Operation Manual. Trans-Flo



Similar documents
DOT LED 1W, 12V AC/DC

PUCK LED 3W, 12V AC/DC REV

PUCK LED 3W, 12V AC/DC REV

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Operating Instructions Bedienungsanleitung Mode d emploi

8 Channel Status Input Panel model SIP-8

Zetron Desktop Microphone Manual F

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

VX 2400 Dimmer User's Manual

F(t) Forssell Technologies Inc

SYSTEM 4C. C R H Electronics Design

Achat 115MA full-range speaker. user manual

QuickSpecs. HP 480/277 Volt Solutions. Overview

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

High Bay Occupancy Sensor Selection Guide

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

Flex-Line Basics. Generating a Bill of Materials

D4 HP Dimmer User s Manual Rev City Theatrical, Inc.

No Phone Line II-48 System

Research RF Sputtering Packages

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Networkfleet 3500 Product Line Installation Guide

Other products available from Apollo

Digital Keypad Use s Manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Electric Rotary Actuator - On/Off or programmable control actuator

Applied Electronics. Commercial Dimming System UPDATE NOTICE

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

Broadband Telecommunications Drop Amplifier

Operating Instructions

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

=============================== WARNING

DMX512 TO 0-10 VOLT ANALOG CONVERTER OWNERS MANUAL

LUCCI AIRFUSION QUEST II CEILING FAN

The Different Types of AC Power Connectors in North America

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

16/32 Channel 1U Rack Mount CCTV Power Supply

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

TCB-2 Auto Answer Coupler Product Manual

PEDAL POWER. User s Manual

DIVERSITRONICS, INC. TM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

The Different Types of AC Power Connectors in North America

CX Zoner Installation & User Guide

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

EH-20 20m antenna. By VE3RGW

Energy efficient lighting for your home find out more.

GRX-PWM Pulse Width Modulation Interface

New XUY roller sensors

SYSTEM 45. C R H Electronics Design

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

TS-770 SERIES CONFERENCE SYSTEM

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

KRAMER ELECTRONICS LTD. USER MANUAL MODELS: SPK-C411 Closed-back Ceiling Speakers SPK-C412. P/N: Rev 1

BLOOD COLLECTION MIXER

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

Page 1. Description

15 Series - Electronic step relay and dimmer. Features SERIE

SL STRIP 400 TW LED Luminaires

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

HP UPS R1500 Generation 3

SS5C TUNABLE WHITE SOFT STRIP 4.8W 24VDC HIGH OUTPUT, COMMERCIAL GRADE 2K4K

VOIP-500 Series Phone Quick Installation Guide

Digital input modules

Turbo X channel UHF true diversity

HotSwap MBP Maintenance Bypass

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

SMART SENSOR COLLECTION

R02GA. July 31, Dear Blue Bird Owner:

MASTERSOUND. M a s t e r E m o t i o n. PF 100 Limited. Made in Italy

Modular Room Control (MRC) Series Digital Thermostat

PDS-750-TR Touring Power Supply Operator s Manual

Nest Learning Thermostat Installation Guide. Installation step-by-step

USB to RS-422/485 Serial Adapter

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

Apeiron LTE+ / E12E Power Box LED Downlight System with Automatic Battery Backup. Installation Guide

AMERBRITE UNDERWATER WHITE LED POOL LAMP

AC612 XUB/XUF/DIN sidekick too

Model 1756 Test Lead Kit

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

INSTALLATION INSTRUCTIONS

Transcription:

