Certification in the safe and efficient use of alternative refrigerants



Similar documents
The Voice of European Air-Conditioning, Refrigeration and Heat Pumps Contractors

POSITION PAPER Brussels, 29 th November 2011

Elements Elements describe the essential outcomes.

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

Part A: Fluid properties

R-32. The next generation refrigerant for air conditioners and heat pumps

R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP

EU F-Gas Regulation Guidance Information Sheet 21: Training and Certification Requirements for Refrigeration, Air-Conditioning and Heat Pumps

EU F-Gas Regulation Guidance Information Sheet 15: Fire Protection System Contractors

EU F-Gas Regulation Guidance Information Sheet 14: Refrigeration, Air-Conditioning and Heat Pump Contractors

EU F-Gas Regulation Guidance Information Sheet 5: Stationary Air-conditioning and Heat Pumps

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

Guidance for Stationary Refrigeration & Air- Conditioning

Automotive & Commercial. Air Conditioning & Refrigeration Courses 2015

Elements Elements describe the essential outcomes.

Guide to good leak testing

AREA F-Gas GUIDE A practical guide on the application of the new F-Gas Regulation to refrigeration, air conditioning & heat pump contractors

Information on New Refrigerant (R-1234yf) for A/C Service

CLIMATE CHANGE POLICY FRAMEWORK FOR REFRIGERATION AND AIR CONDITIONING SECTOR

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois Information compiled by Frank Prah, CMS

Low GWP Replacements for R404A in Commercial Refrigeration Applications

DESIGN AND APPLICATION OF AMMONIA HEAT PUMP SYSTEMS FOR HEATING AND COOLING OF NON-RESIDENTIAL BUILDINGS

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

Guidance for Mobile Air Conditioning (MAC) Sectors. Guidance: F Gas and Ozone Regulations Information Sheet MAC 3: Key Obligations

International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

AREA F-Gas GUIDE A practical guide on the application of the new F-Gas Regulation to refrigeration, air conditioning & heat pump contractors

Guidance for Stationary Refrigeration & Air-Conditioning

Guidance for Stationary Refrigeration & Air- Conditioning

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

EU f-gas regulation EN 517/2014.

AHRI Begins Second Phase of Low-GWP AREP Testing AHRI Completes Four Research Projects in 2014

A/C System Control Strategies for Major Refrigerant Options

Refrigeration, Air-conditioning and Heat Pump Sector. The Environmental Protection Agency

Planning for the ban on R22 in building air conditioning

Test Code: 8297 / Version 1

Optimization of combined heating and cooling in Supermarkets

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

The Importance of Mobile Air Conditioning to Climate Protection. Stephen O. Andersen US EPA

National Certification Schemes for Refrigeration and Air-conditioning Service Technicians

P08 Köldmedier med låg växthuseffekter

Mohan Chandrasekharan #1

The EC Ozone Regulation. Legislative Update and Strategies for HCFC Phase-out

Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29

How To Calculate The Performance Of A Refrigerator And Heat Pump

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

RS-44 (R424A) : Q & A

UA-NJ Air Conditioning & Refrigeration Division Training Curriculum

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

High School Graduation years 2013, 2014, Unit/Standard Number

Precision for Professionals: Air Conditioner Service with Bosch ACS 751, 651 and 551

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications. Samuel F Yana Motta

Chapter 3.4: HVAC & Refrigeration System

HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY

ECOCIAT. Domestic hot water heat recovery unit

Classification and Qualification STANDARDS

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

Training in Renewable Energy INFORSE-Europe proposal for implementation of the Renewable Energy Directive Draft 28/

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Facilities Maintenance Standards rev

Refrigeration & Air-conditioning Technician

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

2010 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee (RTOC)

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A

DuPont ISCEON MO89 refrigerant

Fujitsu General New Zealand Ltd

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop

DEVELOPMENT OF THE GHG REFRIGERATION

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Types : ASHRAE Refrigerant number designation: R-507

Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

MIDLAND COLLEGE SYLLABUS DEMR 1323 AUTOMOTIVE HEATING AND AIR CONDITIONING 2-4

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

EU F-Gas Regulation Guidance Information Sheet 22: Training and Certification Requirements for Mobile Air-Conditioning Systems

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Refrigeration & Air Conditioning

PREMIUM SERVICE. Service Manual. Water Dispenser. Model : PWC215T

TRAINING, EXAMINATION AND CERTIFICATION

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

MEM18084A Commission and decommission split air conditioning systems

Certified HVAC - Refrigeration Training Program

Natural Alternatives in the Refrigeration & Air Conditioning Sectors

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE. ACHP 104 Refrigeration & Air Conditioning Service II

: DuPont SUVA 410A Refrigerant

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

F-Gas Compliance. To provide a process for F-Gas Leak Testing in accordance with legislative requirements.

Protect your home s major mechanical systems with Main Street Mechanical s Home Service Agreement.

