formed into a loop and fastened into the groove on the shaft. The other end of the string is subsequently attached to the muscle preparation. The string must be at right angle to the transducer shaft and be pulled straight downward once the final setup has been completed. Grooved Shaft Mounting Handle 90 Splash Shield Non-Stretch String to Muscle Specimen Output Cable Figure 1. Positioning the Muscle Sample Splash Shield The transducer is equipped with a transparent, removable plastic shield which helps to prevent buildup of salts (i.e. corrosives) which may otherwise tend to accumulate on the transducer beam shaft and migrate into the tranducer circuit. (See Fig. 1) In time, this salt buildup can deteriorate performance. The cord/cable/wire from the beam must be directed through the slot in the splash shield without touching the edges. See Figure 1 above.

5 General Information Amplifier/ Power Supply a) The entire transducer is powered by a 12 volt AC wall transformer. (See Fig. 2) b) There is no ON/OFF switch. The unit can remain powered, as shown on the digital meter, for the entire experiment. F ront Panel Contro l s A. Range Selector The range selector switch has two positions: 5.0 gram and 50 gram (See Fig. 2) 1) In the 5.0 gram position, a 5.0 gram force produces a 5 VDC output. 2) In the 50 gram position, a 50 gram force produces a 5 VDC output. B. Offset The OFFSET control enables the user to set a zero output voltage for any pre-load value. (See Fig. 2) It is essentially a Tare Control device since it balances out static loads such as the weight of the muscle preparation prior to contraction. Mounting Handle Splash Shield Signal Cable Power Supply External Offset Control ISOMETRIC TRANSDUCER VOLTS OUTPUT Range Selector OFFSET 12 Volt AC Cable 12 Volt AC Wall Transformer Figure 2. Diagram of Isometric Transducer

6 General Information I n t e rnal Controls and Adjustments On the rear panel of the power supply are three small access holes to the trim pots. (See Fig. 3) The high and low gain trim pots are used to adjust the range. The righthand trim pot is factory set to deliver 5.0 VDC for 5.0 gram. The center trim pot is factory set to deliver 5.0 VDC for 50 gram. Either can be adjusted to deliver more or less output as conditions dictate. The OFFSET adjustment trim pot is located on the extreme left and has been factory adjusted to center the offset control. It also can be adjusted in situations where the front panel offset control does not have sufficient range. It can be used to correct for static loads up to 2.5 grams. Electrical Output a) Binding post are provided on the power supply for output connections. Red is positive (+); black is negative ( ) and also ground. (See Fig. 3) b) Output voltage is 0 to 5.0 VDC depending upon the position of the range selector switch. Output impedance is 2 kω for direct connection to all recorders. c) The transducer is linear to 100% overload (1000 g = 4 V). Figure 3. Electrical Output Maintenance and Storage a) No special precautions are required other than preventing corrosive solutions from entering the space where the output shaft exits the transducer. b) When not in use, store in a clean, dry place. Serial Number The serial number is located on the power supply circuit board. Refer to this number in any correspondence.

7 Overall Transducer Diagram Grooved Shaft Splash Shield Non-Stretch String to Muscle Specimen Power Supply External Offset Control ISOMETRIC TRANSDUCER 90 Signal Cable VOLTS OUTPUT Mounting Handle Signal Cable Range Selector OFFSET 12 Volt AC Wall Transformer 12 Volt AC Cable BNC Connector High-Gain Trim Low-Gain Trim Offset Trim To Transducer Sensing Head 12 Volt AC Input Figure 4. Overall Transducer Diagram