Operation Manual Trans-Flo

The TRANS-FLO SYSTEM is a standard-output ballast that can be dimmed on most common theatrical SCR dimming systems. The modular design of the TRANS-FLO SYSTEM streamlines set lighting installations, and its smooth dimming capability ensures controlled lighting effects. The TRANS-FLO Ballast can operate 15-inch, 2ft, 3ft and 4ft lamps in pairs; two different sized lamps can be powered from the same ballast. (Two lamps must be connected for the ballast to operate.) The POWER/DIM Cable provides primary voltage and dimming control to the first TRANS-FLO Ballast. The Single Locking Lamp Harnesses attach directly to each ballast, or they attach to a ballast via a Head Extension ( up to 25ft long ). Jumper Cables link TRANS-FLO Ballasts together ( up to 10 in a series ). The TRANS-FLO SYSTEM operates in three modes: 1. INDIVIDUAL BALLAST DIMMING MODE ( two lamps ) 2. SERIES BALLAST DIMMING MODE (up to 10 ballasts per series ) 3. NON-DIM MODE To operate, the TRANS-FLO SYSTEM in the Individual Ballast Dimming Mode you need a minimum of: TRANS-FLO Power & Dim Cable, 6ft. Primary power feed line and dimming line ( both with Edison connectors). One cable per ballast is needed for individual dimming control. TRANS FLO Two-Lamp Ballast, 120 VAC A standard-output, flickerfree electronic dimming ballast. Operates two 15- inch, 2ft, 3ft or 4ft lamps. Lamp w/ Harness ( need two per Ballast ) 15-inch Med Bipin 2ft Med Bipin 3ft Med Bipin 4ft Med Bipin 2

3

(A) Attach each TRANS-FLO circular connector tail to a locking lamps harness, or single head extension, making sure to rotate the locking ring until it clicks into its locked position. Securely connect both ends to the harness on the lamp before turning on the power. Each Trans-Flo Ballast MUST have two lamps connected to operate. A ballast can operate any two sizes of lamps at the same time. For example, a 15inch lamp can be paired with a 4ft lamp. (B) With the ballast power switched off, attach the Power /Dim Cable to the POWER IN port of the ballast. (D) Connect the Primary Power Feed (black) 3-pin U ground Edison plug to a 120 Volt AC non-dimming circuit. (E) Connect the Dimming Line (Yellow) U ground Edison plug to a theatrical SCR dimmer circuit. CAUTION: The Primary Power Feed and the Dimming Line must share a common neutral in order to dim. Failure to do so may result in an electrical short circuit. One way to ensure a common neutral is to dedicate a number of non-dimming circuits on a dimmer rack and then feed the Dimming Line to the appropriate dimming circuits on the same rack. (F) Once the Power/Dim Cable is properly circuited, set the ballast power switch to DIM. With 120 Volts AC applied on the Primary Power Feed and with the dimmer up full on the Dimming Line circuit: the ballast will illuminate the lamps and respond to the dimmer settings. Note: To check whether the Primary Power Feed circuit is hot, set the power selector switch to NON-DIM. If there is 120 VAC on the Primary Power Feed circuit, the ballast will strike the lamps even if the Dimming Line circuit has no signal. Dimming Performance Best dimming performance is achieved by connecting harnesses directly to the ballast. When adding Head Extension Cables, add the same length cable to BOTH lamps. Otherwise the lamp with the longer cable will fade out ahead of the lamp with the short cable. 4

To operate, the TRANS-FLO SYSTEM in the Series Ballast Dimming Mode you need a minimum of: TRANS-FLO Power & Dim Cable, 6ft. Primary power feed line and dimming line ( both with Edison connectors ). One cable is needed for the first ballast in a series. TRANS FLO Two-Lamp Ballast, 120 VAC A standard-output, flicker-free electronic dimming ballast. Operates two 15-inch, 2ft, 3ft or 4ft lamps. Lamp w/ Harness ( need two per Ballast ) 15-inch Med Bipin 2ft Med Bipin 3ft Med Bipin 4ft Med Bipin TRANS-FLO Jumper, 10ft & 2ft To jumper primary voltage from one ballast to the next. 5

Dimming Performance Best dimming performance is achieved by connecting harnesses directly to the ballast. When adding Head Extension Cables, add the same length cable to ALL lamps in a series. Otherwise the lamps with the longer cable will fade out ahead of the lamps with the short cable. 6