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Transcription:

Certification in the safe and efficient use of alternative refrigerants Dubai, 29th Oct 2014 Marco Buoni VicePresident, AREA Air Conditioning & Refrigeration European contractors Association (www.area-eur.be) Secretary General Italian Association of Refrigeration Technician, ATF (www.associazioneatf.org)

AREA The indisputable voice of European RACHP contractors Funded in 1988 in Brussels, Belgium Represents RACHP contractors AREA in figures: 20 national member associations 18 countries from EU and beyond > 9,000 companies (mainly SMEs) +/- 125,000 work force +/- 20 bn annual turnover Design, installation, maintenance and repair of all Refrigeration, Air Conditioning and Heat Pumps RACHP systems

Background The global phasing out of CFCs-HCFCs and future phase-down of HFCs will lead to a higher usage of alternative refrigerants / low GWP refrigerants. Issues relating to low GWP refrigerants which include safety, flammability, toxicity and high pressure will need to be properly considered when handling such refrigerants. AREA has issued 2 guidance documents on the use of Low GWP refrigerants and recommends minimum requirements for the training and certification of contractors handling low GWP refrigerants to worldwide and European decision-makers. RACHP contractors operate with complete objectivity with regards to the use of equipment and refrigerants, using both synthetic and natural fluids. RACHP contractors operate with the sole aim of ensuring the highest level of reliability, energy efficiency and cost-effectiveness to their customers. It is not AREA s intention to create a new certification scheme but rather to add specific modules to the existing EU HFCs certification scheme based on Regulation (EC) N. 303/2008 which is successfully in place in EU Member States. While HFC certification will be the basis for every contractor who wants to handle all refrigerants/any type of refrigerant, each added module will focus on the specificities of the respective low GWP refrigerant (i.e. Hydrocarbons Flammability).

To prevent HFCs emissions In Europe: F-gas regulation and certification REGULATION (EC) 842/2006 - REGULATION (EC) 517/2014 In synthesis the Refrigeration, Air Conditioning and Heat Pumps systems with HFCs should have: - Logbook - Periodical inspections - Installation, repair only by certified craftsmen Refrigerant to be withdraw and sold by distributors only to certified undertakings

REGULATION (EC) 303/2008 MINIMUM COMPETENCE OF PERSONNEL T = THEORETICAL P = PRACTICAL CATEGORIES DUTIES AND KNOWLEDGE I II III IV 1 Basic thermodynamics T T T 2 Environmental impact of refrigerants and corresponding environmental regulations T T T T 3 Checks before putting in operation, after a long period of non-use, after maintenance or repair intervention, or during operation P P 4 Checks for leakage T/P T/P T/P 5 6 Environment-friendly handling of the system and refrigerant during installation, maintenance, servicing or recovery Component: installation, putting into operation and maintenance of reciprocating, screw and scroll compressors, single and two-stage P P P P P 7 8 Component: installation, putting into operation and maintenance of air cooled and water cooled condensers Component: installation, putting into operation and maintenance of air cooled and water cooled evaporators P P 9 Component: installation, putting into operation and servicing of Thermostatic Expansion Valves (TEV) and other components P 10 Piping: building a leak tight piping system in a refrigeration installation P P

Certification of technicians in servicing sector how it runs Brazing Vacuum, Charge, Recovery Temperature, Pressure, Subcooling, Superheating

Registration and monitoring Online Register with the name of all the service technicans and companies which are certified Anybody can see if someone is or is not certified

Why create Training, Assessment, Certification? Policy - International Agreements : to reduce Refrigerant Emissions, GHG, ODS Increase energy efficiency (reducing CO2 Emission) Increasing competence, safety in the installations contractors A more aggressive competition requires prove of higher quality and certification customers: Whole sellers, distributors, big customers requires environment friendly and energy efficient products Required Certification of the personnel and of the companies who handle air conditioning, refrigeration and heat pumps equipment

Contractors training with low GWP refrigerants: mind the gap! In EUROPE, the use of HFCs is legislatively decreased ( by 79% by 2030 ) and consequently the use of alternative refrigerants is pushed, there will be a gap between training offer and training needs resulting in a shortage of trained contractors

AREA position on training and certification of LOW GWP refrigerants (1) The future phase-down of HFCs will lead to a higher use of alternative refrigerants / low GWP refrigerants. Low GWP refrigerants have issues on safety, flammability, toxicity and high pressure which will need to be properly considered when handling those refrigerants. AREA recommend to worldwide and European decision-makers minimum requirements for training and certification of contractors handling low GWP refrigerants.

AREA position on training and certification of LOW GWP refrigerants (2) It is not AREA s intention to create a new certification scheme only to add specific modules to the existing HFCs certification scheme based on Regulation 303/2008. While HFC certification will be the basis for every contractor who want to handle every refrigerant, each added module will focus on the specificities of the respective LOW GWP refrigerant (i.e. Hydrocarbons Flammability).