A maximum of 10 TRANS-FLO Ballasts can be connected on one Primary Power Feed Cable. A) Attach each TRANS-FLO circular connector tail to a locking lamps harness, or single head extension, making sure to rotate the locking ring until it clicks into its locked position. Securely connect both ends to the harness on the lamp before turning on the power. Each Trans-Flo Ballast MUST have two lamps connected to operate. A ballast can operate any two sizes of lamps at the same time. For example, a 15inch lamp can be paired with a 4ft lamp. B) With the ballast power switched off, attach the Power /Dim Cable to the POWER IN port of the first ballast in the series. C) Connect a 10ft or 2ft Jumper Cable from the Power Out port on the first ballast in the circuit to the Power In port of the next ballast. A maximum of ten ballasts, in series, can be connected in this manner. Jumper Couplers are required to connect two or more Jumper Cables ( see Accessories ) D) Connect the Primary Power Feed (black) 3-pin U ground Edison plug to a 120 Volt AC non-dimming circuit. E) Connect the Dimming Line (Yellow) U ground Edison plug to a theatrical SCR dimmer circuit. CAUTION: The Primary Power Feed and the Dimming Line must share a common neutral in order to dim. Failure to do so may result in an electrical short circuit. One way to ensure a common neutral is to dedicate a number of non-dimming circuits on a dimmer rack and then feed the Dimming Line to the appropriate dimming circuits on the same rack. F) Once the Power/Dim Cable is properly circuited, set the power switch to DIM on all the ballasts in the series. With 120 Volts AC applied on the Primary Power Feed and with the dimmer up full on the Dimming Line circuit: the ballasts will illuminate the lamps and respond to the dimmer settings. Note: To check whether the Primary Power Feed circuit is hot, set the power selector switch to NON-DIM. If there is 120 VAC on the Primary Power Feed circuit, the ballast will strike the lamps even if the Dimming Line circuit has no signal. 7

A) Attach each TRANS-FLO circular connector tail to a locking lamps harness, or single head extension, making sure to rotate the locking ring until it clicks into its locked position. Securely connect both ends to the harness on the lamp before turning on the power. B) With the ballast power switched off, attach the Power /Dim Cable to the POWER IN port of the first ballast in the series. D) Connect the Primary Power Feed (black) 3-pin U ground Edison plug to a 120 Volt AC non-dimming circuit. You do NOT connect the Dimming Line ( D )to a dimmer circuit. F) Switching the ballast to NON-DIM will turn on the lamps. X04-25 SINGLE Head Extension, 25ft X04-12 SINGLE Head Extension, 12 ft Black, 4-pin male to female. Connects Trans-Flo Ballast to Single Locking Harness. Maximum of 25ft from Ballast to lamp for full dimming range control. HAR-4801 4ft SINGLE Locking Harness HAR-3601 3ft SINGLE Locking Harness HAR-2401 2ft SINGLE Locking Harness HAR-1501 15 SINGLE Locking Harness PWC-C TRANS-FLO Jumper Coupler To combine jumpers if more than 10 ft are required between ballasts. 8

EXP-M&T Mounts & Ties Set, 25pk Releasable cable ties and one-inch square adhesive mounts. Recommended two Sets per lamp. EXP-HLC-T12 Lamp Holder Clip/T12, 24pk Metal Clips to hold T12 ( 1 ½ diameter ) lamps on ceilings, walls and set pieces. Recommended two Clips per lamp. Operating Voltage: 120 Volts AC Operating Frequency: 25 KHz Amperage:.70 Lamp Current: 420 ma Lamp Operation: Two Lamps, Any Combination of 15-inch, 2ft, 3ft or 4ft Dimming Range: Full Range to Black Weight: 3.1lb / 1.4Kg Dimensions: 13 x 4.5 x 2 33cm x 11.5cm x 5cm Environmental: Disposal of Old Electrical & Electronic Equipment. This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. This product is made of recyclable materials and should be disposed of in accordance with local and state regulations. Rev 10-04-2005 Part No. 3100019 Kino Flo, Inc. 2840 N. Hollywood Way, Burbank, CA 91505, USA Tel: 818 767-6528 website: www.kinoflo.com 9