(1) Minimum Requirements listed for the Specific module HC NH 3 CO 2 HFO * HC NH 3 CO 2 BASIC THERMODYNAMICS AND PHYSICS Thermodynamic properties of Low GWP refrigerant: temperature, pressure, density, thermal capacity, p/h diagram T T T Differences between Low GWP refrigerants and HFCs T T T Toxicity characteristics, grades and limits for the human body --------------- T T Characteristic of Flammability of the substances, velocity of propagation, LFL, UFL, occupancy T T --------------- Specific components for that refrigerant in the refrigeration cycle T T T Material compatibility --------------- T T Oil compatibility, requirements and oil return T T T *HFO1234yf: same, minimum requirements as Hydrocarbons HC *HFO1234ze: same minimum requirements as HFCs

(2) Minimum Requirements listed for the Specific module HC NH 3 CO 2 HFO * HC NH 3 CO 2 GOOD PRACTICE Identify typical application of Low GWP refrigerants RAC systems 2 (refer to AREA: Low GWP Refrigerants Guidance) P P P State and identify the commonly used refrigerants designation P P P State the requirements for safely labeling Low GWP refrigerant RAC systems 6 P P P Select appropriate tools, equipment and PPE for work on Low GWP RAC systems 6 P P P Recovery of the refrigerant P P P Venting the refrigerant in a safe way (according to national legislation) P P P Calculate the safe fill weight for the recovery cylinder (density difference between HFCs and Low GWP refrigerants) 2 P P P Leak check direct assessment with the correct equipment P P P Make vacuum of the refrigerant preventing moisture in the system and without refrigerant emissions P P P Make charge of the refrigerant with no emission relief P P P Make a connection without brazing with alternative connections P P P Check the correct functioning of the safety ventilation system P P Check the correct functioning of the safety system controls P P P [1] All practical trainings should include theoretical training [2] City and Guilds, Level 2 and Level 3 Refrigeration and Air Conditioning CPD Pathways, March 2012 v1.0 [3] It is normally accepted to vent hydrocarbons with low charges (please refer to national legislation) [4] It is normally accepted to vent CO2 (please refer to national legislation)

(3) Minimum Requirements listed for the Specific module HC NH 3 CO 2 HFO * HC NH 3 CO 2 HEALTH AND SAFETY REQUIREMENTS Safe system shutdown and isolation 2 P P P Extinguish a fire, identify the appropriate fire extinguisher P P --------------- First aid care treatment for frostbite P P P First aid due to fire burn P P --------------- First aid suffocation due to breathing problems --------------- P P Safety issues related to high pressures --------------- --------------- P Calculate LFL (confined space) T T --------------- Calculate confined space for asphyxiation (heavier than air) T --------------- T Check that Health and Safety rules in the refrigeration system location are respected (emergency exits, fire alarms, leak T T T detectors ) Correct use of Personal Protective Equipment P P P

(4) Minimum Requirements listed for the Specific module HC NH 3 CO 2 HFO * HC NH 3 CO 2 REGULATIONS AND STANDARDS Knowledge of European and National Regulations and standards T T T Storage of the refrigerant T T T Transport of the refrigerant T T T Describe the process for handing over system to costumer completing and passing on appropriate commissioning documentation 2 P P P

Use the right Equipment (1) (few available on the market) Characteristic: Flammable proof Leak detector Recovery unit Charging station (automotive)

Use the right Equipment (2) (few available on the market) A flammable gas detector should be used to monitor the air in the work area. If an electronic leak detector is used it must be safe and sensitive to the flammable refrigerant. Most HFC leak detectors do not need this requirement. Leak detection fluid can be used. HFC recovery machines have not been assessed for use with flammable refrigerants. Approval must be sought from the manufacturer before using a standard HFC recovery machine with any flammable refrigerant they may be safe to use with flammable HFCs but not HCs. A recovery machine suitable for use with HCs is available and could be used with other flammable refrigerants. More accurate scales are necessary when charging small, critical charged systems with some flammable refrigerants such as HCs. An accuracy of ±5 g is often necessary most scales used for service are not this accurate. A dry powder or CO 2 fire extinguisher must be available at the location. A suitable ventilation fan should be used when working inside if there is insufficient natural ventilation. Source: BRA Guide to Flammable Refrigerants, July 2012 You will need to determinate if your current R-134a detector can be used with a mildly flammable refrigerants Source: Dupont Guidelines for Use and Handling of HFO-1234yf

Refrigerant Emissions and Leakage-blended learning for alternative refrigerants in new equipment safety, efficiency, reliability and containment e-library REAL e-learning Alternatives Co-financed by classroom practice We are proud to have among our stakeholders the European Commission DG Clima & UNEP Ozone Action

THANK YOU! Email: buoni@centrogalileo.it Marco Buoni VicePresident, AREA Air Conditioning & Refrigeration European contractors Association (www.area-eur.be) Secretary General Italian Association of Refrigeration Technician, ATF (www.associazioneatf.org)